검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 419

        341.
        2014.10 서비스 종료(열람 제한)
        The research presents a reinforced concrete columns using Strain Hardening Cementitious composites (SHCC). For the columns, in order to predict seismic performances, several methods are evaluated in SDOF systems such as the Capacity Spectrum Method (CSM), the Direct Displacement Based Design (DDBM) and the Displacement Coefficient Method (DCM).
        342.
        2014.10 서비스 종료(열람 제한)
        The purpose of this study is the evaluation of the seismic performance for the reinforced concrete piloti building considering special earthquake load. For this, nonlinear static push-over and dynamic seismic response analysis for the two models designed with and without special earthquake load were carried out.
        343.
        2014.10 서비스 종료(열람 제한)
        There are several guidelines for seismic performance evaluation given by institutions to proper seismic reinforcement. The guidelines given by Korea Infrastructure Safety & Technology Corporation, National Emergency Management Agency and Korea Educational Development Institute were analyzed. This paper analyzed seismic test procedure of three institutions and compared stage specific difference.
        344.
        2014.10 서비스 종료(열람 제한)
        In this paper, the seismic performance of existing column-tree connections using composite deck plate was experimentally evaluated. As a result, although two specimens were not founded the brittle fracture at the beam-to-column, composite slab were destroyed by crushing at the beam-to-column connection.
        345.
        2014.10 서비스 종료(열람 제한)
        The conventional brace system is generally accepted lateral load resisting system for steel structures due to efficient story drift control and economic feasibility by frame materials decrease. But the lateral stiffness of the brace decreases following buckling in this system and buckling causes unstable structures with strength deterioration hysteresis performance. Buckling restrained brace system that performs stable behavior after yielding of core element prevented from buckling by tube element is better than conventional brace system in point of earthquake energy absorbing capacity. In this study, the seismic performance of the multi-story steel frames applied for brace and buckling restrained brace is respectively analyzed, so that, the damage of two systems is quantitatively evaluated by analyzing energy absorption capacity.
        346.
        2014.10 서비스 종료(열람 제한)
        For the seismic performance assessment of a building, a lot of time and manpower are needed. In this paper, alternative procedure based on modeling transformation for the effective seismic performance assessment of the buildings is suggested. The suggested procedure is applied for the seismic performance assessment of an apartment building consisted of the ordinary reinforced concrete shear walls as the example model and its effectiveness is reviewed
        347.
        2014.10 서비스 종료(열람 제한)
        This is preliminary study for development of specialized seismic performance evaluation and reinforce guidelines for piloti-type buildings. A residential Building with Pilotis was selected and the seismic performance evaluation was performed. The vulnerable parts of the piloti-type building for earthquake and the risks are verified. Finally, the necessity of evaluation and reinforce guidelines for the building with pilotis is presented.
        348.
        2014.10 서비스 종료(열람 제한)
        In this study, experimental research was carried out to improve and evaluate the seismic performance of reinforced exterior concrete beam-column joint strengthened with different anchorage length of embedded CFRP Rods in existing reinforced concrete building. Test result shows that retrofitting specimen(RBCJ-SR2T1, SR2T2) designed by the improvement of seismic performance of reinforced concrete beam-column joints, maximum load-carrying capacities were increased 2.24 ~ 2.24 times in comparison with the standard specimen(RBCJC). Also, retrofitting specimens showed stable hysteretic behavior compared to the standard specimen(RBCJC).
        350.
        2014.05 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 기존 철근콘크리트 건물의 보-기둥 접합부의 내진성능의 개선을 위해 보-기둥 접합부 영역을 FRP보강재(매입형 CFRP Rod, CFRP시트)를 사용하여 보강한 후 내진성능을 평가하였다. 총 6개의 실험체를 제작하고 실험을 수행하여 내진성능을 평가하였으며, 본 연구의 실험결과를 근거로 다음과 같은 결론을 얻었다. 기존 철근콘크리트 보-기둥 접합부의 접합부 영역을 보강한 결과, 초기 재하시 접합부 영역의 균열억제 효과와 재하 전 과정을 통하여 보강재의 구속효과로 인하여 균열억제 효과가 커서 안정적인 파괴형태 및 내력향상 효과를 나타내었다. 매입형 CFRP Rod와 CFRP시트를 활용한 RC 외부 보-기둥 접합부 실험체 RBCJ-SRC2는 표준실험체 RBCJ와 비교하여 변위연성4, 7에서 각각 최대 내력은 1.97배, 에너지소산능력은 2.08배 증가하였다. 또한, 실험체 RBCJ-SR시리즈와 비교하여 최대내력이 1.09~1.11배 증가하였다. 그리고 실험체 RBCJ-CS, RBCJ-SR시리즈, RBCJ-SRC2는 변위연성 5, 6에서 표준실험체 RBCJ 보다 에너지소산능력이 1.10~2.30배 증가하였다. 그리고 에너지소산능력은 변위연성 4에서 13.0~14.4% 증가하였다.
        351.
        2014.04 서비스 종료(열람 제한)
        In this study, experimental research was carried out to improve and evaluate the seismic performance of reinforced concrete beam-column joint using Groove and Embedding FRP Rod and CFRP Sheet in existing reinforced concrete building. Test result shows that retrofitting specimen(RBCJ-SR2, SRCB2) designed by the improvement of seismic performance of reinforced concrete beam-column joints load-carrying capacities were increased 1.78 ~ 2.29 times in comparison with the standard specimen.
        352.
        2014.04 서비스 종료(열람 제한)
        In this paper, the seismic performance of RC frame with deterioration of structural capacity was evaluated by using capacity spectrum method. And the efficiency of retrofit by using infilled masonry was checked from the evaluation of its seismic capacity for various layout. As a results, it was found that the masonry infill wall increased the stiffness and strength, but reduced ductility.
        353.
        2014.04 서비스 종료(열람 제한)
        Currently the seismic performance evaluation for existing buildings are being made simply through the review of the analytical technique corresponding to design specifications on beam, column, shear wall, joint and so on. Also the seismic performance is evaluated to 4 steps as immediate occupancy level(IO), life safety level(LS), collapse prevention level(CP), collapse occurrence level(CO). However, in case of a structure being used for a number of years after construction, which may have partial damages and durability degradations may show significant differences between the analysis results and the actual behavior during an earthquake. Therefore, a improved seismic performance assessment is proposed based on risk assessment and seismic performance techniques since more systematic evaluation and condition assessment are required, and thus the practical and economical seismic retrofit measures for the existing facilities and for the reasonable seismic design as well are to be developed more than ever before.
        354.
        2014.04 서비스 종료(열람 제한)
        The Recent earthquake damage of surrounding countries is increasing, occurrence of frequent earthquakes in the country, thus, the interest about the seismic performance of the structure is increasing. Korea, was established in 2008 earthquake measures method, KBC2009 was also amended by design standards. KBC2009 based seismic design and seismic strengthening has become mandatory, Design of the building before the current seismic design standards must be satisfied in KBC2009. Therefore, ATC-40, FEMA-273 and seismic performance evaluation of Korea Infrastructure Safety Corporation will conduct the seismic performance evaluation at the Previous design code building.
        355.
        2014.04 서비스 종료(열람 제한)
        Recently a lot of strong earthquakes are happened in China. By the report of the Earthquakes that can be seen the URM buildings are destroyed by the highest rate. Thus in this study, the performance and vulnerable of URM houseing buildings in China, and use them to describe the derivative and evaluate the seismic performance have been analyzed.
        356.
        2014.04 서비스 종료(열람 제한)
        The purpose of this study is to evaluate a RCS strengthening method for medium & low-rise R/C buildings using the nonlinear analyses of member-level. In this study, a three-story R/C buildings that represents a typical Korean school constructed in the 1980s was selected. Seismic capacities of the building before and after CFCC strengthening method are evaluated using the nonlinear static & dynamic analyses of member-level.
        357.
        2014.04 서비스 종료(열람 제한)
        In the research, there were seismically strengthened reinforced concrete composite columns by applying Strain Hardening Cementitious Composites(SHCC). The seismic performance of SHCC-RC composite columns were studied by the concepts of seismic performance-based design approaches as well as with experiments.
        358.
        2014.04 서비스 종료(열람 제한)
        In this paper, the effects of beam splice location on seismic performance of column-tree connections were experimentally and analytically evaluated. The study results showed very little difference between the results of analytical and those of experimental.
        359.
        2014.04 서비스 종료(열람 제한)
        In this paper, in order to evaluate the seismic performance on semi-rigid column-tree type connections, the experimental results and the finite element analysis results were compared. As a results, both results were considerably similar.
        360.
        2014.04 서비스 종료(열람 제한)
        This paper indicates seismic performance of wing walls using Engineered Cement Composite(ECC) for retrofit of non-ductile existing building. The specimens consist wing walls of different thickness. The specimens is tested cyclic lateral loads. The test results indicated that wing walls seismic performance of 100 mm thickness improved than 70 mm wing walls.