검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 26

        1.
        2017.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to establish a seismic resistance performance evaluation method that makes sure to secure the seismic resistance performance of the existing mid-low story reinforced concrete structures. This study focuses on the development of the seismic resistance performance evaluation method for the overall seismic resistance performance evaluation on the buildings by applying fuzzy theory. This seismic resistance performance evaluation method considers the mutual relations among the type of force, the type of member, the type of story, and the states of deterioration of the buildings. The total seismic resistance performance index from this method was calculated by the intensity weight of each evaluation item, fuzzy measure, fuzzy integration. Moreover, the evaluation methodology was established in this study to identify the performance level of the Immediate Occupancy, Life Safe, Collapse Prevention by applying the fuzzy theory.
        4,000원
        2.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Nonlinear analysis for seismic performance evaluation of existing building usually takes 4~5 times more than linear analysis based on KBC code. To obtain accurate results from the nonlinear analysis, there are a lot of things to be considered for nonlinear analysis modeling. For example, reinforcing layout, applied load and seismic details affect behavior of structural members for the existing building. Engineer-oriented computerized system was developed for engineers to evaluate effective seismic performance of existing buildings with abiding by seismic design principles. Using the engineer-oriented program, seismic performance evaluation of reinforced concrete building was performed. Nonlinear hinge properties were applied with real time multiple consideration such as section layout, section analysis result, applied load and performance levels. As a result, the building was evaluated to satisfy LS(Life Safety) performance level. A comparison between engineer-oriented and program-oriented results is presented to show how important the role of structural engineer is for seismic performance evaluation of existing buildings.
        4,000원
        3.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seismic performance evaluation of existing building usually needs much time and man power, especially in case of nonlinear analysis. Many data interaction steps for model transfer are needed and engineers should spend much time with simple works like data entry. Those time-consuming steps could be reduced by applying computerized and automated modules. In this study, computational platform for seismic performance evaluation was made with several computerized modules. StrAuto and floor load transfer module offers a path that can transfer most linear model data to nonlinear analysis model so that engineers can avoid a lot of repetitive work for input information for the nonlinear analysis model. And the new nonlinear property generator also helps to get the nonlinear data easily by importing data from structural design program. To evaluate the effect of developed modules on each stages, seismic performance evaluation of example building was carried out and the lead time was used for the quantitative evaluation.
        4,000원
        4.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        There are only 10 projects of the domestic greenhouse gas(GHG) emissions trading scheme in building sector (i.e., 1.5% of 652 registered projects) because the certified methodologies to reduce GHG emissions can not be applied to building sector. This study presents remodeling techniques to reduce GHG emissions in existing buildings. First of all, preconditions and related regulations were reviewed. And then, a pool of factors for GHG reduction are selected and evaluated with respect to factors for reducing energy consumption. This study also investigates the criteria and the decision making process for remodeling techniques to reduce GHG emissions. Finally, the remodeling techniques using the decision making process were grouped based on redundancy of each effect. If reducing methodologies for GHG offset program can be developed using the analyzed remodeling techniques in this study, registered projects in building sector would be increase.
        4,000원
        5.
        2013.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper deals with steel braced frame as increasing the lateral strength and ductility in order to seismic retrofit of existing buildings and discusses the designing criteria and calculation method of retrofitted buildings. The addition of steel braced frame can be effective for increasing the lateral strength and ductility of existing buildings. However, There is a problem in utilizing this method. It is the approach to provide an adequate connection between the existing RC frame and the installed steel braced frame, because global strength by failure mode(three type) depends on detail of connection and strength of existing RC frame. So, the designer must be confirmed if it satisfies the required performance or not. Failure mode of type I is the most appropriate for increasing the lateral strength and ductility. Seismic performance evaluation and strength calculation of seismic retrofit are performed by guideline by KISTEC(Korea Infrastructure Safety & Technology)’s “seismic performance evaluation and rehabilitation of existing buildings” and Japan Building Disaster Prevention Association. Buildings are modeled and non-linear pushover analysis are performed using MIDAS program.
        4,200원
        6.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The core aim of this paper is to empirically scrutinize a strength characteristic and ductility of the beam-column frame of reinforced with steel subjected to the cyclic lateral load. First and foremost, I the author embarks upon making four prototypes vis-à-vis this research. Through this endeavour, the author has analysed cyclic behavior, fracture shape, ductility and energy dissipation of the normal beam-column frame and a beam-column frame of reinforced with steel. In addition, the survey has revealed the exact stress transfer path and the destructive mechanism in order to how much a beam-column frame of reinforced with steel has resistance to earthquake regarding all types of building, as well as school construction. To get the correct data, the author has compared the normal beam-column frame and three types of the beam-column frame of reinforced with steel following these works, the characteristic of cyclic behavior, destructive mechanism, ductility, and Energy dissipation of normal beam-column frame and a beam-column frame of reinforced with steel have been examined clearly.
        4,200원
        7.
        2009.03 구독 인증기관 무료, 개인회원 유료
        In this study, the seismic performance of RC school buildings which were not designed according to earthquake-resistance design code were evaluated by using response spectrum and push-over analyses. From the results of analysis, the efficiency of the seismic retrofitting methods RC shear wall, steel frame, RC frame and PC wing wall for existing RC school buildings was evaluated and analysised. The analysis result indicate that the inter-story drift concentrated in the first floor and most plastic hinge forms in the column of the first story. And results of analysis of the efficiency of the seismic retrofitting indicate that inter-story drift significantly reduced and ductile behavior is expected.
        4,000원
        8.
        2000.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        중약진 지역으로 분류되고 있는 대만에서 1999년에 발생된 예상치 못한 막대한 경제적 피해와 사상자를 기록하였다. 대만과 마찬가가지로 중약진지역으로 분류되는 우리나라에서도 지진발생시 많은 문제발생이 예상됨에 따라 기존건물의 내진성능평가의 필요성의 인식하게 되었다. 본 연구에서는 미국과 일본에서 이미 적용되고 있는 기존 건축물의 내진성능 평가 기법을 분석하고 이를 3층 규모의 모멘트 골조 건물에 적용하여 평가해 보았다. 평가는 일본건축방재협회에는 철근콘크리트 구조물의 내진성능평가 규준을 적용하였다.
        4,000원
        9.
        2018.10 서비스 종료(열람 제한)
        This paper present change and expectation effectiveness after reforming raw and revising guideline about seismic performance evaluation of buildings. After reforming raw, many high-rise and large spatial structure will be included as ‘duty subjection of seismic performance evaluation’. And the guideline will change performance objectives, seismic hazard and require nonlinear dynamic analysis, structural consideration about masonry etc. After this reformation and revision, it is expected that the duty subjection of seismic performance evaluation will be extended and the raw and guideline require more high-degree specialization.
        11.
        2016.04 서비스 종료(열람 제한)
        Structural engineers needs know-how about using nonlinear analysis softwares for seismic performance evaluation of existing building. In this study, it’s compared with several softwares, nonlinear analysis are available.
        13.
        2015.04 서비스 종료(열람 제한)
        A seismic performance assessment based on risk assessment is proposed considering risk factors and scenario, and thus the technique provides more practical and reasonable seismic performance assessment and reinforcement for the existing buildings more than ever before.
        14.
        2015.04 서비스 종료(열람 제한)
        With the increase in the frequency of the seismic activity in the territory of Korean Peninsula, the demand for seismic performance evaluation of existing buildings has appeared as well. In this research, a public building built in 1970s is evaluated by the Korea Infrastructure Safety Corporation guideline. As a result, this existing public building is evaluated to satisfy the life safety (LS) and the collapse prevention(CP) performance level that the KBC2009 demands for.
        15.
        2014.04 서비스 종료(열람 제한)
        This study is to introduce a structural analysis method that can apply a unit modular system to a remodeling extension. The structural analysis process, which can reflect the behaviors between the existing building and the modular system, is performed in a five-staged structural analysis. Therefore, the example of structural analysis of an existing building is introduced.
        16.
        2014.04 서비스 종료(열람 제한)
        This paper deals with steel braced frame as increasing the lateral strength and ductility in order to seismic retrofit of existing buildings. However, There is a problem in utilizing this method. It is the approach to provide an adequate connection between the existing RC frame and the installed steel braced frame. So, the designer must be confirmed if it satisfies the required performance or not.
        18.
        2012.11 서비스 종료(열람 제한)
        This paper analyzed the CO2 emission of existing buildings with reconstruction and reusing in the declined residential area of Jeonju old town. The average CO2 emission to square meter of residential buildings in Jeonju is 1.7tCO2/m2.
        19.
        2012.11 서비스 종료(열람 제한)
        This paper analyzed the CO2 emission of existing buildings with reconstruction and reusing in declined commercial area of Jeonju old town. The average CO2 emission to square meter of commercial buildings in Junju is 1.4tCO2/m2.
        20.
        2012.11 서비스 종료(열람 제한)
        The aim of this study is to evaluate performance of snow-resistant for the existing building. For this purpose, it was to propose a way to evaluate whether facilities reach goal performance as performance level separated by immediate occupancy level and collapse prevention level. Preliminary evaluation was developed to conduct by using assessment index of five items of vulnerability and two items of impact for selecting the reinforcement priority of target facilities.
        1 2