This study aims to measure sedimentation status change with the changes in internal pressure for dry chemical extinguishers of various use periods and analyze the suitability of the fire extinguishers' performance criteria. When the internal pressure of the fire extinguisher is 0%, 2 out of 10 new dry chemical powders for the 5 elapsed years were noted to be suitable, including 3 recycled dry chemical powders with 5 elapsed years that were found eligible. One out of 10 new dry chemical powders for 10 elapsed years was shown as suitable. Also, one new dry chemical powder for 13 elapsed years was suitable. When the internal pressure of the fire extinguisher was 50%, all 10 out of 10 new dry chemical powders for 5 years, recycled one with 5 elapsed years, and a new one with 10 elapsed years were found to be suitable, while 9 new dry chemical powders for 13 years were shown as suitable. When the internal pressure of the fire extinguisher was normal, new ones with 5 elapsed years, recycled ones with 5 elapsed years, new ones with 10 elapsed years, and new ones with 13 elapsed years were all 10 out of 10 samples noted as suitable. In summarizing the experiment results, it was found that the sedimentation status, one of the fire extinguisher's physical properties experiments, affects the fire extinguisher's performance criteria rather than the change with use periods.
In the pilot scale test, the two scale-up factors (Electric energy per order EEO, Electric energy per mass EEM) were conducted to design the Chemical Waste Decomposition & Treatment System (CWDS). The CWDS consist of two kind UV lamp reactors to improve the decomposition rate of oxalic acid, which are low pressure amalgam UV lamp and medium pressure UV lamp. The two reactors were connected in series, and the hydrogen peroxide is mixed through a line mixer at the front of the reactor and injected into the reactors. The CWDS was connected with the full system decontamination equipment to purify the residual oxalic acid after chemical decontamination process. The full system decontamination equipment were included Oxidizing Agent Manufacturing System (OAMS), Chemical Injection System (CIS), RadWaste Treatment System (RWTS) to operate the Oxidation/Reduction decontamination process and purify the process water. After decontamination process, the waste water will be cooled down into the 40°C and passed through the UV reactor at 110 gpm with hydrogen peroxide injection. The concentration of waste water is expected oxalic acid 1,700 ~ 2,000 ppm, Iron 5 ~ 20 ppm. As a result of the CBD test in the laboratory with simulated waste liquid, the amount of Low pressure amalgam lamp UV dose required to decompose 95% of oxalic acid in 2 m2 waste water was up to 1,800 mJ/cm2. The amount of medium pressure lamp UV dose was up to 450 mJ/cm2 at the same condition. We conducted demonstration test using 2 m2 waste water after the oxidation/reduction decontamination process, the decomposition rate 95% was obtained by low pressure amalgam UV lamp and medium pressure UV lamp reactor each.
Aquatic ecosystems are receiving various harmful effects due to anthropogenic chemical pollutions. To protect wildlife, risk assessments of the chemicals are conducted using reference indexes of toxicity estimated by species-level laboratory tests and/or micro-/mesocosm community-level studies. However, the existing micro-/mesocosm communities are structurally too complicated, and it is also difficult to compare the experimental results directly with those from species-level tests. Here, we developed a procedure of a simple bi-trophic microcosm experiment which contains the common species (a green algae, Pseudokirchneriella subcapitata and a cladoceran, Daphnia magna) for testing chemical toxicities. For the proper operation of bitrophic microcosm experiment, the minimum required concentration of primary producer (P. subcapitata) is 5×105 cells mL-1. The microcosm system showed higher stability when the initially introduced D. magna population was composed of neonates (<24-h old) than adults and those mixture. This simple microcosm system would be an applicable tool to estimate the disturbing impacts of pollutants on plant-herbivore interactions, and linking the species- and population-/community level risk assessments in the future studies.
저방사성폐수지, 제올라이트, 가연성잡고체 혼합폐기물을 유리화하기 위해서 AG8W1 후보 유리와 가연성잡고체 단독으로 유리화하기 위하여 DG-2 후보유리가 개발되었다. 두 후보유리의 화학적 내구성을 평가하기 위하여 PCT와 VHT 침출시험이 수행되었다. 7일 PCT 침출시험 수행결과 AG8W1과 DG-2의 주요 원소별 침출률은 기준유리(benchmark glass SRL-EA) 보다 낮게 나타남을 알 수 있었고 미국 Hanford 유리고화체 규제치 보다 낮은 결과를 나타냄을 알 수 있었다. 또한, 120일 동안의 시험에서도 주요 원소인 B, Na, Si, Li가 SRL-EA 보다 낮게 나타남을 볼 수 있었다. VHT 침출시험 수행결과 AG8W1, DG-2의 침출률(leach rate)은 각각 , 로써 미국 Hanford 규제치 보다 낮은 결과를 나타냈다. 결과적으로 유리화 시설 상용운전 시 사용예정인 이들 후보유리들의 침출은 안정화되어 있었으며 화학적 내구성이 우수함을 알 수 있었다.
Chemical composition of imported table salts from China (sun dried), Thailand (sun dried) and Australia (rock salt) were compared the mineral content and heavy metal contamination with Korean sun dried salt. Kimchies prepared by those salts were analyzed the quality by pH, acidity and sensory evaluation. Chemical compositions were as follows : moisture-from 1.7% (Australia) to 8.7% (Korea), sodium chloride-from 86.7% (China, summer) to 97% (Australia), insoluble matter in water-from 0.02% (Australia) to 0.18 (China), and sulfate ion-from 0.03% (Australia) to 1.65% (China, summer). Judging by Korean Standard(KS) of salt, salt from Australia and Thailand belong to lst grade, Korean and Chinese (winter) to 2nd grade, and China (summer) were out of 3rd grade. Ca and Mg content of the salts tested were 0.022% (Australia) to 0.246 (China, winter), 0.036% (Australia) to 0.$41% (China, summer) respectively and Pb was 1.23 ppm(China, summer)-0.61ppm(Korea) which is within the Korean regulation. The other heavy metals, Pb, Cd, As and Hg were not detected in all salts tested. The quality of Kimchi prepared by those salts were significantly no difference with Korean sun dried salt.
The National Environmental Specimen Bank (NESB) has been sampling and cryogenically preserving various wildlife specimens to monitor bio-accumulations of chemical pollutants since 2010. Recently, the NESB set up a plan to develop reference materials at their facility to assure the analytical quality of and validate the analytical methods for their monitoring samples. One of the crucial characteristics of reference materials is intra- and inter-bottle homogeneity. In this study, we used ANOVA for total mercury concentrations in some samples to validate their homogeneities after milling and homogenization. We examined the intra- and inter-bottle homogeneities of two cryogenically-milled samples (Korean mussel (Mytilus coruscus) and black-tailed gull’s egg (Larus crassirostris). The variations in the total mercury concentrations were not significantly different intra- and inter-bottle (mussel: F=0.74, p=0.67; gull egg: F=1.96, p=0.10). Additionally, the relative standard deviations of the total mercury concentrations showed low values (mussel: 2.02%, gull egg: 1.78%). Therefore, the cryogenic-milling process statistically proves the homogeneity of the materials of mussels and sea gull eggs for chemical analysis for total mercury.
본 연구에서는 유황을 폴리머화하여 내화학성능이 요구되는 구조물의 콘크리트 표면보호재로 활용할 수 있도록 성능을 검토하였다.평가 결과, 유황폴리머 표면도포재의 중력식 스프레이가 적절한 것으로 나타났으며, 도포횟수는 왕복 3회 이상 도포했을 때 1MPa 이상의 부착강도 확보가 가능하였다. 표면보호재가 도포될 콘크리트 표면조건은 상온조건 (20~30℃) 이상에서 높은 부착강도를 나타내었으며,온도가 높을수록 부착강도가 증가하였다. 표면보호재의 채움재 혼입량에 따른 강도특성 평가결과, 20~40% 정도 혼입된 채움재는 유황폴리머의 수축을 저감시키는 효과를 나타내어 강도 향상에 기여하였다. 또한, 플라이애시 보다는 규사 혼입시 부착강도가 높았고, 동시 혼입시가장 우수한 부착강도 특성을 나타내었다. 화학저항성은 플라이애시 및 규사를 각각 20% 대체한 배합에서 부착강도 저하가 최소로 되어우수한 내화학성을 나타내었다. 염소이온 침투에 대한 성능평가를 수행한 결과, 표면보호재를 도포하지 않은 시험체에 비하여 유황폴리머표면보호재를 도포한 경우, 29~48% 정도 염소이온침투저항성이 증대되었다. 표면보호재의 도포조건, 압축강도, 부착강도, 화학저항성, 염해저항성 등을 모두 고려하여 볼 때, 본 연구범위에서는 유황폴리머에 채움재로서 규사와 플라이애시를 각각 20%씩 대체하는 것이 적절한수준인 것으로 판단된다.
초음파 검사는 복강내 장기를 검사하는 대표적인 영상의학검사의 한 분야이며. 혈액검사는 체내 이상 징후를 임상 화학적으로 검사하는 대표적인 방법이다. 지방간의 진단은 주로 복부초음파 검사와 혈액검사를 동시에 실시하여 수행하며 두 검사의 결과를 바탕으로 진단을 하게 된다. 이 경우에 실시하는 혈액검사의 기준은 TBIL, TC, AST, ALT,ALP, GGT, TG, HDL-C, GLU의 값이다. 본 연구에서는 초음파 영상에서 지방간 진단을 받은 환자의 혈액검사 정확성을 분석하여 두 종류의 검사간 정확도를 분석하고자 하였다. 2012년 1월부터 3월간 종합검진으로 복부초음파검사와 혈액검사를 동시에 받은 환자 1350명 중 초음파 검사 상 지방간 판정을 받은 459명을 대상으로 초음파 검사와 혈액검사 결과가 동일한 경우는 459명 중 280명으로 약 60.8% 이며, 초음파 검사와 혈액검사의 결과가 서로 다른 경우는 179명으로 39.2%로 밝혀져 초음파 검사와 혈액검사의 진단 정확도는 60.8% 이었다. 이는 지방간의 초음파 진단시 종사자의 주관적 능력이 병변의 진단에 큰 영향을 미친 것으로 생각되어 지속적인 초음파 임상 교육이 필요할 것으로 사료된다.