        This study researched problems of safety inspection method and current legislative system for the structure safety evaluation of Rahmen structure affected by remodeling. The elements of weight increase were examined in terms of differences of load moment, shear force, compressive stress and amount of steel before and after remodeling by structure analysis. The thorough examination for impacts of weight increase is indispensable to change of use or extension.
        4,300원
        42.
        2019.05 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 노후화된 공동주택 수직 증축 리모델링 시 면진시스템의 적용성을 검토 및 면진시스템 적용을 위한 기초자료를 제공할 목적으로 동일한 구조로 수직 증축 시 수직 층수와 면진주기에 따른 최적 면진주기를 산정하였다. 해석결과, 3개층 수직 증축 시에는 면진주기를 비면진 건물 주기의 2배 이상, 2개층 수직 증축 시에는 비면진 건물 주기의 3배 이상을 확보하여야만 충분한 면진효과를 나타내는 것을 알 수 있었다. 또한, 1개층 수직 증축 시에는 비면진 건물 주기의 4배 이상을 확보하여야만 면진효과를 나타내었다. 위의 결과를 활용하여 3개층 수직증축 리모델링 대상 공동주택에 면진시스템을 적용하여 그 효과를 검증하였다. 최상층 최대응답가속도가 비면진 건물의 최대응답가속도 보다 X방향의 경우에는 약 70%로, Y방향의 경우에는 약 65%의 감소를 나타내었다. 또한, 밑면 전단력의 경우, 비면진 건물과 비교하여 X방향 및 Y방향 모두 약 30% 감소하는 것으로 나타났다.
        43.
        2018.05 KCI 등재 서비스 종료(열람 제한)
        주택법에 근거하여 철근콘크리트 공동주택의 리모델링 시 최대 3개층의 수직증축 및 기존 세대수의 15%까지 증축이 가능하게 되 었다. 수직증축 리모델링 가능 여부는 안전진단 기준 및 매뉴얼을 바탕으로 기울기 및 침하, 내하력, 내구성 평가 부문에 대한 조사를 통하여 평가하고 판정하도록 되어 있다. 그러나 현행 증축형 리모델링 안전진단 기준 및 매뉴얼은 재건축 안전진단 기준과 비교하여 조사대상표본 수를 증대시키는 등 보수적인 것으로 평가되고 있으며, 특히 내구성 평가 부문에 검토 및 개선이 필요한 것으로 생각된다. 따라서 본 연구에서는 수도권 지역 공동주택의 증축형 리모델링 안전진단 조사 사례에 대한 내구성 조사 항목 중 콘크리트 탄산화를 대상으로 통계적인 수법에 의해 표본 수 합리화 방안을 제시하였다.
        44.
        2018.04 서비스 종료(열람 제한)
        The 'Housing Act (‘14.04), which permits the remodeling of old apartment buildings, has been implemented. In particular, vertical remodeling is generally implemented by adding 2~3 floors above the top floor of existing apartments. Technically, it is necessary to reinforce the existing pile due to the increase of vertical, horizontal, seismic load, etc. However, the existing piles are loaded simultaneously and so each pile was constructed at limited base space for application of reinforcement method. The bearing capacity of existing piles decreases due to vertical expansion so the bearing capacity of the piles must be confirmed by the indirect method(laboratory test etc.) in the first safety diagnosis and by the direct method(field test etc.) in the second safety diagnosis.
        45.
        2017.09 서비스 종료(열람 제한)
        Most of the apartment buildings to be remodeled are in the form of wall structures, and walls are very important structural members. When remodeling, there are cases where existing walls are demolished and new walls are installed. If a wall is newly installed, the continuity of the wall from the foundation to the top floor must be ensured. Some slabs prevents the vertical continuity of the reinforced wall. It is because the upper and lower wall reinforcing bars must be connected through the demolished slab and the concrete must be poured. Therefore, in this study, the method to secure the vertical continuity of the reinforced wall during the remodeling will be examined.
        46.
        2017.04 서비스 종료(열람 제한)
        University facilities have became aged building because their average was more than 30 years old. The physical condition of the university facility is significantly correlated with student academic performance and outcome. Thus, green remodeling is crucial which improves energy performances of university facilities and student outcome. This study analyzes the case of 'H university'. Target of case study applies Green-Remodeling in old university facility for performance improvement. Goal of this study is suggestion for strategies to successfully apply Green-Remodeling to a university facility. This study draws a conclusion from risk analysis of the target case.
        47.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        University facilities have became aged building because their average was more than 30 years old. The physical condition of the university facility is significantly correlated with student academic performance and outcome. Thus, green remodeling is crucial which improves energy performances of university facilities and student outcome. This study analyzes the case of 'H university'. Target of case study applies Green-Remodeling in old university facility for performance improvement. Goal of this study is suggestion for strategies to successfully apply Green-Remodeling to a university facility. This study draws a conclusion from risk analysis of the target case.
        50.
        2016.04 서비스 종료(열람 제한)
        Standard reinforcing technology of remodeling will be established through the actual remolding cases. Reinforcement techniques can be classified as a technique of seismic retrofit technologies, vertical and horizontal expansion joint detail, footing reinforcing technology, and general repair method.
        51.
        2016.04 서비스 종료(열람 제한)
        In this study, existing wall-type apartment in 1990s is evaluated by KBC2009. Based on structural calculation, seismic performance evaluation is performed with dynamic nonlinear analysis. After that, this building is extended up to three stories in vertical direction. In this study, the seismic performance evaluation results of wall-type apartment can be used in performance-based design of the vertical extension remodeling.
        52.
        2016.04 서비스 종료(열람 제한)
        The recent revision of Housing Act allow vertical extension up to maximum 3 stories and increase the ratio of floor area to site up to 15%. Currently, the feasibility of performing vertical extension is evaluated based on safety diagnosis provisions and manuals for vertical extension with preliminary investigations on slope, deflection, load-bearing capacity, and durability. However, a need for more reasonable evaluation methodology for the preliminary investigation is still required because the current procedures are borrowed from safety diagnosis provisions and manuals for reconstruction without detailed examinations on evaluation criteria and sampling methods. Accordingly, this study is intended to suggest a method to obtain feasible sampling numbers for durability assessment by analyzing field data on concrete carbonation, chloride content, and steel corrosion. The results of this study are expected to be beneficial for establishing more reasonable field sampling number, and in turn, more reliable durability assessment protocol for vertical extension.
        53.
        2015.10 서비스 종료(열람 제한)
        In the recent remodeling construction for old apartment, it is general to extend the parking space for the increased cars for residents. This paper reviews the extension methods of parking space and presents the problems that must be solved for the construction. In this paper, three extension cases of parking space in the remodeling projects were reviewed. As a result, the demand for the extension needs to be analyzed for the various cases and the technologies for the best-fitted construction should be suggested based on the demand.
        54.
        2014.12 KCI 등재 서비스 종료(열람 제한)
        In terms of both quality of rural lifestyle and cultural awareness, the importance of community facility is being emphasized. Nevertheless, by occasion of graying, population outflow and revenue loss, rural society faces the erosion of community. For these reasons, government is promotion an community space construction project on rural areas which is lack of community facilities. Whereas the projects are just one off thing not include upkeeping, so lots of functional overlapping community facilities are formed in same place. In this study has classified rural community facility remodeling element and designed rural community facility evaluation system of each elements. In order to implement of purpose, it has categorized community remodeling index in rural area by literature analysis and site survey. For setting remodeling rating system, this study analysed preceding research data and conducted a Delphi survey of 30 experts. As a result, this study deducted 29 categories of community remodeling index and 21 categorizes of remodeling rating clause. Taking this result, this study progressed case study on seonheul-ri in Jeju. Implications, limitations and future research directions are presented. It would be groundwork for remodeling system development in rural community facility.
        56.
        2014.10 서비스 종료(열람 제한)
        In the remodeling underpinning, Connection between pile and footing is very important considering load transfer aspect. In this paper, the 3type construction cases of connection is introduced.
        57.
        2014.10 서비스 종료(열람 제한)
        In this paper, we determine the number of reinforced pile foundations required for vertical extension remodeling through analysis of construction steps on all combinations of load including the seismic load and vertical load.
        58.
        2014.04 서비스 종료(열람 제한)
        In this paper, construction staged-analysis is introduced to understand how the additional loads transfer to existing and added piles. Added piles are not able to take on the existing load due to mechanical problem.
        59.
        2014.04 서비스 종료(열람 제한)
        Based on the study of chloride migration coefficient and hydration heat evolution, it was found that the use of ternary blended cement was effective to achieve desired service life and minimum crack index. On the other hand, a high level of compressive strength is required for marine concrete mix design.
        60.
        2014.04 서비스 종료(열람 제한)
        On this study, carbonation rate and W/C ratio were estimated by collecting actual data of each carbonation depth and compression strength from inner wall, outer wall, stair hall, and balcony floor of certain remodeling apartments. Through above tests, this study can be reference data of the method of life time prediction for the apartments that subject to remodeling.