        1.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Most of the steam turbine control valves used for the fossil and nuclear power plants operation in South Korea were developed by GE (General Electric) and manufactured by DHIC (Doosan Heavy Industry Company). For may years, DHIC have tried to develop their own technologies related to the power generation. DHIC has launched many R&D projects and ‘Development of a Control Valve Flow Code for Steam Turbine Operation Control of Fossil Power Plant’ was one of the R&D projects. Through our project, we accomplished the experimental method to obtain a steam turbine control valve characteristic curve using the atmospheric air and the reduced model instead using the steam and the real model. Also, we developed the correction method to calculate the real steam mass flow rate from the characteristic curve obtain by the experiment. In this paper, the effectiveness of the correction method was reviewed and it was concluded that the corrected mass flow rate complies well with the real steam mass flow rate.
        4,000원
        2.
        2022.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we intend to develop a control valve with oxidation resistance for hydrogen fluoride that can be applied to the semiconductor production process. Operated Valves currently in use is a form of assembling an air cylinder to the valve body. These valves generally have a cylinder body made of aluminum (Al), so they may corrode depending on the external environment, and the solution leaks along the rod inside the cylinder, causing damage to parts due to corrosion. To solve this problem, the valve plug shape was developed by devising and applying a plug using a valve different from the existing method, and it is possible to block the inflow of hydrogen fluoride into the valve control unit, thereby preventing damage to parts as well as maintaining stable valve operation.
        4,000원
        3.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Calorifier is a device that supplies hot water to the crew for showering and cooking. In particular, problems such as hot water not coming out when a trainee and a crew member take a shower at the same time may occur due to a malfunction of the temperature control valve that controls the temperature. In particular, when the hot water usage time is almost constant, such as a training ship, a high calorific value is required. When there is no dissatisfaction with the use of hot water, satisfaction with the educational environment is improved. Therefore, in this study, a solenoid temperature control valve is applied to increase satisfaction with hot water use, and a mechanical time switch is applied to the hot water circulating water pump to save energy.
        4,000원
        4.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 전후진 자동변속기가 장착된 트랙터의 변속 충격을 모사하기 위한 시뮬레이션 모델에 적용될 비례 제어 밸브의 전류 제어 모델을 개발하는 것이다. 전류 제어 모델을 개발하기 위하여 시험 장치를 구성하여 밸브의 정특성 시험과 계단 응답 시험을 수행하였으며, 시험 결과를 토대로 전류 제어 모델을 검증하였다. 비례 제어 밸브의 전류 제어 모델은 밸브의 전류-압력 선도, PID 제어기, 펄스폭변조 신호 발생기와 밸브 모델로 구성하였다. 전류 제어 모델에 사용된 데이터는 시험을 통하여 도출된 값과 대상 트랙터에 적용된 값을 사용하였다. 전류 제어 모델 검증을 위해 계단 입력 신호에 대하여 전류 특성 시험을 수행하였고, 실제 전류 시험 결과와 시뮬레이션 결과를 비교하였다. 시험 결과와 시뮬레이션 결과에 대한 전류 특성을 비교해 보면, 상승 시간 오차는 0.0074초, 첨두치 시간의 오차는 0.0065초, 오버슈트 오차는 0.06%로 나타났다. 따라서 개발된 비례 제어 밸브의 전류 제어 모델은 실제 제어기의 전류 제어 특성을 제대로 반영할 수 있으며, 추후 변속 충격 모사를 위한 트랙터 시뮬레이션 모델에서 비례 제어 밸브의 전류 제어 모델로 사용될 수 있을 것으로 판단된다.
        4,000원
        5.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The 3-way valve have been used as a valve for opening and closing the valve by the flow control in the pressure system of the cryogenic and high pressure environment. In this paper, numerical analysis and experimental study on fracture nipple of 3-way ultra high pressure valve applied to space launch vehicle was carried out. We have developed a 3-way valve numerical simulation modeler of cryogenic environment using commercial software ANSYS 18.2. As results of numerical analysis, optimum nipple condition was derived. In addition, a 3-way valve prototype was fabricated and the fracture test was performed and compared with the numerical analysis results.
        4,000원
        6.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, we analyzed the characteristics of the mass flow rate and velocity of the refrigerant in response to a change in the number of holes and the diameter size(Type-1~4) of the valve guide refrigerant to flow from Pc to Ps when the pressure is constant. Type-1 is 40% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-2 is 64% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-3 is 50% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate. Type-4 is 47% higher mass flow flowing in the direction of Ps as compared with the Pc mass flow rate.
        4,000원
        7.
        2013.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the actual energy consumption of the secondary side of district heating system(DHS) with different hot water supply temperature control methods are compared. Two methods are outdoor temperature reset control and outdoor temperature predictive Control. While outdoor temperature reset control has been widely used for energy savings of the secondary side of the system, the results show that outdoor temperature predictive control method saves more energy. In general, outdoor temperature predictive control method is lowering the supply temperature of hot water, and it reduces standby losses and increases overall heat transfer value of heated spaces due to more flow into the space. During actual energy consumption monitoring, outdoor temperature predictive control method saves about 19.1% when it compared to outdoor temperature reset control method. Also, it is found that when partial load condition, such as daytime, the fluctuation of hot water supply temperature with outdoor temperature reset control is more severe than outdoor temperature prediction control. So, it proves that outdoor temperature prediction control is more stable even at partial load conditions.
        4,000원
        8.
        2008.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigates experimentally Air-fuel ratio feedback control with a fuel valve in a LPG engine. The fueling valve is controlled by electronic control unit which is made with micro computer. Various control logics are employed and then PID control is adopter as a proper logic for own system and Air-fuel ratio feedback control by PID control was experimentally of various operation area with the stable control algorithm of PID control that was earned from the former experiment. On the process the experiment, determination experiment of each control part coefficient was the biggest variable among the whole result of experiment. We could know as a result of experiment that the lange of overshoot is bigger as the proportional control part os bigger integral control part is related with the delay time and coefficient of differential control part is related with the decrease of overshoot range from the experiment of various operation area we could also analyse consequently that direct fuel control in the fuel value makes more stable control status in rare operation and low load area.
        4,000원
        13.
        1990.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 유량제어 조직밸브의 기초특성을 집중정수계 모델을 사용하여, 해석하고, 이것을 실험적으로 확인하였다. 그 결과를 요약하면 아래와 같다. 1. 로직밸브의 주밸브 유량은, 그것보다 매우 소유량인 파일럿 유량에 의하여 제어할 수 있다. 2. 주밸브(파핏밸브)~파일럿실간의 개구면적이 주밸브 변위에 비례하도록 밸브를 설계함으로써 주밸브변위(혹은 면적)와 부하유량사이에 양호한 직선성이 얻어진다. 3. 유량제어 로직밸브에서 주밸브 유량의 제어범위의 상한은 기름홈의 개구면적의 최대치에 의하여 결정한다.
        4,000원
        14.
        1988.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A cartridge type hydraulic logic valve consists of simple two port valve whose poppet is closed or opened by means of pressure signal of a pilot line. Accordingly, the logic valve can be used not only for direction, flow and pressure control purpose but also for versatile function valve which enables all above mentioned functions. In addition, the valve has little internal leakage and pressure loss, superior response characteristics and easiness in making small block type valve. The above mentioned good performances being recognized recently, the logic valve has been used widely in the large scale hydraulic system such as a hydraulic press system, for the performance requirements of high speed operation and precise control characteristics. However, there are scarce reports until now, except for a few ones from Aachen Institute of Technology in West Germany, so it is necessary to be studied on development and investigation for practical application. This paper showed that the static and dynamic characteristics of a logic valve when the logic valve is used for directional control, to investigate the relations between the valve operating characteristics and the valve design conditions. From the above mentioned procedure, it was ascertained that the valve operation characteristics obtained by numerical analysis showed good agreements with experimental results. The representative results obtained are as follows; 1. During the valve is closing, the poppet velocity is almost constant in the logic valve. 2. The pilot pressure P sub(3) and the resistance R in the pilot line have much influences on the valve operation time. 3. Spring strength have not such a severe influence on the valve operating time. 4. The operation characteristics of the logic valve can be estimated with good accuracy comparatively by numerical analysis with the equations describing poppet motion.
        4,000원
        15.
        2015.10 KCI 등재 서비스 종료(열람 제한)
        해수침투 방지나 대수층 인공함양을 위하여 다수의 관정을 통하여 대수층으로 물을 주입하는 공법이 있다. 이러한 공법의 경우 소기의 목적을 달성하기 위해서는 관정의 위치와 주입량, 그리고 결과되는 관정의 지하수위 등이 별도의 지하수 모델링을 통하여 결정된다. 주입수는 통상 관망을 통하여 관정으로 공급되는 데 이 때 관망에는 관정별 주입량을 조절하기 위한 밸브가 설치된다. 본 연구에서는 다수의 주입 관정이 연결된 관망에서 사전에 산정된 주입량 분포를 준수하기 위한 밸브 개도와 주입관망 가동에 필요한 펌프 최소 소요양정 산정방안을 제시하였다. 본 연구결과는 주입군정 운영의 정밀도를 향상시키는 데 기여할 수 있다.