According to the recently revised seismic design standards, seismic design of underground structures is required. Concrete underground outer walls are installed separately from temporary earth retaining walls as permanent underground outer walls. This raises issues of constructability, economy, and space narrowness. Therefore, a steel underground continuous wall is developed to promote construction efficiency, safety, and economy by introducing the off-site construction (OSC) method of underground structures. The steel underground continuous wall will be used as a permanent underground continuous wall along with the temporary earth retaining wall. To this end, it must satisfy structural performance equivalent to or higher than the concrete underground outer wall. The integrity and in-plane shear resistance performance between single panel members must be satisfied to be used as a permanent wall. The interlocking effect through geometric bonding is intended to enhance the bonding effect between these members. Therefore, trapezoidal members were developed, and bending performance tests and analyses of each member were performed to confirm the structural bending performance of these members. The bending performance improvement effect of the combined multiple members was confirmed. As a result, it was confirmed that the integration of members and structural performance was improved due to the interlocking effect of the absence of joints. The seismic design analysis of the demonstration site was performed with these developed members, and it was confirmed that the structural performance was equivalent to or higher than that of the existing RC underground continuous wall. As a result, it was confirmed that the steel underground continuous wall can be used as a permanent underground wall together with the temporary earth retaining wall.
건축물의 대공간 및 고층화에 대한 요구가 증가함에 따라 부분매입형합성보의 연구가 진행되고 있다. 부분매입형합성보는 휨 성능을 증대시키기 위해 내부에 철근을 보강하여 시공한다. 이는 철근의 부식으로 구조물의 내력 저하를 유발한다. 이를 보완하고자 내 부식성이 우수하고 고강도인 CFRP 보강근에 대한 연구가 진행 중이다. 하지만 CFRP 보강근은 임계온도가 250℃로 낮기 때문에 적절 한 내화피복과 철근량이 필요하다. 따라서 하부철근의 종류와 SFRM 두께를 변수로 표준화재에 노출된 부분매입형합성보의 열전달 해 석을 수행하였고 화재에 의한 저감계수를 고려하여 휨내력을 산정하였다. 또한, 열전달해석과 동일한 사이즈의 실험체를 통해 비재하 수평가열로 실험을 진행하여 열전달 해석 결과와 비교 분석하였다. 해석 결과 SFRM 30 mm 적용 시 1시간의 내화성능을 확보할 수 있다. 또한, 화재 시 하중 조합에 의한 내화성능 평가 시, 무피복임에도 2시간의 내화성능을 가지는 것으로 평가되었다.
라멘 구조는 건설 분야에서 가장 널리 쓰이는 구조 형식이다. 그러나 최대 부모멘트가 발생하는 우각부에서 적절한 세부 검토 가 필요하다. 따라서 적절한 휨강도 및 휨강성을 보유한 연결구조가 필요하며, 이에 적합하지 않을 경우 우각부 볼트 배치를 회피하여야 한다. 이 연구에서는 휨강도, 휨강성 및 시공안전성 등의 구조적 성을 개선하기 위해 특수한 형식의 우각부 볼트 연결 방식을 제안하였 으며, 기존 및 제안한 볼트 연결 방식이 적용된 강재 라멘 구조에 대한 휨강도실험을 수행하였다. 실험 결과, 제안한 우각부 볼트 연결 방식은 기존 방식에 비해 휨성능이 우수한 것으로 나타났으며, 하부구조 전면에 헌치를 설치할 경우 휨성능이 더욱 증대되는 것으로 나타 났다.
Recently, the floor construction method of buildings is rapidly being replaced by the steel deck construction method of factory products from the past cast-in-place formwork method in order to shorten construction period, reduce labor costs, and improve constructability. In this study, the bending capacity of a newly developed lattice integrated rib-type deck plate that is economical and constructible was evaluated through a simple beam test. As a result of the experiment, the lattice integrated rib-type deck installed by adding rib to the existing flat deck had excellent initial rigidity and maximum load-bearing ability, confirming the feasibility of practical use. In addition, the test specimen in which the tensile rebar is not integrated with the lattice and deck has very low initial stiffness, which is insufficient to support the load at the construction stage, and new details need to be developed to overcome this.
본 논문은 염해 환경에 노출된 CFRP Grid로 보강된 콘크리트 보의 휨 거동에 대한 실험적 연구를 보고한다. 실험을 위해 길 이 2,200 mm, 폭 250 mm, 높이 125 mm의 실험체가 제작되었다. 실험변수로 염화물 수용액의 종류(NaCl: 염화나트륨, CaCl2: 염화칼 슘), 사전 하중 가력의 유무 및 염화물 용액 침지 기간(40일, 120일)이 고려되었다. 제작된 실험체는 침지 후 3점 휨 실험이 수행되었다. 초기 균열 하중은 침지 40일 후 증가하였으나, 120일 이후 다시 감소하였다. 파괴 모드는 사전 하중 가력을 통해 균열이 발생되지 않은 실험체에서는 대부분 콘크리트 압축부가 파쇄되는 휨파괴 양상을 보였으며, 사전 하중 가력을 통해 균열이 발생된 실험체는 모두 Pull-Out 파괴가 발생되었다. 염화칼슘에 침지된 실험체에서는 120일 이후 약 10%의 극한하중의 감소가 나타났으며, 염화나트륨에 침지 된 실험체의 극한하중은 미미하게 증가하였다. 균열이 발생된 실험체에서는 모두 120일 이후 극한하중 및 처짐이 급격하게 감소되었다.
The interface area of the face sheet and core of the sandwich composite is seen as a weakness due to its low de-bonding toughness. To overcome this concern, it is critical to develop a suitable modification strategy to enhance the de-bonding toughness of the face sheet/core interface. In the present study, the corrugated core reinforced sandwich composite was prepared through co-curing and secondary bonding approaches. The MWCNTs reinforced adhesive was induced in the face sheet/core interface in different weight concentrations. The MWCNT-reinforced adhesive was prepared using the sonication technique, and its dispersion was examined using atomic force microscopy (AFM). The three-point bending test revealed that sandwich composite prepared using the co-cure method has higher flexural strength than secondary bonded samples due to better bonding face sheet and corrugated core. Compared with MWCNT-free corrugated core reinforced co-cured sandwich composites (CCSC), the flexural strength of 1 wt.% MWWCNT-induced sandwich composite was increased by 101.28%. The microstructural study showed that secondary bonded samples had extensive fibre breakage at the face plate due to early de-bonding of the face sheet and corrugated core. Furthermore, the free vibrational analysis was performed to evaluate the natural frequency and damping values of the corrugated core reinforced sandwich composite. The modal test results indicated that inducing 1wt.% MWCNTs in the face sheet/core interface had enhanced the natural frequencies of co-cured sandwich composites. The present study provides a suitable method to address the weaker de-bonding toughness concerns of face sheet/core interface region of sandwich structures.
최근 프리팹 부재간 비간섭 계면이음 설계기술이 도입되고 기계주입식 충진 기술의 실용화 성공으 로, 교량 프리캐스트 바닥판 시공의 저해요인이 상당히 해결될 수 있다. 이 때 프리팹 부재에 GFRP 보강근을 적용한다면 가공조립비 절감 효과가 있고, 프리팹 부재의 경량화로 경제성이 제고될 뿐 만 아니라, 현장 안전성과 작업편의성이 향상될 것으로 보인다. 기존 철근 연신율은 20% 내외 수준인데 반해 GFRP 보강근의 파괴변형율은 3% 내외이며 탄성계수는 50GPa (강재 대비 25%수준)이므로, 이 러한 재료특성 차이로 인한 휨성능에 대한 영향 평가가 필요하다. 특히 GFRP 보강근을 프리캐스트 바닥판과 거더 간 계면이음 적용에 따른 영향을 평가하기 위한 프로토타입 거더를 설계하고, 재료간 계면의 부착 특성을 고려한 유한요소해석 모델을 수립하고 극한 휨성능과 소요 계면 전단성능과의 상 관관계를 검토하였다. 추후 본 변수해석 연구에 대해 실험적 검증이 완수된다면, GFRP 보강근 설계기 술을 정립하는 데 기여할 것으로 기대된다.
본 연구는 보강 콘크리트로 철근 대신 복합재료를 사용한 구조물의 설계에 대하여 다양한 파라미터 연구를 수행하여 철근콘크리트 대비 강점을 비교, 분석하였다. FRP 콘크리트는 ACI 440.1R-15를 적 용하였으며, 철근콘크리트 설계는 KDS 14(2021)의 최신 규정을 적용하여 다양한 파라미터 연구를 수 행하였다. 파라미터 변수로 콘크리트 밑단에서 철근의 중심까지의 거리, 보강량, FRP의 탄성계수 및 극한 변형률의 4개로 설정하여 다음과 같은 결론을 얻었다. (1) FRP의 탄성계수와 극한 변형률이 클 수록 FRP 콘크리트의 휨성능이 우수하지만, 극한 응력이 동일할 때 극한 변형률보다 탄성계수를 크게 하는 것이 유리하며, 보강량이 작을수록 유리한 것으로 분석되었다. (2) FRP 콘크리트가 인장지배 단 면이나 변화구간 일 때 극한 변형률 증가에 휨성능이 비례해서 증가하지만 압축지배 단면일 경우에는 극한 변형률이 증가해도 휨성능은 증가하지 않는다. (3) FRP 콘크리트의 휨성능은 FRP의 탄성계수와 극한 변형률을 적절하게 조절하여 선택함으로서 최적의 성능을 나타낼 수 있다. (4) 또한, FRP 콘크리 트는 최소 피복두께가 필요하지 않아 추가적인 휨성능이 17~33% 증진 효과가 나타났다.
국내 건축물에서는 노후한 철근콘크리트 구조물의 안전성이 중요한 문제로 대두되고 있다. 구조물 부분이나 전체의 무너짐으로 인해 경제적 손실을 초래할 수 있으며, 이는 주로 구성 재료의 내구성 결 함으로 인해 발생한다. 여러 노후화 인자 중 동결융해와 부식은 주요한 열화 요인으로 작용한다. 동결 지역의 구조물은 동결융해가 위험 요소로 작용할 수 있으며, 해양 구조물은 해수에 존재하는 염소이온 에 의해 부식될 수 있다. 이러한 문제를 해결하기 위해서는 복합 열화 작용과 철근콘크리트 부재의 성 능 저하 관계를 이해하는 것이 필요하다. 본 연구는 동결융해와 부식의 복합적 피해가 RC 보의 거동 에 미치는 영향을 실험적으로 조사하였다. 7개의 RC 보를 제작하여 각각 다른 수준의 열화 조건을 부여한 후 휨 시험을 실시하였다.
본 논문은 CFRP 그리드의 정착길이에 따른 콘크리트 보의 휨거동을 평가한 실험적 연구를 보고한다. 실험을 위해 폭 250 mm, 높이 125 mm, 길이 2000 mm의 실험체가 제작되었다. 실험변수로 CFRP 그리드의 정착길이(1000 mm, 800 mm, 700 mm, 600 mm, 500 mm, 400 mm, 300 mm, 200 mm)가 고려되었다. 실험체 제작 후 3점 휨실험이 수행되었다. 실험결과 모든 실 험체의 강성은 정착길이에 영향을 받지 않고 유사한 것으로 나타났다. 초기 균열하중은 모든 실험체에서 유사하게 나타났으나, 정착길이가 감소됨에 따라 최대하중, 최대하중 시의 처짐 및 변형률은 감소하는 경향을 나타냈다. 특히 부재 길이에 80% 이상 이 정착된 경우 부재 길이와 동일한 정착길이를 가진 콘크리트 보의 약 90% 이상의 구조성능을 확보할 수 있는 것으로 확인되 었다. 제안된 수치해석 모델은 CFRP 그리드의 정착길이가 감소됨에 따른 극한하중의 저하를 유사하게 예측하였으며, 극한하중 의 오차는 평균 13.1%로 CFRP 그리드의 정착길이에 따른 콘크리트 보의 휨성능을 비교적 정확하게 예측하는 것으로 나타났다.
In this research, synergetic and separate influence of nano-carbon black (C.Bn) and SiC on the microstructure and flexural strength of ZrB2 were investigated. So, ZrB2 and ZrB2- 30vol%-based composites containing 10 and 15 vol% C.Bn as well as ZrB2- 15 vol% SiC were fabricated via spark plasma sintering at 1850 °C for soaking time of 8 min under the applied pressure of 35 MPa. Relative density was measured by Archimedes method. Microstructural evaluation was carried out by applying the field emission electron microscopy (FESEM), and flexural strength was measured by three-point bending test. It was found the relative density improves in the presence of C.Bn and SiC especially in synergetic state so that the full densification was gained in Z30Si10C.Bn and Z30Si15C.Bn composites through their reactions with impurities at 1850 °C. In the monolithic ZrB2 system, the C.Bn addition improves the flexural strength slightly to 300 MPa and 315 MPa from 290 MPa. However, co-doped 10 vol% C.Bn with 30 vol% SiC resulted to achieve maximum flexural strength of 486 MPa in comparison with individually applying each of them (395 MPa for Z30Si and 300 MPa for Z10 C.Bn).
철근콘크리트는 가장 널리 사용되는 건축자재로 최근 노후 시설물이 증가하면서 노후 구조물에 대한 안전성 검토가 매우 중요한 문제로 대두되고 있다. 본 연구에서는 대표적인 열화 인자인 동결융해와 철근부식 그리고 동결융해와 철근부식의 복합적 열화에 따른 RC 휨 부재의 거동을 실험적으로 평가하였다. 4개의 철근콘크리트 휨 부재를 제작하였으며 각 열화 인자에 따른 RC 휨 부재의 거동을 평가하기 위해 4점 재하법을 이용하여 정적실험을 수행하였다. 동결융해는 총 300 사이클의 급속동 결융해실험을 수행하였으며, 부식은 전위차부식촉진실험을 수행하였다. 실험 결과, 동결융해로 인해 콘크리트의 압축강도가 12% 감소하였으며 RC 보 부재의 상부 압축부의 파쇄 범위가 증가하였고 최대강도가 6% 감소하였다. 철근부식으로 인해 RC 휨 부 재의 항복강도가 1.2%, 최대강도가 7% 감소하였으며, 복합열화로 인해 RC 휨 부재의 항복강도가 2.4%, 최대강도가 9% 감소하 였다.
본 연구에서는 GFRP(Glass Fiber Reinforced Polymer)를 주 보강근으로 사용하였으며, 정착길이가 없는 시험체를 제작 하여 4점 재하 휨시험을 수행하였다. 각 변수는 공칭지름이며 공칭지름 D13, D16, D19, 총 3가지의 변수로 이루어져있다. 휨 모 멘트는 공칭지름이 커질수록 약24.17%, 45.92% 강도가 증가하였으나 공칭 휨 강도를 고려하였을 때, 인장 강도와는 달리 공칭 지름에 비례하여 유사한 성능을 나타냄을 알 수 있었다. LVDT로 보강근과 콘크리트와의 부착성능을 확인하였고, 그 값은 매우 미미하며 거의 발생 되지 않은 것으로 판단된다. 또한 DIC로 시험체의 처짐을 확인하였으며, 실세 처짐 값과 유사함을 알 수 있었다.
철근콘크리트 구조물의 동결융해, 염해, 부식 등의 열화 현상으로 인해 구조물의 노후화가 발생되고 있다. 노후화로 인해 성능이 저하된 구조물의 성능 복원을 위해 FRP를 활용한 보수보강이 수행되고 있다. 본 논문에서는 동결융해 작용을 받은 철근콘크리트 보에 카본판재와 카본섬유로 휨 보강하여 동결융해 및 보강에 따른 철근콘크리트 보의 휨 성능을 비교 분석한 실 험적 연구 결과를 제시하였다. 이를 위해 철근콘크리트 보를 제작하여 300회의 동결융해를 수행한 후 카본판재와 카본섬유로 휨보강을 하여 성능 실험을 수행하였다. 실험 결과, 동결융해로 철근콘크리트보의 항복강도는 11% 감소하였으며, 동결융해를 입 지 않은 철근콘크리트보의 항복강도 보강성능은 20%, 동결융해를 입은 후 보강된 철근콘크리트 보의 보강성능은 19%으로 나타 났다. 에너지소산능력을 분석한 결과 본 연구에서 수행한 CFRP 보강이 동결융해로 열화된 철근콘크리트 보의 휨 보강에 유리 한 것으로 나타났다.
콘크리트 구조물은 시간이 경과함에 따라 Steel Re-bar 부식 등이 원인이 되어 주요 구조부재의 내력이 저하된다. 이 를 방지하기 위해 아연도금, 에폭시 코팅, 피복두께 증가 등의 방법이 사용되지만 근본적인 문제가 해결되지 않는다. 최근 들어 Steel Re-bar를 대체할 복합섬유에 대한 연구가 활발히 수행된다. CFRP Re-bar는 경량이며 고강도이고 내식성이 우수하다. Steel Re-bar의 임계온도는 538℃인 반면 CFRP Re-bar의 임계온도는 250℃로 화재에 취약하다. 따라서 건설현장에 적용하기 위한 내 화피복 방안이 필요하다. 본 연구에서는 콘크리트 피복두께(40, 60, 80mm), SFRM(0, 15, 30mm)두께를 변수로 CFRP Re-bar가 배 근된 표준화재 3시간 노출된 콘크리트 기둥 단면의 온도분포를 확인하고, 온도상승에 따른 소재 강도 감소를 고려하여 P-M상관 도를 도출하였다. 이를 통해 건설현장에 CFRP Re-bar를 사용하기 위한 내화피복 두께를 제안하고자 한다. 1시간 내화성능을 만 족하기 위해 콘크리트 피복두께가 60mm 필요하며, 2시간은 80mm가 필요하다. SFRM 15mm를 도포하면 400×400 단면의 경우 2 시간, 600×600과 800×800 단면의 경우 3시간 내화성능을 만족한다.
This paper investigates the effects of aspect ratio and volume fraction of hooked-end normal-strength steel fibers on the compressive and flexural properties of high-strength concrete with specified compressive strength of 60 MPa. Three types of hooked-end steel fibers with aspect ratios of 64, 67 and 80 were considered and three volume fractions of 0.25%, 0.50% and 0.75% for each steel fiber were respectively added into each high-strength concrete mixture. The test results indicated that the addition of normal-strength steel fibers is effective to improve compressive and flexural properties of high-strength concrete but fiber aspect ratio had little effect on the modulus of elasticity and compressive strength. As steel fiber content and aspect ratio increased, flexural beahvior of notched high-strength concrete beams was effectively improved.
A two-hour fire-resistance PC hollow slab for residential use was developed to secure structural and fire-resistance performance and to be applied to the general building and apartment housing markets. Compared to the existing hollow slab, in order to secure the same or better structural performance and economic feasibility by reducing the quantity, it was attempted to secure the fire resistance performance by reducing the concrete filling rate in the cross section and adjusting the thickness of the upper and lower flanges by optimizing the hollow shape in the cross section of the slab. For structural performance evaluation, experiments were performed on PC hollow slabs by varying the member thickness and the presence or absence of overlaid concrete, and all of the experimental results showed that the design strength was sufficiently exhibited and that stability during construction was possible. The developed synthetic PC hollow slab has secured fire resistance and residential performance so that it can be applied to all buildings, and it is intended to be immediately applied to the field.
PURPOSES : The purpose of this study is to experimentally analyze the flexural strength characteristics of cement mortar mixtures simultaneously incorporated with graphene oxide (GO) and polyvinyl alcohol (PVA) fibers, and to understand the composite effect of those on enhancing resistance against the initiation and progression of micro-cracks, as well as the control of macro-cracks in flexural behavior.
METHODS : Cement mortar(w/c=0.5) specimens for flexural strength test, mixing 6 mm and 12 mm PVA fibers at 1% and 2% volume ratios, were fabricated. Additionally, specimens incorporating GO at a cement weight ratio of 0.05% were prepared for each mixture to analyze the effect of GO. Therefore total eight types of mixture were prepared. The fabricated specimens were subjected to flexural strength tests after curing in waterbath for 7 and 28 days. Concurrently, digital images for analyzing deformation in accordance with loading history were obtained at a rate of 20 Hz using the DIC technique. Through displacement and strain calculation via DIC, the flexural behavior characteristics of the mixtures combined with GO and PVA fibers were precisely analyzed. Furthermore, the composite effect on flexural behavior characteristics when GO and PVA fibers are incorporated was discussed.
RESULTS : For the PVA fiber-reinforced cement mortar mixture, the incorporation of 0.05% GO increased the crack initiation load by up to 23%, and the maximum resistive load after cracking by up to 24%. Moreover, introducing GO into the PVA fiber-reinforced mixture increased the flexural strain just before cracking by approximately 30 to 50%, while the maximum resistive load after cracking exhibited similar strain levels with or without GO incorporation. Therefore, under flexural behavior, the integration of GO might delay crack initiation by increasing the strain concurrent with the rise in flexural stress before crack occurrence. It also seems to contribute to reducing crack expansion by synergistically interacting with PVA fibers after crack occurrence.
CONCLUSIONS : It was experimentally examined that the flexural strength of PVA fiber reinforced cement mortar is improved by incorporating GO. Moreover, GO enhances resistance of crack occurrance and reduces crack propagation in combination with PVA fibers. This study suggests that simultaneous incorporation of GO and PVA fibers can synergistically improve the performance of cement composites.
본 논문은 CFRP Grid를 철근 대체재로 사용하기 위해 수행된 실험적 및 해석적 연구를 보고한다. CFRP Grid가 철근 대신 적용된 콘크리트 보의 휨거동을 평가하기 위해 총 5개의 콘크리트 실험체가 제작되었다. 실험변수로 CFRP Grid의 보강 겹 수, 피복두께가 고려되었다. 3점 휨실험을 통해 모든 실험체는 휨파괴됨을 확인하였다. 특히, 2겹과 3겹의 CFRP 그리드를 갖는 실험체는 CFRP Grid의 급작스런 파단으로 파괴되었다. 초기 균열하중은 CFRP Grid 보강 겹 수가 증가할수록 증가하였다. 반면 초기균열하중에 대한 피복두께의 영향은 명확하게 나타나지 않았다. 극한하중은 CFRP Grid의 보강 겹수 및 피복두께의 영향이 명확하게 나타났다. CFRP Grid로 보강된 콘크리트 보의 휨거동을 예측하기 위한 유한요소해석 결과는 실험체들의 균열양상 및 파괴모드를 유사하게 예측하였다. 특히, 극한하중, 극한하중에 대응하는 처짐, CFRP Grid의 변형률을 매우 유사하게 예측하는 것으로 나타났다. 따라서 본 연구에서 제안된 해석모델은 CFRP Grid가 철근 대체제로 사용된 콘크리트 보의 휨거동을 예측하기 위해 효과적으로 사용될 수 있을 것으로 판단된다.