This short review focuses on fouling by proteins and macromolecules in microfiltration/ultrafiltration. First, an experimental system that enables investigation of how the extent of the adsorption of proteins and macromolecules on membrane surfaces contributes to a decrease in filtrate flux in microfiltration/ultrafiltration is described. Using this system, a causal relationship - not a correlation - indicating that adsorption results in a decrease in filtrate flux could be clearly demonstrated in some cases. Second, a hydration structure at the membrane surface that can suppress adsorption is discussed, inspired by biomaterial research. In their hydrated states, polymers with low-fouling properties have water molecules with a particular structure. Finally, some successful examples of the development of low-fouling membranes via surface modification using low-fouling polymers are discussed.
Although membrane bio-reactor (MBR) has been widely applied for wastewater treatment plants, the membrane fouling problems are still considered as an obstacle to overcome. Thus, many studies and commercial developments on mitigating membrane fouling in MBR have been carried out. Recently, high voltage impulse (HVI) has gained attention for a possible alternative technique for desalting, non-thermal sterilization, bromate-free disinfection and mitigation of membrane fouling. In this study, it was verified if the HVI could be used for mitigation of membrane fouling, particularly the internal pore fouling in MBR. The HVI was applied to the fouled membrane under different conditions of electric fields (E) and contact time (t) of HVI in order to investigate how much of internal pore fouling was reduced. The internal pore fouling resistance (Rf) after HVI induction was reduced as both E and t increased. For example, Rf decreased by 19% when the applied E was 5 kV/cm and t was 80 min. However, the Rf decreased by 71% as the E increased to 15 kV/cm under the same contact time. The correlation between E and t that needed for 20% of Rf reduction was modeled based on kinetics. The model equation, E1.54t = 1.2 × 103 was obtained by the membrane filtration data that were obtained with and without HVI induction. The equation states the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increase of E.
본 연구에서는 가압식 분리막 여과에서 무기입자의 존재가 유기파울링에 미치는 영향을 관찰하였다. 유기파울링의 유발을 위해 알긴산나트륨(sodium alginate, SA)를 이용한 정밀여과 실험에서 무기 실리카(SiO2) 입자의 존재 유무와 상관 없이 분리막 파울링은 여과초기 완전공극막힘에서 여과시간이 경과할수록 케이크 형성에 의해 주로 지배되었다. 그러나 무기 입자의 존재 시 정압여과에서 알긴산나트륨 파울링 케이크 비저항값과 압축성은 상대적으로 낮게 관찰되었고 이로 인해 낮은 파울링 속도가 관찰되었다. 동일한 시료를 이용한 정량여과 실험을 수행한 결과 정압여과에 비해 정량여과에서 여과초기 공극막힘현상 및 파울링 속도는 더욱 증가하였다. 이와 같은 현상은 파울링층이 지닌 압축성으로 막간차압의 증가 시 케이크 비저항값이 함께 증가하였기 때문인 것으로 판단된다. 알긴산나트륨과 실리카 입자가 함께 존재 시 알긴산나트륨이 단독으로 존재하는 것보다 수리학적 세정을 통한 파울링 제거효과는 더욱 좋은 것으로 관찰되었다.
This study was aimed to examine inorganic fouling and fouling reduction method in direct contact membrane distillation(DCMD) process. Synthetic seawater of NaCl solution with CaCO3 and CaSO4 was used for this purpose. It was found in this study that both CaCO3 and CaSO4 precipitates formed at the membrane surface. More fouling was observed with CaSO4(anhydrite) and CaSO4・0.5H2O(bassanite) than CaSO4・2H2O(gypsum). CaCO3 and gypsum were detected at the membrane surface when concentrates of SWRO(seawater reverse osmosis) were treated by the DCMD process, while gypsum was found with MED(multi effect distillation) concentrates. Air backwash(inside to out) was found more effective in fouling reduction than air scouring.
As water resources are limited and legal regulations are strengthened, there is a growing need to reuse residuals in WTP(Water Treatment Plant). In this study, membrane filtration system was constructed and its operation method was studied for water quality stabilization and reuse of WTP residuals. The operation parameters were stable for 1 year and 6 months. Membrane fouling was identified as particulate pollution (activated carbon) and inorganic pollution (manganese). The membrane system was operated steadily with raw water of high concentration SS(Suspended solid) containing activated carbon because membrane fouling was reduced by the effect of End-Free type. In the case of inorganic contamination, dissolved manganese eluted by chemicals and acted as a membrane fouling source, and the operating conditions for minimizing membrane fouling were confirmed by newly developing application methods and types of cleaning chemicals. Based on the results, design parameters for reducing manganese membrane fouling were derived.
알루미나 콜로이드 용액의 막여과에서 막모듈의 중력에 대한 경사각 변화로 유발된 자연대류 불안정 흐름(natural convection instability flow, NCIF)의 콜로이드 물질의 막오염 제어 효과를 정압(constant-pressure) 막여과 시 플럭스 증가와 정투과량(constant-flux) 막여과 시 막차압 감소 정도로 측정하고, 플럭스 결과를 막힘여과 모델로 해석하였다. 막모듈의 경사각이 0°에서 180°로 커지면 NCIF 유발이 증가하여 막오염 제어 효과가 커져 2시간의 막여과에서 플럭스는 최대 2.8배까지 증가하고, 막차압은 최대 85%까지 감소하였다. 막힘여과 모델을 적용하여 NCIF의 유발에 따른 플럭스 결과를 해석하여 운전 시간 15분 이내에서는 중간막힘모델 그 이후에는 케이크여과모델로 평가하는 것이 타당하였다. 막모듈 경사각 180°에서 유발 된 NCIF는 15분 이내의 운전 초기에는 중간막힘 오염을 52% 감소시키고, 그 이후의 운전 시간에서는 케이크층 오염을 93% 감소시켰다. 따라서 막모듈에 유발된 NCIF의 주된 막오염 제어기작은 막표면에의 입자상 콜로이드 물질의 케이크층 형성을 억제시키는 것으로 평가하였다.
Electro-coagulation process has been gained an attention recently because it could overcome the membrane fouling problems in MBR(Membrane bio-reactor). Effect of the key operational parameters in electro-coagulation, current density(ρ i) and contact time(t) on membrane fouling reduction was investigated in this study. A kinetic model for ρi and t required to reduce the membrane fouling was suggested under different MLSS(mixed liquor suspended solids) concentration. Total 48 batch type experiments of electro-coagulations under different sets of current densities(2.5, 6, 12 and 24 A/m2), contact times(0, 2, 6 and 12 hr) and MLSS concentration(4500, 6500 and 8500mg/L) were carried out. After each electro-coagulation under different conditions, a series of membrane filtration was performed to get information on how much of membrane fouling was reduced. The membrane fouling decreased as the ρi and t increased but as MLSS decreased. Total fouling resistances, Rt (=Rc+Rf) were calculated and compared to those of the controls (Ro), which were obtained from the experiments without electro-coagulation. A kinetic approach for the fouling reduction rate (Rt/Ro) was carried out and three equations under different MLSS concentration were suggested: i) pi0.39t = 3.5 (MLSS=4500 mg/L), ii) pi0.46t = 7.0 (MLSS=6500 mg/L), iii) pi0.74t = 10.5 (MLSS=8500 mg/L). These equations state that the product of ρi and t needed to reduce the fouling in certain amounts (in this study, 10% of fouling reduction) is always constant.
BSA 용액의 전량 한외여과에서 막모듈의 중력에 대한 경사각(0~180°) 변화에 따라 유발된 자연대류 불안정 흐름 (natural convection instability flow; NCIF)의 막오염 제어 효과를 플럭스 증가 정도로 측정하고 막힘여과 모델로 해석하였다. 막모듈의 경사각이 0°에서 180°로 커질수록 NCIF 유발이 증가하여 막오염 제어 효과가 커져 플럭스가 증가하였다. NCIF의 유발이 가장 큰 경사각 180°에서의 플럭스 값을 NCIF의 유발이 없는 0°에서의 값과 비교한 결과, 2시간의 단기간 운전에서는 플럭스 향상성이 5배, 20시간의 장기간 운전에서는 17배까지 증가하였다. 막힘여과 모델을 적용하여 NCIF의 유발에 따른 플럭스 증가 효과를 해석한 결과, 운전시간 15분 이내에서는 중간막힘 모델 그 이후에는 케이크여과 모델로 해석하는 것이 타당하였다. 막모듈 경사각 180°에서 유발된 NCIF는 15분 이내의 운전 초기에는 중간막힘 오염을 67%까지 감소시키고, 그 이후의 운전 시간에서는 케이크층 오염을 99.9%까지 감소시켰다. 따라서 막모듈에 유발된 NCIF의 주된 막오염 제어 기작은 케이크층 형성을 억제시키는 것이었다.
하⋅폐수처리 MBR 공정을 운영함에 있어서 특정 오염물에 따른 멤브레인 회복률 저하를 자주 경험하게 되며, 이에 따른 화학세정 시 막오염 물질 제거에 필요한 약품선택에 많은 어려움을 겪는다. 본 연구의 목적은 하폐수 성상의 MBR 처리 시 발생할 수 있는 Ca 막오염에 대해서 다양한 세정약품 적용을 통한 멤브레인의 회복률 증대 방안을 찾고자 하는 것에 있다. 본 연구는 K 폐수처리시설에서 1년간 운영한 (주)에코니티의 분리막을 샘플링하여 투과도 측정 및 막표면 분석 후 막오염 물질을 우선적으로 확인하였으며, 이에 따른 각종 화학약품의 적용실험을 통하여 최적약품 도출 및 적용성을 평가하고자 하였다.
막증발 (Membrane Distillation, MD) 기술은 역삼투 해수담수화 공정에서 발생하는 농축수의 처리 문제를 해결하고 공정 회수율을 증가시킬 수 있는 차세대 담수화 기술로 부각되고 있다. 하지만 MD 공정의 효율적 운영을 위해서는, 막의 오염 (Fouling) 및 젖음 (Wetting) 현상을 해결하여야 한다. 이 현상들은, 해수 속에 존재하는 성분, 막의 종류 등을 포함한 여러 가지 운영 조건 등에 따라 다를 수 있다. 따라서 본 연구에서는 막오염과 막젖음 현상이 어떻게 발생하는지 살펴보기 위해, MD 공정 운영 조건을 변화시키며 막투수도 및 여과저항, 처리수 전도도 등을 측정하고, SEM-EDX, LEP (Liquid Entry Pressure) 등을 이용하여 막을 분석하였다.