The purpose of this study is to develop a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were experimentally performed on one unreinforced beam-column specimen and two reinforced specimens with L-type precast wall panels. The results were analyzed to find that the specimen with anchored connection experienced shear failure, while the other specimen with steel plate connection principally manifested flexural failure. The ultimate strength of the specimens was determined to be the weaker of the shear strength of top connection and flexural strength at the critical section of precast panel. In this setup of L-type panel specimens, if a push loading is applied to the reinforced concrete column on one side and push the precast concrete panel, a pull loading from upper shear connection is to be applied to the other side of the top shear connection of precast panel. Since the composite flexural behavior of the two members govern the total behavior during the push loading process, the ultimate horizontal resistance of this specimen was not directly influenced by shear strength at the top connection of precast panel. However, the RC column and PC wall panel member mainly exhibited non-composite behavior during the pull loading process. The ultimate horizontal resistance was directly influenced by the shear strength of top connection because the pull loading from the beam applied directly to the upper shear connection. The analytical result for the internal shear resistance at the connection pursuant to the anchor shear design of ACI 318M-11 Appendix-D except for the equation to predict the concrete breakout failure strength at the concrete side, principally agreed with the experimental result based on the elastic analysis of Midas-Zen by using the largest loading from experiment.
This study aims at developing a new seismic resistant method by using precast concrete wall panels for existing low-rise, reinforced concrete beam-column buildings such as school buildings. Three quasi-static hysteresis loading tests were performed on one unreinforced beam-column specimen and two reinforced specimens with U-type precast wall panels. Top shear connection of the PC panel was required to show the composite strength of RC column and PC wall panel. However, the strength of the connection did not influence directly on the ultimate loading capacities of the specimens in the positive loading because the loaded RC column push the side of PC wall panel and it moved horizontally before the shear connector receive the concentrated shear force in the positive loading process. Under the positive loading sequence(push loading), the reinforced concrete column and PC panel showed flexural strength which is larger than 97% of the composite section because of the rigid binding at the top of precast panel. Similar load-deformation relationship and ultimated horizontal load capacities were shown in the test of PR1-LA and PR1-LP specimens because they have same section dimension and detail at the flexural critical section. An average of 4.7 times increase in the positive maximum loading(average 967kN) and 2.7 times increase in the negative maximum loading(average 592.5kN) had resulted from the test of seismic resistant specimens with anchored and welded steel plate connections than that of unreinforced beam-column specimen. The maximum drift ratios were also shown between 1.0% and 1.4%.
RC shear wall sections which have irregular shapes such as T, ㄱ, ㄷ sections are typically used in low-rise buildings in Korea. Pushover analysis of building containing such members costs a lot of computation time and needs professional knowledge since it requires complicated modeling and, sometimes, fails to converge. In this study, a method using an equivalent column element for the shear wall is proposed. The equivalent column element consists of an elastic column, an inelastic rotational spring, and rigid beams. The inelastic properties of the rotational spring represent the nonlinear behavior of the shearwall and are obtained from the section analysis results and moment distribution for the member. The use of an axial force to compensate the difference in the axial deformation between the equivalent column element and the actual shear wall is also proposed. The proposed method is applied for the pushover analysis of a 5- story shear wall-frame building and the results are compared with ones using the fiber elements. The comparison shows that the inelastic behavior at the same drift was comparable. However, the performance points estimated using the pushover curves showed some deviations, which seem to be caused by the differences of estimated yield point and damping ratios.
전단벽-골조 구조시스템의 구조적인 거동은 휨거동하는 전단벽과 전단거동하는 골조의 상호작용에 의하여 결정된다. 이러한 전단벽-골조 구조물의 거동특성을 효과적으로 고려하기 위하여 선행 연구에서는 2차원 T형 강체를 사용한 단순 해석 모델을 제안하였다. 본 논문에서는 이를 바탕으로 편심코어를 가진 전단벽-골조 구조물에 대한 효율적인 해석모델을 제안한다. 2차원 등가모델을 3차원으로 확장하여 비틀림 거동을 고려할 수 있도록 하였고, 그 결과 제안하는 등가모델이 편심코어를 가지는 전단벽-골조 구조물에도 적용가능 하도록 하였다.
본 연구에서는 고층 전단벽-골조 구조시스템의 효율적인 해석모델을 제안하였다. 전단벽-골조구조시스템은 휨거동하는 전단벽과 전단거동하는 골조로 구성된다. 그리고 전단벽-골조구조시스템의 변형형상은 골조와 전단벽의 상호작용으로 결정된다. 효율적인 해석모델에서는 이러한 거동특성을 반영되어야 하므로 골조와 전단벽을 분리하여 동적인 거동특성을 반영할 필요가 있다. 본 연구에서는 벽체부와 골조부를 분리하기 위하여 T형 강체를 전단벽의 위치에 대체하는 방법을 사용하였다. 분리한 벽체부와 골조부 각각의 등가모델을 구성한 후 결합시키는 방법으로 고층 전단벽-골조구조시스템의 등가모델을 완성하였다. 제안한 등가모델의 정확성과 효율성을 검증하기 위하여 고층의 전단벽-골조 구조물의 시간이력해석을 수행하였고, 그 결과 제안한 등가모델이 해석시간과 컴퓨터 메모리를 현저하게 줄이면서도 정확한 결과를 도출하였다.
The interest for the stability of the structures against earthquake, which is increasing recently, is rapidly increasing. But, currently, school buildings among the reinforced concrete(RC) structures in Korea are not designed with seismic design or there are many cases of being designed with the old seismic design code, so it is estimated to have not only lives but also a great deal of economic damage are likely to occur when an earthquake occurs. In this study, proposed horizontal friction system(HFS) with rotary friction damper installed as a method to reinforce strength and hardness and to increase ductility for the low story structure of 5 stories or lower such as school buildings. For the seismic retrofitting design with horizontal friction system in which rotary friction damper is installed, Peak displacement response ratio according to elastic and inelastic behavior and ductility demand is calculated to decide elastic stiffness and strength of the HFS, design model and procedure to decide the capacity of HFS thereof is decided, and the feasibility and performance are reviewed through pushover analysis.
고정반복법에 의한 암시적 HHT 시간적분법을 이용하여 3층 3경간 철근콘크리트 골조구조물을 수치해석모형과 물리적 분구조모형으로 나누어 실시간 하이브리드실험을 실시하였다. 물리적 부분구조모형으로는 1층 내부 비연성기둥 1개소가 선택되었고, 수치해석모형에 일축 방향의 지진하중을 시편이 심한 손상에 의하여 파괴에 이를 때까지 작용시켰다. 비선형 유한요소해석 프로그램인 Mercury가 실시간 하이브리드실험을 위하여 새로이 개발 및 적용되었다. 실험결과는 물리적 부분구조모형의 상부 수평방향 층간변위비를 OpenSees에 의한 수치해석시뮬레이션과 진동대실험의 그것과 비교하였다. 본 실험은 가장 복잡한 실시간 하이브리드실험 중의 하나이고, 하드웨어, 알고리즘 그리고 모형에 대한 기술적인 내용을 본 논문에 자세히 설명하였다. 수치해석모형의 개선, 물리적 부분구조 모형 접선강성행렬의 유한요소해석 프로그램에서의 평가 그리고 하중기반 보-요소의 요소상태결정의 연산시간을 줄이기 위한 소프트웨어의 개선이 이루어진다면 실시간 하이브리드실험과 진동대실험결과의 비교는 권장할 만하다. 그리고 "지진과 같은 동적하중하의 복잡한 구조물의 수치해석시뮬레이션"이라는 목적을 위하여 실시간 하이브리드실험은 동적하중에 대한 실험적 검증을 점진적으로 수치해석모형으로 대체하기 위한 저비용-고효율 실험법으로서의 가치를 충분히 가지고 있다고 할 수 있다.
본 연구에서는 복강판-모듈러 시스템과 같이 구조 기준에 명시되지 않은 새로운 시스템의 반응수정계수를 산정하는 절차를 제안하였다. 기본 개념은 구조성능 실험결과를 바탕으로 모델링 된 시스템의 비선형 정적 해석 곡선으로부터 세부 구성요소인 초과강도계수와 연성계수의 도출하고, 단자유도 시스템으로 간주하고 평가된 반응수정계수를 다자유도 동적 거동을 고려한 다자유도 밑면전단 수정계수로 수정하여 시스템의 최종적인 반응수정계수를 결정하는 것이다. 제안한 절차에 따라 이중골조시스템으로 설계된 2층부터 5층까지의 복강판-모듈러 시스템에 대해 평가한 결과, 최종적인 반응수정계수는 5층(층고 4m기준)을 복강판-모듈러 시스템의 적용 가능한 층수의 상한으로 하여 4로 결정하는 것이 타당할 것으로 판단하였다.
본 연구에서는 지진하중을 받는 고층 RC 골조구조물의 횡변위를 정량적으로 제어할 수 있는 방안을 제시한다. 이를 위해 수학적인 일반성을 가지면서 큰 규모의 문제도 효율적으로 다룰 수 있는 근사화 개념을 도입하여 횡변위 구속조건식을 설정한다. 아울러 구조부재의 단면특성 관계식을 설정함으로써 설계변수의 수를 줄여주고, 초기에 주어진 단면형상이 최적설계 과정동안 계속 유지된다는 가정을 이용하여 최적설계결과에서 구해진 단면특성에 따라 부재단면크기를 산출하는 방안을 강구한다. 특히 근사화된 횡변위구속조건식을 정식화 하기 위해 동적 변위민감도해석 방안이 고려된다. 이와 같이 제시된 동적 강성최적설계 기법의 효용성을 검토하기 위해 10층과 50층 규모의 삼차원 RC 골조구조물 모델이 고려된다.
유전자 알고리즘은 가장 훌륭한 이산최적화 기법 중 하나이다. 그러나, 유전자 알고리즘은 무제약 최적화 기법이기 때문에 제약조건은 간접적으로 표현된다. 가장 일반적인 방법은 벌칙함수를 사용하여 제약 문제를 무제약 문제로 변환하는 것이다. 본 연구에서는 적합도에 벌점함수를 적용하여 거부전략, 벌점전략, 복합전략 등에 따른 3가지 함수를 구성하였다. 그리고, 이 적합도 함수들을 사용한 설계프로그램을 구현하고, 산형골조와 2층 3경간 골조의 설계문제에 적용시켜 설계결과를 비교하였다. 이를 통하여 유전자 알고리즘을 이용한 유용한 골조 설계프로그램의 구현이 가능할 것으로 판단된다.
최근 도심지에 건설되고 있는 대부분의 주상복합건물과 아파트들은 다양한 공간을 구성하기 위해 주로 복합구조형식을 채택하고 있다. 특히, 이러한 구조형식들 중의 하나인 상부벽식-하부골조시스템은 전이층에서 서로 연결되는 전단벽형식과 골조형식을 모두 포함하고 있다. 그러나 이 시스템은 구조적인 안전성 측면에서 볼 때 매우 불합리하며, 전이층에서의 응력분포를 파악하기 매우 어렵다. 따라서 본 연구에서는 연직 및 정적 횡하중이 작용하는 전이보 시스템의 전단벽 배치에 따른 구조적인 거동과 응력분포를 분석하고자 함에 있으며, 또한 해석결과를 바탕으로 전이층부근에서의 하중의 전달경로 및 응력집중현상을 파악하고, 전단벽과 전이보의 효율적인 설계를 위한 방안을 제시하고자 한다.
파양한 구조물의 정적해석에서 매트릭스구조해석법은 가상 폭넓게 사용되고 있는 강력한 해석기법이다. 그러나 이 방법으로 많은 수의 자유도를 갖는 구조물을 정확히 해석하기 위해서는 많은 계산 메모리와 빠른 처리 능력을 갖춘 고성능 컴퓨터를 필요로하는 취약점이 있다. 따라서 매트릭스구조해석법으로 많은 수의 자유노를 갖는 구조물을 퍼스널 컴퓨터 상에서 정확히 해석하기에는 곤란한 경우가 많다. 매트릭스구조해석법치 이러한 취약점을 극복하기 위하여, 저자들은 전달강성계수법을 제안한다. 전달강성계수법은 해석대상 구조물에 대한 강성계수의 전달에 기본 개념을 두고 있으am로 퍼스널 컴퓨터에 매우 적합한 해석기법이다. 본 논문에서는 골조추조물에 대한 정적해석 알고리듬을 전달강성계수법으로 정식화한다. 그리고 전달강성계수법, NASTRAN, 매트릭스구조해석법 그리고 해석해에 의한 계산 결과들의 비교를 통해 전달강성계수법의 유효성을 확인한다.
내부튜브를 가진 튜브 구조물의 보에 있는 전단응력을 평가하기 위하여 수치적인 해석기법이 제안되었다 이 기법은 휨과 전단변형을 고려한 튜브 보 개념 위에서 각각의 튜브를 연속 보로서 모델링 한다. 전단응력에 대한 수치해석은 패널에 작용하는 응력에 대한 탄성이론과 수학적인 유도를 기초로 하고 있다. 내부와 외부 튜브에 있는 변형곡선에 대한 표현식을 가정함으로써, 그 튜브에 있는 전단응력은 작용하중과 단면 2차 모멘트 그리고 구조물의 기하학적인 표현으로 구성된 선형 함수로서 표현된다 전단지체와 축 응력을 다룬 이전의 연구가 튜브내에 존재하는 전단응력을 수치적으로 해석하기 위하여 보완 발전되었다. 제안된 방법의 정확성과 유용성이 3개의 튜브 구조물의 해석을 통하여 증명 되었다
상부벽식-하부골조 구조(복합구조)는 일반적으로 전이층을 중심으로 상부는 주거공간의 전단벽식의 고층아파트이고 하부는 상업공간의 보-기등의 골조구조이다. 이러한 구조물은 구조형식의 특성상 강성비정형, 질량비정형, 기하학적 비정형 등 비정형 형태의 특징을 갖고 있다. 본 연구에서는 하부골조 구조물의 층수가 변화할 경우에 대해 복합 구조물의 비선형 거동특성과 내진성능을 파악하였다. 비선형 해석결과로부터 얻은 결론은 다음과 같다. 1) 비선형 정적해석의 최상층변위각과 밑면전 단력계수로부터 하부구조의 층수가 증가할 경우 구조물의 밑면전단력계수는 감소하였으나 최상층변위각은 증가하였다. 2) 하부구조의 층수가 증가할 경우 상부벽식구조의 층간변위각과 소성율은 감소하였으며, 상부벽식은 탄성상태에 가까운 거동을 하였다. 3) 하부구조의 층수가 증가할 경우 하부구조에서 층간변위각이 집중적으로 증가하였다.
상부벽식 하부골조를 가진 복합구조물은 부족한 대지를 효율적으로 활용하기 위하여 건설되고 있다. 이러한 복합건물은 상부벽식-하부골조를 가지는 구조로써 일반적으로 전이보 또는 전이판으로 상하부를 연결하고 있다. 따라서 상하부 구조사이의 강성과 질량에 많은 차이가 발생하게 된다. 구보물의 고유주기는 지진하중과 밑면전단력을 결정하기 위한 중요한 변수이다. 그러나 현재 국내 규준에서 제안하는 고유주기 산정식은 이러한 건물에는 적용할 수 없다. 본 연구에서는 상부벽식-하부골조를 가진 복합구조물의 고유주기의 산정에 영향을 미치는 변수들 중 가장 큰 영향을 미치는 건물의 상하부 층수에 따른 변수만을 고려하여 고유주기산정식을 제안하였다. 하부는 2~5개 층을 가지고, 상부는 10~18개 층을 가지는 15~20층의 건물이면 정형적인 평면을 가지는 복합구조물로 한정하였다. 건물 내부의 채움벽에 대한 효과를 고려한 고유주기 제안식은 다음과 같다. 장변 방향 : T_{L}=(0.20H_{h}+0.05H_{i})/sqrt{B}-0.42 단변 방향 :T_{S}=(0.07H_{h}+0.12H_{i})/sqrt{B}-0.40
복수의 내부튜브를 가진 골조 튜브 시스템의 전단지체 영향을 평가하기 위하여 수치적인 모델링 기법이 제안되었다. 이러한 튜브 구조물의 모든 튜브는 전단지체 영향 뿐만 아니라 휨과 전단변형의 영향을 설명할 수 있는 보로 각각 모델링된다. 수치적인 해석은 최소 포텐셜 에너지 원리에 근거한 변분 접근법에 기초한다. 복수의 내부튜브를 가진 튜브 구조물의 전단지체 현상이 부가적인 휨 응력에 의해서 조사되었다. 또한 튜브 구조물의 전단지체를 지배하는 구조변수를 연구하기 위하여 33개의 튜브구조물이 해석되었다.
기초 지반상에 존재하는 3차원 골조구조물에 진동을 유발시키는 기계하중, 풍하중, 지진과 같은 동적 하중이 작용한다면, 지반-골조구조물 상호작용계의 동적거동을 해석하여야한다. 따라서, 본 연구에서는 실제 구조물에 근접한 기하학적 형상으로 이상화 시키기 위해, 슬래브와 기초판은 유연성을 갖는 4-절점 판요소, 보.기둥은 2-절점 보요소, 탄성지반은 8-절점 입체요소를 사용하여 유한요소법으로 3차원 상호작용계를 해석하였다. 본 연구의 목적은 지반-골조구조물 상호작용계의 동적 거동을 해석하기 위해, 동적 운동 방정식을 정리한 후 유한요소 프로그램으로 상호작용계의 동적 거동을 해석하는 것이다.
본 연구에서는 이상화구조요소법을 적용하여 골조구조물의 비선형해석을 높은정도로서 짧은 계산시간에 수행할 수 있는 해석이론과 컴퓨터프로그램을 개발하였다. 이를 위해 골조구조물을 구성하는 보-기둥(Beam-Column)부재에 대한 이상화구조요소를 부재에 존재하는 초기결함의 영향도 고려하여 정식화한다. 요소의 접선탄성강성행렬은 에너지원리를 적용하여 명시적인 형태로 도출하며, 최종강도조건은 요소에 소성붕괴메카니즘이 형성될때를 기준으로 정식화한다. 또한, 요소의 최종강도후 강성행렬도 근사적인 방법을 이용하여 명시적인 형태로 도출한다. 본해석법의 정도와 유용성은 단위부재 및 골조구조모형에 대한 기존의 실험 및 수치해석결과등과 비교하여 확인한다.