검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 19

        1.
        2022.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated the maintenance and management of government office building in Dongnaebu, Gyeongsangdo in the mid-19th century. In the late Joseon Dynasty, Dongraebu was an important point of national defense and a place of trade and diplomacy with Japan, so it had many government facilities. There are very few government facilities remaining today, and no structure remains. Therefore, it is possible to grasp information about the government facilities through the old materials. Currently, there are public documents related to the local government offices such as Eupji, Eupsarye, and Junggi. Through comparison between public documents, we will examine the maintenance and management of Dongnaebu government facilities in the mid-19th century. As a result of the research, Dongnaebu government facilities were supervised by department and managed like articles. In addition, the name, size, and changes were all recorded in the management of the goods, and the authority of responsibility was clearly stated. This result is because the remaining material has the purpose of preparation as an accounting book. As a result, it was found that the government facilities in the late Joseon Dynasty were managed by a systematic department with clear authority.
        4,600원
        2.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        2008년 이후 젊은 건축가상 수상작 중 주거건축의 비율이 총 203개작에서 64개로 30%의 중요도를 가지고 있다. 따라서 본 연구의 목적은 젊은 건축가들의 단독주택의 계획방향에 관한 분석을 통해 주거건축의 실질적인 공간변화에 대해 고찰한다. 연구의 방법으로는 첫 번째, 공간구 문론 분석을 위해 기본적인 볼록공간을 설정하여 주생활 공간의 배치를 알아본다. 공간위상도에서 단위공간의 심도분석으로 각 공간의 주거공간 내부에서의 현상과 중요도를 파악한다. 두 번째, 가시영역분석을 통해 건축물의 개방도를 알아본다. 결론적으로 공간구문적 분석을 통해 주거건축에서의 내부공간의 변화된 모습과 도시내,외지역에 따라 실질적인 상황과 조건에 부 합하는 외부공간과 건축설계의 적응방법을 분석하여 향후 젊은 건축가들의 건축프로세스의 연구가 주거건축의 적극적인 사례로 변화된 계획의 방향을 알아볼 수 있을 것이고, 세부적으로는 도시주거건축과 경계부의 특성을 유추하는데 도움이 된다. 주거공간 변화를 파악하고 그에 상응하는 주거건축의 설계 방향 모색과 더불어 도시 내외부의 주거건축물 집단화에도 도움이 될 것이다.
        4,800원
        3.
        2018.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        One of engineered woods, glued laminated timber (GLT), can provide a constant level of performance and desired strength even if the quality of wood is low. Due to this fact, there is a growing interest in GLT using domestic species and related research has been carried out continuously. In addition, GLT is popularly being applied to the long-span or high-rise structures overseas. However, KBC 2016 does not allow the engineered woods to be used for middle and high-rise buildings by limiting height. Therefore, a proper design procedure and rationale should be clearly presented by the help of performance-based seismic design. With this background, the goal of this study is to establish a specific procedure for design of a 9-story building with RC shear walls and GLT frames according to the performance-based design of KBC 2016. The performance objectives were set according to KBC and the acceptance criteria for each goal were defined. The RC shear walls and GLT frames were designed by concrete and wood structure requirements, respectively. Analytical models were developed to reflect their nonlinear features, and both nonlinear static and dynamic analyses were conducted. Performance evaluation results showed that the shear walls have insufficient shear strength, so they were re-designed. Consequently, it has been confirmed that GLT frames can be applied to a 9-story office building with the assistance of RC shear walls and performance-based seismic design.
        4,000원
        4.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently, advanced metering infrastructure (AMI) has been recognized as a core technology of smart water grid, and the relevant market is growing constantly. In this study, we developed all-in-one smart water meter of the AMI system, which was installed on the test-bed to verify both effectiveness and field applicability in office building water usage. Developed 15 mm-diameter smart water meter is a magneto-resistive digital meter, and measures flow rate and water quality parameters (temperature, conductivity) simultaneously. As a result of the water usage analysis by installing six smart water meters on various purposes in office building water usage, the water usage in shower room showed the highest values as the 1,870 L/day and 26.6 liter per capita day (LPCD). But, the water usage in laboratory was irregular, depending on the many variables. From the analysis of the water usage based on day of the week, the water usage on Monday showed the highest value, and tended to decrease toward the weekend. According to the PCA results and multivariate statistical approaches, the shower room (Group 3) and 2 floor man’s restroom sink (Group 1-3) have been classified as a separate group, and the others did not show a significant difference in both water use and water quality aspects. From the analysis of water usage measured in this study, the leak or water quality accident did not occur. Consequently, all-in-one smart water meter developed in this study can measure flow rate and water quality parameters (temperature, conductivity) simultaneously with effective field applicability in office building water usage.
        4,000원
        5.
        2014.04 구독 인증기관·개인회원 무료
        요 약 급격히 증가한 세계의 에너지 소비에 따른 문제로 에너지 공급의 어려움과 자원의 고갈, 환경에 심각한 영향이 발생 하면서 국제적으로 에너지 사용량 절감에 대한 관심이 높아 지고 있다. 또한, 기후변화에 대한 대응으로 선진국에 온실 가스 감축의무가 부과되면서 에너지 절약이 사회적으로 대 두되고 있다. 도심은 건물축물 및 불투수포장면 증가로 도 시 열환경에 큰 악영향을 미치고 도시열섬현상이 발생하기 이르렀다. 도시열섬 완화를 위해 다양한 방법이 모색되고 있지만 바람길과 녹지의 확보가 가장 중요한 요소이다. 녹 지 확보가 지상을 중심으로 넓게 이루어진다면 가장 양호하 겠지만, 녹지 확보공간이 불충분한 도심지역에서는 옥상녹 화 등의 건축물 녹화가 최선의 대안으로 여겨진다. 특히 옥 상녹화는 도시환경 개선뿐 아니라, 건물에너지 절감 측면에 서도 매우 유용한 특성을 가지고 있다. 즉 옥상녹화는 옥상 에 녹지의 창출과 더불어 건물 외피의 성격으로 외단열 형 태이며, 이는 건물에너지 절감에 기여하고 있을 것으로 예 측된다. 현재까지의 옥상녹화는 주로 생태적측면의 연구와 기온저감에 대한 연구가 주를 이루고 있으며, 저에너지 건 축물 및 도시 조성 차원에서 건물에 미치는 에너지 절감효 과에 대한 연구는 매우 미흡한 실정이다. 이러한 배경에서 옥상녹화시스템에 대한 열성능 시뮬레이션의 필요성과 대 략적 방법론이 제시되어 에너지저감효과에 대한 분석이 이 루어 졌으나, 대부분 토양과 식재만을 고려하여 분석하였다 는 제한점이 있다. 또한 대도심 건축물의 주를 이루고 있는 오피스건물에서 옥상녹화 유·무에 따른 건물에너지절감에 대한 연구는 부족한 실정이다. 따라서 본 연구는 도심지에 서 가장 많이 이용되고 있는 오피스 건물을 대상으로 옥상 녹화시스템이 건물에너지절감에 미치는 영향 및 비교·분석 을 통해 향후 대도시 지역의 건물에너지 절감을 실현할 수 있는 옥상녹화시스템 개발의 기초자료로 제공하고자 한다. 본 연구의 시뮬레이션 프로그램은 EnergyPlus7.2를 이용 하였다. EnergyPlus는 미국 DOE(Department Of Energy) 에서 개발된 프로그램으로 에너지사용량 평가에 유용한 툴 로서 국내외에서 타당성이 검증된 시뮬레이션 프로그램이 다. EnergyPlus는 기존 해석 도구인 DOE-2, BLAST, COM IS의 장점을 통하여 개발된 도구로서 CTF(Condcuction Tr ansfer Function)과 CFD(Conduction Finite Difference), H AMT(Combined Heat and Moisture Transfer) 등과 같은 벽체 열전달 계산 알고리즘을 이용하여 기존 해석 도구에서 불완전했던 실내 온도 예측과 같은 점이 보완되었다. Energ yPlus는 상세 에너지 해석이 가능하며 해석기간 동안 수시 로 변화하는 건물의 실내외 조건, 벽체의 축열부하를 고려 하여 매 시간당 에너지균형(Energy Balance)을 계산하기 위해 유한차분법, 응답계수법 등과 같은 수치해석 방법을 채택하고 있다. 일정 시간 간격으로 외벽을 통한 관류열, 시간에 따른 실내 현열 및 잠열, 발열, 환기 및 침기에 의한 열손실/취득, 일사, 천공복사, 내벽체간 복사, 주위건물 음 영, 건물 내·외부 대류 열전달 등, 여러 가지 열전달 경로를 통하여 동시에 발생되는 열부하를 통합하여 계산한다. 적용 모델의 건물은 3층 규모로 설정하였으며 연면적 1,200㎡, 창면적 210㎡ 이며, 옥상녹화유형별 에너지절감효과를 정 량적으로 분석하기 위해 식재층 재료, 토양층 재료, 배수판 재료, 단열재 적용 유무 등을 고려하여 5개 type으로 설정하 였으며, 이외 옥상녹화가 미적용된 type을 포함하여 총 6개 type의 시뮬레이션을 실시하여 미적용 대비 옥상녹화의 에 너지절감효과 및 옥상녹화시스템별 에너지절감 차이를 정 량적으로 제시하였다. 옥상녹화시스템 유형은 저관리경량 형으로 type B, C, D, E를, 관리중량형으로 type F를 설정하 였다. 시뮬레이션에 적용된 type별 구조를 구체적으로 제시 하면, 옥상녹화가 미적용된 type A는 콘크리트 210㎜, 단열 재 110㎜이고, 이외 5개 type에서도 건물구조는 type A와 동일하게 설정하였다. type B 구조는 식재층(100㎜)+GBblock(100㎜)+방근시트(2㎜)+배수판(50㎜), type C 구조는 식재층(100㎜)+펄라이트(70㎜)+부직포(2㎜)+화산석(80㎜)+sedemblock(80㎜), type D 구조는 식재층(100㎜)+펄 라이트(115㎜)+부직포(2㎜)+배수판(35㎜), type E 구조는 식재층(100㎜)+마사토(85㎜)+펄라이트(30㎜)+부직포(2 ㎜)+배수판(35㎜), type F 구조는 식재층(100㎜)+마사토(3 00㎜)+펄라이트(30㎜)+부직포(2㎜)+배수판(35㎜)으로 구 성하였다. 적용건물의 설정조건으로는 냉·난방 설정 온도 각각 22℃, 24℃, 공조방식은 Fan-coil unit 방식을 적용하 였다. 또한 난방기(Heat Generation)와 냉방기(Chiller)의 성능 계수는 각각 0.83, 1.67로 설정하여 분석하였다. 조명 설계는 사무공간으로 목표조도 400lux, 조명부하 5 W/㎡·1 00lux이며, 창면적비율은 30%, 재실인원 0.11 people/㎡, 인체발열 123 W/person, 환기량 10 l/s·person, 급탕 0.2 l/ ㎡·day, 건물운용 24시간(근무시간 9:00~18:00)으로 설정 하였으며, 기상데이터는 중부지역의 충주지역의 기상데이 터를 이용하여 분석을 수행하였다. 옥상녹화 면의 열관류율(U-Value)은 type A 0.332 W/ ㎡·K, type B 0.25 W/㎡·K, type C 0.281 W/㎡·K, type D 0.287 W/㎡·K, type E 0.284 W/㎡·K, type F 0.271 W/ ㎡·K로 분석되었다. 열저항성(R-Value)은 type B > type F > type C > type E > type D > type A 순으로 나타났다. 건물부하는 시시각각 변화하지만 이것이 최대가 되는 시각 에 대해서만 열량을 계산하며, 이것을 최대부하시간(Peak Hour)에 대하여 행한 부하계산을 최대부하계산법(Peak Lo ad Design)이라 한다. 피크부하 중 난방피크부하량은 type A > type D > type E > type C > type F > type B 순이며, 미적용 유형인 type A 대비 type B, C, D, E, F 유형은 약 0.6 ~ 0.9% 절감효과가 예측되었다. 또한, 냉방피크부하 량은 type A > type E > type D > type C > type B > type F 순이며, type A 대비 type B, C, D, E, F 유형은 약 1.1 ~ 1.2% 절감효과가 예상되었다. 연간냉·난방부하량 은 type A > type E > type D > type C > type B > type F 순이며, type A 대비 type B, C, D, E, F 유형은 약 1.14 ~ 1.18% 절감효과가 예측되었다. 연간에너지사용량은 type A > type D > type E > type C > type F > type B 순이며, type A 대비 type B, C, D, E, F 유형은 약 0.5 ~ 0.9% 절감효과를 보였다. 최상층의 에너지성능분석을 한 결과, 난방피크부하량은 type A > type D > type E > type C > type F > type B 순이며, 미적용 유형인 type A 대비 type B, C, D, E, F 유형은 약 1.3 ~ 2.1% 절감효과가 예측 되었다. 또한, 냉방피크부하량은 type A > type E > type D > type C > type B > type F 순이며, type A 대비 type B, C, D, E, F 유형은 약 1.2 ~ 1.5% 절감효과가 예상되었 다. 연간피크난방부하량은 type A > type D > type E > type C > type F > type B 순이며, 미적용 유형인 type A 대비 type B, C, D, E, F 유형은 약 6.0 ~ 9.0% 절감율을 보였으며, 연간피크냉방부하량은 type B > type A > type F > type C > type E > type D 순이다. type B를 제외한 유형에서는 냉방부하저감을 보였으나, type B는 다른 유형 에 비해 높은 단열성으로 인해 내부의 열이 외부로 방출되 지 못한 결과로 사료된다. 이상의 결과로 옥상녹화 적용에 따른 에너지저감효과는 냉방시기 보다 난방시기에 높은 효과를 보였으며, 향후 다 양한 옥상녹화시스템 및 유형별 조성에 따른 검토가 이루어 져야 할 것이다.
        7.
        2012.09 구독 인증기관 무료, 개인회원 유료
        Environmental problems such as global warming become social issues today. It is reported that increasing energy consumption has affected on these environmental issues. Buildings deploys 40 percent of the raw materials in the world while at the same time they emit over 35 percent of the total CO2, so that it utilize over 50 percent of the whole energy in the world. At this point, energy saving though effective building control may eventually bring social, environmental and economical effects. Thus, this study will explore the difference between measured temperature and monitored temperature for operating air control system in the building, to which BEMS is applied. Also, it will suggest a method to accurately predict the load of air-conditioning, and will examine the different amounts of the load according to the temperature as well as the reduced amount of the load through changes of operation standard temperature.
        4,000원
        8.
        2012.03 구독 인증기관 무료, 개인회원 유료
        Recent projects for transferring Public Office buildings and estimation of appropriate construction expense are highly important for both government and construction firms. Moreover, estimation and management of construction expense can be regarded as extremely important duties for effective execution of a national budget as nation’s finance is invested in the Public office building projects progressed by the government. To progress one project for Public office building, not only the organization demanding the project but also an investment screening organization, a budget-managing organization, a feasibility assessment institution and many other related organizations participate in the project and a lot of decisions arisen from the project operation are made on the basis of construction expenses calculated for relevant stages. And estimation of rational construction expense is also critical for designers in order to create design within the fixed budget simultaneously with securing the quality and efficiency of structures to the maximum. Therefore this research suggested an improvement process to analyze problems in current construction expense management process and to administer the construction expenses effectively.
        4,000원
        9.
        2011.03 구독 인증기관 무료, 개인회원 유료
        The paper mainly discusses on the method how to save energy so as to follow the "Low Carbon and Green Growth" by the govemment and the Building Energy Efficiency Rating System. For the purpose of interior comfort as well as effective operation and management of buildings, this paper does basic research on development of elementary technology for saving the energy used in building. In this paper, the interior lighting control zone is selected to make a lighting control algorithm which takes the reduction of building energy into consideration for saving building energy when the building envelopes are replaced by the BIPV system.
        4,000원
        10.
        2009.09 구독 인증기관 무료, 개인회원 유료
        A prediction of construction cost in preparation for construction document is calculated in compliance with the unit cost in Public construction of korea. This eventually means that the reasonable construction cost of a building can't be determined before construction document phase cost of construction is settled and that the cost of construction is calculated inefficiently because of connection failing between cost management of detailed estimation and information. To improve those problems, therefore, Cost estimating model of structural building elements with approximate quantity survey method is suggested in this research. The model predict the amount of materials and the cost of construction on the basis of historical similar cases. In the direction of data analysis of this research, ratio statistics value is put to practical use to fit into the peculiarities of approximate estimate of each work trade on the basis of actual data amount of materials of historical cases. In addition, the construction phase is connected through the result of a approximate estimate sorted by elements, details work trade.
        4,000원
        11.
        2009.03 구독 인증기관 무료, 개인회원 유료
        When managers predict exact construction cost at early stage and design phase, they can reduce construction cost in a more efficient way than to predict at construction stage. But present of public construction cost estimation and management almost after the construction documents design phase. Therefore, construction cost management in the early stage and schematic design phase to generally use approximate estimating is not correct. Accordingly, this study analyze problem of current cost estimating method and a concrete cost plans make using case information of actual cost to analyze in schematic design phase. Possible to check going on the suitable design, this study conducts the preliminary research for the development of cost estimating model.
        3,000원
        13.
        2004.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is to analyze the building layout of traditional government office building in Chungchong province with Chungchong-do regional maps and Eupjis(邑誌) being compiled in the late Chosun dynasty. The building layout of government office in Chungchong-do is followed in the wake of the spatial structure, Sam-Jo(三朝, three reign) and Oejeon-Naejeon(外殿-內殿), of Chosun dynasty palace. The planning principle of Sam-Jo at government office, Dongheon(東軒) territory for rule administration corresponds to Chijo(治朝) with a local governor who is the ruler, as for the Naea(內衙) territory which a family of him and he lives in, it is corresponded to Yeonjo(燕朝), and in the job space of Ajeon(衙前), it is corresponded to Oejo(外朝). As for the application of the inside and outside principle of provincial government office, Dongheon is corresponded to Oejeon and Naea to Naejeon. A compositive and an approach axis of government office in Chungchong-do is correspond with Dongheon in the center, and these axes form an central axis and an entry space of government office included Oesammun(外三門) Naesammun(內三門) Dongheon or Naea. Because an essential performance of provincial government office is provincial administration, the layout configuration of government office is a function, which is an expression of an official institution.
        4,500원
        14.
        2001.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this research is to study suitability of a sweeper as a new occupation fitting to the character of the people with the mental retardation. Analysis of job which is necessary to perform the sweeper has been conducted. This research also studied the suitability of the occupation to the individuals with different impairments of physical, sensory function, cognitive function and emotional behavior based on the study of 5 individual participants. Conclusion is as follows. 1. The office building maintenance(sweeper) is an occupation which demands muscular strength of gross motor. Visual perception about a space and an object is mainly needed and the most important facts in the cognitive function are an idea of time, sequence, direction, topographic orientation, & memory. 2. Based on analysis of 5 different individuals who have different functional impairments shows that deteriorated muscular strength (compare to non-disabled person) didn’t affect the job. On the contrary, visual perception and emotional behavior problems are two biggest challenges to the occupation. 3. Not requiring dexterity of hands movement as in the manufacturing industry and broad acting radius, those two facts made a sweeper a suitable occupation for the people with mental retardation who lack dexterity in acting and concentration. Based on the research, a sweeper is a suitable occupation fitting to the character of the people with mental retarcation and it is therefore need to generalize the result of the research by conducting a follow-up research with more participants.
        5,100원
        15.
        2000.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        펌프는 다르 진동 유발원들과는 달리 일정한 주파수 및 크기를 갖는 진동을 일으키므로 스프링이나 댐퍼와 같은 간단한 방진기기를 이용하여 진동을 제어할 수 있다 현재 국내에서는 대부분의 펌프에 이러한 방진장치를 설치하는 것이 일반화되어있다 그러나 펌프의 용량 및 중량 주변 구조물의 형태 및 크기 등에 따라서 방진기구의 채택이 불필요한 경우도 있으므로 설비 진동기초에 대한 획일적인 설계와 시공개념은 불필요한 인적, 시간적 및 경제적인 낭비를 초래할 수 있다. 따라서 본 연구에서는 사무용 건무에 사용되는 각종 펌프류에 대하여 가진특성과 구조물의 진동가속도응답을 측정하는 진동실험 및 이론적 해석을 실시하고 본래 계와 수정된 계의 진동을 답과 허용진동수준을 비교.분석함으로서 방진장치의 설치가 불필요한 펌프용량을 제시하였다.
        4,300원
        16.
        1999.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aims to infer the plan and location of the government office building in Chongju Castle in the Late Yi-dynasty. The conclusion is as follows: 1. The Chongju Castle Map(淸州邑城圖, late in the 18th century, hereinafter referred to CCM) provides the detail arrangement and location of Government Office Building in Chongju Castle. And the road structure and plan of the CCM is almost same with the present time. 2. As compared with CCM and a Chongju-land Registration Map(淸州面地籍原圖, 1913, CRM) to infer the location of the traditional government office building in Chongju Castle, the building locations of Gaek-Sa(客舍) Donghun(東軒)'s region in CCM are almost accordance with today's. But those of Byungyoung(兵營) Group's region are represented by a little error. So the locations of Byungyoung(兵營) Group's region rearranged, moved down to be in accordance with the approach circulation of Main Gate(閉門樓) which is shown in CRM. 3. The records, on the plan of the traditional government office building in Chongju Castle, have proved that the plan of Gaek-Sa was a width of 11 bay and a depth of 2 bay. A width of 3 bay drawn in CCM, the present plan of Donghun is a width of 7 bay and a depth of 4 bay. The main building and especially the double-storied Main Gate($4{\times}3$ 수식 이미지) of Byungyoung Group are exactly in keeping with the present road structure.
        4,300원
        18.
        2014.08 KCI 등재 서비스 종료(열람 제한)
        This study, the urban energy used office building green roof type composition of the target by analyze building energy reductions. Green roof is total 6 types(type A~F) were selected, EnergyPlus the energy simulation programs were used. Top floor of green roof types evaluation, the reduction of the cooling peak load type E(1.26%), type D(1.30%), type C(1.37%), type B(1.45%), type F(1.49%), and heating peak load is type D(1.32%), type E(1.40%), type C(1.47%), type F(1.69%), type B(2.13%) order. Annual cooling load of heating load is reduced more than about 1% effect. The heating load reduction ratio for a maximum of 9% respectively. Cooling peak load of the building energy performance evaluation of type F >type B >type C >type D >type E in the order and in the case of peak loads heating type B >type F >type D >type E >type C order. Annual total energy use reduction of 1.07 to 1.22% and earn, type B in the best good. In primary energy use reductions in the presence of a green roof were in the 4249~4876 kWh/yr. Annual CO2 emissions reductions of unapplied type A were analyzed on average 469.78 kg.
        19.
        2012.02 KCI 등재 서비스 종료(열람 제한)
        옥상녹화는 부족한 도심내에 녹지를 제공해줌은 물론 현대인들에게 휴식공간을 제공해줄 수 있는 장소로 창출되어 질 수 있다. 본 연구는 오피스 건물의 옥상녹화 도입시, 효율적인 이용방안을 위한 구체적인 조성기법을 제안하고자 하였다. 따라서 옥상녹화가 조성된 오피스 건물 중 4곳을 선정하여 이용자들의 선호도 및 만족도를 조사ㆍ분석하였으며 효율적인 이용활성화를 위한 측면에서 다음과 같은 조성방안을 도출하였다. 이용자 선호도 조사결과, 식재식물에 있어 꽃, 열매, 잎 등의 관상가치가 높은 관목 중심 공간에 대한 선호도가 높았으며 녹지와 휴식공간이 절충되어져 있는 정원형의 선호도가 높은 것으로 조사되어 휴식・녹지공간이 유기적으로 결합된 조성형태가 바람직한 것으로 판단되었다. 바닥포장재에 대한 선호도를 보면 식생을 포함한 바닥소재, 지압보도에 대해 높은 응답률을 보였으며 이는 녹지면적과 운동, 휴게 등의 이용면적의 기능을 동시에 충족시킬 수 있는 다기능적 조성방안의 중요성을 제시할 수 있겠다. 이용자 만족도 조사결과, 각 대상지별로 풍부한 녹지량을 선호하지만 꽃, 열매, 잎 등의 관상가치가 높은 키 작은 관목 중심 공간에 대한 만족도가 높은 것으로 나타났다. 또한, 옥상녹화 이용도를 높이기 위하여 벤치, 자판기, 수경시설, 운동시설 등의 휴게・여가・경관감상・운동 등 다양한 욕구를 충족시킬 수 있는 복합적 기능의 녹색공간 조성을 원하는 것으로 조사되었다. 과밀화된 도심에서 옥상녹화는 생태적, 환경적 측면에서 매우 중요한 역할을 수행하고 있다. 그러나 인간의 이용적인 측면을 고려하지 않고 단순한 피복 중심의 녹지 차원에서의 조성에는 한계가 있다. 녹지가 가지는 생태적, 환경적 측면의 효과뿐만 아니라 인간에게 주는 긍정적인 기능과 효과에 대한 이해를 통하여 보다 다양한 측면에서의 옥상녹화 조성에 대한 접근이 필요하다. 이에 본 연구는 오피스 건물의 옥상녹화 활성화를 위해 이용자들의 선호경향을 파악하였으며 이를 토대로 오피스 건물의 효과적인 옥상녹화 및 적극적 이용을 동시에 도모할 수 있는 방안마련을 위한 기초자료로 활용될 수 있을 것이다. 향후, 본 논문의 조사자료를 바탕으로 다양한 건물의 특성에 적합한 녹화구성요소, 이용자들의 요구사항에 부합된 프로그램을 적용, 다기능적 검증이 이루어질 수 있는 구체적인 후속연구가 이루어져야 할 것이다.