        61.
        2019.04 서비스 종료(열람 제한)
        In this study, flexural test of the 2-span arch deck specimen was conducted. In load-displacement test , a load carrying capacity of the specimen was approximately 2.4 times higher than the design ultimate load. Strain of Rebars was structurally stable until the maximum load was reached. The overall results showed that the specimens had excellent structural performance due to the structural advantages of the arch shape. Overall, the precasted arch deck is expected to be useful for long span PSC girder bridges as wide span decks..
        62.
        2019.04 서비스 종료(열람 제한)
        The flexural strength of lightweight aggregate concrete (LWAC) T-beams reinforced with the minimum amount of longitudinal reinforcement could be conservatively predicted by the conventional procedure using the equivalent stress block specified in concrete code provision.
        63.
        2019.04 서비스 종료(열람 제한)
        In this study, the bending performance of flexural specimens fabricated with ECC was compared with typical reinforced concrete specimens. Test results show that the deflection of specimens made of ECC is increased compared with that of normal concrete specimens, and ductile fracture behavior is shown.
        64.
        2019.04 서비스 종료(열람 제한)
        In this paper, the flexural behavior of RC member recycled heavy weight waste glass as fine aggregate was evaluated by finite element analysis. From the results, the analytical results do not reflect the experimental results. This is because the stress-strain curve of the concrete specimen obtained from the compression test was used as the input data for the ABAQUS. Therefore, the ABAQUS, based on the experimental results of the stress-strain relationship of concrete, predicted the load-displacement relationship without considering the reduction in load capacity.
        65.
        2018.10 서비스 종료(열람 제한)
        In this paper, the flexural behaviors with substitution ratio of heavyweight waste glass are compared and evaluated in reinforced concrete members. From the results, when the heavyweight waste glass was used as the fine aggregate, the yielding load (Py) and maximum load (Pu) were less affected. However, the load capacity of the RC member was gradually reduced on the large deformed stage when all of the fine aggregate was replaced by heavyweight waste glass.
        66.
        2018.10 서비스 종료(열람 제한)
        This paper evaluates analytically the flexural behavior of steel fiber reinforced concrete (SFRC) notched beams according to the tensile strength of steel fiber. For this purpose, compressive strength and bending tests of SFRC applying steel fibers with tensil strength of 1,200 and 1,600 MPa was conducted. Strain hardening behavior was observed when using high tensile strength steel fiber. Compression and tensile models were established through test results. For the tensile model, hordijk model and trilinear model were analyzed and compared. The results of analysis showed good agreement when using trilinear model.
        67.
        2018.07 KCI 등재 서비스 종료(열람 제한)
        본 연구는 순환골재를 사용한 콘크리트의 활용증대 방안으로 철근콘크리트 구조물의 노후화와 내구성 저하 시 보수․보강으로 사용되는 FRP (AFRP, CFRP) 판으로 보강된 순환골재 고강도콘크리트(40MPa, 60MPa) 보를 제작하여 순환골재 철근콘크리트 보의 휨 보강에 대한 적용성을 평가하고자 한다 기존의 표면매입보강에 따른 에폭시와 FRP 판의 부착력을 고려하지 않기 위해 콘크리트 타설 전 FRP 보강판을 거푸집에 미리 설치하였으며, 순환골재 치환율(30%), 콘크리트 강도(40MPa, 60MPa), 이형철근(D10, D13), FRP 판의 종류(AFRP 판, CFRP 판)를 변수로 12개 실험체를 제작하여, FRP 판과 순환골재 치환율에 따른 휨 성능을 분석하였다. 그 결과 FRP 판으로 보강한 실험체는 무보강 실험체에 비해 최대 17% 증가하는 경향을 나타내었으며 AFRP 판에 비해 CFRP 판의 보강 성능이 우수한 것으로 나타났다. 또한 순환골재 치환율에 따른 보강 성능의 차이는 없는 것으로 나타났다. 실험에 의해 측정된 균열모멘트는 파괴계수를 이용한 결과 기준식과 비슷한 값을 나타났으며 휨 모멘트는 FRP 판을 보강한 일부 시험체가 KCI 2012와 ACI 440-2R에서 제시한 기준을 만족하지 못하는 것으로 나타났다.
        68.
        2018.05 KCI 등재 서비스 종료(열람 제한)
        표면매립공법으로 매립한 철계-형상기억합금으로 보강한 보의 휨 거동을 장기 하중 재하실험을 통해 평가하였다. 철계-형상기억 합금 길이대비 2%와 4%의 사전변형 및 형상기억효과 활성화에 의한 프리스트레스 하중 도입을 실험변수로 설정하였다. 1 tonf의 콘크리트 추를 보 중앙에 거치한 후 6개월간의 보 중앙부의 장기 처짐을 측정하였다. 실험결과, 철계-형상기억합금으로 보강한 보의 휨 강성이 증대되었으며, 사전변형이 증가할수록 보강재의 강성감소로 인한 처짐이 증가하는 것으로 나타났다. 프리스트레스 하중 도입에 따른 처짐을 비교했을 때, 프리스트레스 하중을 도입하지 않은 실험체에 비해, 프리스트레스 하중을 도입한 실험체는 약 30%의 처짐 감소 효과를 보이는 것으로 나타났다.
        69.
        2018.04 서비스 종료(열람 제한)
        The flexural behavior of ECC according to the tensile strain capacity was analytically estimated with the layered section method. Moment-curvature curve was first obtained, then load-deflection relation was calculated. The analytical result indicated that there was noticeable increase in deflection at peak load with the higher tensile strain capacity within 3.0%, and it was found that more than 3% strain capacity did not provide higher deflection but helped improve the load resistance.
        70.
        2018.04 서비스 종료(열람 제한)
        In this study, sodium chloride is directly mixed with binders in order to simulate harsh environments by promoting the corrosions of fibers and cement-based matrix including UHPC (Ultra High Performance Concrete). The experimental variables are the amount of sodium chloride and material composition such as UHPC, high strength mortar, and normal mortar. The experimental results show that UHPC has the superior capability to resist chloride ions due to its dense microstructures.
        71.
        2018.04 서비스 종료(열람 제한)
        Recently, concrete-steel hybrid girder is being developed to improve economic efficiency and durability. To evaluate flexural behavior of the proposed girders, 17.0m full-scale joint was fabricated and tested under vertical loading. The study was examined vertical displacement; the strain of the reinforcement; and the crack patterns in the concrete. The proposed girders was analyzed to be safe in all members.
        72.
        2018.03 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 중공형의 PHC말뚝과 강관말뚝을 합성한 중공형 콘크리트 충전 강관(HCFT)말뚝의 거동분석을 위한 수치해석 모델을 개발하였고 휨강도시험에 적용하여 모델의 타당성을 검증하였다. 개발된 비선형 유한요소해석 모델의 적정성을 파악하기 위해 실물 시험결과와 비교하였고 이를 활용하여 HCFT말뚝에 적합한 접촉조건, PC강봉의 제원에 따른 효과, 콘크리트 두께에 따른 효과 등을 분석하였다. 소성응력분배법을 적용하여 HCFT말뚝의 휨강도 산정식을 제안하였고 시험 및 해석결과와 비교하여 활용성을 검증하였다. 본 연구의 결과는 HCFT말뚝의 최적설계 및 거동분석에 기초자료로 활용될 수 있을 것으로 판단된다.
        74.
        2018.03 KCI 등재 서비스 종료(열람 제한)
        본 논문은 SIFCON으로 제작된 휨부재의 휨거동에 대한 실험적·해석적 연구결과를 제시한다. 우선, 12개의 SIFCON 보에 대한 휨실험을 실시하고 휨거동을 평가하였다. 실험변수로는 강섬유 종류, 인장철근 유·무, 단면의 높이를 고려하였다. Type-A 강섬유보다 뽐힘저항성이 우수한 Type-B 강섬유를 사용한 시험체는 전단파괴가 발생하지 않고 휨파괴 거동을 보였으며, 강섬유 형상비는 인장철근을 사용하지 않는 SIFCON 보의 거동에 큰 영향을 주었으나 인장철근을 갖는 SIFCON 보의 거동에 대해서는 그 영향이 매우 미미하게 나타났다. 추가적으로 본연구에서는 SIFCON에 대한 휨강도 예측식을 제시하였다. 휨강도 예측값에 대한 실험값의 비의 평균과 표준편차가 각각 1.02와 0.04로 나타나 휨강도 예측식은 SIFCON 보의 설계 및 성능 평가에 유용하게 사용될 수 있을 것으로 생각된다.
        75.
        2018.03 KCI 등재 서비스 종료(열람 제한)
        콘크리트는 장기수명이 요구되는 구조물에 적합한 건설재료로 내구성이 우수하지만 장기간 지하수에 노출되어 발생하는 칼슘용출 현상에 대한 이해 및 이에 따른 RC 부재의 휨 거동 특성을 평가할 필요가 있다. 실험결과에 따르면, 광물질 혼화재는 RC 부재의 장기강도 개선에 효과적이지만, 칼슘용출이 발생하면 RC 부재의 항복하중 및 휨 강성이 감소하고 중립축깊이와 처짐량이 증가하는 것으로 나타났다. 따라서 칼슘용출에 의한 열화는 RC 부재의 성능 저하를 유발하므로 칼슘용출 환경에 노출되는 지하구조물에 광물질 혼화재가 적용될 경우에는, 광물질 혼화재 종류에 따른 최적 혼입 비율이 마련되어야할 것으로 사료된다.
        77.
        2017.10 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 양생조건이 다른 압축강도 90 MPa 수준의 고강도 콘크리트 부재의 휨거동 실험을 수행하였다. 실험변수는 정상 및 저온 양생 조건, 인장 철근량 및 콘크리트 압축강도 수준 등을 고려하였다. 8개의 보 부재를 제작하여 휨 실험을 수행하였으며 균열 간격, 하중-처짐 관계, 하중-변형률 관계 및 연성지수를 파악하였다. 실험결과는 철근량이 증가함에 따라 균열 개수는 증가하고 균열간격은 감소하는 경향 을 나타내며, 콘크리트 강도가 높을수록 균열개수가 줄어들기는 하지만 그 효과는 철근량보다는 상당히 작은 것을 알 수 있었다. 설계기준에서 제안된 평균 균열 간격 식과 비교한 결과, 실험결과가 제안식의 결과보다 약간 크게 나타났으나, 제안식은 콘크리트 강도 및 양생조건을 반영 하지 못하는 문제점이 있다. 정상 양생된 부재들의 연성지수는 3.36~6.74이며, 저온 양생된 부재들의 연성지수는 1.51~2.82으로 나타나, 저온 양생된 부재들의 거동은 정상 양생된 부재들에 비해서 연성도지수가 저감됨을 확인하였으며, 본 연구와 기존 연구의 연성지수를 비교한 결과, 고강도 콘크리트 부재의 연성지수는 선행연구의 보통강도 콘크리트의 연성지수 보다 크게 나타났으나, 더 구체적인 결과를 파악하기 위해서 는 추가연구가 필요하다고 판단된다.
        78.
        2017.09 서비스 종료(열람 제한)
        In this study, We evaluated the flexural behavior of high performance fiber reinforced cementitious composite (HPFRCC) with single steel fibers. to do this, we considered different types of steel fibers such as hooked, twisted and straight fibers. Test results indicated the flexural performance tends to increase as the incorporation rate of steel fiber increases and when the length of the fiber is long and at the high volume fractions(vf of 2.0) the flexural high performance was reduced.
        79.
        2017.08 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 휨을 받는 압축강도 80 MPa 수준의 고강도 콘크리트 부재의 구조거동 실험 연구를 수행하였다. 실험변수는 보통(SD 400) 및 고강도(SD 600)철근, 0.98~1.58%의 종방향 철근비, 200×250, 200×300 mm의 단면크기를 고려하였다. 9개의 보 부재를 제작하여 휨 실 험을 수행하였으며 극한휨강도, 하중-처짐 관계, 균열 형태, 파괴형상 및 연성을 파악하였다. 실험결과는 철근비가 증가함에 따라 휨강도는 증 가하고 연성은 감소한다. 또한, 철근비가 증가함에 따라 균열의 개수가 증가하며 균열폭은 감소하는 경향을 나타내었다. 철근의 강도 등급에 따른 하중-균열폭 관계는 뚜렷한 차이를 나타내지 않는다. 콘크리트 비선형거동 해석을 수행하였으며, 극한하중 예측값과 측정값을 비교하였 다. 고강도 콘크리트의 휨거동 예측 결과는 실험부재의 휨강도를 전반적으로 과소평가하고 있다.
        80.
        2017.04 서비스 종료(열람 제한)
        This paper provides the flexural test results of steel fiber reinforced concrete (SFRC) prisms with different aspect ratios of steel fibers (60 and 67). All mixtures have specific compressive strength of 40 MPa and steel fiber volume fraction of 0.75%. According to ASTM C 1609 and EN-14651, SFRC prisms with 150×150×550 mm were made and tested under bending loading. Test results indicated that the aspect ratio of hooked-end steel fibers has insignificant effect on the first-cracking strength and flexural behavior of SFRC prisms.
        1 2 3 4 5