검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 100

        24.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In actual seawater desalination plant, the pressure loss due to frictional force of pipe is about 3~5 bar. Also, the pressure loss at pipe connection about 1~3 bar. Therefore, the total pressure loss in the pipe is expected to be about 4~8 bar, which translates into 0.111 to 0.222 kWh/m3 of energy when converted into the Specific Energy Consumption(SEC). Reducing energy consumption is the most important factor in ensuring the economics of seawater desalination processes, but pressure loss in piping is often not considered in plant design. It is difficult to prevent pressure loss due to friction inside the pipe, but pressure loss at the pipe connection can be reduced by proper pipe design. In this study, seawater desalination plant piping analysis was performed using a commercial network program. The pressure loss and SEC for each case were calculated and compared by seawater desalination plant size.
        4,000원
        25.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        2018년 환경부에서 발표된 수도정비기본계획에 따라 다양한 수자원 활용의 중요성이 증가하고 있으며, 여러 수원 을 혼합하여 원수 또는 생산수로 활용하는 워터 블렌딩 방식은 미국, 호주를 비롯한 여러 나라에서 시도되고 있다. 본 연구에 서는 공업용수 공급 목적으로 100,000 m3/일 규모 해수담수화 사업이 추진되고 있는 충남 대산 지역을 대상으로, 해수와 호 소수, 침전수, 폐수 방류수 등 타 수원을 블렌딩할 때 수종 및 혼합비율에 따른 영향을 분석하였다. 타 수원 혼합비율 10~50% 조건에서 혼합수 염분농도는 약 50%까지 감소하였지만, 탁질 및 유기물 농도는 1.6~2.0배 수준으로 증가하는 것을 확인하였 다. 실험실 규모 역삼투 공정 성능평가 결과, 해수의 단독활용 대비 원수 혼합 시 막오염 경향이 증가하였으며 혼합비율 10~50%에서 평균 4.1배의 플럭스 저감률을 나타내었다. 성능모사를 통한 역삼투 공정 성능분석에 따르면 혼합비율 50% 조 건에서 역삼투 공정 에너지 사용량이 평균 39% 절감될 수 있을 것으로 기대되나, 운영비용 등 혼합수 활용에 대한 전반적인 영향분석을 위해서는 모형플랜트 규모에서 장기간 성능평가가 필요하다.
        4,000원
        26.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        산업화와 기후 변화는 깨끗한 식수에 대한 수요 증가를 초래하였다. 막분리공정을 이용한 해수담수화는 물의 수요에 대한 요구를 채울 수 있는 경제적으로 실현 가능한 대안 중 하나이다. 막분리공정에서 2차원 재료들은 기존 역삼투분리막 (reverse osmosis membrane) 기반의 폴리아마이드 박막복합막(TFC-PA)과 비교하였을 때 막의 강도를 높여주고 투수성을 용이하게 하며 높은 염제거율 및 높은 선속률과 선택성을 보여준다. 이 리뷰 논문에서는 재료, 합성, 특징, 해수담수화 과정을 기반으로 다양한 2차원 재료로 구성된 복합막들을 소개하고 있다.
        4,500원
        27.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Due to global climate change, Korea is experiencing flooding and drought severely. It is hard to manage water resources because intensive precipitation during short periods and drought are commonly occurred in Korea, recently. Severe drought occurred in 2015 and 2017 in the islands, and coastal and inland areas in Korea, and the citizens experienced decreased water supply and emergency water service by using bottled water. Therefore, the Korean government provided additional governmental funds such as the grant of drought disaster. In this study, we tried to calculate the cost of water for drought response based on the cost of tap water for the regional local governments in Korea and the grant of drought disaster by the Ministry of the Interior and Safety in Korea, etc. The estimated costs of water for drought responses in coastal and inland areas which have a chance to apply alternative water sources such as brackish or seawater desalination and water reuse in Korea were higher than in other areas in Korea. Additionally, as the novel approach of drought response, the 300 m3/day-scale desalination vessel was suggested to provide desalinated water for the islands in Korea. The estimated expenses of water supply for the target island areas (Sinan-gun and Jindo-gun) by the desalination vessel was lower than those by emergency water service by using bottled water.
        4,000원
        28.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Reverse osmosis seawater desalination facilities can extend the cleaning cycle and replacement time of the reverse osmosis membrane by pretreatment process. Selection of pretreatment process depends on water quality. It was attempted in this study to select approriate pretreatment process for the Masan bay, which was high in particles and organic content. For this purpose, performances of pretreatment processes such as filter adsorber (FA), pore controllable fiber (PCF), and ultrafiltration (UF) were compared based on the silt density index (SDI). The SDI value of the filtrate should be less than 3. The study results showed that UF can produce the filtrate quality satisfying the requirement. However, the transmembrane pressure (TMP) of UF increased quickly, reaching 0.6 bar within 4 days. In order to secure stable operation, FA and PCF were combined with UF. The study results showed that combination of PCF and UF was able to extend the filtration duration (more than 2 months) until to reach TMP of 0.6 bar.
        4,000원
        29.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기후변화로 인해 가속화되고 있는 충남 지역 가뭄현상에 대응하고 대산 임해산업단지의 증가하는 용수 수요를 만족하기 위해서, K-water에서는 100,000 m3/일 규모 역삼투 해수담수플랜트 건설 사업을 추진하고 있다. 이에 본 연구에서는 해수담수플랜트 운영비용의 70% 이상을 담당하는 역삼투 공정 성능에 영향을 미치는 주요 인자에 대한 성능 분석을 수행하였다. 대산 지역 해수 염분농도 및 수온 변화 조건에서 RO 공정의 전력소모는 2.39 ± 0.13 kWh/m3로 나타났으며, 막여과유속과 회수율이 낮을수록 전력소모가 절감되어 연간 운영비용이 감소하였다. 주요 막 제조사별 고유량 막의 성능 비교 결과, 전량 2단 여과공정(full two pass) 기준 생산수 TDS는 평균 3.84 mg/L로 양호하였고, 전력소모는 2.22 ± 0.13 kWh/m3 수준으로 확인되었다. 역삼투 공정 구성을 전량 2단 여과방식에서 partial 또는 split partial 방식으로 변경함에 따라 전력소모는 최대 0.29 kWh/m3, 막모듈 설치비용은 최대 15.6% 절감 가능할 것으로 기대된다.
        4,000원
        31.
        2019.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 축전식 탈염 공정에 분할 전극을 이용하여 탈염 성능을 향상하고자 하였다. 운전조건으로 NaCl 수용액에 대하여 20 mL/min의 유속과 1.2 V, 3분의 흡착 조건과 -1 V, 1분의 탈착 조건으로 전극의 분할 여부에 따른 탈염 효율을 측정함으로써 실험을 진행하였다. 분할되지 않은 전극에서는 유효면적이 146 cm2일 때 40%의 탈염 효율이 나타났고 분할 전극의 유효면적이 133 cm2일 때 57%의 탈염 효율을 보였다. 같은 분할된 전극에서 탈염 효율은 2 cm 간격을 두었을 때 49%, 1 cm의 간격을 두었을 때 57%로 확인되었다. 탈염 효율이 일반 CDI보다 분할 전극 CDI가 높았고 분할 전극 사이의 간격이 좁을수록 증가하였다.
        4,000원
        32.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Desalination plants are generally studied with higher operating costs compared to water supply facilities. This study was conducted to reduce the cost of water production and to preserve existing water resources. Therefore, the purpose of this study was to utilize the control valves to increase maximum efficiency, thereby reducing the power of the pumps and operating costs. Specific energy consumption was shown to reduce the process operating power by up to 1.7 times from 6.17 to 3.55 kWh/m3 based on seawater reverse osmosis 60 bar. In addition, the water intake process was divided into pre, inter, and post-according to the use method of blasting, and the water treatment process was divided into pre, inter, and post blending. In order to reduce power consumption, the blending process was combined to operate the facility, which resulted in the reduction of power consumption in the order post > pre-inter> inter blending.
        4,000원
        40.
        2018.11 구독 인증기관·개인회원 무료
        In this study, various physical cleaning methods such as physical washing and osmotic backwash, were performed to understand membrane fouling characteristics by employing real secondary wastewater effluent (SWWE). In addition, microfiltration (MF) and ultrafiltration (UF) pretreatments were compared to maximize removal of organic matter and to control membrane fouling efficiently. Organic foulants deposited on the active layer of FO membrane were observed by fouling behavior test. The relationship between concentrations of natural organic matter and membrane fouling was also investigated from the bench-scale FO tests. Finally, by quantitative analysis of correlations between foulants and fouling reversibility with the modified fouling index (MFI), we identified the applicability of MFI in predicting FO intake water fouling potential.
        1 2 3 4 5