검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 15

        1.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, optical infrared thermography simulation using thermal wave imaging technique is performed to analyze the thermal characteristics of delamination defects. In this study, lock-in thermography(LIT) and pulsed thermography(PT) simulation was performed to analyze the samples of european traditional tiles with delamination defects, and the analytical modeler was developed through the ANSYS 19.2 transient thermal analysis tool. Applied sinusoidal heating with modulation frequency according to pulse heating and phase locking technique. The thermal response of the sample surface by heating was recorded and then data analysis was performed. The temperature gradient characteristics of each technique were compared, and phase angle was calculated for the LIT to analyze the parameters for the experiment setting. The simulation model was developed as a useful data for practical optical infrared thermography tests.
        4,000원
        2.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Thermographic imaging based non-destructive evaluation proceeds measuring the defect or internal condition of civil structures. To demonstrate the feasibility of the method, the infrared camera system is applied to various specimens. The technique described in this paper may allow us to find their numbers, locations, and the extent of damaged steels from the measurement in the long distance. In addition, a reinforced concrete specimens with different penetration depths is tested using the active thermography method, and to study the influence on the detecting internal rebar in cooled and heated conditions. The experimental results demonstrate that thermographic imaging method is useful for detecting the damage of steel structures and the unknown rebar in the concrete.
        4,000원
        3.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        IR camera has been used widely for the temperature measurement and fault detection of the moving bodies and rotating bodies. The high-speed performance of the IR camera and a reliable thermal analysis method are required for the condition monitoring of the railway vehicle running at high speed. The effective fault detection method using a thermal image analysis could make a real time monitoring of the high speed train possible. Therefore the investigation of the performance of the thermal image analysis method was performed to find the effective thermal image data analysis method. The results suggested that the comparison of the characteristics of the temperatures obtained at different conditions and a continuous temperature subtraction method could be used as a useful analysis method for detecting abnormal temperature condition and histogram equalization could also help to enhance the fault detectability by increasing the contrast of the thermal image
        4,000원
        4.
        2006.09 구독 인증기관 무료, 개인회원 유료
        In recently, the method estimated construction's defeat using the infrared thermography was prefer to method of new repair and estimate as a good point that simple of application and save labor, what is more economic than other techniques and can reduce need time. The purpose of this study is to develope the technique to measure the corrosion of reinforcing bars using the infrared thermal photography graphic data. In this page, the former final purpose establishment that galvanic corrosion method of reinforced bars and infrared thermography system, and studied trend of thermography and photography graphic data by parameters of corrosion of specimens, atmosphere temperature, concrete cover depth etc.
        4,000원
        5.
        2018.04 서비스 종료(열람 제한)
        Recently, accidents caused by the aging of structures are occurring frequently in the world. As a result, maintenance and accident prevention of structures are required. In this study, for the purpose of addressing these issues to solve these problems, we developed a non - destructive inspection technique using thermal imaging and planned damage detection process. we set up a scenario to detect the invisible excursions, cracks, and internal damage by sensing and analyzing the thermal energy radiated by the stainless steel test piece (STS304) with infrared thermal imaging equipment.
        6.
        2017.09 서비스 종료(열람 제한)
        The purpose of this research is to consider the qualitative and quantitative performance of reinforced concrete deteriorations using active infrared thermography (IRT) technique. An experiment of five different cases of environmental conditions was conducted on a concrete slab in laboratory. A comparison of the IRT results between normal and reinforced concrete is also discussed. The results showed that the absolute contrast between defective area and non-defective area increases with the increment of ambient temperature. Besides, the values of absolute contrast above delamination obtained from normal concrete showed high than those under effect of reinforcing steel bar.
        7.
        2017.05 서비스 종료(열람 제한)
        현재 정부에서는 폐자원 에너지의 회수・사용을 촉진하기 위해 정책적인 움직임을 보이고 있다. 폐기물 소각시설의 소각열에너지 회수・사용률 산정방법이 2015년에 확정되었고, 이를 반영한 자원순환기본법이 2018년 1월 1일부터 시행될 계획이다. 이에 따라, 국내 폐기물 소각시설의 에너지 회수・사용률을 증가시키기 위해 열에너지 회수를 통한 전기나 열원 생산의 효율을 측정하고 평가하는 것이 필요하다. 폐기물 소각시설 공정에서의 방열손실은 열에너지 회수의 효율을 저하시키는 원인 중 한가지이다. 이를 평가하기 위하여 소각시설의 벽면온도를 측정하여야 하며, 현재의 소각시설 벽면 온도 측정 방법은 환경부 고시 ‘폐기물 처리시설의 세부검사방법에 관한 규정’의 별표1 ‘폐기물 소각시설의 세부 검사방법’에 따른 지점측정 방식이다. 하지만 지점측정 방식의 온도 측정은 접촉식 온도계를 이용한 측정법으로, 대상의 접촉 지점에 따라 온도가 다르게 측정될 수 있으며 대상 시설의 평균 표면온도를 정확하게 측정하는 것에 한계를 가진다. 적외선 열화상 카메라는 대상의 넓은 면적을 동시에 촬영하여 온도를 측정하는 방식으로, 시설의 평균 표면온도를 비교적 정확하게 측정할 수 있다. 따라서 본 연구에서는 실제 가동 중인 폐기물 소각시설의 벽면 온도를 비접촉 온도 측정 방식의 적외선 열화상 카메라를 이용하여 측정하고, 기존에 수행되었던 연구를 통해 정립된 방열손실 산정식을 이용하여 방열손실을 계산하였다. 또한 폐기물의 소각 온도, 소각 용량, 소각로 표면적 크기 등 여러 가지 요인에 의한 방열손실을 고려하기 위하여 소각시설의 입열과 출열 항목을 측정하여 투입된 에너지 대비 손실량인 방열손실률을 산정하여 평가하였다.
        8.
        2017.04 서비스 종료(열람 제한)
        The Infrared-Thermography Technique is widely used for nondestructive evaluation (NDE) of structures due to its convenience. Particularly, various techniques have been tried to detect imperfections such as surface defects and welding defects of steel structures. This paper is a part of a study to detect defects in weld zone in steel structures using Infrared Thermography techniques. Finally, defects were detected by comparing infrared thermal image and surface temperature data of defected area with healthy area.
        9.
        2017.03 KCI 등재 서비스 종료(열람 제한)
        Recently, domestic waste policy has focused on resource circulation. In accordance with Article 3, Paragraph 2 of the “Enforcement Rules of Wastes Control Act”, which is targeted at waste incineration facilities, we established and announced methods for calculating the recovery and utilization rates of incineration-sourced heat in 2015. The lower heating value is important to energy recovery and utilization rate calculations. Hence, the lower heating values of the waste incineration facilities were estimated using the thermal method from KS B 6205. Heat loss decreases the heat recovery efficiency, and should be measured and evaluated. The surface temperatures of the incinerator and boiler are required to determine heat loss. Presently, the contact point temperature method is used to measure the surface temperature. It is difficult to apply this method to the average surface temperature of an incineration facility. In this study, 20 Korean waste incineration facilities were selected for heat loss estimates based on waste incineration temperature, incinerator type, and incineration capacity. Infrared thermal cameras were used to measure the surface temperatures of the waste incineration facilities.
        10.
        2016.11 서비스 종료(열람 제한)
        ‘전국 폐기물 발생 및 처리현황’(환경부, 2014)에 따르면, 국내의 전국 폐기물 총 발생량은 매년 증가하는 추세이다. 건설 폐기물을 포함한 ‘14년도 총 폐기물 발생량은 388,486톤/일에 달하며, 지정폐기물을 포함하면 폐기물 발생량은 더 증가한다. 이렇게 발생한 폐기물은 매립, 소각, 재활용, 해역배출로 처리되었다. 하지만 국내의 육상 폐기물 해역배출은 런던협약에 ‘16년부터는 전면 금지되었으며, 매립과 재활용을 통한 폐기물의 처리는 한계가 있다. 지속적으로 발생량이 증가하는 폐기물의 처리와 지정폐기물, 재활용 금지 및 제한대상 폐기물을 처리하기 위하여 폐기물의 소각처리가 필수적으로 요구된다. 국내에서는 정책적으로 폐기물 소각시설의 폐자원에너지 회수와 사용에 대해 집중하고 있으며, 2015년에 폐기물 소각시설의 소각열에너지 회수・사용률 산정방법을 확정하여 2018년 1월 1일부터 자원순환기본법을 통해 시행할 것을 예고하였다. 사업장폐기물 소각시설의 소각열에너지 회수・사용률 산정방법에 따르면 열정산법을 이용해 입열과 출열을 산출하여 소각시설의 효율을 계산한다. 소각로의 방열손실은 에너지의 회수 효율을 낮추는 출열 항목 중 한가지로 각 시설마다 측정하여 평가되어야 한다. 현재 방열손실 평가를 위한 소각로의 벽면 온도 측정은 지점측정법을 이용하여 실측되고 있다. 하지만 접촉식 온도 측정은 대상의 접촉 지점마다 온도가 다르게 측정 될 수 있으므로 대상 시설의 평균 표면온도를 정확하게 측정하는 것이 어렵다. 비접촉 방식으로 온도를 측정하는 적외선 열화상 카메라는 넓은 면적의 온도를 동시에 측정 가능하며 대상 시설의 평균 온도를 비교적 정확하게 측정 할 수 있다. 따라서 본 연구에서는 폐기물 소각시설의 출열 항목 중 방열손실의 측정 및 평가를 위해 적외선 열화상 카메라를 이용하였으며, 소각로 표면 온도 측정방법과 소각시설의 방열손실 산정 방법을 정립하였다.
        11.
        2015.11 서비스 종료(열람 제한)
        적외선 열화상 카메라는 피사체의 실물을 보여주는 것이 아닌 피사체의 표면으로부터 복사(방사)되는 전자파의 일종인 적외선 파장 형태의 에너지(열)을 검출, 피사체 표면 복사열의 강도를 측정하여 강도의 양에 따라 각각의 다른 색상(false or pseudo color)으로 표현하여 주는 카메라이다. 이는 대상물체 또는 임의의 범위에 존재하는 열의 차이(온도)를 비접촉 방식으로 측정이 가능하다. 현재 방열손실의 온도 측정은 KS법에 의한 지점별 온도측정을 하고 있으나, 이는 접촉하는 지점마다 온도가 달라 평균적인 온도를 구하는 데는 문제점이 있다. 이를 개선하기 위해 공정별 표면온도를 고분해능 검지기를 이용한 적외선열화상카메라로 방열손실률을 측정 분석하고자 한다. 본 연구에서는 적외선 열화상 카메라 Laser Marker(-60℃ ~ 760℃)를 이용하여 Laser의 표면온도를 측정할 수 있는 미국제조회사인 FLIR社의 T650sc 모델을 이용하여 사업장 폐기물 소각시설의 소각로의 벽면의 온도를 측정하였다. 측정된 온도를 이용하여 복사 열 전달률을 구하기 위한 Stefan-Boltzmann법칙과 대류 열 전달율을 구하기 위한 Newton의 냉각 법칙과 소각로의 면적을 이용하여 로벽의 방열되는 손실을 계산해 보고자한다. 국내의 사업장 폐기물 소각시설 78개 호기 중 소각 방법별(일반소각, 고온소각), 소각로 타입별(Stoker, R/K + Stoker, R/K)로 나누어 대상 시설을 선정하여 현장실측을 진행하였다. 계산 시 사용되는 데이터는 1년간 자료를 이용하여 설문조사된 데이터를 바탕으로 계산되었으며 이를 이용하여 방열손실 계산에 적용하여 분석하였다.
        12.
        2012.11 서비스 종료(열람 제한)
        Recently, infrared thermography that analyzes a blistering zone from surface temperature is widely used in stone cultural heritages. This study focused on quick detection and quantitative modeling of blistering zones. Blistering modeling for the stone cultural heritages should be carried out as following orders; aquisition of thermography image, establishment of critical temperature, monochromatic processing, extraction of vector line, mapping of blistering zone, and calculation of deterioration rate. The deterioration rate of blistering zones of Cheomseongdae observatory and Sungnyemun stone block foundation using the infrared thermography were 1.5% and 6.6%, respectively.
        13.
        2012.05 서비스 종료(열람 제한)
        I investigated heat insulation condition and analyzes connection of construction period, heat insulation property for making databases related of heat insulation deterioration and repair reinforcement in existing building
        14.
        2012.05 서비스 종료(열람 제한)
        Deterioration of insulation and retrofitting existing buildings to make the data necessary for the insulation of the survey should precede. Measuring infrared (IR systems) using insulation on-site apartment Segmental analysis of the structure is to evaluate the let part. Temperature and temperature gradient by the degradation of the insulation of apartment structures can be evaluated.
        15.
        2008.05 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 비접촉 손상검출기법으로 관심의 대상이 되고 있는 열화상 기법의 기본 원리, 활용 예, 제한 사항 등을 국내외 주요 연구성과를 분석하고 정리하였다. 콘크리트 구조물의 내부 결함 진단, 내부 철근 부식 측정과 콘크리트 구조물 표면과 섬유 보강 시트 사이의 비부착 검출, 포장도로의 표면 결함 검출, 오래된 건물의 표면 누수 측정, 철도 트랙 자갈의 상태 측정 등을 최근 연구결과 중심으로 광범위하게 검토하였고 최근에 보고된 실험결과도 제시하였다. 검토 결과, 열화상 기법은 광범위한 형태의 토목 구조물의 넓은 표면을 빠르게 정성적으로 검사할 수 있는 장점을 가지고 있는 것으로 확인되었다. 반면, 정량적 기법은 주변 온도 등 환경 요인에 민감하게 영향을 받는 것으로 판단되었으며, 다른 정밀계측장비와 혼용시 좋은 성과를 기대할 수 있을 것으로 예측된다.