        PURPOSES : In this study, energy-consuming processes in asphalt plants were evaluated, and the drying and mixing processes were characterized using a thermal equilibrium equation-based model to quantitatively estimate the amount of energy consumed during the production of mixtures in asphalt concrete plants. METHODS : An energy consumption model based on the thermal equilibrium equation was used to estimate the energy consumption of the aggregate drying process that consumes the maximum energy; the energy consumed for material transportation, storage, and operation of other facilities was cited from the literature. The results were compared with the actual results obtained for recycled hot asphalt mixtures and recycled warm mix asphalt mixtures, and a sensitivity analysis was performed by varying the conditions. RESULTS : An analysis of the main processes required to produce asphalt mixtures showed that the water content had the largest impact on energy consumption (approximately 80%). This quantitatively supports the opinion of field practitioners that maximum energy is consumed during aggregate drying. Although some discrepancies were observed, the results were found to be reasonable and within the range of typical measurements. CONCLUSIONS : The thermal energy consumption estimation model provides consistent results that reflect the characteristics of the mixture and can be used to derive the thermal energy consumption rates for individual materials, such as aggregates and binders. This can be used to identify the priorities for process optimization within a plant.
        4,000원
        4.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기후변화로 인해 가속화되고 있는 충남 지역 가뭄현상에 대응하고 대산 임해산업단지의 증가하는 용수 수요를 만족하기 위해서, K-water에서는 100,000 m3/일 규모 역삼투 해수담수플랜트 건설 사업을 추진하고 있다. 이에 본 연구에서는 해수담수플랜트 운영비용의 70% 이상을 담당하는 역삼투 공정 성능에 영향을 미치는 주요 인자에 대한 성능 분석을 수행하였다. 대산 지역 해수 염분농도 및 수온 변화 조건에서 RO 공정의 전력소모는 2.39 ± 0.13 kWh/m3로 나타났으며, 막여과유속과 회수율이 낮을수록 전력소모가 절감되어 연간 운영비용이 감소하였다. 주요 막 제조사별 고유량 막의 성능 비교 결과, 전량 2단 여과공정(full two pass) 기준 생산수 TDS는 평균 3.84 mg/L로 양호하였고, 전력소모는 2.22 ± 0.13 kWh/m3 수준으로 확인되었다. 역삼투 공정 구성을 전량 2단 여과방식에서 partial 또는 split partial 방식으로 변경함에 따라 전력소모는 최대 0.29 kWh/m3, 막모듈 설치비용은 최대 15.6% 절감 가능할 것으로 기대된다.
        4,000원
        5.
        2018.11 구독 인증기관·개인회원 무료
        본 연구는 역삼투 해수담수화 플랜트의 실 데이터 분석을 통해 에너지 소모를 줄이는 방안을 제안한다. 이를 위해 10,000m3/d 이상의 플랜트를 대상으로 70여개의 데이터를 수집하고 분석하였다. 역삼투 해수담수화 플랜트의 에너지 소모는 에너지회수장치 발전으로 인해 크게 감소하였으나 각 요인에 따라 다른 값을 보였다. 에너지 소모는 유입수 수질에 영향을 받고, 높은 수질의 생산수를 얻기 위해선 더 많은 에너지가 소모됨을 확인하였다. 또한, 플랜트 규모가 커지면 에너지 소모가 줄어든다고 알려져 있으나 반드시 그런 것은 아니며, 역삼투시스템 운영 시 에너지 소모가 최소가 되는 회수율이 있음을 알아냈다. 마지막으로 에너지 소모와 관련된 요인을 정리하고 이를 바탕으로 저에너지 소모를 위한 3가지 방안을 제시한다.
        6.
        2018.05 구독 인증기관·개인회원 무료
        In this study, we utilize the cross and partial correlation analyses in order to investigate the dependence of power energy consumption on the temperature. To this end, we use a time series data that consists of three attributes : an hourly measured electric power consumption, temperature, and humidity. We, in particular, divide the yearly data into monthly base, and estimate the cross correlation coefficients between all possible pairs of attributes for each monthly based data. We found that temperature and power consumption are negatively correlated in the winter; positively correlated in the summer. A similar trend was found between humid and power consumption. This implies that when temperature or humidity is relatively high or low, the power consumption increases due to the cooling and heating system at work. In contrast, the correlation between temperature and humid behaves differently from those between temperature and power consumption. These results can be used to effectively manage the power system.
        7.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Gas hydrate desalination process is based on a liquid to solid (Gas Hydrate, GH) phase change followed by a physical process to separate the GH from the remaining salty water. The GH based desalination process show 60.5-90% of salt rejection, post treatment like reverse osmosis (RO) process is needed to finally meet the product water quality. In this study, the energy consumption of the GH and RO hybrid system was investigated. The energy consumption of the GH process is based on the cooling and heating of seawater and the heat of GH formation reaction while RO energy consumption is calculated using the product of pressure and flow rate of high pressure pumps used in the process. The relation between minimum energy consumption of RO process and RO recovery depending on GH salt rejection, and (2) energy consumption of electric based GH process can be calculated from the simulation. As a result, energy consumption of GH-RO hybrid system and conventional seawater RO process (with/without enregy recovery device) is compared. Since the energy consumption of GH process is too high, other solution used seawater heat and heat exchanger instead of electric energy is suggested.
        4,200원
        8.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 숲길 이용자들이 폭발적으로 증가하고 있으며, 이에 따라 각종 안전장치를 위한 비용 또한 급격히 증가하고 있다. 그럼에도 다른 사고와 달리 심장관련 사고는 줄지 않고 있어 숲길에 제공되는 난이도 정보의 개선방안에 대한 연구를 지리산 둘레길을 대상으로 진행하였다. 기존 숲길에 대한 난이도 정보는 숲을 관리하는 특정인에 의한 경험적 난이도 또는 단순히 거리를 바탕으로 한 난이도를 3~5단계로 구분하여 제공하고 있어 탐방객이 실제 느끼는 난이도와는 괴리감이 있었다. 본 연구에서는 실질적인 에너지소모량을 바탕으로 한 난이도 제공 가능성을 분석하였다. 거리와 경사에 따른 산소소모량의 계산은 숲길 각 구간에 대한 절대적 비교뿐만 아니라 상대적 비교가 가능하였으며 특정 구간의 운동강도를 간단히 표현하는데 효과적이었다. 아울러 시·종점의 변화에 따른 운동량 변화를 쉽게 확인할 수 있었다. 구간별, 산행방향별 운동량에 대한 표준화된 사전 정보제공은 심장관련 사고의 사전예방 효과가 있을 것으로 판단된다.
        4,000원
        9.
        2015.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The authors set out to estimate the related carbon emissions, energy use, and costs of the national freeways and highways in Korea. To achieve this goal, a macro-level methodology for estimating those amounts by road type, road structure type, and road life cycle was developed. METHODS : The carbon emissions, energy use, and costs associated with roads vary according to the road type, road structure type, and road life cycle. Therefore, in this study, the road type, road structure type, and road life cycle were classified into two or three categories based on criteria determined by the authors. The unit amounts of carbon emissions and energy use per unit road length by classification were estimated using data gathered from actual road samples. The unit amounts of cost per unit road length by classification were acquired from the standard cost values provided in the 2013 road business manual. The total carbon emissions, energy use, and cost of the national freeways and highways were calculated by multiplying the road length by the corresponding unit amounts. RESULTS: The total carbon emissions, energy use, and costs associated with the national freeways and highways in Korea were estimated by applying the estimated unit amounts and the developed method. CONCLUSIONS: The developed method can be employed in the road planning and design stage when decision makers need to consider the impact of road construction from an environmental and economic point of view.
        4,000원
        10.
        2006.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The walker provides stability for walking for people whose lower extremities are disabled. It is important to measure and determine the appropriate height of a walker to conserve energy and to improve function. The purposes of this study were to examine effects of walker height and gait velocity on triceps, latissimus dorsi muscle activation, and energy expenditure index (EEI) during ambulation with a walker. Fifteen healthy subjects participated in this study. Each subject was assigned a walker with one of three heights (high, standard, lower height) and of two gait velocities (comfortable gait velocity or fast gait velocity). Electromyographic data were collected from triceps and latissimus dorsi, and EEI was determined from each condition. Two-way repeated analysis of variance (ANOVA) was used to determine the statistical significance. Post hoc comparison was performed with the Bonferroni test. The results of this study were summarized as follows: 1. There was a significant difference in the %MVIC of triceps among different walker height factors. Post hoc comparison revealed that %MVIC of dominant triceps brachii was more significantly increased in patients who used the higher walker than those who used the lower walker (p<.05). 2. There were significant differences in the %MVIC of the latissimus dorsi among different walker height factors and gait velocity factors. Post hoc comparison revealed that the %MVIC of dominant latissimus dorsi was also more significantly increased in patients who used the higher walker than those who used the lower walker (p<.05) and in those who used the faster gait velocity than those who used the slower gait velocity (p<.05). 3. There were significant differences in the EEI among different walker height factors and gait velocity factors. Post hoc comparison revealed that the EEI was significantly increased among those who used higher and lower walkers compared with the standard walker. The EEI was also more significantly increased among those who used the fast gait velocity than those who used the slower gait velocity (p<.05). It has been concluded that increased muscle activation in triceps and latissimus dorsi was required when the walker height increased and that more energy was exp ended when the gait velocity increased. Therefore, from the findings of this study, it is recommended that walker height be adjusted according to the purposes of gait training and that healthy subjects conserve energy when ambulating with standard walkers in a comfortable gait velocity.
        4,000원
        11.
        1999.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Going up and down the stairs is a repeated task in the activities of daily living. These activities are needed during the recovery process with impaired lower limbs. This paper presents the difference of EEI (energy expenditure index) through the slope of stairs. Twenty-one normal young adults took a part in this study (11 males, 10 females). They stepped up and down the stairs which had two different slopes for 5 minutes. Resting heart rate, walking heart rate, and moving distance were recorded. EEI was calculated from the heart rate and moving speed which was calculated by the distance of movement. Data were analyzed by repeated two-way ANOVA with SAS program and the difference of EEI through the slope of stairs was not statistically significant (p=0.9971). The results show that EEI was not affected by the slope of stairs in normal people. But distance of movement (p=0.0067) and speed (p=0.0064) had a significant difference.
        4,000원
        13.
        2014.04 KCI 등재 서비스 종료(열람 제한)
        This paper examined energy consumption distribution by process and energy production-effect of MBT facilities inKorea. Generally, facilities that use fossil fuels for drying consumed energy about 70~80% in drying and exhaust gasestreatment process and energy distribution was heavily affected a position of drying and a kind of fuel. Energy production-effect by the ratio of input-energy to output-energy ranged from 4.54 to 9.60, however, if generation efficiency is reflected,it was standardized to low levels from 3.10~3.77. So we were able to confirm that the superiority of energy production-effect between facilities is not considerable.
        14.
        2013.06 KCI 등재 서비스 종료(열람 제한)
        우리나라는 태권도의 종주국임에도 불구하고 신체활동량과 그에 따른 에너지 소모량에 대한 기초연구가 미흡하며 이에 대한 연구가 시급한 상태이다. 본 연구에서는 센서(SenseWear® PRO2 Armband)를 이용하여 태권도의 신체활동 량을 획득하였고, Inbody 520을 통하여 체성분 데이터를 획득 하였으며, CT로 하체부위(허벅지)를 스캔하여 허벅지 근육면적 데이터를 추출하였다. 획득된 데이터를 이용하여 허벅지 둘레와 근육면적의 상관관계, 허벅지 근육면적과 분 당 에너지 소모량의 상관관계를 분석하였다. 분석결과 실험자 8명의 평균 허벅지 근육면적은 132.79 cm2 였으며, 무 릎뼈(Pattela) 위 20 cm의 평균 허벅지 전체 면적은 178.79 cm2이었다. 실험자들의 허벅지 둘레와 근육면적은 상관 관계가 있는 것으로 나타났다. 실험자들의 평균 분당 에너지 소모량은 6.94 칼로리였으며, 허벅지 근육면적과 평균 분 당 에너지 소모량도 상관관계가 있는 것으로 나타났다.
        15.
        2010.12 KCI 등재 서비스 종료(열람 제한)
        고 고형분함량 감자 생산을 위한 수확시기를 예측하는 데 있어 에너지 소모량의 추정에 대한 연구결과는 다음과 같다. 1. 각 지역별로 포장의 파종시기부터 수확시기까지 최근 5년간(2005년~2009년) 평균기온, 강수량, 상대습도, 일조시간, 바람, 지중온도 등의 농업환경을 조사한 결과 파종기 저온피해와 괴경비대기 장마기간을 회피한다면 가공용 원료감자는 가공품 생산에 필요시마다 물량을 수급하기 때문에 만숙재배를 하지 않아 품종의존도가 낮아 수확시기의 환경에 대한 비중이 큰 것으로 판단되었다. 2. 파종시기부터 출현까지에는 지중온도에 영향을 많이 받아 지역별 편차가 심해 시뮬레이션에서는 출현시기를 기준으로 감자의 수확적기를 예측하는 것이 바람직하였다. 3 수확시기를 예측하기 위한 생장모형은 Tp=Tm~cdotWmTpWmTm를 사용하고, 생장량 Wm을 계상하는 기본 생장모형은 Wm=~intmtf(x)dt 를 사용하였다. 4. 기본 생장모형을 통해 Wm을 계상할 때는 광합성율(δA )과 식물체내 에너지 소모(δE ) 개념을 적용해야 보다 정밀한 수확시기를 예측할 수 있었으며, 식물체내 에너지 소모에 대한 정의는 기후변화에 대응하여 농업환경에 대처하는 식물체내 에너지 소모를 계상하는 것으로 최근 5년간(2005년~2009년) 수확시기에 따라 고형분함량을 측정한 결과 광합성율만 계상할 때 보다 에너지 소모개념을 적용한 것이 효과적이었다.