검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 101

        1.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to select target fish species as baseline research for accumulation analysis of major hazardous chemicals entering the aquatic ecosystem in Korea and to analyze the impact on fish community. The test bed was selected from a sewage treatment plant, which could directly confirm the impact of the inflow of harmful chemicals, and the Geum River estuary where harmful chemicals introduced into the water system were concentrated. A multivariable metric model was developed to select target candidate fish species for hazardous chemical analysis. Details consisted of seven metrics: (1) commercially useful metric, (2) top-carnivorous species metric, (3) pollution fish indicator metric, (4) tolerance fish metric, (5) common abundant metric, (6) sampling availability (collectability) metric, and (7) widely distributed fish metric. Based on seven metric models for candidate fish species, eight species were selected as target candidates. The co-occurring dominant fish with target candidates was tolerant (50%), indicating that the highest abundance of tolerant species could be used as a water pollution indicator. A multi-metric fish-based model analysis for aquatic ecosystem health evaluation showed that the ecosystem health was diagnosed as “bad conditions”. Physicochemical water quality variables also influenced fish feeding and tolerance guild in the testbed. Eight water quality parameters appeared high at the T1 site, indicating a large impact of discharging water from the sewage treatment plant. T2 site showed massive algal bloom, with chlorophyll concentration about 15 times higher compared to the reference site.
        5,100원
        3.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to measure sedimentation status change with the changes in internal pressure for dry chemical extinguishers of various use periods and analyze the suitability of the fire extinguishers' performance criteria. When the internal pressure of the fire extinguisher is 0%, 2 out of 10 new dry chemical powders for the 5 elapsed years were noted to be suitable, including 3 recycled dry chemical powders with 5 elapsed years that were found eligible. One out of 10 new dry chemical powders for 10 elapsed years was shown as suitable. Also, one new dry chemical powder for 13 elapsed years was suitable. When the internal pressure of the fire extinguisher was 50%, all 10 out of 10 new dry chemical powders for 5 years, recycled one with 5 elapsed years, and a new one with 10 elapsed years were found to be suitable, while 9 new dry chemical powders for 13 years were shown as suitable. When the internal pressure of the fire extinguisher was normal, new ones with 5 elapsed years, recycled ones with 5 elapsed years, new ones with 10 elapsed years, and new ones with 13 elapsed years were all 10 out of 10 samples noted as suitable. In summarizing the experiment results, it was found that the sedimentation status, one of the fire extinguisher's physical properties experiments, affects the fire extinguisher's performance criteria rather than the change with use periods.
        4,000원
        8.
        2021.03 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Chemical decontamination of primary systems in a nuclear power plant (NPP) prior to commencing the main decommissioning activities is required to reduce radiation exposure during its process. The entire process is repeated until the desired decontamination factor is obtained. To achieve improved decontamination factors over a shorter time with fewer cycles, the appropriate flow characteristics are required. In addition, to prepare an operating procedure that is adaptable to various conditions and situations, the transient analysis results would be required for operator action and system impact assessment. In this study, the flow characteristics in the steady-state and transient conditions for the chemical decontamination operations of the Kori-1 NPP were analyzed and compared via the MARS-KS code simulation. Loss of residual heat removal (RHR) and steam generator tube rupture (SGTR) simulations were conducted for the postulated abnormal events. Loss of RHR results showed the reactor coolant system (RCS) temperature increase, which can damage the reactor coolant pump (RCP)s by its cavitation. The SGTR results indicated a void formation in the RCS interior by the decrease in pressurizer (PZR) pressure, which can cause surface exposure and tripping of the RCPs unless proper actions are taken before the required pressure limit is achieved.
        4,000원
        9.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The purpose of this study is to evaluate the asphalt binder properties using FTIR analysis. METHODS : To investigate the chemical properties of asphalt binders, FTIR tests were performed. Recently, FTIR was used for quantification under various aging conditions. Three scans were averaged for each sample within the wavenumber range of 4000 to 400 cm-1, at a resolution of 4 cm-1 (default Simatech software settings). To determine the oxidation of the extracted asphalt binder and the remaining TCE solution in the extracted asphalt binder, the penetration test was adopted and compared. To track the changes in the chemical composition of the aged bitumens, the ATR spectrum of each sample was analyzed, both qualitatively and quantitatively. The qualitative analysis involved identifying characteristic absorption peaks for the functional group of interest, such as polymer components, carbon and sulfur oxidation products, and polar aromatics. RESULTS : The asphalt binder is easily oxidized in air during FTIR testing. To reduce the oxidization of the asphalt binder, the asphalt binder must avoid air contact to measure constant results. Sometimes, the extracted asphalt binder has a residual solvent (TCE), which affects the evaluation of the extracted asphalt binder rheology, such as absolute viscosity and penetration testing. To solve this problem, the research team adopted the FTIR test method. First, the TCE was scanned with FTIR to obtain the chemical characteristics of TCE. After that, the extracted asphalt binder was scanned and the FTIR spectra were compared with those of TCE. If there is a TCE in the extracted asphalt binder, a typical peak was found in the spectrum. Thus, it is possible to estimate the content of the TCE remaining in the extracted asphalt binder via the FTIR test method. CONCLUSIONS : It is possible to evaluate the aging of asphalt binder through FTIR analysis used for the analysis of the chemical structure of asphalt. In addition, during FTIR analysis, the sample is required to avoid air contact to obtain accurate results. FTIR analysis was conducted to confirm whether the solvent (TCE) remained in the extracted asphalt binder and it was confirmed that the penetration increased by a factor of two when the solvent remained. This suggests that it is difficult to control the quality of the asphalt mixture by controlling the amount of recycled additive, as well as the aging of the extracted asphalt binder.
        4,000원
        10.
        2021.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 석유화학제품 산적운송선(화학유조선)에 의한 해상운송 과정에서 발생한 위험․유해물질(HNS) 관련 해상화학사 고에 대하여 국내 및 국외의 주요 사례를 조사․분석함으로써 얻은 교훈을 소개하고, 이러한 교훈을 바탕으로 국내 해상HNS 교육과정 개 선방안을 제시하였다. 6건의 사고사례를 통하여 얻은 교훈을 1) 사고관련정보, 2) 안전, 3) 오염, 4) 대응, 5) 구난, 6) 기타와 같은 6개 분야로 분류하였다. 각 분야의 세부항목별로 요약된 교훈을 바탕으로 해양환경교육원(MERTI) 유해액체물질운반선 해양오염방지관리인 교육과정을 현행 8개 교과목(16시간)의 2일간 교육을 16개 교과목(24시간)의 3일간 교육으로 개선하는 방안을 제시하였으며, 또한 해양경찰교육원 (KCGA) 전문교육 해양화학사고대응 과정을 현행 15개 교과목(35시간)의 5일간 교육을 32개 교과목(48시간)의 6일간 교육으로 개선하는 방안을 제시하였다. 이러한 연구결과는 해상화학사고 대응에 관한 경험과 교훈을 서로 공유하는 데에 기여하고, 해상HNS사고에 대비한 대응 인력 교육․훈련과정 개선의 기초자료로 활용될 수 있을 것으로 기대된다.
        4,900원
        12.
        2020.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, to improve the logistics flow of existing given chemical logistics warehouse, four logistics flow alternatives were proposed to minimize truck interference by building simulation model. The simulation model for chemical storage warehouse was built to evaluate system performance. Among the four new improved alternatives based on the basic model, the model with the same truck’s pathways and locations of facilities identified an increase in the number of interferences but a decrease in daily working hours as the number of resources in a particular facility increases. Therefore, the three groups were classified as ‘efficiency’, ‘complementary’, and ‘safety’ based on the daily working hours, and the ratio of trucks entering two types of logistics warehouse was set in consideration of future market fluctuations. For each of the six types, the optimal number of resources was selected as the number of resources in the facilities with the least number of interferences in the basic model and the evaluation measures and characteristics set in this study were compared and analyzed. As a result, the Alternative 4 model operating the underground roadway produced interference between 17.0% and 36.4% of the basic model, with 113.3% of the interior loadspace.
        4,000원
        18.
        2019.03 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Surface plasmon resonance is the resonant oscillation of conduction electrons at the interface between negative and positive permittivity material stimulated by incident light. In particular, when light transmits through the metallic microhole structures, it shows an increased intensity of light. Thus, it is used to increase the efficiency of devices such as LEDs, solar cells, and sensors. There are various methods to make micro-hole structures. In this experiment, micro holes are formed using a wet chemical etching method, which is inexpensive and can be mass processed. The shape of the holes depends on crystal facets, temperature, the concentration of the etchant solution, and etching time. We select a GaAs(100) single crystal wafer in this experiment and satisfactory results are obtained under the ratio of etchant solution with H2SO4:H2O2:H2O = 1:5:5. The morphology of micro holes according to the temperature and time is observed using field emission - scanning electron microscopy (FE-SEM). The etching mechanism at the corners and sidewalls is explained through the configuration of atoms.
        4,000원
        19.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyzed the water quality characteristics and developed empirical models prior to and after the construction of Baekje Weir, in the Geum River watershed between 2004-2017. The comparative evaluation of the surface water chemistry before and after the four major river projects on the weirs indicated that total phosphorus (TP), based on annual data, rapidly decrease after the construction of the weir while the total nitrogen (TN) decreased. Conversely, chlorophyll-a (CHL) concentration, which is a good indicator of primary productivity, increased after the construction of the weir together with an increase in specific conductivity. Simply put, the construction of the weir led to the decrease in concentrations of N and P due to the increased water residence time (WRT), whereas the CHL : TP ratio greatly increased in magnitude. The regression analysis of the empirical model indicated that CHL had no significant relation (r=0.068, p=0.6102, n=58) with TP before the weir construction, but had a relation with TP after the weir construction (r=0.286, p<0.05, n=56). Therefore, such conditions resulted in an increase in primary productivity on a given unit of phosphorus, resulting in frequent algal blooms. In contrast, seasonal suspended solids (SS) and TP increased during the monsoon period, compared to the pre-monsoon, thereby showing positive correlations (r>0.40, p<0.01, n=163) with precipitation. If the government consistently discharges water from the weir, the phosphorus concentration will be increased due to its reversion to a lotic waterbody from a lentic waterbody hereby reducing algal blooms in the future.
        4,300원
        20.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        항공유는 문제가 발생 시 대형사고로 이어질 수 있기 때문에 다른 수송용 연료보다 더 엄격히 관리되고 있다. 항공유의 품질기준은 국내의 한국산업표준(KS), 미국재료협회(ASTM)와 국제운송협회(IATA)에서 각각 규정하고 있다. 2016년부터 2017년까지 국내 정유사의 5개 공장에서 생산되는 항공유에 대하여 방향족 함량, 황 함량 및 증류성상 등 6개 항목에 대하여 품질분석을 실시하였다. 국내에서 생산된 항공유는 품질기준에 적합한 것으로 나타났으며, 연간 일정하게 유지되고 있었다. 국제기준인 ASTM과 IATA의 품질기준과 비교했을 때, 방향족 함량은 국내 KS 기준이 ASTM 및 IATA 설정기준보다 1.5 wt% 엄격하게 설정되어 있으나 이 기준을 충분히 만족시키는 것으로 나타났다. 또한, 황 함량, 증류성상 및 인화점 등 나머지 항목들도 국내와 국제기준을 모두 충족하는 것으로 나타났다.
        4,200원
        1 2 3 4 5