검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 382

        101.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigates application cases of facility management system model for enhancing facility productivity of industry filed around medium and small facility processing companies and finds the inefficiency of the existing management model. Following items are researched to seek out methods and measures to maximize facility productivity through empirical analysis by exploring and establishing a new management model. First, the empirical analysis, it is found that the overall equipment efficiency index used for facility productivity management in the companies has a difficulty being used as the index for it in actual medium-small processing companies. Second, a new facility management system model applying standard cycle time is suggested among facility management index system to measure facility productivity. Third, the empirical analysis is used to verify that developed facility management system model is a useful method to manage the facility productivity by applying the model to actual medium-small processing companies. Finally, it is necessary to implement comparison analysis on whether actual productivity enhancement induces a distinctly different result by using a new facility management index system model to be inhibited in this study.
        4,000원
        102.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Currently, the number of a shopping center building is increasing because most people want to go a shopping center building easily for buying many things and eating some foods. That are a normal trend these days. However, the increasing number of shopping center buildings has been increasing the number of shopping center building fires which also have been making social problems. Therefore, this study was conducted for the fire department connection among other fire facilities because it is important for fire suppression. The research subject is on the fire department connections that are on 70 shopping center buildings of more than 5 years old constructed. Survey and analysis were conducted for 70 fire department connections. The result of this study is that all installed fire department connections have a type that includes one or two holes each at 65mm wide, and the average distance between fire department connections and access roads is 4.85m. The total average percentage of insufficiency conditions such as drive ways for fire trucks, visibility, accessibility, pressure range sign, installed height, cover of the hole, etc. is 45.3%. So improvement of law and systems, that are fire facility construction and maintenance implementations, will be needed in my opinion.
        4,000원
        105.
        2016.11 구독 인증기관 무료, 개인회원 유료
        Pumps for hazardous materials handling areas of self service stations are still scattered in the country, generator room, engine room of the small vessels, etc. are installed inside buildings against big is the risk of fire extinguishers are installed only. These facilities are in severe climate change because it is an open space area, as well as a water based fire extinguishers may not be suitable for that type of gas extinguishing system is also adaptable. This study features a compressed air port operation principles and characteristics, equipment, fire extinguishers, which can minimize the casualties and property losses from fire against hazardous substances in small business, design requirements, domestic contain fire extinguishers laws and foreign Compression Four fire extinguishers through the air and foreign regulations comparative analysis of the compressed air port installations such as fire extinguishers and applied to study the measures to be included are fire extinguishers installed in the country. Climate change is a big country review In winter, water based fire extinguishers are also concerned about the freeze, but compared to the foreign installations were exploring ways to work in the country. CAF is especially preferred that the fire extinguishing performance and to demonstrate the protective space as there is a risk of frost risk significantly less compressed air port digestion plant.
        5,100원
        110.
        2016.04 구독 인증기관 무료, 개인회원 유료
        The research on improvement of false alarm from the automatic fire detection system has been continually achieved in the meantime. But the research for the code-transmitter as one of component devices of the automatic fire detection system. In order to improve difficulty of the code-transmitter check-up, introduction for the address type-code-transmitter and the automatic recovery system for check up of the code-transmitter was proposed. In order to prevent against occurrence of noise and signal attenuation, introduction of the optical fiber cables that noise and signal attenuation do not occur and introduction for an optical communication relay that can apply to was proposed respectively.
        3,000원
        112.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Semiconductor manufacturing has suffered from the complex process behavior of the technology oriented control in the production line. While the technological processes are in charge of the quality and the yield of the product, the operational management is also critical for the productivity of the manufacturing line. The fabrication line in the semiconductor manufacturing is considered as the most complex part because of various kinds of the equipment, re-entrant process routing and various product devices. The efficiency and the productivity of the fabrication line may give a significant impact on the subsequent processes such as the probe line, the assembly line and final test line. In the management of the re-entrant process such as semiconductor fabrication, it is important to keep balanced fabrication line. The Performance measures in the fabrication line are throughput, cycle time, inventory, shortage, etc. In the fabrication, throughput and cycle time are the conflicting performance measures. It is very difficult to achieve two conflicting goal simultaneously in the manufacturing line. The capacity of equipment is important factor in the production planning and scheduling. The production planning consideration of capacity can make the scheduling more realistic. In this paper, an input and scheduling rule are to achieve the balanced operation in semiconductor fabrication line through equipment capacity and workload are proposed and evaluated. New backward projection and scheduling rule consideration of facility capacity are suggested. Scheduling wafers on the appropriate facilities are controlled by available capacity, which are determined by the workload in terms of the meet the production target.
        4,000원
        113.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A fire sprinkler system is very important to extinguish fire in the building. The sprinkler system initiates sprinkler discharge if the detection system identifies a developing fire and opens the pre-action valve. However, pre-action fire sprinkler systems mainly installed in the underground parking lot at the apartment complex do not properly operate at fire if the connection type of fire sprinkler systems does not properly installed and operated. This study identified the relationship between fire dispersion & damage and the connection type of water supply in the sprinkler system from many fire cases at the apartment complex in South Korea. In addition, this study also identified the water supply differences and characteristics between South Korea and foreign countries. The main purpose of this study is also to improve the water connection types in the sprinkler system that can reduce the potential failures of pre-action valve operation through electrical signal system. The study also suggests the improvement plan for water connection types in pre-action fire sprinkler system that can minimize potential failure of pre-action fire sprinkler system. The suggestions for revising the fire safe standard in South Korea includes letting the water supply pipe of sprinkler system water inlet connect to the second side of pre-action valve and the water flow device that can minimize potential failure of sprinkler system.
        4,000원
        115.
        2015.11 구독 인증기관 무료, 개인회원 유료
        The goals of automatic fire detection equipment in Japan and South Korea are the detection in early fire stage, alarm and finding the location of the fire. Japan also has similar operation system and signal transmission method compared with South Korea. The standards of fire detection equipment in Japan are established their own standards. The automatic fire detection equipment in Korea has been developed with benchmarking the Japanese system in early 1950’s and follows the decree on the basis of Japan’s fire services. NFPA 72, which is automatic fire detection equipment in U.S.A. and verified through the experiment and test, expects to reflect to our automatic fire detection equipment after modification and supplement.
        4,000원
        116.
        2015.11 구독 인증기관 무료, 개인회원 유료
        시멘트제조공정에서 중요공정인 슬래그 미분말 공정 중에서 분슬래그 이송공정 정 지시간을 조사해 보니 84.6% 차지하여 생산성의 매우 낮은 실정이라 시급히 개선이 요구 되어 QC 문제해결 과정을 통해 개선전 3.45 (h/일)에서 개선후 1.09 (h/일)으로 낮 추어 연간 5400만원을 절감하였다.
        4,500원