        This paper investigates seismic performance of a small-sized single story building in Korea. Nonlinear pushover anlaysis is performed to verify shear failure of RC short columns eventually led to performance degradation. Also, nonlinear time history analysis is performed using the same earthquakes from Gyeongju. Similar failure mode was obtained as in the report where a sudden rupture of the RC columns happened.
        4,000원
        2.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Piloti-type building is one of typical vertical atypical buildings. These buildings can fail by weak-story or flexible-story mechanism on the first story. They should be designed by taking into account the special seismic load, but those less than six stories are not required to confirm the seismic performance from structural engineers in Korea. For this reason, small-size pilloti-type RC buildings need to be checked for seismic performance. Based on this background, this study performed nonlinear dynamic analysis using the PERFORM-3D for small-size pilloti-type RC buildings and assessed their seismic performance. Examples are two through four story buildings with and without walls in the first story. The walls and columns in the first story satisfied the target performance in the basic of flexural behavior due to quite a large size and reinforcement. However, wall shear demands exceed shear strength in some buildings. When designed for KBC2009, wall shear strength exceed shear demand in some buildings, but still does not in others. Consequently, wall shear must be carefully checked in both existing and new small-size pilloti-type RC buildings.
        4,000원
        3.
        2016.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Small-size buildings are not designed by professional structural engineers in Korea. Therefore, their seismic performance can not be exactly estimated because their member sizes and reinforcement may be over- or under-designed. A prescriptive design criteria for the small-size buildings exists, but it also provides over-designed structural members since structural analysis is not incorporated, so it is necessary to revise the prescriptive criteria. The goal of this study was to provide an information for the revision, which is seismic performance and capability of small-size reinforced concrete moment frame buildings. For the study, the state of existing small-size reinforce-concrete buildings such as member size and reinforcement was identified by investigating their structural drawings. Then, over-strength, ductility and response modification factor of the small-size reinforced concrete moment frame buildings were estimated by analytical approach along with seismic performance check. The result showed that they possess moderate over-strength and ductility, and may use slightly increased response modification factor.
        4,000원
        4.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For small-size reinforce-concrete buildings, Midas Gen, OpenSees, and Perform-3D, which are structural analysis programs that are most popularly used at present, were applied for nonlinear static pushover analysis, and then difference between those programs was analyzed. Example buildings were limited to 2-story frames with irregular shaped walls. Analysis result showed that there were more differences than for frames only and frames with rectangular walls, but it was not so significant. Nevertheless, the capacity curve were different in some buildings, which is attributed to shape and location of walls, and feature of the analysis program. Especially, selection of automatic or manual input in Midas Gen, or nonlinear wall elements in Perform3D can affect the capacity curve and performance of the buildings. Therefore, the program users should understand the feature of the program well, and then conduct performance assessment. The result of this study is limited to low-story buildings so that it should be noted that it is possible to get different results for mid- to high-rise buildings.
        4,000원
        5.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For small-size reinforce-concrete buildings, Midas Gen, OpenSees, and Perform-3D, which are structural analysis programs that are most popularly used at present, were applied for nonlinear static pushover analysis, and then difference between those programs was analyzed. Example buildings were limited to 2-story frames only and frames with one or more rectangular walls. Analysis results showed that there was not much difference for frames only based on capacity curves. There were some differences for frames with rectangular walls, but it was not so significant. The global behaviors represented by the capacity curve were not so different, but the feature of each analysis program appeared when the results were analyzed in more detail. Therefore, the program users should understand the feature of the program well, and then conduct performance assessment. The result of this study is limited to low-story frames only and frames with rectangular walls so that it should be noted that it is possible to get different results for frames with non-rectangular walls or mid- to high-rise buildings.
        4,000원
        6.
        2014.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Since the execution of structural design by professional structural engineers is not mandatory for small-size buildings in Korea, structural design is conducted by architects or contractors resulting in concern about the seismic safety of the buildings. Therefore, the Korean Structural Engineers Association proposed dedicated structural design criteria in 2012. The criteria were developed based on a deterministic approach in which the structural members are designed only with information of story and span length of the buildings and without structural analyses. However, due to the short time devoted to their development, these criteria miss satisfactory basis and do not deal with structural walls popularly used in Korea. Accordingly, the Ministry of Land, Infrastructure and Transport launched a research on the 'development of structural performance enhancement technologies for small-size buildings against earthquakes and climate changes'.. As part of this research, this paper intends to establish direction for the preparation of deterministic structural design guidelines for seismic safety of domestic small-size reinforced concrete buildings. To that goal, a typical plan of these buildings is selected considering frames only and frames plus walls, and then design is conducted by changing the number of stories and span length. Next, the seismic performance is analyzed by nonlinear static pushover analysis. The results show that the structural design guidelines should be developed by classifying frames only and frames plus walls. The size and reinforcement of structural elements should be provided in the middle level of the current Korean Building Code and criteria for small buildings by considering story and span length for buildings with frames only, and determined by considering the shape and location of walls and the story and span length as well for buildings with frames plus walls. It is recommended that the design of walls should be conducted by reducing the amount of walls along with symmetrically located walls.
        4,000원
        7.
        2012.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        우리나라의 건축법 시행령에서는 3층 미만 그리고 연면적 1000m2미만의 건축물을 소규모 건축물로 정의하고 있으며 내진설계 적용 대상 범위에서 제외하고 있다. 하지만 소규모 건축물에 거주하는 인구의 비율이 상당하다는 사실을 고려할 때, 소규모 건축물의내진성능을 확보하는 것은 지진 재해 경감에 있어서 중요한 부분이라고 할 수 있다. 이 논문에서는 2층 철골 건물에 비좌굴 Knee가새를적용한 예제 연구를 통해서 소규모 건물의 내진보강 전략에 대한 연구를 수행하였다. 확률론적 내진성능 목표를 바탕으로 가새의 상세를결정하였고, 이를 위해서 다양한 구조적 특성에 대한 취약성 분석 결과를 즉시 구해서 비교할 수 있는 취약성 등고선을 이용하였다. 기존에수행된 실험적, 해석적 연구결과를 바탕으로 75개의 BRKB모델을 개발하였으며, 이 중에서 예제 건축물에 대한 BRKB의 가장 효과적인보강 방안은 취약성 곡선을 이용한 내진성능의 검증과 강재의 무게를 바탕으로 결정하였다. 본 연구를 통해서 취약성 등고선을 이용한내진성능평가 방법이 확률론적 내진성능목표를 바탕으로 한 보강전략수립에 효율적으로 사용될 수 있는 것으로 나타났다.
        4,600원
        8.
        2003.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Considering the established research about the characteristics of traditional expression in a contemporary korean architecture, there are two critical problems. the one is that the extent of a case is limited to a public building and a large exhibition building. the other is that the angle of research focus on the viewpoint of specific a level. To settle these problems and supplement a established research, this study is to investigate and analyze the characteristics of popular traditional expression in small commercial buildings. In A viewpoint on the expansion of a case and a various angle, A small commercial buildings is selected as a case. because it is felt that the populace's taste vis-a-vis traditional expression. To investigate and analyze, A main analytic criterion is follows. 1) A expressional method on traditional architectural form 2) A expressional aspect by architectural element 3) A expressional aspect in architectural material 4) A expressional aspect in architectural structure. In consequence we can find out the following results in the process of analysis. 1) In expressional method on traditional architectural form, the traditional expression is represented as the imitation and transformation of a traditional folk house forms, and the embodiment of traditional image 2) In expressional aspect by architectural element, the traditional expression elements is mainly represented at a straw roof and a mud-plastered wall 3) the traditional expression material is mainly straw, timber, small wood boards and mud 4) In expressional aspect in architectural structure, the traditional expression is represented from the viewpoint of decorative expression.
        5,100원
        9.
        2019.10 서비스 종료(열람 제한)
        소규모 취약시설 안전점검은 그동안 안전취약계층이 사용하는 건축물의 안전 및 유지관리를 위하여 지속적으로 확대되어 왔으며, 한정된 자원조건에서 특정다수를 대상으로 하는 시설물의 효율적인 안전점검을 실시하기 위하여 다양한 대응전략이 요구된다. 대부분의 안전점검 업무특성 중 하나는 해당범위 시설물에 대한 신속 정확한 관리를 위해서는 직접적인 안전점검 수행 이 외 우선순위선정, 선택과 집중의 상황판단이 동반된다. 이에 본 연구에서는 대상범위가 넓은 소규모 취약시설 안전 점검을 수행하면서 축척된 결과데이터 현황을 분석하고 이에 따라서 실시되고 있는 주요 대응전략을 도출하고자 한다.
        10.
        2019.09 KCI 등재 서비스 종료(열람 제한)
        소규모 철골조건축물의 접합상세에 대한 현장조사에 따르면 지진하중에 의한 횡적 안전성 및 안정성 확보가 불충분할 것으로 예상되는 임의 접합상세가 현장에서 적용되는 것으로 조사되었다. 이에 따라 본 연구에서는 소규모 강구조건축물의 노출형 주각부 약축 연결부의 반복이력 실험을 통해 문제점을 분석하고, 이를 바탕으로 내진성능을 향상시킬 수 있는 접합상세의 개발을 위해 일련의 실험연구를 수행하였다. 본 실험결과에 의하면, 국내에서 흔히 사용되는 노출형 주각부 약축방향 접합부의 이력거동은 앵커볼트가 콘크리트로부터 점진적으로 인발됨에 따라 베이스플레이트와 앵커볼트사이에 이격거리가 누적되어 하중역전구간에서 “Rocking” 현상이 발생되어 내진성능이 매우 낮은 것으로 조사되었다. 이와 같은 문제점을 개선하기 위하하여 앵커볼트의 콘크리트에 대한 부착 유/무와 개수 및 배열형태 등을 변수로 한 성능 개선 실험체에 대한 일련의 반복 이력 실험을 수행하였으며, 최종적으로 소규모철골조 건축물의 노출형 주각부에 고강도 전산볼트형 앵커볼트를 8개로 3열로 배치하는 상세의 적용을 통하여 하중지지능력과 에너지분산능력 측면에서 내진성능이 크게 개선된 것을 확인할 수 있었다.
        11.
        2019.04 서비스 종료(열람 제한)
        In this study, an effective maintenance and management strategies were discussed to secure a structural safety of small-scaled timeworn buildings in Seoul. The structural vulnerable characteristics should be analyzed to fix the order of priority on maintenance and management of lots of buildings. This study could be used for a policy establishment of Seoul.
        12.
        2016.04 서비스 종료(열람 제한)
        In Korea, Small-size buildings are not performed structural calculation. Also it does not assess the safety about lateral loads such like earthquake. In this study, We proposed the steel column bases that can be applied to small buildings. And We analyzed the Steel Column Bases flexural behavior.
        13.
        2016.04 서비스 종료(열람 제한)
        This study compares the steel column-base plate connections to improve the flexural capacity of small building. In addition, performance level was evaluated by example building. Analysis results, an additional reinforcement is required to the proposed steel column-base plate connection. And then, We should compared the impact of beam-column joints.
        14.
        2015.04 서비스 종료(열람 제한)
        It is required development on the work process of the legal system, quality and safety management for safety securement of small sized buildings. Therefore, this is suggested the improvement on the quality and safety management for safety securement of small sized buildings.
        15.
        2014.10 서비스 종료(열람 제한)
        In this study, based on the Building Register, status and existing structural criteria of small-scale steel-frame building is reviewed. As a result, the accumulated small-scale buildings account for about 85% of cumulative entire building. Furthermore, since 2000, the small-scale steel-frame buildings account for about 55% of the small-scale buildings. In other words, the proportion of small-scale steel-frame buildings has been increased. However, the structural criteria is not only insufficient but also structure for some small-scale steel-frame buildings does not have a reference.
        16.
        2014.04 서비스 종료(열람 제한)
        This paper is the result of analysing the Building Register. It describes the ebb and flow about small-scale buildings for 5years. Major cities are rapidly decreasing small-scale buildings. On the other hands, Small and medium-sized cities are monotonic. Currently, All of the Korea buildings are occupied by small-scale buildings up to 82%. So, This researcher suggest that these buildings need to standardized design of structure for preparing earthquake and abnormal climate.