        241.
        2013.10 서비스 종료(열람 제한)
        Recently, Seismic design criteria for major domestic structures has been being improved constantly, because the importance of seismic design for major public infrastructures is largely recognized. A preliminary assessment of the seismic performance on the existing railway tunnel, a precedent task before conducting a detailed assessment, can be use as the standard of judgement to decide whether to perform a detailed assessment or not. On the other hand, There are no reasonable study in this area. In this study, an assessment method was presented to evaluate a seismic performance of the existing railway tunnels which seismic design are not performed more economically and rationally.
        242.
        2013.10 서비스 종료(열람 제한)
        In this study, experimental research was carried out to improve and evaluate the seismic performance of reinforced concrete beam-column joint using Embedded Carbon Fiber Rod and Carbon Fiber Sheet in existing reinforced concrete building. Test result shows that retrofitting specimen(LBCJ-SP45, CS2, CRUS) designed by the improvement of seismic performance of reinforced concrete beam-column joints load-carrying capacities were increased 1.34 ~ 1.54 times in comparison with the standard specimen.
        244.
        2013.05 KCI 등재 서비스 종료(열람 제한)
        비보강 조적벽체를 이용한 저층 건축물은 국내에 가장 흔히 볼 수 있는 주거형태이지만, 비보강 조적벽체는 높은 횡강성에 비하여 연성능력 부족 등의 이유로 지진으로부터 구조적 피해를 피하기 힘든 횡력저항시스템으로 알려져 있다. 하지만, 국내 비보강 조적벽체 전단강도와 전단강성에 대한 실험적 연구는 부족한 편이며, 실제 지진이 발생했을 비보강 조적벽체를 횡력저항요소로 사용하는 건축물의 내진성능에 대한 연구는 상대적으로 부족한 실정이다. 이로 인하여 국내 비보강 조적벽체의 특성을 반영하고 있다고 볼 수 없는 FEMA 356에서 제시하고 있는 비보강 조적벽체의 전단강도와 강성을 준용하여 사용하고 있다. 본 연구에서는 우선 FEMA 356에서 제시하고 비보강 조적벽체의 전단강도와 강성을 실험결과와의 차이에 대해 기술하고, 이 차이가 현황조사와 실험데이터를 바탕으로 결정한 표본 비보강 조적조 건축물의 내진성능에 미치는 영향과 경과년수에 따른 영향을 증분동적해석을 이용하여 계산된 붕괴여유비와 구조성능의 불확실성을 표현하는 베타값을 이용하여 분석하였다. 해석결과를 통하여 FEMA 356에 의한 전단강도와 강성을 사용할 경우 조적조 건축물의 붕괴여유비와 베타값을 과소평가하는 것으로 나타났다. 하지만, 두 경우 모두 국내 내진설계기준에서 제시하는 성능기준을 만족하지 않는 것으로 나타났으며, 경과연수가 클수록 이런 현상은 뚜렷해지며, 30년 이상 경과된 조적조 건축물은 2400년 재현주기의 지진에 붕괴확률이 약 90%에 도달하는 것으로 나타났다.
        245.
        2013.04 서비스 종료(열람 제한)
        For coupled shear walls, coupling beams are the first line of dissipation under earthquakes. So coupling beams are important energy dissipation component. When coupling beams have little depth-to-span ratio, routine coupling beams have less capacity of energy dissipation.There are less design methods for coupling beams with depth-to-span less than 2. In this paper a specimen with steel plate reinforcement coupling beam was designed and analyzed by means of FEM software ABAQUS.
        246.
        2013.04 서비스 종료(열람 제한)
        Recently, Seismic design criteria for major domestic structures has been being improved constantly, because the importance of seismic design for major public infrastructures is largely recognized. A preliminary assessment of the seismic performance for the existing rapid-transit railway tunnel, a precedent task before conducting a detailed assessment, can be use as the standard of judgement to decide whether to perform a detailed assessment or not. On the other hand, There are no reasonable study in this area. In this study, an assessment method was presented to evaluate a seismic performance of the existing rapid-transit railway tunnels which seismic design are not performed more economically and rationally.
        247.
        2013.04 서비스 종료(열람 제한)
        Many existing building in korea, constructed according to an out-date standard, were found to be inadequate to withstand major earthquake. Accordingly, significant research effort has been devoted to develop and evaluate different strengthening techniques to increase to seismic resistance of R/C structure. In our previous research[1], the galss fiber sheet and carbon fiber brace system for seismic strengthening was developed. In the study, a three-story R/C building that represent a typical Korean school constructed in 1980s was selected, and its seismic performance before and after strengthening was evaluated based on the seismic capacity evalution method.
        248.
        2013.04 서비스 종료(열람 제한)
        In this study is experiment result of reinforced concrete squat shear walls with deformation capacity and structural strengthening performance. In order to evaluate the seismic performance of squat shear walls, slits with opening was used as a variables. The experimental results show that ductility capacity of reinforced concrete squat shear wall with slits is superior compared to normal reinforced concrete squat shear wall
        249.
        2013.04 서비스 종료(열람 제한)
        In order to evaluate earthquake response of structures affected by shallow soft soil deposits, centrifuge tests were performed. The test specimen was composed of a single-degree-of-freedom structure model, a shallow foundation and sub-soil deposits in a centrifuge container. The structure response directly measured from the test showed that a large rocking rotation occurred due to the soil-foundation interaction. Thus, the acceleration of the structure was significantly smaller than the fixed base structure response.
        250.
        2013.04 서비스 종료(열람 제한)
        This study presents the application of seismic performance evaluation methods specialized in dam and reservoir structures in Korea. Related criteria and evaluation methods are reviewed, and then, the indicators needed to perform the seismic performance evaluation and how to take advantage of these are suggested in this study.
        251.
        2013.01 KCI 등재 서비스 종료(열람 제한)
        연결보를 가진 전단벽 시스템은 벽체의 개별 강성을 합산한 것보다 훨씬 큰 강성을 확보할 수 있기 때문에 효율적인 횡력저항시스템으로서 40층 이하의 중 고층 건물에 널리 적용되고 있다. 일반적으로 사용되는 철근콘크리트 연결보는 철근배근이 복잡해 시공성이 저하되고, 철골연결보의 경우에는 과도한 스티프너의 사용으로 인해 경제성이 저하된다는 단점을 가지고 있다. 따라서, 이 연구에서는 철근콘크리트와 철골부재를 합성하여 시공성 및 경제성을 개선하고 단면크기를 줄일 수 있는 불연속웨브가 적용된 프리스트레스트 합성연결보를 개발하였다. 개발한 프리스트레스트 합성 연결보의 구조적인 성능을 검증하기 위해서 전단철근비를 주요 변수로 두 개의 실험체를 제작하여 반복하중실험을 수행하였으며, 실험결과는 제안된 연결보의 내진성능을 검증하였다.
        252.
        2013.01 KCI 등재 서비스 종료(열람 제한)
        본 연구는 우리나라에서 가장 일반적인 중소규모의 비내진 상세를 가진 건축물을 대상으로, 노후도를 고려하여 내진성능을 평가하였다. 평가결과, 준공 후 24년이 경과되었으나 노후도는 대체로 양호한 것으로 평가되었고, 1차, 2차 내진성능평가는 기준지표를 만족하지 못하는 것으로 나타났다. 3차 내진성능평가에서는 층간변위비를 기준으로 목표성능은 만족하지만 보강이 필요한 것으로 판단되었다. 대상 건축물에 벽체보강, 가새보강, 댐퍼보강을 한 후 내진성능평가를 실시한 결과, 보강방법에 상관없이 층간변위비는 현저히 감소하여 즉시거주수준을 만족하는 수준으로 나타났다. 그러나 벽체보강의 경우 밑면전단력이 2배 이상 증가되어 기존기초에 대한 검토가 필요하다.
        253.
        2012.11 서비스 종료(열람 제한)
        This study conducted seismic performance evaluation of externally reinforced water tank using shaking table test. From the shaking table test result, externally reinforced system shows sufficient stiffness for water tanks and high natural frequency over 8Hz. The test result also showed safety result of induced maximum stress of water tank shown in the allowable stress.
        254.
        2012.11 서비스 종료(열람 제한)
        In this study, experimental research was carried out to improve and evaluate the seismic performance of reinforced concrete beam-column joint using carbon fiber sheets in existing reinforced concrete building. Test result shows that retrofitting specimen(LBCJ-CS1, CS2) designed by the improvement of seismic performance of reinforced concrete beam-column joints load-carrying capacities were increased 1.26~1.35 times in comparison with the standard specimen.
        255.
        2012.05 서비스 종료(열람 제한)
        To evaluate seismic performance of existing school buildings, This study performed pushover analysis using Midas/Gen Ver.795. The outcome shows that building have insufficient seismic performance and seismic reinforcement is necessary to have enough seismic performance.
        256.
        2012.05 서비스 종료(열람 제한)
        This experimental study evaluates of seismic performance on strain-hardening cement-based composite (SHCC). The objective of this study is to evaluate of cross-sectional reduction (1400×800×70 and 1120×520×40㎜) and design compressive strength level (45 and 50 MPa). The experimental results as cross-sectional reduction, peak loads are not significantly different. but energy area is decrease.
        257.
        2012.05 서비스 종료(열람 제한)
        This paper experimentally evaluates effects of fiber ratio of the seismic performance of infill walls. Variable of study was a concrete and fiber ratio (PVA1.3+PE0.2 and PVA0.75+PE0.75). The experimental investigation consisted of cyclic loading tests on 1/3-scale models of infill walls. The experimental results show that SHCC specimens was more ductile behavior.
        258.
        2012.01 KCI 등재 서비스 종료(열람 제한)
        최근 PC 공법을 도입하려는 시도가 많이 이루어지고 있다. 그러나 PC 벽체에 대한 연구는 개발의 어려움이 있어 상대적으로 더디게 발전되어 왔다. 본 연구에서는 PC벽체의 기존의 접합부의 시공성 및 구조성능을 개선하기 위하여 수직접합부의 개선안을 개발하였고, 이에 대한 구조성능평가를 진행하였다. 제안된 PC벽체의 수직접합부 구조적인 성능을 검증하기 위하여 반복적인 횡하중 재하시험을 진행한 결과, 기존의 일체형 PC벽체와 동등이상의 내진성능을 발휘하는 것으로 나타나 향후 구조물의 주요 횡력저항요소로 충분히 적용가능할 것으로 판단된다.
        259.
        2011.07 KCI 등재 서비스 종료(열람 제한)
        일반적으로 조적조는 시공이 용이하고 경제적인 구조로서 국내뿐만 아니라 해외에서도 가장 오래되고 광범위하게 사용되는 구조이다. 조적벽을 RC 골조에 장막벽으로 사용하는 채움벽 형태의 구조는 시공이 용이하고 경제적이기 때문에 저층 주거용 건물, 학교건물 등에 많이 적용되고 있으나, 설계시에는 비구조부재로 취급되어 채움벽의 효과를 반영하지 않고 있다. 본 연구에서는 기존의 사각형 조적개체의 횡력에 대한 취약성을 개선하기 위해 개발된 육각형 블록을 RC 골조 채움벽에 적용한 채움벽 골조에 대한 구조실험을 수행하여 육각형블록 조적채움벽의 효과를 평가하고자 하였다.
        260.
        2011.05 KCI 등재 서비스 종료(열람 제한)
        역량스펙트럼방법은 구조물의 내진성능을 평가하는 도구로서 점점 더 이용 빈도가 증가하고 있다. 강도감소계수는 역량스펙트럼방법에서 정의하는 비탄성요구스펙트럼을 생성하기 위해 사용되며 다양한 강도감소계수 공식들이 제안되고 있다. 이 연구는 강도감소계수의 공식이 비탄성요구스펙트럼의 형상에 미치는 영향과 아울러 교량의 지진응답변위에 미치는 영향을 평가하였다. 연구 목적에 따라, 기존에 제안된 몇 가지 강도감소계수 공식들이 조사되고, 예제연구를 통하여 분석되었다. 서로 다른 원호각을 갖는 곡선교를 선정하여 서로 다른 강도감소계수 공식을 적용하여 역량스펙트럼방법으로 교각의 변위를 평가하였다. 역량스펙트럼의 결과를 검증할 목적으로 비선형시간이력해석도 함께 수행되었다. 연구결과에 의하면, 역량스펙트럼방법은 더 큰 원호각을 갖는 교량일수록 실제보다 더 큰 교각의 변위를 산출한다. 비탄성요구스펙트럼을 작성하는 많은 방법이 제안되어 있음에도 불구하고, 각 방법들이 산출하는 교각의 비탄성변위응답은 큰 차이가 없다.