        1.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Korea is a country where the population is concentrated in metropolitan areas that have undergone rapid industrial development. As of 2020, more than 43% of the total population lives in large cities, and about 18.5% of the total population lives in Seoul. A basic human need living in such a metropolis is a pleasant environment. In this study, complex odors and designated odors were evaluated at the boundary areas and at the outlets for 15 public environmental facilities selected from among odor sources in Seoul. As a result of measuring the complex odor intensity was 3 ~ 6 times at the boundary areas and 100 ~ 4,481 times at the outlets. In food waste treatment facilities, incineration facilities, and waste transfer station facilities, the compound making the largest contribution to odor is acetaldehyde, which was recorded at 46%, 25%, and 32% respectively. At a sewage treatment facility and agro-fisheries wholesale market, hydrogen sulfide was the largest contributing compound at 71% and 29% respectively.
        4,000원
        2.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The types and distribution ratio of odor removal systems installed in publicly owned environmental facilities such as sewage treatment, wastewater treatment, manure treatment, livestock manure treatment, and food waste treatment were investigated. Since the intensity of the odor and the composition of the odor substances are different depending on the type of each public treatment facility, different odor removal efficiencies were derived depending on the applied odor removal technology. In addition, the removal efficiency of complex odors and individual odor substances of odor removal systems such as those applying biofilters, scrubbers, and adsorption towers were also compared and evaluated. Although it depends on each odor removal technology and application facility, about 50% of various odor removal systems presented an odor removal performance of less than 30%. The odor removal systems with an odor removal efficiency of 70% or more were evaluated to be less than 30% of the total number. Therefore, we suggest that odor removal efficiencies should be improved through continuous monitoring, diagnosis, reinforcement of maintenance, and improvement of systems.
        4,800원
        3.
        2021.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Environmental fundamental facilities have different odor emission characteristics depending on the type of treatment facilities. To overcome the limitations of the olfactometry method, research needs to be conducted on how to calculate the dilution factor from the individual odor concentrations. The aim of this study was to determine the air dilution factor estimated from manually measured concentration data of individual odor substances (22 specified odor species) in three environmental treatment facilities. In order to calculate the optimum algorism for each environmental fundamental facility, three types of facilities were selected, the concentration of odor substances in the exhaust gas was measured, and the contribution of the overall dilution factor was evaluated. To estimate the dilution factor, four to six algorism were induced and evaluated by correlation analysis between substance concentration and complex odor data. Dilution factors from O municipal water treatment (MWT) and Y livestock wastewater treatment (LWT) facilities showed high level of dilution factors, because concentration levels of hydrogen sulfide and methylmercaptan, which had low odor threshold concentrations, were high. In S food waste treatment (FWT) facility, the aldehyde group strongly influenced dilution the factor (dominant substance: acetaldehyde, i-valeraldhyde and methylmercaptan). In the evaluation of four to six algorism to estimate the dilution factor, the vector algorism (described in the text) was optimum for O MWT and Y LWT, while the algorism using the sum of the top-three dominant substances showed the best outcome for S FWT. In further studies, estimation of the dilution factor from simultaneously monitored data by odor sensors will be developed and integrated with the results in this study.
        4,000원
        4.
        2010.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to show the odor emission characteristics between the well maintained environment fundamental facility and the poorly maintained environmental facility. It also draws major components of odor emission based on facilities, stages, and suggest the proper way to reduce the level of odor for insufficient facilities. Insufficient facilities" air direct sensory and air dilution value levels are following: foodwaste > livestock > wastewater > night-soil > sewage. For the sewage and waste water facilities, the common characteristic of odor emission on each fundamental facility showed higher air dilution value in depositing reservoir and concentrator. And sulfur and aldehyde compounds came out to be the major odor causing components. In the case of night-soil and livestock facilities, the air dilution value was high in flow equalization tank and liquid erosion tank. And sulfur as well as ammonia component was the major malodorous substance. Foodwaste facility showed higher air dilution value than other facility, which sulfur and acetaldehyde compounds were acting as major malodorous substances.
        4,000원
        5.
        1992.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        "존재하는 사물은 무엇이나 일정한 양으로 존재한다."라는 말이 있다. 계측은 바로 이 양을 결정하는 것이다. 계측 과정 또는 행위는 미리 정해진 표준과 피측정물 사이의 양적인 비교로써 이루어진다. 계측은 여러 가지 사물을 정량적으로 파악함은 물론이고, 자동 제어하기 위한 수단으로서의 방법이나 장치, 더 나아가 처리 등을 포함하는 넓은 의미를 갖고 있다. 따라서 사물의 현상이나 상태를 특징 짓는 양을 정의하거나 선정해서, 그것을 수치로 나타내는 조작은 계측의 일부라고 생각할 수 있다.
        4,000원
        6.
        2017.05 서비스 종료(열람 제한)
        우리나라의 폐기물 발생량은 인구증가, 경제성장, 삶의 질 향상에 의해 꾸준히 증가하고 있으며, 증가하는 폐기물에 ‘자원화’로 인식을 전환시켜 재사용, 재활용하기 위한 다양한 정책을 추진중에 있다. 또한 자원화 방법 외에 소각 등의 처리를 한 후 매립장에 매립하고 있다. 자원화 방법 외에 소각과 매립의 방법으로 발생되는 폐기물을 적정하게 처리하기 위해서는 환경기초시설의 설치가 필수적이고, 환경기초시설(매립시설, 소각시설)의 설계 및 용량을 결정하기 위해서는 발생되고 있는 폐기물에 대한 정확한 분석과정이 우선시 되어야 하며, 이 과정은 매우 중요하다고 할 수 있다. 더욱이 소각시설의 경우 대기오염, 악취, 자원에 대한 낭비 등의 문제를 야기할 가능성이 높기 때문에, 소각시설의 적정 운전을 위하여 폐기물에 대한 물리・화학적 분석과 발열량에 대한 기초자료는 소각시설 설계 시 매우 중요 인자로 활용되고 있다. 하지만 소각시설 설계 시 고려되었던 폐기물에 대한 기초 자료로 설정한 소각시설의 운전조건이 실제로 소각시설이 운영되었을 때를 얼마만큼 유지하고 있는지는 지속적인 조사가 필요할 것이다. 왜냐하면 시간이 지나면서 사람들의 소비패턴이 변하며, 발생되는 폐기물의 양과 성분도 변하기 때문이다. 이에 본 연구에서는 인구 22만 명 정도의 중소도시를 대상으로 소각시설이 운영되고 있는 지역을 선정하였고, 선정된 지역의 과거부터 현재까지의 발생되고 있는 생활폐기물의 특성을 분석하고자 하였다. 생활폐기물의 변화특성을 조사・분석하기 위하여, 겉보기밀도, 삼성분분석, 발열량분석 등을 수행하였다. 향후 이 자료는 충주시에서 소각시설 운영을 위한 최적의 운전인자를 도출하는데 중요 자료로 활용될 수 있으며, 폐기물관리 정책수립 및 처리에 기초자료로 제시하고자 한다.
        7.
        2017.04 KCI 등재 서비스 종료(열람 제한)
        The study focuses on 32 environmental facilities in Incheon Metropolitan City, South Korea, categorizes them by sector: sewage treatment, wastewater treatment, incineration, landfill, water purification, and water supply. Their GHG reduction results are analyzed through quantitative and qualitative measures for 2012 to 2015. The study surveys and examines GHG reductions of the environmental facilities for two categories - facility operation and management. The findings are as follows: First, the GHG reduction rate, an emission-to-allocation ratio, from 2012 to 2015 is 89.67%. Second, GHG reductions coming from qualitative measures of facility management are even greater than those from quantitative measures of facility operation. Third, GHG reductions through facility operation are mostly attributable to overhauls, less use of facilities, resources recycling, process improvement rather than the betterment of fuels, facilities and energy efficiency. Fourth, higher reduction can be achieved by effective facility management, qualitative measures.
        8.
        2014.07 KCI 등재 서비스 종료(열람 제한)
        본 연구의 핵심은 다양한 환경기초시설, 치수관련 시설물 등의 지자체별 개별적 건설과 운영에 따른 예산의 낭비와 비효율적 운영을 지양하는데 있다. 다음으로는 인접 지자체간의 협력적 운영을 통하여, 저출산 고령화 시대에 맞는 수자원시설의 효율성을 강화하여 규모의 경제를 달성하는 방안을 찾는데 있다. 지자체간의 협력을 유도하기 위해서는 관련시설의 투자비용의 합리적 배분이 필요하다. 이러한 합리적 비용배분의 방법으로 비례법, 샤플리방법, 분리비용잔여편익 산출법 등을 제안하고 있다. 지자체별로 건설 중인 하수처리장시설을 사례대상으로 하여 구체적인 적용방법을 제시하고 있다. 본 연구결과의 정책적인 시사점으로는 합리적 비용배분을 통하여 관련 지자체간의 갈등을 사전에 차단하는 동시에, 정부의 환경기초시설에 대한 지자체별 국고보조 방식보다는 유역의 협력적 예산으로 전환하는 것도 바람직한 정책으로 판단된다.
        9.
        2013.11 서비스 종료(열람 제한)
        본 연구에서는 혐기성 소화조에서 발생하는 이산화탄소를 충전탑으로 유입하여 MEA, DEA 및 AMP의 화학적 흡수제의 농도변화에 따른 이산화탄소 제거 효율을 검토하여 혐기성 소화조 내에 적용 가능성을 판단하는데 그 목적이 있다. 본 연구에서 실험에 사용된 충전탑은 유리제 Raschig Ring 6×6 mm를 충전한 직경 50 mm, 충전 높이 1.40 m를 사용하였으며, 액체부하는 20 ℓ/hr, 가스부하는 130 ℓ/hr로 고정하여 CO2의 농도를 10%, 20%, 30%로 주입하였을 때 MEA 10% 및 20%에서와 AMP 10의 CO2 제거율을 관찰하였다. 또한 Packed Tower의 지름은 0.288 m, 충전층의 높이는 1 m이며, 실험시스템은 Air, Air/Water 및 Air-CO2/MEA 흡수제로 하였다. 실험결과에 대한 평가는 계산 프로그램을 통하여 추출하였으며, 분리작용 HTUov, 통과단위수 NTUov, 그리고 정확한 농도계산은 측정을 통하여, 가스 그리고 액체부하를 변화시킴으로써 측정범위를 파악하였다. 실험 결과, MEA의 경우 흡수액 농도, 유입 CO2 농도가 높을수록 빠른 파과시간을 가짐을 알 수 있었고, MEA 10%, DEA 10%, AMP 10% 농도에서의 흡수속도는 MEA, DEA, AMP의 순으로 나타났으며, 흡수부하는 AMP, DEA, MEA의 순으로 나타났다. 그리고 흡수액의 모든 혼합비 및 온도 조건에서 MEA의 첨가량이 높아질수록 CO2의 흡수효율이 감소하는 것으로 나타났다. 이러한 실험결과를 바탕으로 혐기성 소화조에 적용할 CO2 흡수 충전탑 내의 흡수액은 MEA을 적용할 경우 가장 높은 효율을 가지는 것으로 판단되었다.