        검색결과 31

        1.
        2022.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The seismic behaviors of the arch structure vary according to the rise-span ratio of the arch structure. In this study, the rise-span ratio (H/L) of the example arch structure was set to 1/4, 1/6, and 1/8. And the installation angle of the seismic isolator was set to 15°, 30°, 45°, 60° and 90°. The installation angles of the seismic isolator were set by analyzing the horizontal and vertical reaction forces according to the rise-span ratio of the arch structure. Due to the geometrical and dynamic characteristics of the arch structure, the lower the rise-span ratio, the greater the horizontal reaction force of the static load, but the smaller the horizontal reaction force of the dynamic load. And if the seismic isolator is installed in the direction of the resultant force of the reaction forces caused by the seismic load, the horizontal seismic response becomes small. Also, as the installation angle of the seismic isolator increases, the hysteresis behavior of the seismic isolator shows a plastic behavior, and residual deformation appears even after the seismic load is removed. In the design of seismic isolators for seismic response control of large space structures such as arch structures, horizontal and vertical reaction forces should be considered.
        4,000원
        2.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to evaluate the earthquake safety of equipment in structures, it is essential to analyze the In-Structure Response Spectrum (ISRS). The ISRS has a peak value at the frequency corresponding to the structural vibration mode, but the frequency and amplitude at the peak can vary because of many uncertain parameters. There are several seismic design criteria for ISRS peak-broadening for fixed base structures. However, there are no suggested criteria for constructing the design ISRS of seismically isolated structures. The ISRS of isolated structures may change due to the major uncertainty parameter of the isolator, which is the shear stiffness of the isolator and the several uncertainty parameters caused by the nonlinear behavior of isolators. This study evaluated the effects on the ISRS due to the initial stiffness of the bi-linear curve of isolators and the variation of effective stiffness by the input ground motion intensity and intense motion duration. Analyzing a simplified structural model for isolated base structure confirmed that the ISRS at the frequency of structural mode was amplified and shifted. It was found that the uncertainty of the initial stiffness of isolators significantly affects the shape of ISRS. The variation caused by the intensity and duration of input ground motions was also evaluated. These results suggested several considerations for generating ISRS for seismically isolated structures.
        4,000원
        3.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        When an unexpected excessive seismic load is applied to the base isolation of arch structure, the seismic displacement of the base isolation may be very large beyond the limit displacement of base isolation. These excessive displacement of the base isolation causes a large displacement in the upper structure and large displacement of upper structure causes structural damage. Therefore, in order to limit the seismic displacement response of the base isolation, it is necessary to install an additional device such as an anti-uplift device to the base isolation. In this study, the installation direction of the base isolation and the control performance of the base isolation installed anti-uplift device were investigated. The installation direction of the base isolation of the arch structure is determined by considering the horizontal and vertical reaction forces of the arch structure. In addition, the separation distance of the anti-uplift device is determined in consideration of the design displacement of the base isolation and the displacement of the arch structure.
        4,000원
        4.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        If an excessive displacement occurs in the base isolation system, the structure will be damaged due to overturning of the upper structure. In this study, we analyze the behavior of base isolation by applying earthquake to base isolation with anti-uplift device. In the case of structures that generate horizontal reaction forces such as arch structures, horizontal reaction forces must be considered in the design of the base isolation and structural members. And anti-uplift device for preventing the excessive displacement of the base isolation system is needed.
        4,000원
        5.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In a previous paper, ambient vibration tests were conducted on a cable stayed bridge with resilient-friction base isolation systems (R-FBI) to extract the dynamic characteristics of the bridge and compare the results with a seismic analysis model. In this paper, a nonlinear seismic analysis model was established for analysis of the bridge to compare the difference in seismic responses between nonlinear time history analysis and multi-mode spectral analysis methods in the seismic design phase of cable supported bridges. Through these studies, it was confirmed that the seismic design procedures of the “Korean Highway Bridge Design Code (Limit State Design) for Cable Supported Bridges” is not suitable for cable supported bridges installed with R-FBI. Therefore, to reflect the actual dynamic characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure is proposed that applies the seismic analysis method differently depending on the seismic isolation effect of the R-FBI for each seismic performance level.
        4,000원
        6.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, a field bridge test was conducted to find the dynamic properties of cable supported bridges with resilient-friction base isolation systems (R-FBI). Various ambient vibration tests were performed to estimate dynamic properties of a test bridge using trucks in a non-transportation state before opening of the bridge and by ordinary traffic loadings about one year later after opening of the bridge. The dynamic properties found from the results of the tests were compared with an analysis model. From the result of the ambient vibration tests of the cable supported bridge with R-FBI, it was confirmed that the dynamic properties were sensitive to the stiffness of the R-FBI in the bridge, and the seismic analysis model of the test bridge using the effective stiffness of the R-FBI was insufficient for reflecting the dynamic behavior of the bridge. In the case of cable supported bridges, the seismic design must follow the “Korean Highway Bridge Design Code (Limit State Design) for Cable supported bridges.” Therefore, in order to reflect the actual behavior characteristics of the R-FBI installed on cable-supported bridges, an improved seismic design procedure should be proposed.
        4,200원
        7.
        2015.01 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The nuclear accident due to the recent earthquake in Japan has triggered awareness of the importance of safety with regard to nuclear power plants (NPPs). An earthquake is one of the most important parameters which governs the safety of NPPs among external events. Application of a base isolation system for NPPs can reduce the risk for earthquakes. At present, a soil-structure interaction (SSI) analysis is essential in the seismic design of NPPs in consideration of the ground structure interaction. In the seismic analysis of the base-isolated NPP, it is restrictive to consider the nonlinear properties of seismic isolation devices due to the linear analysis of the SSI analysis programs, such as SASSI. Thus, in this study, SSI analyses are performed using an iterative approach considering the material nonlinearity of the isolators. By performing the SSI analysis using an iterative approach, the nonlinear properties of isolators can be considered. The difference between the SSI analysis results without iteration and SSI with iteration using SASSI is noticeable. The results of the SSI analysis using an effective linear (non-iterative) approach underestimate the spectral acceleration because the effective linear model cannot consider the nonlinear properties of isolators. The results of the SSI analysis show that the horizontal response of the base-isolated NPP is significantly reduced.
        4,000원
        8.
        2014.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        There has been an increasing demand for introducing a base isolation system to secure the seismic safety of a nuclear power plant. However, the design criteria and the safety assessment methodology of a base isolated nuclear facility are still being developed. A performance based design concept for the base isolation system needs to be added to the general seismic design procedures. For the base isolation system, the displacement responses of isolators excited by the extended design basis earthquake are important as well as the design displacement. The possible displacement response by the extended design basis earthquake should be limited less than the failure displacement of the isolator. The failure of isolators were investigated by an experimental test to define the ultimate strain level of rubber bearings. The uncertainty analysis, considering the variations of the mechanical properties of isolators and input ground motions, was performed to estimate the probabilistic distribution of the isolator displacement. The relationship of the displacement response by each ground motion level was compared in view of a period elongation and a reduction of damping. Finally, several examples of isolator parameters are calculated and the considerations for an acceptable isolation design is discussed.
        4,000원
        9.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 고정기초, 기초면진, 및 최상층에 TMD가 설치된 기초면진 구조물에 풍하중이 작용하는 경우에 구조물의 동적 거동을 해석하는 프로그램을 개발하여 면진장치가 풍하중이 작용하는 구조물의 동적거동에 미치는 영향을 파악하고자 한다. 난기류 스펙트럼을 이용하여 구조물에 작용하는 바람을 실제와 유사하도록 생성한 풍하중을 해석에 적용한다. 기초면진 장치가 구조물의 동적 거동에 미치는 영향을 분석하고, 풍하중이 작용하는 경우 기초면진이 설치된 구조물에서 TMD의 동적 제어 효과에 대하여 분석하고자 한다.
        4,000원
        10.
        2013.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Structures in a nuclear power system are designed to be elastic even under an earthquake excitation. However a structural component such as an isolator shows inelastic behavior inherently. For the seismic assessment of nonlinear structures, response history analysis should be performed. In this study, the response of base isolation system was analyzed by response history analysis for the seismic performance assessment. Firstly, several seismic assessment criteria for a nuclear power plant structure were reviewed for the nonlinear response history analysis. Based on these criteria, the spectrum matched ground motion generation method modifying a seed earthquake ground motion time history was adjusted. Using these spectrum matched accelerograms, the distribution of displacement responses of the simplified base isolation system was evaluated. The resulting seismic responses excited by the modified ground motion time histories and the synthesized time history generated by stochastic approach were compared. And the response analysis of the base isolation system considering the different intensities in each orthogonal direction was performed.
        4,000원
        11.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        정밀한 공정을 요구하는 반도체 및 TFT-LCD와 같은 첨단 기술산업 공장의 미진동 문제는 제품의 성능에 영향을 주는 주요한 인자로서 정밀기기 및 부품의 제조공정에 있어서 중요시 되어왔다. 본 논문에서는 이러한 첨단시설물의 미진동 문제를 해결하기 위하여 기초면진시스템의 미진동제어성능을 검토하였다. 이를 위하여, 기차에서 유발되는 인공지반운동을 생성하여 시간이력해석을 수행하였고 3층 예제구조물을 사용하였다. 수치해석을 통하여 수동 기초면진 및 스마트 면진시스템의 미진동제어성능을 고정기초구조물과 비교하였다. 그 결과 스마트 면진시스템이 미진동제어에 있어서 우수한 제어성능을 나타내는 것을 확인하였다.
        4,000원
        12.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        현재까지 스마트 면진시스템은 일본이냐 미국 같은 강진지역에서 개발되고 적용되어 왔다. 이렇게 강진지역에 있는 건축물을 지진하중으로부터 보호하기 위하여 개발된 스마트 면진시스템은 우리니라와 같은 중약진 지역에 있는 건축물에 그대로 적용되기에는 많은 한계점이 있다. 따라서 본 연구에서는 강진지역에 건설되는 건축물을 위한 스마트 면진시스템을 중약진 지역에 건설되는 건축물에 작용하였을 때 발생하는 문제점음 검토해보았다. 이를 위하여 예제구조물로 대공간 아치구조물을 선택하였고 스마트 면전시스템은 MR 감쇠기와 저감쇠 탄성베어링을 사용하여 구성하였다. 강진지역과 중약진 지역에서 발생하는 지진하중으로는 기존에 발생한 역사지진을 바탕으로 인공지진을 생성하였다. 수치해석결과 강진지역에 건설되는 대공간구조물을 위하여 개발된 스마트 면진시스템을 그대로 중약진 지역에 적용하면 면진효과가 상당히 줄어들므로 스마트 제어장지의 용량이 중약진 지역에 맞추어 주의 깊게 설계되어야 함을 알 수 있었다.
        4,200원
        13.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 지진하중을 받는 대공간구조물의 동적응답을 저감시키기 위하여 스마트 면전시스템을 제안하였다. MR 감쇠기와 저감쇠 탄성베어링을 사용하여 스마트 면진시스템을 구성하였으며 최적설계된 LRB 면진시스템과 비교하여 진동 제어성능을 검토하였다. 스마트 면진시스템은 제어알고리즘에 따라서 제어성능이 크게 좌우된다. 본 연구에서는 스마트 면진시스템이 설치된 대공간 구조물을 효과적으로 제어하기 위하여 퍼지제어기를 사용하였다. 면전시스템이 적용된 대공간 구조물의 동적응답과 면진층 변위는 서로 상충관계가 있으므로 퍼지제어기를 최적화하기 위하여 두 응답을 목적함수로 하는 다목적 유전자알고리즘을 사용하여하였다. 수치해석결과 본 연구에서 제안한 스마트 면진시스템을 적용하면 최적설계된 LRB 시스템에 비하여 면진층 변위 및 대공간 구조물의 동적응답을 대폭 줄일 수 있는 것을 확인하였다.
        4,200원
        14.
        2009.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기존의 교량받침으로 많이 사용되고 있는 폴리우레탄 디스크를 적용한 POT형식에 C형 강재감쇠장치를 추가적으로 적용한 새로운 형태의 지진격리장치에 대한 명확한 정적 성능검증과 동적특성을 파악하기 위하여 최대 극한 수직하중 시험, 최대 회전 시험, 동적재하 시험 및 동적재하 극한 반복시험을 시행하였다. 해석적 결과와 성능시험 결과를 비교분석한 결과, 충분한 감쇠능력을 보유하고있을 뿐만 아니라, 설계기준에도 적합하다는 결론을 얻을 수 있었다. 또한, EDC 및 유효강성값의 시험치가 이론치와 유사하여 시험 결과값의 분석이 유효함을 보였다.
        4,200원
        15.
        2008.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 지진으로부터 구조물을 효과적으로 보호하기 위하여 MR 엘라스토머(MRE)를 이용한 새로운 형태의 스마트 기초격리 시스템을 제안하고, 이에 대한 내진성능을 파악하였다. MRE는 자성물질을 포함한 실리콘 혹은 고무로써 자기장에 의해 강성이 변하는 스마트 재료이다. 기초격리 시스템은 토목 및 건축분야에서 구조물의 내진성능 향상을 위해 가장 널리 쓰이는 장치로 지반과 구조물을 격리시켜 구조물에 가해지는 입력 하중을 감소시켜주는 장치이다. 기존 수동형태의 기초격리 장치는 다양한 입력하중에 대한 적응성이 부족하고 기초격리 장치에서의 과도한 변위 등의 단점이 있는 반면, 새로 제안한 시스템은 제어 가능한 강성범위가 넓어 이를 개선할 수 있다. MRE를 이용한 기초격리 장치의 성능을 확인하기 위하여 기초격리 장치를 도입한 단층 및 5층의 건물에 대해 다양한 역사지진 하중을 이용하여 수치해석을 수행하였다. 수치해석 결과, 제안된 시스템은 기존 수동형태의 시스템에 비해 구조물의 응답 및 기초격리장치의 변위를 감소시키는 데 탁월한 효과가 있음을 확인하였다.
        4,000원
        16.
        2008.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        면진장치 중에서 최근 많은 연구가 이루어지고 있는 마찰진자 베어링은 적절한 마찰력을 얻기 위해 PTFE(Polytetrafluoroethylene) 마찰재가 이용되고 있다. 본 연구에서는 자력의 반발력을 이용해 재료의 성질을 대체하여 면진성능을 향상 시킬 수 있는 자력을 이용한 마찰진자 베어링을 제안하였다. 제안된 시스템은 자력에 의한 반발력이 수직력을 줄여줌으로써 재료에 의한 마찰계수의 영향을 줄일 수 있음을 가정하였다. 또한 자력의 영향을 가정하기 위해서 간단한 실험을 구성해 보았으며, 자력이 작용을 할 때 마찰계수(\mu)를 약 20%정도 줄여줄 수 있었다. 실험 결과를 적용한 수치해석을 통해 다양한 지진에 대해서 기존의 마찰진자 베어링보다 향상된 성능을 보여주었고, 특히 지진으로 인해 구조물의 파괴에 작용하는 주된 요소인 최상층의 가속도와 구조물의 상대변위를 비교함으로써 제안된 시스템이 면진장치로서의 기능을 가지고 있음을 확인하였다. 자력을 이용하여 기존의 PTFE 마찰재를 대체할 수 있는 자력을 이용한 마찰진자 베어링의 구조적 설계를 할 수 있다면 마찰진자 베어링의 문제점을 보완한 기초격리장치로서 적용될 수 있을 것으로 사료된다.
        4,000원
        17.
        2006.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 들어 지진발생 빈도의 증가와 더불어 초고층 빌딩, 장대교량 등과 같은 대형구조물의 경량화, 유연화로 인해 발생하는 구조물의 과도한 동적거동을 효과적으로 제어할 수 있는 제진시스템의 필요성이 증가하고 있다. 본 연구에서는 지진으로부터 구조물을 보다 효과적으로 보호하기 위해 자기장에 의해 역학적 성질을 변화시킬 수 있는 제어가 가능한 지능형재료인 자기민감 고무(Magneto-Sensitive Rubber)를 이용한 반 능동 기초격리 시스템을 제안하였다. 제안된 기초격리 시스템은 기존의 LRB(Lead-Rubber Bearing) 시스템과의 비교 분석을 통해 면진성능을 평가하였으며 이를 위해 몇 가지 역사적 지진들을 이용수치해석을 수행하였다. 제안된 자기민감 고무를 이용한 반 능동 기초격린 시스템은 기존의 수동 시스템보다 기초전단력이나 상부구조물에 가속도 전달을 차단함과 동시에 기초변위를 현저하게 감소시킬 수 있음을 보였다. 그러므로 자가민감 고무를 이용한 반 능동 기초격리 시스템은 지진으로부터 구조물을 효과적으로 보호할 수 있을 것으로 사료된다.
        4,000원
        18.
        2005.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        현재까지 많은 스마트 면진시스템이 제안되었고 연구되어 왔다. 본 연구에서는 스마트 면진시스템의 면진장치와 보조감쇠 장치로서 새로운 형태의 마찰진자시스템(FPS)과 MR 감쇠기를 각각 사용한다. 퍼지로직제어기(FLC)가 고유의 견실성과 비선형 및 불확실성을 쉽게 다룰 수 있는 능력이 있기 때문에 MR 감쇠기의 감쇠력을 조절하는데 FLC를 사용한다. 또한 FLC의 성능을 최적화 하기 위해서는 유전자알고리즘(GA)을 사용한다. GA를 사용함으로써 소속함수의 형상을 조절하는 것뿐만 아니라 적절한 퍼지제어규칙을 결정할 수 있다. 이를 위하여 본 연구에서는 부분개선 유전자알고리즘을 사용하였다. 이 방법은 유전자의 특정부분을 향상시키는데 효율적이다. FPS와 MR 감쇠기의 동적거동을 표현하기 위해서는 뉴로?퍼지 모델을 사용한다. FLC의 최적설계를 위하여 본 연구에서 제안된 방법의 효율성은 여러 가지 역사지진을 사용하여 계산된 동적응답을 기초로 하여 평가한다. 예제해석결과 제안된 방법은 적절한 퍼지규칙을 찾을 수 있고 GA로 최적화된 FLC는 수동제어기 뿐만 아니라 전문가의 지식에 기반한 FLC와 전통적인 준능동제어기보다 더 좋은 성능을 발휘한다.
        4,000원
        19.
        2004.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        사장교에 발생하는 지진에 의한 진동을 감소시키기 위해 추가적인 능동/반능동 제어장치를 부착한 LRB-기반 복합 기초격리 시스템에 대한 논문이다. 복합 기초격리 시스템은 제어장치가 다중으로 작동하기 때문에 LRB가 설치된 교량 시스템과 같은 수동형 기초격리 시스템에 비해 제어 성능이 뛰어나다. 본 논문에서는, LQG 알고리듬에 의해 제어되는 능동형 유압식 가력기와 clipped 최적제어에 의해 제어되는 반능동형 자기유변 유체 (MR) 감쇠기를 추가적인 제어장치로 고려하여 추가적인 응답 감소 효과를 검토하였다. 이를 위해, 미국토목학회의 1단계 벤치마크 사장교에 LRB를 설치한 교량을 고려하였다. 수치해석 결과를 통해, 모든 LRB-기반 복합 기초격리시스템이 구조물의 응답을 효과적으로 감소시킴을 확인하였다. 또한, MR 감쇠기를 채택한 복합 기초격리 시스템은 구조물 강성의 불확실성에 대해 강인성을 보였지만 유압식 가력기를 채택한 경우에는 강인성이 부족함을 알 수 있었다. 따라서, 반능동형 추가 제어장치를 채택한 복합 기초격리 시스템의 대형 토목구조물에 대한 적용가능성이 제어 성능 및 강인성 면에서 분명하게 검증되었다
        4,500원
        20.
        1996.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        건물기초롤 지진절연하면 건물뿐만 아니라 그 내부구조물의 지진웅답도 크게 감소한다는 사실이 많은 연구 를 통해 확인되어 왔다. 그런데 이러한 내부구조물이 유체내에 잠기고 부가질량효과가 크게 작용되는 조건에 놓이는 경우 오히려 지진응답이 중가할 수 있다. 본 논문은 건물 내 수중구조물의 지진해석올 통해 그러한 예 를 제시하고자 한다. 해석결과 지진절연된 건물의 경우 이러한 내부 수중구조물의 지진웅답이 상당히 증가할 수 있기 때문에 이에 대한 조치가 필요함을 보였고, 적절한 설계에 의하여 부가질량효과를 조절함으로써 어느 정도 응답을 줄일 수 있다는 사실을 알 수 있었다.
        4,000원