To ensure the safety and functionality of a railroad bridge, maintaining the integrity of the bridge via continuous structural health monitoring is important. However, most structural integrity monitoring methods proposed to date are based on modal responses which require the extracting process and have limited availability. In this paper, the applicability of the existing damage identification method based on free-vibration reponses to time-domain deflection shapes due to moving train load is investigated. Since the proposed method directly utilizes the time-domain responses of the structure due to the moving vehicles, the extracting process for modal responses can be avoided, and the applicability of structural health evaluation can be enhanced. The feasibility of the presented method is verified via a numerical example of a simple plate girder bridge.
In this study, by comparing the heating performance when operating the air conditioning system that is installed directly air-cooled(heater) air conditioning central air conditioning system of the ship, with improved performance, through the actual measurement study of thermal environment of the cabin, Ship's air conditioning in the future it is intended to be used as a basic data experience of design and planning.
In this study, to develop high-efficiency environmental improvement system that can be combined with hot and cold potable water supply to poultry air conditioning for the summer increase heat stress relief and winter feed efficiency through optimal design hwihan The aim of this study was to provide basic data. As a cage the size of the system installed is 100m2 test capacity 20RT district heating and cooling of air-to-water heat pump and the control was composed of electric hot water boilers. First of cage sizes for heating load design, materials, heat pump capacity, air capacity, storage tank, drinking water tank capacity, etc. were determined. The capacity of the heat pump was set to 20RT cage captive birds are erected as vertically and horizontally × height × (13 × 21 × 4.5m). Storage tank 3 tons and capacity of 10 tons potable water tank was designed. In the future, the size of the cage, designed according to the best breeding two numbers are needed.
본 연구에서는 목포해양대학교의 실습선 새누리호를 대상으로 선박의 중앙집중 공조시스템에 공랭식 에어컨을 직접 설치하여 성능을 개선시킨 공기조화시스템으로 운전하였을 경우의 냉방 성능을 비교하고, 선실의 온열환경에 대한 실측조사를 통해서 향후 선박용 공기조화 설계 및 계획에 경험적 기초참고자료로 활용하고자 하는 것이다. 연구결과 동일한 외기조건에서 기존의 중앙집중방식 공조시스템과 개선된 공조시스템으로 운전하였을 경우, 모든 선실의 온도는 24~28 ℃, 습도는 55~75 %로 쾌적한 조건임을 알 수 있었고, 발전기 부하를 측정결과 공기조화시스템의 성능개선에 따라 평균 부하 48 KW, 전부하시 부하율 약 8 %정도 감소하여 1일 연료소모량 FOC는 하루 평균 222[L/day]의 기름이 절약됨을 알 수 있었다. 또한 학생 선실(Cadet No. 21)은 기관실의 전열로 인해서 온도가 높게 나타났는데, 이것은 공기조화 설계 시 취출구 개수 및 전열부하를 고려하지 못한 결과로 판단된다.
본 연구에서는 선박의 중앙집중 공조시스템에 공랭식 에어컨(전기히터 내장형)을 직접 설치하여 성능을 개선시킨 공기조화시스템으로 운전하였을 경우의 난방 성능을 비교하고, 선실의 온열환경에 대한 실측조사를 통해서 향후 선박용 공기조화 설계 및 계획에 경험적 기초참고자료로 활용하고자 하는 것이다. 연구결과 동일한 외기조건에서 기존의 중앙집중 방식 공조시스템과 개선된 공조시스템으로 운전하였을 경우..
본 연구에서는 선박의 중앙집중 공조시스템에 공랭식 에어컨을 직접 설치하여 열원의 성능개선과 거주 구역별 독립 냉 난방이 가능한 개별분산 공조시스템을 하고자 하는 것이다. 연구 결과 기존의 중앙집중방식 공조시스템에 비해 열원 제어와 열효율상의 문제점을 보완함과 동시에 장치의 효율을 향상시킴을 확인하였다. 또한 동일한 조건에서 장치의 냉동능력과 성능계수는 평균 약 3 %, 23~26 % 정도 높게 나타났으며, Chilled Water Plants의 압축기 소비동력은 약 12 % 정도 낮게 나타났고, 동일한 조건에서 난방 시 소비동력은 약 33.5 % 낮게 나타났다. 따라서 공랭식 에어컨을 이용한 개별분산 공조시스템이 열원 제어뿐만 아니라 장치의 성능향상과 거주구역별 쾌적한 온 습도 환경 조성에 크게 기여하는 결과를 얻을 수 있었다.