        21.
        2015.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Although disinfection in drinking water treatment plants provides a safer water supply by inactivating pathogenic microorganisms, harmful disinfection by-products may be formed. In this study, the disinfectant, chlorine, was produced on-site from the electrolysis of salt (NaCl), and the by-products of the disinfection process, bromate and chlorate, were analyzed. The provisional guideline levels for bromate and chlorate in drinking water are 10 μg/L and 700 μg/L, in Korea, respectively. Bromide salt was detected at concentrations ranging from 6.0 ~ 622 mg/kg. Bromate and chlorate were detected at concentrations ranging from non-detect (ND) ~ 45.3mg/L and 40.5 ~ 1,202 mg/L, respectively. When comparing the bromide concentration in the salt to the bromate concentration in the chlorine produced by salt electrolysis, the correlation of bromide to bromate concentration was 0.870 (active chlorine concentration from on-site production: 0.6–0.8%, n=40). The correlation of bromate concentration in the chlorine produced to that in the treated water was 0.866.
        4,000원
        22.
        2015.05 구독 인증기관·개인회원 무료
        국내 정수장 노후화의 가속과 더불어 신규 위험물질 및 미량유해물질에 대한 안전성 확보를 위하여 정수장의 고도화를 위한 노력이 지속되고 있으며, 막여과 기반의 고도정수처리 공정의 도입이 안전성 확보의 대안으로 자리잡고 있다. 그러나 원수의 특성을 고려한 막여과공정의 구성방안 및 운영방안 마련이 필요한 실정이다. 본 연구는 원수내 망간의 계절적 발현 특징을 나타내는 U정수장을 대상으로 500m³/일 용량의 정밀막여과를 기반으로 한 고도정수처리 테스트베드를 구축하고, 원수의 수질특성을 고려한 운영인자 확립과 더불어 처리효율을 평가하였다.
        23.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Membrane backwashing waste shows seasonally different characteristics and it has bad settleability differently from general backwashing waste in water treatment plant. When chemicals was injected to membrane backwashing waste, the settleability was better than chemicals was not injected. However, when settled lower sludge was not discharged, flowing sludge continuously was concentrated over a certain surface and floatation penomena occurred according to flowing velocity. When the lower sludge was discharged continuously in the thickener to prevent floatation penomena of turbidity materials, the depth of sludge surface was the least and the settleability increased.
        4,200원
        24.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 국내 최초로 도입된 Y 정수장의 세라믹막 고도정수처리를 위한 최적 운영 인자를 도출하기 위하여 수행되었다. 경제성과 수질조건을 만족하면서도 세라믹막 여과성능을 지속⋅유지할 수 있는 최적 운영조건을 도출한 결과, Y 정수장의 평상시 수질 조건에서 막역세척으로 인한 배출수 발생량을 최소화시키면서도 막여과성능을 유지할 수 있는 최적 여과지속시간(역세척 주기)은 시설용량(16,000 m3/일) 기준 시 4.0시간으로 조사되었다. 또한 화학세척(CIP)에 따른 막차압 회복력을 조사한 결과, 구연산을 이용한 산세정을 통하여 철, 망간, 알루미늄 등의 막 파울링을 일으키는 무기오염물질은 제거되지만 막 회복률은 낮았다. 반면 차아염소산나트륨을 사용한 알칼리 세정을 통해서는 막 운영 초기 막차압으로 회복되는 것으로 나타났다. 막차압을 발생시키는 파울링 주요 원인물질은 친수성 고분자 유기오염물인 polysaccharides로 조사되었으며, 화학세척(CIP)시 막성능 회복률은 세척약품 온도에 의한 영향이 매우 크며, 온도가 높은수록 막성능 회복률이 향상되는 것으로 조사되었다.
        4,300원
        25.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        So many drinking water treatment plants are under various difficulties by new reinforced effluent standards. Since the target turbidity, much higher than annual average, for designing sludge thickener have to be set to confront high turbidity season, the sludge at thickener should be put up for a long time during usual days. So the soluble manganese and chloroform may be formed under the anaerobic environment in the sludge thickener when the sludge retention time is longer with low turbidity. This phenomenon results in difficulties to keep regulatory level of the discharged effluent. For an effort to overcome the problems, a sludge aeration was successfully implemented into the thickening process. As a result, the final effluent quality and sludge volume were much improved; 41 % of manganese, 62 % of chloroform and 35 % of sludge volume. Additionally, effluent quality was improved ; 61 % of Manganese on aeration with pH control and we could make sure of stability effluent quality despite a long sludge retention time. We recommended the standard of installation sludge aeration equipment to nationally supply water treatment plant under effluent water quality problem ; Manganese, Chloroform, etc.
        4,000원
        26.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Various treatment system for residuals have applied to save water resources, but most of them were not be satisfied with legal standard consistently. In this study, submerged membrane treatment system was operated to treat water treatment plant residuals and operation parameters was evaluated. Result of this experiment, high concentration organic matters contributed to high increase Transmembrane pressure(TMP) of membrane system(from 0.05 bar to 0.35 bar). And backwash process was effective to stabilize membrane system operation. After Cleaning-In-Place(CIP), permeability was recovered about 100 % from first operation condition. Inorganic matters (Fe, Mn, Al, Ca, Mg) were not effective membrane filtration performance. The quality of residual treatment was satisfied with drinking water quality standard and a treated water from that system was suitable for water reuse.
        4,500원
        27.
        2010.02 구독 인증기관 무료, 개인회원 유료
        In this study, the performance of powdered activated carbon(PAC) contactor located in the Hakya water treatment plant(WTP) was evaluated. The result of tracer tests showed that the plug flow portion was more than 70 %. According to the total organic carbon(TOC) data of target WTP, there were no clear evidence that the addition of PAC contributed to the removal of organics. However, the results of jar test, conducted with the raw water taken from the Hakya WTP, proved that PAC could remove dissolved organic carbon(DOC) to some extent when the proper velocity gradient was maintained. It was estimated that the production rate of Hakya WTP, defined as the ratio of the operating flow rate to the design flow rate, was only 50 %. Because of this lower production rate, the mixing intensity in the contactor is much less than the designed value and, finally, the performance of PAC contactor was much less than what was expected.
        4,000원
        28.
        2006.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        정수장 슬러지는 수 처리 역 세척 과정에서 발생되는데, 기계적인 방법 또는 자연건조방법으로 탈수된 후 주로 해양투기, 매립등의 방법으로 처리한다. 최근에는 런던협약에 의해 해양투기가 상당히 제약을 받고 있다. 탈수된 정수장 슬러지를 위생매립장의 복토재로서의 활용가능성을 파악하기 위하여 실내실험을 통하여 정수장슬러지의 물리 화학적 특성과 지반공학적 특성을 파악하였다. 슬러지의 지반공학적 특성을 향상시키기 위하여 슬러지에 일반토사를 혼합한 시료에 비중계실험, 액 소성한계실험 비중실험, 다짐실험. 일축압측 실험등을 실시하였다. 슬러지에 일반토사를 혼합한 혼합토는 정수장슬러지와 비교하여 최대건조단위증량은 증가하고, 최적함수비는 감소하였고, 최대압축응력과 마찰각을 증가한 반면 점착력은 감소하였다. 미국환경청의 복토재 기준을 확보하기 위해서 슬러지와 일반토사를 3:7로 혼합하여야 하며, 혼합토의 압축강도는 3.6kg/cm2이다.
        4,000원
        29.
        2006.02 구독 인증기관 무료, 개인회원 유료
        Analysis of design parameters of residual treatment process at eight model water treatment plants, which were located in the four major watersheds, showed that there were large differences between those design parameters and the actual conditions. In this background, a new procedure was proposed and applied to the Chungju water treatment plant as an example of the optimum design of residual treatment process based on the characteristics of raw water. In this design example, a filter backwash recycle system consisting of a surging tank and sedimentation basin was newly proposed for more safe recycle of spent backwash water. It is expected that the design procedure proposed in this study would be estimated as a meaningful attempt to develope new design procedure for the domestic water industry.
        5,400원
        31.
        2002.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The contamination problem is getting worse now a day because of the industrial activities. Recently it has been announced that there's environmental hormone in river and lake which produces clean water, also there's too many of algae reproduces under the water and some virus in the drinking water. The quality of water is very important. pure and clean water is not only a precondition for human being to live but a basic factor to improve the quality of life. so a water purification system must be developed. This study is about the surface washing treatment technique. We tried to use a rotary nozzle to get a tush degree of efficiency, for it was not enough with present way of washing. The nozzle is run by water pressure. The results of the experiment are as follows. We got a clean and equal surface after washing. After washing, the water's maximum consistency was 330NTU and it shows that this way is better than before one with 215NTU. Clean level of the filter was 6˚and it's 2.8 times higher than 17˚with the old way. We can see the results that the new way of washing is more effective than old way based on this study.
        4,200원
        33.
        1999.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to recover the aluminum from water treatment plant sludge containing alumina. The optimum reaction conditions about chlorination of sludge with NH4Cl are as follows: the weight ratio of sludge to NH4Cl is 4, the reaction time is 60min, and the temperature is 300℃. And the result of leaching time test showed that the highest yield of alumina at 160℃ was 96% but the result of leaching test at 160℃ was little better than that of leaching test at 100℃ while the leaching concentration of HCl was 4N. The optimum reaction conditions of chlorinated sludge with NH4Cl, gave the highest yield of 95.41% based on aluminum.
        4,000원
        34.
        1995.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Today a conventional water treatment system has many problems. The ozone/GAC process, sometimes termed Biological Activated Carbon(BAC), appeared to be effective for the removal of soluble organic matters in the drinking water. The water quality of Nak-dong river in Pusan, generally shows BDOC 30-40% and NBDOC 60-70%. The pilot plant installed at the Duk-san water works that was been largest treatability(1,650,000ton/day) in Pusan. A experimental water in the pilot plant made use of the water after sand-filteration. Following results are drawn from this study. Initial adsorption velocity($DOC/DOC_o/T$) in the pure adsorption of GAG had a 0.0225, it's velocity changed to 0.006 after ozone added and the optimum ozone dose ranged of $1.4-2.0mgO_3/L$. A experimental water in the pilot plant composed with humic material(78%). Humic material composed with humic acid(20%) and fulvic acid(56%), and it's rate changed to 18 and 50% respectively after ozone added. DOC constantly decreased in the EBCTs and removal efficieny in the 15min of EBCT was 45-50%. It showed the largest removal rate of BDOC in the EBCT 5 and among the season, characteristics of removal varied. The HPC distributed over $10^6-10^7CFU/cm^3$ in the bed depth and among the season, distribution of HPC were differential.
        4,200원
        35.
        1994.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To slove the problems by the scum, which causes operational and water quality problems in water treatment plants, several researches were conducted based on the site investigations on twelve large water treatment plants, biological and chemical analysis of scum, analyzing raw water quality data. Two types of scum, which are from scum and floe scum, can be classified based on the analysis and site investigations. The major parameter generating floe scum was indicated as fine bubbles dissolved in the water. The fine bubbles dissolved in the water can be generated by over-saturated air in the water, adding aluminum surface as the coagulant, conducting the break point pre-chlorination and so on. The water spray method, which is one of the physical treatment methods for removing scum, was selected for conducting experiments on the removal efficiency in the flocculation basin of the real water treatment plant. The water spray method was successfully applied for removing scum with the advantages of using spiral nozzles in case of using the raw water rather than the cleaned water.
        4,000원
        36.
        1994.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this paper, the unit processes in the typical water treatment plant, which need to be expanded because the water demand is over the existing water treatment capacity in the near future, were carefully examined to upgrade the water treatment plant. The models were installed in the fields as a distorted model based upon the hydraulic similitudes. The models having the constant discharge ratio in the unit processes between the model and the prototype were installed as two units to compare the treatment efficiencies. The capacity of the individual unit, which is a model of the prototype of $250,000m^3/day$ capacity, was $24m^3/day$. In the mixing and flocculation experiments, the mixing intensity of flocculators G was selected as the main experimental item. The optimal mixing intensities G, which are 65/sec for experimental discharge of $1m^3/hr$ and 85/sec for experimental discharge of $1.3m^3/hr$, are identified based upon the comparison the relative turbidity removal efficiencies. Also, the outlet weir loading was selected as the main experimental item in the sedimentation process. Through the continuous experiments with the main experimental items of the mixing intensity of flocculators G and the outlet loading of the weir in the sedimentation basin, about 20% upgrading compared to the existing water treatment capacity was obtained.
        4,000원
        38.
        2016.07 KCI 등재 서비스 종료(열람 제한)
        The H water treatment plant has been operating since 1982 and has had no renovation. It is assumed that the filters have been operated for more than 30 years and therefore are deteriorated. Many of the filters show an unequal state of air scouring during backwashing. For this study one filter, which was presumed most deteriorated among eighteen filters, was selected as a model filter for renovation. Some of the effects seen after renovation of the underdrain system were a lower average filtrated turbidity by approximately 0.02 NTU and an equal backwash state throughout the filter bed. Sand wash efficiencies by backwash before renovation of the underdrain system were 28%, 8%, and 5% at the surface, 50 cm depth, and 100 cm depth, respectively, and after renovation of the underdrain system were 94%, 26%, and 15% , respectively. The standard deviation of the effective sand size was 0.025-0.033 mm before renovation of the underdrain system and 0.002-0.011 mm after renovation of the underdrain system, meanings there was equal backwash pressure throughout the filter. Filtration time after renovation was approximately 2 times longer than before renovation.