검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 5

        1.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the grid field olfactory odor method was supplemented to the domestic situation in the surrounding areas of a domestic science industrial complex. The actual condition of the occurrence of odor frequency in the field was then investigated over the first period of late spring to summer and the second period of autumn in 2017. The frequency of odor occurrence in the area around the science industrial complex was increased as odor discharge facilities in the nearby area were concentrated. The odor occurrence frequency of the total period was 0.09~0.28, that of the first period was 0.08~0.32, and that of the second period was 0.05~0.25. The odor occurrence frequency in summer was higher than in autumn. The frequency by which the measurement of odor occurrence by smell type was most dominant was mainly smell of chemicals, plastics, and livestock houses during the first period, and the smell of chemicals, burning gases, and plastics during the second period. And the frequency of each smell type was judged to be different according to season. The odor occurrence frequency was measured as higher than 0.15, which is the standard of Germany's odor frequency in an industrial area, and it was judged that measures for odor management in the region were necessary. Since most of the odor discharge facilities are non-continuous systems and the odor generation frequency is more important than the concentration of the minimum detection concentration, it was judged that the German grid method can reflect the odor occurrence characteristics of the odor complaints or receptors for a certain period of time compared to the domestic measurement method. In the future, it was judged that the field olfactory odor method would be able to replace the evaluation method of odor assessment in Korea with the survey method of odor assessment under actual conditions in areas where it is difficult to access the odor discharge source or the receptor where odor complaints occur.
        4,000원
        2.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we conducted a survey on odor characteristics of single odor and collective odor facilities using the German olfactory odor method and carried out the odor frequency modeling. The influence of the odor from a sewage treatment plant, which is a single discharge facility, was strong in the eastern and northern parts of the plant and appeared to be in good agreement with the areas where the odor complaints were frequent. The German olfactory method reflects the odor complaints and odor occurrence characteristics of the receptors as compared with the domestic odor measurement method. The influence of the odor from the odor control area, which is a collecting and discharging facility, showed a tendency in which the sum of the odor occurrence frequency increased with the proximity of the odor discharge facility to the dense industrial complex. Furthermore, it was judged that it is not easy to extract the odor frequency results for individual facilities because the survey subject is the group discharge facility area. Therefore, it will be necessary to introduce a method to manage odor in the future. In this study, the measurement of odor frequency using the German olfactory odor method is partially applied to some odor sources. Appropriately, it is not applicable to various emission sources. However, the odor measurement method based on odor occurrence frequency and odor sensory can be used for investigation of the actual condition, permits of odor discharge facilities and the environmental review.
        4,300원
        3.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        2011년에 전국 79개 악취검사기관을 대상으로 공기희석관능법에 대한 숙련도 시험을 실시하였다. 악취방지법의 부지 경계선과 악취 배출원의 배출허용기준을 모사한 2개의 합성복합악취를 숙련도 시험물질(proficiency testing materials, PTM)로 사용 하였다. 부지 경계선 시료는 7ppm의 톨루엔과 7ppm m-자일렌의 복합악취로 구성하였으며, 배출구 시 료는 10ppm DMS (dimethyl sulfide)와 10ppm DMDS (dimethyl disulfide)의 복합악취로 구성하였다. 숙련도 시험 결과는 기준값으로 평균과 중간값을 사용하고, 목표표준편차로 일반 표준편차, 로버스트 표준편차 및 변동계수를 사용하여 Z-점수를 평가하였다. 시험결 과의 변동계수는 PTMs의 냄새강도가 증가함에 따라 감소하였다. 복합악취에 대한 숙련 도 시험 결과는 악취희석배율보다 로그 스케일의 악취지수를 사용하여 평가하는 것이 적 절했다. 두 PTMs에 대한 참여기관의 Z-점수를 변동계수, 표준편차, 그리고 로버스트 표 준편차를 사용하여 평가할 때, 참여기관의 95%가 숙련도 기준을 만족하였다. 목표 표준 편차를 변동계수의 20%로 설정하였을 때 참여기관의 만족도 비율은 부지경계와 출구 PTM 시료에 대해 각각 90%와 95%로 양호하였다. 이러한 결과들로부터 부지경계와 출 구의 복합악취를 모사한 두 합성 PTMs 모두 복합악취의 숙련도 시험물질로 적합하였다.
        4,000원
        4.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, odors in N industrial complex in Incheon city were measured by using air dilution olfactory method, odor sensor and instrumental analysis method. Three industry categories which are plating industry, equipment manufacturing industry and petrochemical manufacturing industry were classified and the correlation of data was evaluated based on the measurement result. The correlation coefficient between the air dilution olfactory method and the odor sensor device utilizing method in 69 points was 0.562. The correlation coefficients in the classified industry categories were observed 0.889 in the plating industry, 0.723 in the equipment manufacturing industry and 0.832 in the petrochemicals manufacturing industry. It shows that when the correlation coefficient is over 0.75, they have a strong correlation. In this result, we could identify the ease of availability of the correlation using industry classification.
        4,000원
        5.
        2012.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Since 2011, proficiency test for the air dilution olfactory method started in Korea for the evaluation of the authorized odor inspection agencies’ analysis skill. For this purpose, sulfur compounds of PTMs (proficiency test materials) were made and investigated for the application to the proficiency test as a complex malodor sample. Time stability and homogeneity between samples were analysed for the PTM which was made with 10 ppm of DMS and 10 ppm of DMDS. As the results, the stability of sample concentration with GC analysis was shown around 6%RSD through the time of 6~48 hr. In addition, dilution number during the same test period appeared almost stable, less than 6%RSD in air dilution olfactory method. The reproducibility results of four laboratories showed very similar results except one lab which was caused by the elder panel characteristics.
        4,000원