The ductility of the system based on the capacity of each structural member constituting the seismic force-resisting system is a significant factor determining the structure’s seismic performance. This study aims to provide a procedure to supplement the current seismic design criteria to secure the system’s ductility and improve the seismic performance of the steel ordinary moment frames. For the study, a nonlinear analysis was performed on the 9- and 15-story model buildings, and the formation of collapse mechanisms and damage distribution for dynamic loads were analyzed. As a result of analyzing the nonlinear response and damage distribution of the steel ordinary moment frame, local collapse due to the concentration of structural damage was observed in the case where the influence of the higher mode was dominant. In this study, a procedure to improve the seismic performance and avoid inferior dynamic response was proposed by limiting the strength ratio of the column. The proposed procedure effectively improved the seismic performance of steel ordinary moment frames by reducing the probability of local collapse.
본 논문에서는 휨 항복 메커니즘을 기반으로 한 강재이력 댐퍼를 제안하기 위한 해석 및 실험적 연구를 수행하였다. 댐퍼는 휨모멘 트에 의한 항복거동을 하도록 설계된 일련의 댐핑 플레이트로 구성된다. 실험 결과와 유한요소해석 결과의 비교를 통해서 본 연구에 서 채택된 해석적 접근방식이 댐핑 플레이트의 형태 및 상세에 대한 민감도 연구를 수행하기에 적절함을 확인하였다. 최초에 제안된 댐퍼는 휨 항복 메커니즘을 기반으로 작동하는 것으로 고안되었으나, 댐핑 플레이트의 인장 거동에 대한 기여도가 상당할 수 있음을 관찰할 수 있었다. 댐핑 플레이트의 두께가 증가함에 따라 휨 항복에 의한 에너지 흡수량이 증가한다. 댐핑 플레이트의 두께가 감소함 에 따라 인장에 의한 댐퍼의 비선형 거동 기여도가 증가하고 좌굴 발생으로 인하여 이력곡선의 형상이 댐퍼로서 불리해진다.
본 논문에서는 중심가새골조의 내진성능 향상을 위한 전단항복 댐퍼의 개발을 수행하였다. 실용성이 높은 댐퍼의 개발을 위해서 구조적 간결성과 내진성능의 신뢰도에 중점을 둔 상세를 제시하기 위해 노력하였다. 지진 발생 시 에너지 소산 메커니즘에 대한 신뢰 도가 높고, 지진 발생 후 항복 부위의 교체가 쉬운 형태로 고안되었다. 댐퍼의 끼움강판 치수를 변경함으로써 전단, 휨-전단, 휨 메커니 즘을 조절하여 설계할 수 있다. 비선형 유한요소해석을 통해서 댐퍼의 항복 메커니즘에 따른 구조적 거동을 분석하였고, 전단항복 메 커니즘 댐퍼가 휨항복 메커니즘 댐퍼에 비해 강성, 강도, 에너지 소산 측면에서 우수한 성능을 가지고 있음을 확인하였다.
본 연구는 탄소나노튜브/보강섬유/폴리머 복합 쉘에 대한 동적응답을 다루었다. 단일벽 탄소나노튜브, 유리섬유 및 에폭시 레진으로 구성된 3단계 복합구조이며, 유효 물성값은 멀티스케일 해석을 통하여 산정하였다. 유한요소 프로그램인 ABAQUS를 적용하여 다양한 탄소나노튜브 함유비율, 적층각도, 곡률 및 중앙 개구부의 다양한 변화에 대한 동적응답 및 상호 작용을 분석하였다. 본 연구는 원통형 복합쉘의 동적 하중에 의한 처짐을 감소시킬 수 있는 변수들의 중요성을 보여주었다.
본 연구에서는 내진성능향상을 목표로 CNT-복합소재로 보강된 콘크리트 구조물의 휨 인장 거동을 다루었다. 다양한 CNT 함유량에 따른 복합소재의 재료적 물성은 수정된 Halpin-Tasi 모델을 적용하여 멀티스케일해석 이론으로부터 도출하였다. 휨인장 시험은 복합소재의 종류, CNT 함유비율, 도포제의 유무, 그리고 보강 방법에 따라서 수행하였다. 변수 실험 결과는 CNT-복합재로 보강된 콘크리트 구조의 향상된 휨인장 거동에 대하여 CNT 함유량과 적절한 도포제의 적용 (부착)의 중요성을 보여주었다.
Recent changes in the construction method of piles to minimize noise, along with the development of high-strength reinforcement, have provided an economical high performance RC pile development to compensate for the disadvantages of existing PHC piles. In this study, a methodology for the development of cross - section details of high performance RC piles of various performances is presented by freely applying high strength steel and concrete. This study suggested a technique for calculating bending moments for a given axial force corresponding to the allowable crack widths and this can be used for serviceablity check. In calculating the design shear force, the existing design equation applicable to the rectangular or the I section was modified to be applicable to the hollow circular section. In particular, in the limit state design method, the shear force is calculated in proportion to the axial force, and the procedure for calculating PV diagram is established. Last, the section details are determined through PM diagrams that they have the similar flexural and axial-flexural performances of the PHC pile A, B and C types with a diameter of 500 mm. To facilitate the application of the selected standard sections to the practical tasks, the design PM diagram and design shear forces are proposed in accordance with the strength design method and limit state design method.
기존 콘크리트 구조물에 대한 효과적인 내진보강 개발을 위하여 아라미드 FRP 보강 기둥 및 SRF 공법을 사용한 폴리에스테르 보강 RC기둥의 구조실험을 수행하였다. 실험 변수는 아라미드 시트의 두께와 스트립 보강 유무, 그리고 SRF공법 폴리에스테르 벨트의 두께이다. 실험결과는 무보강 실험체와 보강 실험체의 강도와 에너지 소산능력을 비교하여 평가하였다. 실험 결과 아라미드 섬유 보강과 SRF공법 보강이 RC기둥의 내진성능 향상에 효과적임을 확인하였다.
In this paper, we study the applicability of Tuned Mass Damper(TMD) to improve seismic performance of piping system under earthquake loading. For this purpose, a mode analysis of the target pipeline is performed, and TMD installation locations are selected as important modes with relatively large mass participation ratio in each direction. In order to design the TMD at selected positions, each corresponding mode is replaced with a SDOF damped model, and accordingly the corresponding pipeline is converted into a 2-DOF system by considering the TMD as a SDOF damped model. Then, optimal design values of the TMD, which can minimize the dynamic amplification factor of the transformed 2-DOF system, are derived through GA optimization method. The proposed TMD design values are applied to the pipeline numerical model to analyze seismic performance with and without TMD installation. As a result of numerical analyses, it is confirmed that the directional acceleration responses, the maximum normal stresses and directional reaction forces of the pipeline system are reduced, quite a lot. The results of this study are expected to be used as basic information with respect to the improvement of the seismic performance of the piping system in the future.
이 연구는 지진하중 작용시 RC 교각의 겹침이음부에서 발생할 수 있는 종방향 철근의 부착파괴를 방지하기 위한 FRP 래핑 보강공법에 관한 실험적 연구이다. FRP 래핑공법은 수작업 또는 장비를 이용해 교각에 유리섬유를 래핑하고 에폭시 수지를 이용해 고정시키는 공법이다. FRP 래핑공법의 내진성능 보강효과를 확인하기 위해, 겹침이음부가 존재하는 6개의 교각 실험체에 대해 준정적실험을 수행하였다. 실험결과 FRP 래핑공법으로 보강한 교각은 변위연성도 및 에너지소산 능력이 증가하 였으며, 무보강 실험체에 비해 연성거동함을 확인하였다. 또한, FRP 래핑 보강량과 보강효과는 선형비례하지 않으므로 최적 설 계를 통해 교각을 보강하는 것이 효과적임을 확인하였다.
Recent decades, maintenance and reconstruction have been paid attention to old buildings. Especially, it has been recognized that seismic retrofit measures are necessary for non-reinforced masonry buildings which are used for prevailing building constructions. However, such applications can be limited due to its excessive costs, long-period, and inherent difficulty in securing construction spaces. For this reason, different reinforcement methods have been proposed by previous researchers in the economic manner. This study carried out an adhesive retrofit material upgrading low workability and excessive costs of existing reinforcement methods and, in turn, verified the level of seismic reinforcement throughout experimental studies. In order for the objectives, masonry walls with an aspect ratio of 1.0 were designed and manufactured. Also, effective parameters which are affected by openings, adhesive material types, the number of reinforcement layers, and lateral load levels were established. Experimental results showed that MW specimens without openings were collapsed for low-seismic resistances resulting from rocking failure modes, while strength and displacement capacities were improved for reinforced openings. Also, R-MWO-3F specimens with opening which was enhanced for three layers of stiffener showed displacement, ductility capacities, and energy dissipating capacities in the stable manner, even satisfying the collapse prevention level proposed in the current seismic codes.
Secure operation of hospitals during and right after earthquake is essential. Past lessons from earthquake damages have shown that most of the injured and the death occurred within 30 minutes after earthquake and the portion of nonstructural damage has become significant. However, hospital buildings in Korea have not prepared fully to address such rising issues. This paper is to study what type of damage patterns are related to hospital buildings and how to develop a preparedness plan to keep hospitals operational at all earthquakes if possible. This paper first reviews on past earthquake damages reported as critical to hospital buildings while classifying them into four groups: (1) structural element; (2) architectural-nostructural element; (3) medical equipments and contents; and (4) utility facility. Upon such classification, some detailed concerns can be specified under each group explicitly. Then a hierarchy for hospital building is also developed for the classified groups, which enables us to identify required things for the enhancement of seismic performance of hospital building that consists of heterogeneous elements. To upgrade the level of seismic performance for existing hospital buildings, the concept of performance-based approach can be adopted to address the heterogeneous problems in a systematic and stepwise manner. Finally a conceptual framework for the seismic risk assessment for hospital building is proposed toward the seismic enhancement of hospital buildings using performance-based approach.
본 연구에서는 전력설비 중 그 중요도가 가장 큰 변압기를 대상으로, 지진 발생 시 변압기의 파손을 방지하기 위하여 마찰진자 면진장치를 개발하고, 진동대시험을 통하여 그에 대한 내진성능을 입증하였다. 본 연구에서 개발한 마찰진자 면진장치에 대해 압축재하시험 및 마찰시험을 수행한 결과, 변압기의 면진장치로서 적용 가능한 것으로 나타났으며, 특히 변압기 축소모형을 대상으로 진동시험대에 의한 내진성능시험을 수행한 결과, 기존의 일반 고정기초형식보다 변압기 기초부의 최대 응답가속도는 약30%, 부싱 상단의 최대 응답가속도는 약 59% 감소하였다. 또한, 마찰진자 면진장치 설치 후, 변압기의 고유진동수가 약 82% 감소하며 장주기로 이동함을 확인할 수 있었다. 이와 같이 변압기에 마찰진자 면진장치를 적용하는 경우, 지진으로 인한 변압기의 파손을 효과적으로 방지할 수 있을 것으로 판단된다.
이 연구에서는 작용하는 하중특성에 따라 적절한 감쇠력을 발휘할 수 있는 복합감쇠기(complex damper)를 제안하고 그 유용성을 장대교량의 지진응답해석을 통하여 검토하였다. 제안한 복합감쇠기는 두개 이상의 탄소성감쇠기(elasto-plastic damper)와 오일 감쇠기(oil damper)의 조합에 의하여 구성되며, 탄소성감쇠기의 변위의존적인 특성과 오일감쇠기의 속도의존적인 특성을 적절히 결합함으로서 효율적인 감쇠시스템의 구성이 가능하게 하였다. 중소형의 지진이나 작은 진폭의 진동에서는 오일감쇠기가 주로 진동을 흡수하며, 발생 빈도가 낮으나 규모가 큰 지진 등에 대해서는 탄소성 감쇠기가 진동에너지를 흡수한다. 이와 같이 복합감쇠기는 두 가지 종류의 감쇠기 역할을 잘 구분시켜 경제적이고 제진효율성이 뛰어난 설계를 가능하게 한다. 복합감쇠장치의 수학적 모델을 정립하였고, 수치모사를 통하여 응답특성과 효율성을 평가하였다. 수치모사 결과, 복합감쇠기는 단일의 수동형감쇠기를 이용하는 경우보다 뛰어난 감쇠효과를 더욱 경제적으로 구현할 수 있으며 내진성능을 크게 향상시킬 수 있는 것으로 나타났다.
본 논문에서는 기존 도로교의 합리적이고 일관적인 내진성능향상 방법 선정을 위한 가중치 평가기법을 제안하였다. 한반도의 증가하는 지진위험도를 반영하여, 현재 기존교량의 내진성능향상 작업이 다양한 공법을 이용하여 진행 중이나 최적의 공법을 선정하기 위한 적절한 판단기준이 부재한 형편이다. 이에 제안한 기존가중치 평가기법은 구조적 적합성, 경제성, 환경적 영향, 시공성, 유지관리 측면의 다섯 가지 영향인자의 가중치를 부여하여 최적의 내진 보강방안을 선정하는 방법이다. 제안된 가중치 평가기법을 공용중인 도로교 160개교에 적용한 결과 최고점수는 실제 최종 보강방안과 대부분 일치하여 적절한 가중치로 설정되었다고 판단된다. 제안하는 방법을 기존교량의 내진 보강방안 선정 시에 활용한다면, 사회적 비용을 최소화하는 보다 합리적이고 일관적인 보강이 가능할 것이다.
본 연구에서는 4층, 10층, 30층 스태거드 트러스 시스템 (STS)의 비탄성 정적해석에 의한 하중-변위 관계와 비탄성거동을 분석하고, 그 결과를 바탕으로 STS의 내진성능을 평가하였다. 또한 동일한 규모의 모멘트골조 및 가새골조의 거동과 비교함으로써 STS의 횡력 저항 능력을 파악하였다. 해석결과에 따르면, STS는 일반적으로 적용되는 구조시스템에 비하여 비교적 만족할 만한 내진성능을 보유하는 것으로 나타났다. 그러나 중층 이상의 STS에 있어서는 상대적으로 강성이 작은 비렌딜 패널 상.하현재에 소성변형이 발생한 후 인접한 수직 가새가 항복함으로써, 다른 층으로 소성변형이 전이되지 못하여 약층의 형성에 의한 취성적인 거동을 보인다. 그러므로 스태거드 트러스 시스템의 연성능력을 확보하기 위해서는 비렌딜 패널의 수직 가새를 보강하여 비렌딜 패널 상하현재에 발생한 소성변형을 다른 층의 비렌틸 패널로 유도하는 것이 필요하다.