간행물

실내환경 및 냄새 학회지 KCI 등재 Journal of Odor and Indoor Environment

권호리스트/논문검색
이 간행물 논문 검색

권호

제17권 제3호 (2018년 9월) 12

연구논문

1.
2018.09 구독 인증기관 무료, 개인회원 유료
This study investigates the indoor air quality conditions of the total of 52 buses depend on seasons, time and others. We evaluated the CO₂and PM10, the controlled parameters in express buses by Ministry of Environment and VOCs and HCHO, the non-controlled parameters. The CO₂concentration during peak commute times was 38.5% in summer and 15.4% in autumn, which are higher than the normal. But, PM10 concentration was influenced by the outside air not number of passengers. The concentration of VOCs were not related with other parameters such as number of passengers, seasons, and driving time. And then, the formaldehyde concentration was not related with seasons as it showed little difference between summer and autumn.
4,000원
2.
2018.09 구독 인증기관 무료, 개인회원 유료
In this study, we measured the concentration of Particulate Matter (PM10), Formaldehyde (HCHO), and Total Bacteria Count (TBC) at three facilities: elderly care centers, day care centers, and postnatal care centers located in the cities of Seoul, Sejong, Daegu and Ulsan from January 1, 2012 to December 31, 2015. PM10 concentration was the highest in the day care centers and HCHO concentration was the highest in the postnatal care centers. TBC concentration was the highest in the day care centers. Comparing the different cities, PM10 concentration was the highest in Sejong, HCHO concentration was the highest in Seoul, and TBC concentration was the highest in Daegu. This study is expected to be helpful in preventing damage to health from the contaminated indoor air at sensitive facilities, and can be used as basic data for indoor air quality management.
4,000원
3.
2018.09 구독 인증기관 무료, 개인회원 유료
A lab-scale biofilter with fungal growth has been studied to investigate the removal of gas-phase hydrogen sulfide. The biofilter inoculated initially with the aerobic activated sludge was operated for 100 days under acidic condition, and 0.36 L/d of the buffered nutrient with 0.05 g/L Chloramphenicol and Gentamicin was injected into the biofilter. The critical removal capacity of hydrogen sulfide was up to 22 g/m³/h. The pH of the effluent liquid was stable at pH 1.5-2, corresponding to the volatile suspended solids of 20-50 mg/L. In microbial analysis through the plate count method, it was found that fungi were dominant over bacteria. The fungi isolated from biomass in the bilfilter were identified as Acidomyces acidophilus and Aspergillus fumigatus. Sulfate and thiosulfate were also detected in liquid samples, as a result of the biological sulfur oxidation in the biofilter bed. For the analysis of sulfur mass balance, the accumulated mass of sulfate and thiosulfate reached up to 67.5% of inlet sulfur. Sulfur was also detected on the biomass collected from the biofilter through Scanning electron microscopy/Energy dispersive X-ray spectroscopy.
4,000원
4.
2018.09 구독 인증기관 무료, 개인회원 유료
This study aims to evaluate thermal performance using the ASTR method. Its findings are as follows: 1) The measured U-Values of 49A type and 59A type walls were almost the same as the theoretically calculated values. 2) One notable phenomenon for both walls was that the interior surface temperatures of the channels attached to corners were up to 10.4% lower than that of the cross of the wall, even though they consisted of the same materials. This is due to the surface temperature drop caused by the thermal bridge. 3) The surface temperatures of the thermal bridge were converted into U-Values. The U-Value of the top left corner on the 59A type house was 1.044W/m²K, and of the bottom right corner on the 49A type house was 0.959W/m²K. Therefore, the thermal performance of the thermal bridge area was decreased after construction. 4) Differences were found in the results of comparing heat transfer analysis simulation data and measured data. A maximum difference of 12.4% occurred in the top left corner on 59A type, and of 7.6% occurred in the bottom right corner on 49A type. 5) The results of a heat transfer analysis simulation showed that the temperature of both 49A type and 59A type top right corner were the lowest, but in-situ measurement results were the lowest in the bottom right corner on 49A type and in the top left corner on 59A type. These results are considered to be due to the occurrence of thermal bridges and a deterioration in the construction quality.
4,000원
5.
2018.09 구독 인증기관 무료, 개인회원 유료
Cement production processes release various odor elements including acetaldehyde, hydrogen sulfide, formaldehyde and toluene etc. A three-dimensional numerical simulation using a commercial code of Computational Fluid Dynamics (CFD) was used to estimate the concentration profiles and dispersion distance around the local residential area. The calcination furnace, one of the main emission sources in the cement manufacturing process, discharged the odorous gases of H₂S, HCHO, CH₃CHO and C6H5CH₃at levels of up to 3.15 ppb, 5.1 ppm, 6.65 ppm and 0.74 ppm of H₂S, HCHO, CH₃CHO and C6H5CH₃respectively. This study found that as for the emission concentration of 1ppm for H₂S and CH₃CHO, the landing distance of the threshold value for each gas was extended in summer seasons at a low velocity. Low temperature of the flue gas at a high velocity also led to long dispersion.
4,000원
6.
2018.09 구독 인증기관 무료, 개인회원 유료
In this study, the odor generated in a livestock farm with 500 heads of finisher breed in 661 m² was monitored during 6 months using a gas sensor, a wired / wireless communication system and database server. Odor unit, ammonia, hydrogen sulfide, and total volatile organic compounds (TVOC) were monitored using the gas sensor. To show the tendency of odorous substances generation, the odor concentration was shown in the graph on a monthly and daily basis. Among the analysis items, the maximum generation of odor was found to be closely related to the generation of hydrogen sulfide. Through observing the daily and monthly trends of odor substances, it was found that each substance was a useful indicator for monitoring odor, because ammonia, hydrogen sulfide, odor and TVOC were increased and decreased in a similar pattern. The odors were highest in the hours of the early morning (00:00-05:00), the evening (18:00-23:00), and the morning (06:00-11:00) in a day. After the use of the microbial agent was discontinued in autumn (October), anaerobic digestion of the manure in a pit proceeded and the amount of hydrogen sulfide increased. Therefore, despite a slight decrease in ammonia production, the odor unit level did not decrease after October but rather was somewhat increased. In the future, the use of the odor monitoring system is expected to improve the efficiency of odor sources management.
4,000원
7.
2018.09 구독 인증기관 무료, 개인회원 유료
The annoyance potential for odor sources can be evaluated by separation distances. A separation distance between a standard pig farm and a residential area was investigated by the AERMOD model. The studied area comprised four sites in Korea. The study sites were Paju, Yangpyeong, Suwon, and Icheon, respectively. The separation distances criteria of the three reference Odor Impact Criteria (OIC) were used to evaluate the separation distance. Results show that separation distances for the four sites were calculated 20 m from the fence in the existing pig farm criteria case [exceedance probability P (%) = 2.0% and concentration = 6 OU] in Ireland. In the case of the new pig farm criteria [(exceedance probability P (%) = 2.0% and concentration = 3 OU) of Ireland, results show that the separation distances of the four locations were between 120 m and 145 m from the fence. These values were about 3.0~4.5 times larger than those of the existing pig farm criteria case. In the case of a concentration of 1 OU and the exceedance probability P (%) of a 2.0% criteria, the separation distances of the four sites ranged from 250 m to 290 m.
4,000원
8.
2018.09 구독 인증기관 무료, 개인회원 유료
Environmental treatment residues become valuable waste byproducts like biomass when an environmental infrastructure necessary for recycling is effectively developed. In this study, an environmentally friendly sewage sludge sorbent was developed in a sewage treatment plant by carefully processing the sewage sludge generated from sewage treatment plants. In order to increase the adsorption efficiency, coffee ground waste was added to the adsorbent as an additive and the adsorbate used in the adsorption experiments was acetaldehyde as organic waste. It could be found from the experiment that the adsorbent of the sewage sludge was adsorbed more easily at the carbonization temperature of 600℃. In addition, adsorption experiments showed that the breakthrough time reached to 85, 110, and 130 minutes at 3:1, 2:2, and 1:3, respectively, depending on the content ratio of the sewage sludge and coffee waste. Therefore, the amount of acetaldehyde adsorption increased with the increase in the amount of coffee grounds in the mixture. It could be also be found that the addition of the coffee grounds as an additive to increase the adsorption capacity of the sewage sludge adsorbent is advantageous for adsorption.
4,000원
9.
2018.09 구독 인증기관 무료, 개인회원 유료
본 연구에서는 현행 악취공정시험방법에 나타나있는 공기희석 관능법을 사용하여 물질농도와 희석배수와의 관계를 살펴보기 위해 프로피온산, 뷰틸산, 발레르산, i-발레르산 및 i-뷰틸알코올에 대한 물질농도와 희석배수를 측정하였다. 또한 상관관계식을 이용하여 지정악취물질의 농도 규제치의 적정성을 검토하였다. 1. 판정인에 의해 측정된 대상물질의 물질농도와 희석배수의 상관관계는 식 Log C = Af·Log D + 0.5에 의해 적절하게 나타났으며, 총 22종의 지정 악취물질별 상관관계식의 기울기 값의 범위는 0.9023~1.2012으로 이소발레르알데하이드가 가장 작고, 뷰틸알데하이드가 가장 큰 것으로 나타났다. 2. 물질별 관계식으로부터 산출된 희석배수 15와 20에 해당되는 물질농도와 최소감지농도와의 비를 구한 결과, 각 물질의 농도비가 희석배수 15 및 20과 유사한 수치를 나타내 물질별 관계식이 의미가 있는 것으로 추정되었다. 3. 물질별 관계식으로부터 산출된 희석배수 15와 20에 해당되는 물질농도와 현행 물질농도 기준치와 의 비교를 통하여 기준치의 적정 수준 여부를 검토 해본 결과, 프로피온산과 뷰틸산의 경우는 기준치가 상대적으로 낮게 설정된 것으로 판단되며, 발레르산, 이소발레르산과 뷰틸알코올의 경우 물질농도 기준치가 적정 수준인 것으로 추정된다. 본 연구결과는 현행 악취방지법의 부지경계선에서 복합악취 농도 규제기준에 대한 개선방안 및 지정악취 물질들의 물질농도와 악취강도, 희석배수간의 상관관계 및 특성연구 등의 기반 자료로 사용될 수 있을 것이다.
4,000원
10.
2018.09 구독 인증기관 무료, 개인회원 유료
In this study, we conducted a survey on odor characteristics of single odor and collective odor facilities using the German olfactory odor method and carried out the odor frequency modeling. The influence of the odor from a sewage treatment plant, which is a single discharge facility, was strong in the eastern and northern parts of the plant and appeared to be in good agreement with the areas where the odor complaints were frequent. The German olfactory method reflects the odor complaints and odor occurrence characteristics of the receptors as compared with the domestic odor measurement method. The influence of the odor from the odor control area, which is a collecting and discharging facility, showed a tendency in which the sum of the odor occurrence frequency increased with the proximity of the odor discharge facility to the dense industrial complex. Furthermore, it was judged that it is not easy to extract the odor frequency results for individual facilities because the survey subject is the group discharge facility area. Therefore, it will be necessary to introduce a method to manage odor in the future. In this study, the measurement of odor frequency using the German olfactory odor method is partially applied to some odor sources. Appropriately, it is not applicable to various emission sources. However, the odor measurement method based on odor occurrence frequency and odor sensory can be used for investigation of the actual condition, permits of odor discharge facilities and the environmental review.
4,300원
11.
2018.09 구독 인증기관 무료, 개인회원 유료
This study is a summary of the complex odor proficiency testing method using the air dilution sensory method conducted for the last 7 years. Results of the homogeneity and stability test were obtained from the measurement of the standard sample for identifying the range of measurable concentration so that the complex odor proficiency testing method was established through processing the manufactured standard sample and distribution method. Standard samples were prepared using a large Teflon bag after being homogeneously mixed inside a Teflon bag. Also, a distributing container was selected with a polyester aluminum bag in order to avoid samples of the best condition from being contaminated during transport as well as being exposed to invasive odor from a sampling bag. Test results revealed that the mixture of toluene and m-Xylene was most appropriate for this proficiency testing method to the homogeneity and stability of the testing method. In addition, DMS and DMDS were the optimized samples at the outlet area. As a result, the standard method was established to address the analysis quality management to the mixed odor inspection agencies in Korea.
4,000원
12.
2018.09 구독 인증기관 무료, 개인회원 유료
봄철 천식환자 가정집 9곳에서 실내 공기를 포집하여 부유진균의 농도 및 다양성을 조사하였다. 조사된 천식환자 가정집의 평균 부유진균 농도는 거실 143 CFU/m³, 방 142 CFU/m³ 이었으며 외기보다 낮았다. 이는 다중이용시설 실내공기질 기준법의 권고기준 기준치 500 CFU/m³를 초과하지 않았음을 보여준다. 총 59균주를 분리하였으며 5속 33종으로 동정하였다. 이 중 병원균으로서 인체에 위해성을 가지고 있는 진균은 4속 12종이었다. 동정된 종 중 Cladosporium crousii, Penicillium maximae, Aspergillus protuberus는 국내에 보고되지 않은 미기록 진균 종으로 확인하였다. 이 중 A. protuberus는 국외에서 인체에 질병을 유발시키는 균으로 알려진 진균이다. 이상의 결과는 천식환자 가정에서 진균의 관리는 정량적 수준에서뿐만 아니라 유해종을 파악하여 관리하는 정성적인 수준에서도 이루어져야 함을 제시한다. 본 연구는 봄철 천식환자 가정집에 존재하는 실내 공기 중 부유진균의 농도 및 다양성에 대한 최초의 연구이다.
4,000원