검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 34

        21.
        2006.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of this work was to establish an optimal condition for determination of apparent density and flow rate for warm compacting powder. For this purpose it was evaluated uncertainty on them according to ISO Guide to the Expression of Uncertainty in Measurement. This evaluation example would be useful even in powder fluidity measurement at room temperature.
        4,000원
        24.
        2019.04 서비스 종료(열람 제한)
        A monitoring technique of ground anchor force is now studying by measuring the strains distributed on a bearing plate. These distributed strains are measured by a fiber optic OFDR (Optical Frequency Domain Reflectometer) sensor. A sensing optical fiber was attached on the bearing plate at the two radial locations and tested by a universal test machine. The anchor forces can be calculated from the differences of these two trains.
        25.
        2018.04 서비스 종료(열람 제한)
        Distributed optical fiber sensors have been developed to detect the occurrence of structural anomalies such as excessive stresses, cracks, and leaks at arbitrary locations in the facility. In this paper, we demonstrate fiber optic OFDR (Optical Frequency Domian Reflectometry) sensor to measure strain and temperature through the sensing optical fiber. A PVC pipe was prepared to show the strain measurement performance with a sensing optical fiber attached on the pipe. Also, a temperature test was performed with a sensing optical fiber located in a temperature chamber. In the results, this sensor can operate to resolve 14.2 micro strain and 1.62 degree temperature at the condition of 5 cm spatial resolution.
        26.
        2017.08 KCI 등재 서비스 종료(열람 제한)
        적외선 체열검사를 시행한 L4-L5 추간판 탈출증 환자의 45명 중 여자가 더 많았으며, 연령은 50대가 가장 많았다. 피절 분포표에 따라 측정한 결과,   에서는 성별과 나이에 따라서 유의한 차이를 보이지 않 았다(p>0.05). L4-L5 추간판 탈출증 환자의 ROI 온도를 측정한 부위는 후면 오른쪽 정강이뼈 뒤쪽의 온도 가 가장 높았으며, 후면 왼쪽 정강이뼈 뒤쪽-전면 오른 무릎아래-전면 왼 무릎아래의 순이었다. 측정부위에 따라 유의한 차이를 보였다(p<0.05). 나이에 따라서는   에서는 나이에 따라 0.030을 유의한 결과를 보였다(p<0.05). 정상인의 평균 ROI 온도는 31.20±0.58, 환자의 평균 ROI온도는 30.30±0.50으로 온도 차이는 0.66±0.59로 나타났다. 환자의 ROI온도가 정상인과 차이가 나는 지 알아보기 위한 일 표본 t-검정결과, 유의 확률이 0.03으로 0.05보다 작으므로 환자의 ROI온도는 31.20±0.58보다 낮게 나타났다(p<0.05). 앞으로의 과 제는 온열환경에 따른 보정 테이타의 처리기술과 그것을 이용한 새로운 온열 인덱스의 개발이 필요하다고 사료된다. 따라서 데이타의 보정을 줄이기 위해서는 적외선 체열 진단 시 전처치가 무엇보다 중요하며, 이 를 검사하는 방사선사는 환자를 측정 시 주의 깊은 관찰과 배려가 요구된다.
        27.
        2017.04 KCI 등재 SCOPUS 서비스 종료(열람 제한)
        본 연구에서는 토마토를 일정한 기간(15일) 동안 저장하여 토마토의 품질인자인 감모율, 색상과 경도를 분석하고 비 파괴적 방법으로 토마토 경도를 측정한 결과로 경도와 감모율 사이의 상관관계를 분석하고 선형회귀모델을 도출하여 토마토 품질을 예측하고자 하였다. 그린하우스에서 재배된 ‘티와이250’품종을 수확한 후 일반 과실 종이 박스에 포장한 후 설정환경이 10℃, 90%RH인 항온항습챔버에 저장하여 3일 간격으로 경도, 무게와 색상 변화를 조사하였다. 15일간 저장 중 감모율은 저장기간이 증가함에 따라 증가하나 1.1% 정도에 머물러 단순히 감모율 인자로만 판단했을 때 토마토의 신선도 품질에 영향 끼치는 수준은 아니다. 색상변화 중 명도와 색조 각은 저장기간의 증가에 따라 감소하는 경향을, a/b와 ΔE는 증가하는 경향을 나타냈었고 일원분산분석결과를 볼 때 유의한 수준이었다(p<0.001). 경도는 저장기간이 증가함에 따라 감소하는 경향을 나타냈으며 저장 15일차에는 경도감소율이 40% 이상인 것으로 나타났다. 그리고 비 파괴방법으로 측정한 경도 값과 감모율 사이의 상관관계를 분석하여 선형회귀모델 WL=-0.0241×F+1.5213을 하였으며 모델의 추정치 오차는 ±0.231이었다. 이러한 결과에 비추어볼 때 수확 후 일정한 저장환경에서 비파괴적인 경도 측정을 통해 감모율을 추정하고 신선도를 판단하는 지표고 사용하는 것이 가능한 것으로 판단되었다.
        28.
        2015.03 KCI 등재 서비스 종료(열람 제한)
        Recently, the event of slope failure has been occurring frequently due to rapid climate changes and broad development of infrastructures, and the research for establishment of monitoring and prevention system has been an attentive issue. The major influence factors of slope failure mechanism can be considered moisture and temperature in soil, and the slope failure can be monitored and predicted through the trend of moisture-temperature change. Therefore, the combined sensing technology for the continuous measurement of moisture-temperature with different soil depths is needed for the slope monitoring system. The various independent sensors for each item (i.e. temperature and moisture respectively) have been developed, however, the research for development of combined sensing system has been hardly carried out. In this study, the high-fidelity sensor combing temperature-moisture measurement by using the minimized current consuming temperature circuit and the microwave emission moisture sensor is developed and applied on the slope failure monitoring system. The feasibility of developed monitoring system is verified by various experimental approaches such as standard performance test, mockup test and long-term field test. As a result, the developed temperature-moisture combined measurement system is verified to be measuring and monitoring the temperature and moisture in soil accurately.
        29.
        2014.04 서비스 종료(열람 제한)
        The FBG sensor responses simultaneously to changes in thermal strain as well as elastic strain. Thus the total strain measured from a single FBG sensor shall be corrected to obtain the elastic strain by removing the temperature effect. This paper addresses how the temperature effect can be removed when the FBG sensor is encapsulated in a 7-wire steel strand. For this purpose, fundamental properties of the FBG sensor are identified through tests using a controlled temperature chamber. Then field measurements on a UHPC pi girder with the size of 11.0 m long, 5.0 m wide, and 0.6 m high have been conducted for about one year, and the prestressing force is estimated using the raw data from the FBG sensor and by applying temperature correction technique proposed in this study. Estimated results indicate that the proposed correction technique is executable for extracting the elastic strain from monitoring data using the FBG sensor in civil infrastructures.
        30.
        2013.04 서비스 종료(열람 제한)
        In this study trying to develop a monitoring system for temperature and humidity measurement of quality control methods suitable for curing concrete nuclear power plant structures. This experiment is divided part of data logger, sensors, control program in a accordance with standar of quality control Nuclear power plant hot weather/the middle of summer. This measuring method is expected to development quality control nuclear power plant
        31.
        2012.12 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목표는 신발 굽 높이에 따른 Kager씨 삼각 면적의 방사선영상 변화와 후종족부의 표면온도 변화를 알아보고자 연구하였다. 카이거씨 면적은 단순 방사선촬영검사와 인피니티 영상저장전송시스템을 이용하여 측정 하였다.후종족부의 표면온도는 전산화적외선체열검사를 이용하여 측정하였다. 운동화 착용 대상자에게 신발 굽 높이가 다른하이힐을 착용시켜 카이거씨 삼각 면적과 후종족부의 표면온도 차이를 분석 하였다. 하이힐 대상자들은 운동화 대상자들에 비하여 카이거씨 삼각 면적이 0.88cm², 후종족부의 표면온도가 1.4℃ 각각 감소하였다. 최고신장과 최저신장의 카이거씨 면적과 표면온도의 차이는 운동화와 하이힐에서 각각 0.9cm²,1.2cm²,1.6℃,0.5℃이며 모두 미세한 차이를 나타냈다. 최고체중과 최저체중의 카이거씨 면적과 표면온도의 차이는 운동화와 하이힐에서 각각 1.8cm²,0.8cm²,1.1℃,0.2℃이며 체중이 높을수록 카이거씨 면적과 표면온도가 감소하였다. 하이힐 최장시간 착용자와 최저시간 착용자의 카이거씨 면적과 표면온도의 차이는 각각 0.8cm², 1.4℃, 이며 착용시간이 증가함에 따라 카이거씨 면적과 표면온도가 감소하였다. 결론적으로 하이힐을 장시간 착용하면 후종족부 통증과 혈류 장애를 유발 할 것으로 고려된다.
        32.
        2012.09 KCI 등재 서비스 종료(열람 제한)
        본 연구는 타설 콘크리트의 온도를 무선센서 방식으로 현장에서 직접 간편하게 계측할 수 있는 장치를 개발하고, 무선 전송네트워크시스템을 통하여 현장사무실 및 본사 등에서 실시간 효율적 온도이력관리를 할 수 있는 시스템을 구축하는데 목적이 있다. 실험결과, 우선 무선센서네트워크시스템의 기본이 되는 온도센서는 콘크리트 타설시 안정적으로 측정될 수 있도록 무선방식의 막대타입의 스텐레스 프로브형으로 제작하였으며, 거푸집에서의 탈부착이 간편하고 장기간의 내장전력공급이 가능한 거푸집일체형의 무선센서네트워크 장치를 개발하였다. 또한 무선센서네트워크시스템의 구성은 센서노드와 라우터, 게이트웨이 및 CDMA 통신방식으로 구성하였으며, 콘크리트의 동일한 양생조건 및 상이한 양생조건에서 온도를 측정한 결과, 기존의 유선방식과 동일한 온도분포를 보였다. 향후, 개발된 무선센서네트워크 장치를 현장에서 사용할 경우, 현장 사무실에서의 정량적인 콘크리트 온도관리가 효율적으로 이루어 질 것으로 판단되며, 감리 감독업무의 생산성 향상과 더불어 전반적인 콘크리트 구조체의 품질에 크게 기여할 것으로 판단된다.
        33.
        2009.03 KCI 등재 서비스 종료(열람 제한)
        교량 지지용으로 사용되는 강재 케이블에 대한 장력측정은 교량 안전관리의 중요한 측정항목이다. 현재 케이블에 걸린 장력을 진동법과 로드셀로 측정하고 있으며, 최근에는 선진국에서 자기적 방식에 의한 장력측정 방법을 연구하여 이에 대해 여러 가지 결과물을 제공하고 있다. 그러나 아직 우리나라에서는 이에 대한 체계적인 연구가 수행되지 않고 있어 자기적 방식에 의한 장력측정 연구를 시작하였으며 장력측정 정밀도 향상을 위해 연구하고 있다. 자기적 방식의 장력측정에서 강재 케이블 내의 온도와 자기장에 대한 영향을 검토해야 한다. 금번 논문에서는 온도에 따라 장력센서의 출력특성을 시험하였고 주어진 자기장에서 온도보정계수를 도출하였으며 시험실 내의 장력측정 시스템에 보정계수를 적용하여 케이블 장력에 따른 장력센서의 출력특성에 대한 시험 결과를 분석하고 평가하였다.
        34.
        1997.09 KCI 등재 서비스 종료(열람 제한)
        It is very important to measure and monitor hull stress which is caused by a buoyant force and a weight of cargo for safety of ship. However, an exact measurement of hul stress, using the traditional strain gage which is made of metal or semiconductor, is very difficult, because a ship would be exposed by the severe temperature environment of -20 ℃ to 80 ℃. This paper propose a new concept strain gage which can improve accuracy and compensage effectively affects due to temperature. The strain gage is consists of two parts. One is the Hull Deformation Amplifier which introuce several lever and link system, and another is a transducer converting distance into voltage signal. The HDA measure the amount of deformation and amplify it. And a lever and link system of the HDA is introduced for compensating temperature deformation by installing in perpendicular direction without stress. This paper also reports on the results of the experiments to verify linearity of the strain gage.
        1 2