Many older reinforced concrete (RC) buildings were constructed and designed with only gravity loads in mind. Columns in those buildings have insufficient reinforcement details that do not satisfy the requirements specified in current seismic design standards. This study aims to develop drift-based fragility functions for lightly RC columns. For this purpose, a database of 193 lightly RC columns was constructed to determine central and dispersion values of drift ratios for individual damage states. Additionally, to develop more accurate fragility functions of the columns, the failure mode of RC columns was incorporated into fragility functions. The classification procedure for column failure mode is proposed in this study. Fragility functions for older RC columns are constructed according to four different damage states. The main variables of the fragility functions proposed in this study are column properties and failure mode.
시공 중인 건물은 시공이 완료된 건물과는 다르게 콘크리트의 강도발현이 충분히 이루어지지 않았기 때문에 지진과 같은 자연재해 에 더 취약한 모습을 가질 수 있다. 현재 국내 기준은 건축물의 내진등급별 최소성능 목표를 제시하고 있지만, 설계를 위한 지진하중은 재현주기 2,400년의 지진위험도를 기반으로 한다. 하지만 건물의 시공기간은 건물의 사용기간보다 훨씬 짧기 때문에 재현주기 2,400 년의 지진을 시공 중인 건물에 적용하는 것은 과도하다. 따라서 이 연구는 주거용으로 사용되는 철근콘크리트 건물의 시공 중 지진하 중을 분석하기 위해 5층, 15층, 25층, 60층 건물의 시공단계모델을 작성하고 재현주기에 따라 저감한 지진하중을 적용하여 구조적 안 정성을 확인하였다. 그 결과, 시공기간에 따라 선정한 재현주기의 지진을 적용할 때 구조적 안정성을 확인하였으며, 건물의 규모의 따 라 구조적 안전성을 확보할 수 있는 지진재현주기를 확인하였다.
초고층 건물에서 수평변위 제어와 수직부재에서 발생하는 부등축소에 대한 검토가 필수적이다. 수평변위 제어를 위해 근래에 아웃 리거 구조시스템과 메가 구조시스템을 횡력저항시스템으로 사용한 초고층 건물이 증가하고 있다. 또한, 부등축소로 인한 구조적 문 제를 해결하기 위해 부등축소량 예측과 예측결과를 통한 시공단계에서의 보정방법이 연구되어 왔으나 부등축소에 대한 횡력저항시 스템의 영향 비교는 드문 편이다. 따라서, 본 논문에서는 수평변위 제어를 위해 아웃리거 구조시스템과 메가 구조시스템을 사용한 60 층 규모의 철근콘크리트 주거용 초고층 건물에 대해 시공단계해석을 통한 부등축소를 비교하고 그 영향을 분석하고자 한다. 또한, 부 등축소는 비구조요소의 파손 및 구조요소에 부가하중을 유발하기도 하며 부등축소가 야기한 문제는 초고층 건물에서 중요한 부재를 손상시킬 수 있으므로 각 횡력저항시스템별로 수직부재의 부등축소에 대한 영향을 분석하였다.
강진 시 원자력발전시설의 비선형 응답이 중요하기 때문에 이 시설의 내진성능에 대한 관심이 증가하였다. 이 연구에서는 원자력 발전소 철근콘크리트 전단벽의 유한요소해석을 위한 재료모델의 적절한 변수를 제시하였다: 최대인장강도, 팽창각, 손상계수. 이를 위해 상용 유한요소 해석프로그램인 ABAQUS를 사용하여 낮은 형상비를 가진 철근콘크리트 전단벽의 비선형 거동과 전단 파괴모드 에 대한 이 주요 변수의 효과에 대한 연구를 수행하였다. 연구결과에 기반하여 비선형 시간이력해석을 통해 강진 하의 원자로건물의 비선형 응답을 평가하였다.
Communication facilities play an essential role in disaster situations. Therefore, communication facilities need to have structural and functional safety during and after earthquakes. Recently, technology for partial seismic isolation has been increasing to protect data facilities and communication equipment installed in buildings from earthquakes. However, excessive displacement may occur in the seismic isolator during an earthquake due to the resonance between the building and the seismic isolator having long-period characteristics, which may cause overturning and separation of the installed equipment. In this study, analytical and experimental studies were conducted to evaluate the safety of seismic isolators installed in high-rise buildings. It was confirmed that damages might occur in buildings' seismic isolator, with resonance characteristics of less than 1 Hz.
Existing old reinforced concrete buildings could be vulnerable to earthquakes because they were constructed without satisfying seismic design and detail requirements. In current seismic design standards, the target collapse probability for a given Maximum Considered Earthquake (MCE) ground-shaking hazard is defined as 10% for ordinary buildings. This study aims to estimate the collapse probabilities of a three-story, old, reinforced concrete building designed by only considering gravity loads. Four different seismic design categories (SDC), A, B, C, and D, are considered. This study reveals that the RC building located in the SDC A region satisfies the target collapse probability. However, buildings located in SDC B, C, and D regions do not meet the target collapse probability. Since the degree of exceedance of the target probability increases with an increase in the SDC level, it is imminent to retrofit non-ductile RC buildings similar to the model building. It can be confirmed that repair and reinforcement of old reinforced concrete buildings are required.
Most commercial buildings among existing RC buildings in Korea have a multi-story wall-frame structure where RC shear wall is commonly used as its core at stairways or elevators. The members of the existing middle and low-rise wall-frame buildings are likely arranged in ordinary details considering building occupancy, and the importance and difficulty of member design. This is because there are few limitations, considerations, and financial burdens on the code for designing members with ordinary details. Compared with the intermediate or unique details, the ductility and overstrength are insufficient. Furthermore, the behavior of the member can be shear-dominated. Since shear failure in vertical members can cause a collapse of the entire structure, nonlinear characteristics such as shear strength and stiffness deterioration should be adequately reflected in the analysis model. With this background, an 8-story RC wall-frame building was designed as a building frame system with ordinary shear walls, and the effect of reflecting the shear failure mode of columns and walls on the collapse mechanism was investigated. As a result, the shear failure mode effect on the collapse mechanism was evident in walls, not columns. Consequently, it is recommended that the shear behavior characteristics of walls are explicitly considered in the analysis of wall-frame buildings with ordinary details.
The methodology classifying structural types of concrete buildings in the existing seismic fragility functions is too simple to estimate the fragility of existing residential buildings and neighborhood living facilities, especially those below five stories. Their structural types are dependent on information contained in the building register such as main use, total floor area, story, permission date, and first story floor area of the individual building. All of this information is not considered for classifying types in the existing functions; therefore, the goal of this study was to suggest a methodology that classifies structural types of concrete buildings by utilizing such information. The results of this study showed that the suggested methodology can classify structural types better than the existing methodology. Nevertheless, there is still a need to simplify the methodology because fragility estimation demands quickness rather than accuracy.
This paper is to investigate the retrofitting effect for a non-seismic reinforced concrete frame strengthened by perimeter steel moment frames with indirect integrity, which ameliorates the problems of the direct integrity method. To achieve this, first, full-scale tests were conducted to address the structural behavior of a two-story non-seismic reinforced concrete frame and a strengthened frame. The non-seismic frame showed a maximum strength of 185 kN because the flexural-shear failure at the bottom end of columns on the first floor was governed, and shear cracks were concentrated at the beam-column joints on the second floor. The strengthened frame possessed a maximum strength of 338 kN, which is more than 1.8 times that of the non-seismic specimen. A considerable decrease in the quantity of cracks for the strengthened frame was observed compared with the non-seismic frame, while there was the obvious appearance of the failure pattern due to the shear crack. The lateral-resisting capacity for the non-seismic bare frame and the strengthened frame may be determined per the specified shear strength of the reinforced columns in accordance with the distance to a critical section. The effective depth of the column may be referred to as the longitudinal length from the border between the column and the foundation. The lateral-resisting capacity for the non-seismic bare frame and the strengthened frame may be reasonably determined per the specified shear strength of the reinforced columns in accordance with the distance to a critical section. The effective depth of the column may be referred to as the longitudinal length from the border between the column and the foundation. The proposed method had an error of about 2.2% for the non-seismic details and about 4.4% for the strengthened frame based on the closed results versus the experimental results.
This study is to investigate the effect of a retrofitted reinforced concrete frame with non-seismic details strengthened by embedded steel moment frames with an indirect joint, which mitigates the problems of the direct joint method. First, full-scale experiments were conducted to confirm the structural behavior of a 2-story reinforced concrete frame with non-seismic details and strengthened by a steel moment frame with an indirect joint. The reinforced concrete frame with non-seismic details showed a maximum strength of 185 kN at an overall drift ratio of 1.75%. The flexural-shear failure of columns was governed, and shear cracks were concentrated at the beam-column joints. The reinforced concrete frame strengthened by the embedded steel moment frames achieved a maximum strength of 701 kN at an overall drift ratio of 1.5% so that the maximum strength was about 3.8 times that of the specimen with non-seismic details. The failure pattern of the retrofitted specimen was the loss of bond strength between the concrete and the rebars of the columns caused by a prying action of the bottom indirect joint because of lateral force. Furthermore, methods are proposed for calculation of the specified strength of the reinforced concrete frame with non-seismic details and strengthened by the steel moment frame with the indirect joint.
본 논문에서는 반응표면법과 다목적최적화 기법을 이용한 유한요소모델개선기법의 절차를 제안하고 이를 저층의 철근콘 크리트건물의 모델개선에 적용하였다. 대상건물은 전단벽 신설 및 댐퍼부착을 위한 부재의 강재보강을 통해 내진보강이 이 루어진 건물로서 보강전후에 소형 가진기를 이용한 진동실험을 실시하여 동특성을 구하였다. 대상건물의 개선에 사용된 변 수는 기존콘크리트, 신규타설된 콘크리트, 조적의 탄성계수, 신축줄눈부의 스프링계수, 강재보강된 부재의 유효강성비이다. 보강전후 건물의 초기모델을 구축한 후 중심합성법에 따라 개선변수의 값을 변화시키면서 얻은 해석결과를 통해 고유진동 수의 오차와 모드형상의 오차를 나타내는 2개의 반응함수를 구하고, 이를 다목적최적화의 목적함수로 사용하였다
근래 국내 초고층 주상복합 건물에는 철근콘크리트구조가 보편적으로 적용되는데, 이러한 철근콘크리트 초고층 주상복합 건물은 시공 시점에 따라 구조적인 문제가 발생할 수 있다. 따라서, 시공 중인 철근콘크리트 초고층 주상복합 건물에 대하여, 시공 시점별 구조 안전성 및 횡력저항성능을 검토하고자 한다. 이를 위해, 예제 모델로 탑상형의 초고층 주상복합 60층 건물을 선정했고, 기존의 범용구조해석 프로그램을 사용하여 구조해석을 수행하였다. 각 시공 시점별 10층, 20층, 30층, 40층, 50층, 60층 완료모델과 60층 완공단계 모델의 구조성능을 비교하였다. 구조성능 비교를 위해 이 모델들의 고유치해석을 수행하였으며, 횡력저항성능과 부재별 단면성능을 검토하였다. 횡력저항성능 검토를 위해 횡변위비와 층간변위비를 검토했고, 부재별 단면성능 검토는 완공단계에 대한 설계강도비와 시공단계의 설계강도비를 비교하여 부재안전성을 검토하였다. 이 연구를 통해, 시공 중인 철근콘크리트 초고층 건물의 구조 안전성을 검토하고 시공단계에 적합한 구조해석 및 설계하중의 가이드라인을 제시하고자 한다.
본 논문에서는 현재 시공중인 58층의 철근콘크리트조 고층건물에서 진동현식게이지를 통해 계측된 기둥의 축방향 변형률과 레이져 스캐닝을 통해 구한 횡변위를 3차원 시공단계해석에 의한 예측치와 비교하였다. 예측치는 ACI 209와 PCA의 재료모델식, PCA report의 축소량 산정알고리즘을 3차원 구조해석 프로그램으로 개발한 ASAP을 사용하여 구하였다. 비교결과 평면의 중앙부 기둥의 축방향 변형율 계측치는 시공단계 해석치와 거의 유사한 결과를 나타내었으나 각 모서리에 두 개씩 배치된 기둥의 경우 비교적 큰 오차를 나타내었다. 레이져 스캐닝에 의한 횡변위 계측결과는 해석결과와 유사한 경향을 보였으나 층당 계측치가 큰 변동을 나타내므로 향후 이를 해결하기 위한 계측 및 데이터 처리기법이 요구된다.
In this study, shaking table test was carried out to evaluate the seismic behavior and performance of low-rise reinforced concrete (RC) piloti structures with and without retrofit. The specimens were designed considering the characteristics of existing building with pilotis such as natural period, distribution factor of strength and stiffness between columns and core wall on the first soft story. The test for the non-retrofit specimen showed that damage was concentrated on the stiffer member on the same floor as the core wall failed by shear fracture whereas columns experienced slight flexural cracks. Considering the failure mode of the non-retrofit specimen, the retrofit method using steel rod damper was presented for improving the seismic performance of piloti structures. The results of the test for retrofit specimen revealed that the retrofit method was effective for controlling the damage as the main RC structural members were not destroyed and most of input energy was dissipated by hysteretic behavior of the damper.
구조물이 건전한 상태에서 진동계측을 통한 고유진동수와 감쇠율과 같은 동적특성의 분석에 대하여 국내 외적으로 많은 연구가 진행되어 왔다. 그러나 실물 구조물에 대하여 파괴 직전까지의 큰 손상 후에 진동계측을 통한 동적특성에 대한 연구는 상대적으로 매우 미약한 실정이다. 따라서 본 연구는 3층 철근콘크리트조 건물에 엑츄에이터로 하중을 주어 건물에 손상을 준 후에 손상 전 후의 진동계측을 통하여 동적특성을 파악하였다. 손상 전 후에 대한 고유진동수 및 감쇠율을 산정하였으며, 이 결과를 국외의 기존 연구와 비교하였다. 상시진동계측 및 인력가진을 통한 계측방법을 실시하였으며, 계측 전에 고유치 해석을 선행하여 계측치와 비교분석을 하였다. 120mm의 수평변위를 준 결과 구조물의 파괴 직전 손상 전 후에 장변과 단변의 고유진동수는 각각 34.3%, 33.7% 감소하였고, 감쇠율은 각각 36.5%, 19.5% 감소하였다. 기존 국외의 연구결과와의 비교를 한 결과 고층형 건물보다 강성의 변화가 크게 감소됨을 확인할 수 있었으며, 저층형 구조물에 대한 안정성 검토가 시급함을 확인할 수 있다.
본 연구에서는 전단벽-모멘트골조 시스템으로서 전단벽이 주로 횡력을 부담하는 철근콘크리트 건물을 대상으로 다양한 설치형식과 마찰력의 총량 및 분포를 갖는 마찰형 감쇠기의 제진보강 효과를 수치해석을 통해 비교 분석하였다. 감쇠기의 설치형식으로서 전단벽에 인접한 대각가새형, 벽체가 없는 골조를 보강하는 대각가새형 및 벽체 단부를 보강하는 수직경계요소형을 고려하였다. 하중기준 강화로 설계용보다 크게 증가한 지진하중에 대해 건물의 재료비선형성을 고려한 비선형시간이력해석을 수행하여 에너지소산, 횡하중 및 부재손상도 측면에서 마찰형 감쇠기의 제진성능을 비교 분석하였다. 기준마찰력의 30% 수준의 총마찰력을 갖는 벽체보강 대각가새형 설치형식이 전반적으로 가장 우수한 제진성능을 보이며,이 경우에 마찰력 배분방식은 중요하지 않았다. 또한 일부층에 집중설치함으로써 전층설치에 약간 못미치는 제진성능을 얻을 수 있었다.
본 연구의 목적은 하부층에 필로티 구조, 상부층에 전단벽식구조를 가진 저층 철근콘크리트 건물의 내진설계 및 내진성능 평가를 위한 기본적인 자료를 제공하는 것으로서, 비선형 지진응답해석을 실시하여 각 층의 내력과 연성율 사이의 상관관계를 파악하여, 이것들의 비율이 건물 전체의 내진성능에 어떻게 영향을 미치는가를 검토하였다. 본 연구에서는 필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 특성을 2질점계로 치환하였으며, 하부층인 필로티 구조는 휨파괴형으로 상부층인 전단벽식 구조는 전단파괴형 시스템으로 각각 모델링하였다. 또한 각층의 복원력 특성으로는 필로티 구조는 Degrading Trilinear Model(휨파괴형), 상부층은 Origin Oriented Model(전단파괴형)을 선정하였다. 상기 복원력 특성은 각 층의 보유내력에 의하여 변화를 하며, 지진응답해석용 입력지진파로는 8개의 피해지진의 가속도 성분을 선정하여 이들 가속도 성분의 최대가속도를 0.1g, 0.2g, 0.3g로 표준화 하였다. 각각 지진강도수준에 따라 지진 응답해석을 실시하여 하부층 필로티 구조와 상부층 전단벽식 구조의 내력비와 응답 연성율 사이의 상관관계를 파악하였다. 최종적으로 특정 연성율을 위한 필로티 구조를 가진 저층 철근콘크리트 전단벽식 건물의 요구내력을 산정하여 요구내력 스펙트럼(Required Strength Spectrum)을 제안하였다. 본 연구에서 제안한 요구내력스펙트럼은 특정 지역에서 요구하는 지진수준에 대하여 지진발생시 특정 연성율 이내로 머물게 하는 하한내력의 범위를 파악할 수 있는 등, 연구결과는 필로티 구조를 가진 철근콘크리트 전단벽식 건물의 내진성능평가 및 내진설계의 기본적인 자료로서 활용 가능하다고 사료된다..2-propanedial 1.5 M 실험구에서는 실험개시시 30\;{\times}\;10^4\;cell/ml이던 것이 3 일 후 138\;{\times}\;10^4\;cell/ml였고, 실험종료시인 5 일 후에는 385\;{\times}\;10^4\;cell/ml로 증식되어 가장 높은 증식률을 보였다. 참굴 D상 유생을 대상으로 먹이효과를 조사한 결과 실험구와 대조구간 유생의 성장 및 생존율에 유의한 차이를 보이지 않았다.C에서 73.3%, 10^{\circ}C에서 63.3% 및 5^{\circ}C에서 56.7%로 수온이 30^{\circ}C 이내에서는 높을수록 높은 경향을 보였다. 염분에 따른 잠입 실험 결과는 실험 개시 300분 경과 후 염분 30 psu에서 93.3%로 가장 높았고, 35 psu에서 90.0%, 25 psu에서 83.3%, 20 psu에서 60.0%, 15 psu 이하에서는 거의 잠입이 이루어 지지 않았다. 따라서, 적정 살포를 위한 잠입률은 치패의 크기와 상관없이 저질종류는 모래 (75%) + 뻘 (25%), 입자크기는 1 mm 모래에서 높게 나타났다. 공기 중 노출시간은 짧을수록, 수온은 30^{\circ}C 이내에서 높을수록, 염분은 20-35 psu 이내에서 높을수록 잠입률이 높은 경향을 나타내었다. 교수학습모형에 관련된 지식을 묻는 내용으로 주로 출제되었다. 이에 구체적인 개선방안으로 특정 교수학습모형의 이론적 토대가 되고 전체적인 교수설계를 하기 위한 기본 바탕이 될 수 있는 교수학습이론에 관한 내용, 또한 현재가정과교육에
본 연구에서는 확률과 신뢰성을 바탕으로 개발된 FEMA-355F의 내진성능 평가기법을 적용하여 철근 콘크리트 모멘트골조 건물의 내진성능을 평가하였다. 철골 구조물을 대상으로 개발된 FEMA의 성능평가 방식을 다른 구조 시스템에 적용할 때 각 시스템에 적합한 성능값을 결정해야하며, 요구값과 성능값 계산 시 수반되는 불확실성을 반영하는 계수들을 새로이 구해야 한다. 이를 수행하기 위해 예제 건물을 IBC 2003에 따라 설계한 후, 성능평가에 필요한 변수들을 결정하기 위해 건물의 위치에 적합한 지반운동을 이용하여 비탄성 동적 해석을 수행하였다. 해석결과에 따르면 계산된 성능값의 분포는 요구값에 비해 상대적으로 작았으며, 이 결과는 본 연구에서 결정된 성능값이 합리적임을 나타낸다. 구해진 신뢰도는 부분 및 전체 붕괴 모두에 대해 목표치를 초과하였으므로 예제 건물은 목표 성능을 만족하는 것으로 나타났다.
노스리지 지진에 의해 손상을 받은4층 철근콘크리트조 골조건물을 대상으로 선형가진기 및 대용량의 편심가진기를 이용한 강제진동실험과 상시미진동 측정을 실시하였다. 미진동 가속도데이터 및 선형가진기에 의한 백색잡음 실험시의 가속도데이터로부터 구조물식별을 수행하여 7차모드까지의 고유진동수 및 모드감쇠비를 얻었다. 두대의 대용량 편심가진기를 사용하여 얻은 큰 진폭의 조화 진동하에서는 가속도데이터를 사용하여 각 방향 1차모드를 식별하였으며 변위계와 변형게이지를 이용하여 층간변위각, 기둥과 슬래브와 같은 구조부재의 곡률분포를 측정하였다. 각 경우 고유진동수는 진동의 크기가 클수록 낮아졌다. 즉, 편심가진기가력시 고유진동수는 상시미진동시에 비해 70{\sim}75%, 선형가진시가력시에 비해 92{\sim}93% 정도로 낮게 나타났다. 이러한 진동수의 감소폭은 지진에 의해 큰 손상을 받았던 건물의 남북방향에서 크게 나타났다.
격납건물은 원자로 사고발생시 방사능물질의 외부 유출을 막는 최후의 방벽이므로 가동 중 원전의 격납건물에 대한 안전성평가는 반드시 수행되어야 된다. 이러한 맥락에서 이 논문은 원전 격납건물의 비선형해석을 위해 탄소성 모델을 바탕으로 개발된 8절점 가변형도 쉘 요소와 이를 이용한 구조물의 비선형해석에 대하여 기술하였다. 비선형해석을 위해 콘크리트의 압축거동에 Drucker-Prager 파괴기준을 적용하였고 파괴포락선의 형상을 결정짓는 재료매개변수는 이축응력 실험으로부터 도출하였다. 개발된 쉘 유한요소는 퇴화 고체기법과 횡 전단변형도를 고려하기 위하여 Reissner-Mindlin(RM)가정을 도입하였고 쉘의 두께가 얇거나, 즉 종횡비가 작거나, 균일하지 않은 유한요소망을 사용할 경우 구조물의 강성이 과대하게 평가되는 묶임현상(locking phenomenon)을 제거하기 위해 본 논문에서는 가변형도법을 도입하였다. 개발된 철근콘크리트 쉘 요소의 성능검증을 위해서 벤치마크 테스트를 수행하였고 그 결과 이 논문에서 도출한 유한요소해석 결과는 실험결과와 잘 일치 하였다