        1.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : This study provides fundamental information on the temperature variations in tunnel structures during severe fire events. A fire event in a tunnel can drastically increase the internal temperature, which can significantly affect its structural safety. METHODS : Numerical simulations that consider various fire conditions are more efficient than experimental tests. The fire dynamic simulator (FDS) software, based on computational fluid dynamics (CFD) and developed by the National Institute of Standards and Technology, was used for the simulations. The variables included single and multiple accidents involving heavy goods vehicles carrying 27,000 liters of diesel fuel. Additionally, the concrete material characteristics of heat conductivity and specific heat were included in the analysis. The temperatures of concrete were investigated at various locations, surfaces, and inside the concrete at different depths. The obtained temperatures were verified to determine whether they reached the limits provided by the Fire Resistance Design for Road Tunnel (MOLIT 2021). RESULTS : For a fire caused by 27,000 liters of diesel, the fire intensity, expressed as the heat release rate, was approximately 160 MW. The increase in the carrying capacity of the fire source did not significantly affect the fire intensity; however, it affected the duration of the fire. The maximum temperature of concrete surface in the tunnel was approximately 1400 ℃ at some distance away in a longitudinal direction from the location of fire (not directly above). The temperature inside the concrete was successfully analyzed using FDS. The temperature inside the concrete decreased as the conductivity decreased and the specific heat increased. According to the Fire Resistance Design for Road Tunnel (MOLIT 2021), the internal temperatures should be within 380 ℃ and 250 ℃ for concrete and reinforcing steel, respectively. The temperatures were found to be approximately 380 ℃ and 100 ℃ in mist cases at depths of 5 cm and 10 cm, respectively, inside the concrete. CONCLUSIONS : The fire simulation studies indicated that the location of the maximum temperature was not directly above the fire, possibly because of fire-frame movements. During the final stage of the fire, the location of the highest temperature was immediately above the fire. During the fire in a tunnel with 27,000 liters of diesel, the maximum fire intensity was approximately 160 MW. The capacity of the fire source did not significantly affect the fire intensity, but affected the duration. Provided the concrete cover about 6 cm and 10 cm, both concrete and reinforcing steel can meet the required temperature limits of the Fire Resistance Design for Road Tunnel (MOLIT 2021). However, the results from this study are based on a few assumptions. Therefore, further studies should be conducted to include more specific numerical simulations and experimental tests that consider other variables, including tunnel shapes, fire sources, and locations.
        4,200원
        2.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        공동주택 방화문의 화재성능 결함으로 인하여 하자소송이 확대되고, 화재발생 시 치명적일수 있다. 그러나 현행 법령은 이에대한 대책이 소홀한 편이다. 본 연구에서는 방화문의 결함과 특성 등을 잘 반영하고 있는 『강제창호 제작・품 질검수 매뉴얼』과 LH 설계・시방서 개정작업에서 드러난 문제점들에 대한 개 선방안을 제시하고자 한다. 방화문의 적정단가를 산정하고 내용연수를 합리적 으로 조정하며 3단계 점검시스템 등 관련규정을 신설 운영한다면, 방화문 품질 성능 향상과 화재시 입주민 보호에 크게 기여할 것으로 판단된다.
        6,100원
        3.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A two-hour fire-resistance PC hollow slab for residential use was developed to secure structural and fire-resistance performance and to be applied to the general building and apartment housing markets. Compared to the existing hollow slab, in order to secure the same or better structural performance and economic feasibility by reducing the quantity, it was attempted to secure the fire resistance performance by reducing the concrete filling rate in the cross section and adjusting the thickness of the upper and lower flanges by optimizing the hollow shape in the cross section of the slab. For structural performance evaluation, experiments were performed on PC hollow slabs by varying the member thickness and the presence or absence of overlaid concrete, and all of the experimental results showed that the design strength was sufficiently exhibited and that stability during construction was possible. The developed synthetic PC hollow slab has secured fire resistance and residential performance so that it can be applied to all buildings, and it is intended to be immediately applied to the field.
        4,000원
        5.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        콘크리트 충전강관은 국부좌굴을 방지하고 내화성이 향상되기 때문에 건설현장에서 많이 적용되며 휨성능을 향상시 키기 위해 강관 내부에 철근을 보강하여 사용한다. 그러나 철근은 부식되며 내구성이 저하되기 때문에 이를 대신할 소재에 대 한 연구가 진행되고 있다. 탄소섬유보강근은 철근에 비해 경량이며 고강도와 내부식성이 우수하다는 이점이 있다. 그러나 임계 온도가 250℃로 철근의 임계온도인 538℃에 비해 현저히 낮기 때문에 내화피복이 필요하다. 따라서 열전달해석을 통해 탄소섬 유보강근을 사용하였을 때 온도분포를 확인하고 P-M상관도를 도출하여 적용 가능여부를 확인하고자 한다. 해석결과 내화성능을 확보하기 위해 콘크리트 피복두께 40mm, 뿜칠내화피복재 30mm를 적용하거나 콘크리트 피복두께 60mm, 뿜칠내화피복재 20mm 를 적용하면 3시간 내화성능을 만족하는 것으로 평가되었다.
        4,200원
        7.
        2022.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        교각의 내구성 증진 및 내진 보강을 위하여 원형철근 콘크리트 교각 외부에 강판을 보강한 경우, 교각 외부에서 발 생하는 화재에 대해 보강된 교각의 내화성능을 정량적으로 평가하였다. 범용유한요소해석프로그램 ABAQUS를 이용하였으며 ISO 834-1의 표준화재곡선을 적용하여 교각의 거동을 해석하였다. 해석 변수로는 강판보강두께와 원형교각 지름의 비, 교각에 수직으로 작용하는 축력비를 적용하였다. 교각의 상부와 하부는 힌지-롤러 경계조건을 고려하여 상부는 수직으로 변위가 발생하 도록 하였으며, 교각 외부 전체에 열하중을 가하였고 편심 없는 순수 축하중을 교각 중앙에 가력하였다. 온도에 따른 콘크리트, 철근 및 강재의 비열, 열전도율, 탄성계수 등을 고려하여 보강에 따른 교각의 내화 성능 향상도를 평가하였다. 강판으로 보강한 원형철근 콘크리트 교각은 콘크리트의 중심부일수록 강판 두께의 영향을 받지 않으며 강판 두께별 축력을 주 었을 때 내화시간은 축력비 0.7에서 최대 약 3분 향상되었다. 또한, 보강두께가 두꺼울수록 내하력이 향상하며 60분 이후에 모 두 내하력비가 1.0 이하로 감소하기 시작하는 것을 알 수 있었다. 강판보강공법은 내화성능을 향상시킬 수 있으며 강판 보강 두 께와 보강 지름의 비가 클수록 화재에 대해 축방향에 대한 변위와 내하력이 증가하는 것으로 나타났다. 본 연구결과를 토대로 원형철근 콘크리트 교각의 외부 강판 보강을 통하여 교각의 내화 성능을 향상시킬 수 있음을 정량적으로 판단할 수 있었다.
        4,000원
        9.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        최근 들어 아라미드 섬유 시트는 건설 산업에 쉽게 사용되고 있다. 아라미드 섬유 시트는 높은 특성강도 및 강성, 높은 부식 저항성능, 경량 및 자기적 투명성과 같은 많은 장점을 제공한다. 본 연구에서는 아라미드 섬유 시트의 난연성능 및 접착강도가 연구되었다. 아라미드 섬유 보강 콘크리트 기둥의 내화성능은 표준 및 외부화재 곡선에 대해 서로 다른 조합의 보드 두께와 종류로 제작된 6개의 실험체를 사용하여 연구되었다. 그 결과 아라미드 섬유 시트는 마감재료를 이용해서 한 시간의 내화성능을 가지는 것으로 나타났다.
        4,000원
        10.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In fire design for floors, the three criteria of stability, integrity and insulation are required for the specified fire resistance duration. Among these, stability is not easy to confirm. For solid prestressed concrete slabs of uniform thickness, Eurocode 2 provides tabulated data and specifies an axis distance to the centroid of strands to achieve particular fire resistance ratings, but it is not clear if this data can be used for a wide range of different prestressed slab profiles. In order to verify the current code-fire ratings for precast prestressed slabs, both simple and advanced calculation methods are investigated. This paper examines the use of calculation methods, accounting for the real behaviour of unprotected simply supported prestressed concrete slabs exposed to the standard ISO 834 fire. The calculated fire resistance of each prestressed concrete slab is compared with tabulated data in Eurocode part 1.2, with detailed discussion.
        4,000원
        11.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Structures of steel frame buildings getting vary depending on the development of construction technology. Fire-resistant steel beams and Columns accredited by accreditation bodies from the performance of various fire-resistant coating is applied to the current pillar method is most H-beams. H-beam has been proposed a non-load test specifications in the relevant regulations, its scope of accreditation to be granted without limitation of size H-beams from the performance of the test specification. However, in the case of the rectangular steel structure is to check its performance and to a separate one of the receive acknowledge and so take advantage of the cross-sectional shape factor in this study to test the performance of the fire-resistant structure proposed for standard test specimen.
        4,000원
        12.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        SLIM AU(A plus U-shaped) composite beam was developed for reducing the story height in the residential buildings, and saving the cosrtuction cost of floor structures. Structural performance and economic feasibility of the composite beam have been sufficiently approved through the structural experiments and the analytical studies. However, the verification for fire safety is necessary for the practical application of the composite beam. The fire resistance tests with and without loading were performed for the fire safety verification, and the test results were summarized in this paper.
        4,000원
        13.
        2015.04 구독 인증기관 무료, 개인회원 유료
        Compared to steel of the same weight in steel concrete structures, fiber reinforced polymer (FRP) is known to have greater strength and better resistance to corrosion. As such, it is being proposed as an effective structural material. Despite its many advantages, FRP has not been rapidly adopted in civil structures. This is because it is more expensive, prone to brittle fracture, and has weak fire resistance. To examine changes in the mechanical properties of FRP and the effectiveness of fire resistant coating, this study conducted tensile tests on coated and uncoated specimens over varying temperature. Glass fiber has excellent fire resistance since it does not melt or burn at high temperatures. However, epoxy is unable to withstand exposure to temperatures exceeding the transition temperature, thus leading to unsatisfactory structural performance and fire resistance. This study investigated the behavioral changes in FRP by exposing the specimens to temperatures ranging from room temperature (approx. 25℃) to 300℃, so as to improve the fire resistance of epoxy.
        3,000원
        14.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Structure Insulated Panel (SIP) is an wooden structure material with which structure and insulation functions are satisfied. Hence, it would be a cost-effective model to implement low energy house which has higher insulation and structure performance and which the wall thickness is able to be reduced. In this study, performance of thermal insulation and fire resistance were evaluated in order to verify applicability to low energy house. Fire resistance test is performed on vertical load bearing members for partitions, and the test results satisfy one hour of fire resistance condition according to KS F 2257. The members include two layers of fireproof gypsum board with thicknesses of 12.5mm attached to SIP. Thermal insulation performance is satisfied with the 2012 standard (0.225W/㎡·K). As the performance of resistance and thermal insulation are satisfied, SIP is expected to be applied to low energy building materials. In the future, the structural safety will be confirmed by structural performance and seismic performance test and the guidelines for distribution will be drawn up.
        4,200원
        16.
        2020.02 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 화재시 매입형 합성기둥의 높은 축력비에 따른 내화성능을 알아보기 위해 유한요소해석 프로그램(ANSYS)을 통한 해석을 실시하였다. 온도에 따른 응력-변형률 곡선을 적용하여 ASTM E 119 가열곡선과 축력비 0.7, 0.6, 0.5에 따른 과도상태 열전달해석 및 정적구조해석을 실시하였으며, 해석조건과 동일한 조건에서의 재하가열실험을 실시하였다. 또한, 기준식(Eurocode 4)에 따라 가열시간에 따 른 합성기둥의 공칭압축강도를 산정하고, 축력비로 나타내어 해석값 및 실험값과 비교하였다. 해석 및 실험과 기준(Eurocode 4)을 통해 가열시 간에 따른 단면별 온도분포를 확인하고, 이에 따른 내화성능을 측정해 비교분석하였다. 유한요소해석 결과 축력비 0.5에서는 내화시간 180분 으로 실험값과 유사한 값이 도출된 반면, 축력비 0.6, 0.7에서 내화시간 150분과 60분이 도출되어 실험결과에 비해 다소 높은 결과가 도출된 것을 알 수 있었다. 그리고 기준식(Eurocode 4)에 따라 산정한 축력비에 따른 내화시간이 실제 실험값에 비해 다소 낮게 평가하고 있다는 것을 확인하였다. 그러나 축력비 0.7에서는 기준(Eurocode 4)이 실험값에 비해 다소 높게 평가하는 것을 확인하였다. 이에 따라 고축력에서의 매입형 합성기둥의 내화특성(시간-축력비 관계)을 확인하고, 도출된 매입형 합성기둥의 실험 및 해석데이터를 Eurocode기준의 검증의 자료로 활용할 수 있을 것으로 보인다.
        17.
        2019.07 KCI 등재 서비스 종료(열람 제한)
        국내 건축법에는 표준 내화구조인 KS F 1611-5에서 1시간 내화성능을 갖는 각형강관에 대한 사양적 기준만을 제시하고 있어 각형강관에 적용되는 모듈러 건축물을 중⋅고층에 적용하기 위해서는 한계가 있다. 따라서 내화성능 평가를 통해 2시간 인정을 받은 모듈러 구조에 한하여 중⋅고층 건축물에 적용이 가능하다. 본 연구에서는 KS F 2257-1 및 KS F 2257-4 기준에 의거하여 실대형 내화실험을 수행하였다. 평가결과 OW-01 및 OW-02 실험체의 경우 각형강관의 온도상승 및 강도 저하로 인해 면외좌굴이 발생하여 2시간 내화성능을 확보하지 못하였으나, 피복 및 각형강관 두께를 보완한 IW-01 및 OW-03 실험체의 경우 충분한 차열성능으로 인해 2시간 내화성능을 확보하여 중고층 모듈러 건축에 적용하는 것이 가능한 것으로 판단되었다.
        18.
        2019.04 서비스 종료(열람 제한)
        In this study, a numerical research has been conducted to investigate the fire resistance performance of prestressed hollow-core slabs, in which the number of prestressing strands and the load ratio were set as the analysis parameters. Based on the numerical simulation results, the temperature distribution and deflection according to the fire duration time were analyzed in detail.
        19.
        2018.11 KCI 등재 서비스 종료(열람 제한)
        본 연구의 목적은 해석적 방법을 통하여 내화 재료의 특성을 파악하고 섬유 강화 폴리머로 보강된 철근콘크리트의 보의 적절한 내화설계 방법을 제안하는 것이다. 이를 위해, 내화재료의 가열실험을 실시하고 유한요소해석을 통해 열전도율과 비열을 구하고 또한 고온에서 FRP로 보강된 철근콘크리트 보 실험체에 대한 유한요소 해석을 통해 실험결과와 해석결과를 비교하였다. 이 과정에서 실험과 해석적 접근의 신뢰성을 확인하였다. 최종적으로 FRP로 보강된 철근콘크리트 보의 열적특성을 제안된 해석 방법으로 분석하고 고온으로 감소된 휨내력을 계산하였다. 최종적으로 제안된 방법을 이용하여 FRP로 보강된 부재에서 고온 노출시 열특성을 반영한 부재의 열전도를 파악하고 이를 이용하여 내력을 산정할 수 있는 것으로 나타났다.
        20.
        2018.01 KCI 등재 서비스 종료(열람 제한)
        본 연구는 하중 조건에 따른 화해를 입은 중공슬래브의 잔류성능에 대한 실험적 연구이다. 이를 평가하기 위하여, 하중조건을 변수로 하는 2개의 중공슬래브 실험체를 제작하여 ISO 834 표준화재 곡선에 따라 120분간 가열하였으며, 이를 상온으로 냉각하여 잔류 휨 성능을 평가하였다. 실험결과 하중조건에 따라 중공슬래브의 온도분포가 상이한 것으로 나타났으며, 재하 실험체가 비재하 실험체에 비해 전단면에 걸쳐 온도가 빠르게 상승하는 경향을 보임을 확인하였다. 고온으로 가열 후 냉각한 중공슬래브의 잔류 휨 강도의 경우 화해를 입지 않은 중공슬 래브에 비해 34%~40% 감소하는 것으로 나타났으며, 휨 강성의 경우 15%~23% 감소하는 것으로 나타났다. 하중을 재하 한 중공슬래브의 경우 재하하지 않고 가열한 중공슬래브에 비해 약 10%의 강도 저감이 발생하였으며, 휨 강성의 경우 15% 감소한 것으로 나타났다. 이러한 결과는 하중 재하에 따른 휨 균열에 의해 슬래브의 하부 주인장 철근의 온도가 비재하 실험체에 비해 높아지며, 하부철근 피복의 박리현상이 가속화되기 때문인 것으로 판단된다.