검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 32

        1.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Timber structures are susceptible to moisture, contamination, and pest infestation, which can compromise their integrity and pose a significant fire hazard. Despite these drawbacks, timber's lightweight properties, eco-friendliness, and alignment with current architectural trends emphasizing sustainability make it an attractive option for construction. Moreover, timber structures offer economic benefits and provide a natural aesthetic that regulates building temperature and humidity. In recent years, timber domes have gained popularity due to their high recyclability, lightness, and improved fire resistance. Researchers are exploring hybrid timber and steel domes to enhance stability and rigidity. However, shallow dome structures still face challenges related to structural instability. This study investigates stability problems associated with timber domes, the behavior of timber and steel hybrid domes, and the impact of timber member positioning on dome stability and critical load levels. The paper analyzes unstable buckling in single-layer lattice domes using an incremental analysis method. The critical buckling load of the domes is examined based on the arrangement of timber members in the inclined and horizontal directions. The analysis shows that nodal snapping is observed in the case of a concentrated load, whereas snap-back is also observed in the case of a uniform load. Furthermore, the use of inclined timber and horizontal steel members in the lattice dome design provides adequate stability.
        4,000원
        2.
        2023.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        경주 및 포항 지진으로 인한 수도관의 파열 및 누수로 배관 시스템용 신축이음부의 내진 안전성 확보가 강조되고 있 다. 일반적으로 금속 벨로우즈에 스테인리스강을 이용한 금속 벨로우즈가 사용되며 목적에 따라 다양한 주름 형상과 단층 및 다층 형태로 제작된다. 그러나 벨로우즈의 불규칙한 산의 형상에 대한 휨 거동 및 피로 파괴에 대한 연구는 미비하다. 본 연구 에서는 벨로우즈의 불규칙한 산의 형상을 고려한 휨 거동을 검토하기 위하여 단조시험, 준정적 반복재하시험 및 피로시험을 수 행하였다. 시험을 위해 제작된 벨로우즈는 단층(1ply)과 다층(3ply)으로 제작되었다. 다층 벨로우즈의 최대하중과 최대변형이 단 층 벨로우즈보다 크게 평가되었다. 단층 벨로우즈는 산과 산 사이에서 파괴가 되었으며, 다층 벨로우즈의 경우에는 산에서 파괴 가 발생하였다. 주름의 높이와 전체 두께가 다른 벨로우즈의 휨 파괴 거동을 평가하였으며, 단층의 초기 피로 균열은 고정 플랜 지와 첫 번째 산의 곡률에서 관찰되었다. 다층의 경우에는 첫 번째 산과 두 번째 산 사이의 곡률에서 관찰되었다.
        4,000원
        3.
        2021.07 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Graphene, a new material with various advantageous properties, has been actively used in various fields in recent years. Applications of graphene oxide are increasing in combination with other materials due to the different properties of graphene oxide, depending on the number of single and multiple layers of graphene. In this study, single-layer graphene oxide and multi-layer graphene oxide are spray coated on polystyrene, and the physicochemical properties of the coated surfaces are characterized using SEM, Raman spectroscopy, AFM, UV-Vis spectrophotometry, and contact angle measurements. In singlelayer graphene oxide, particles of 20 μm are observed, whereas a 2D peak is less often observed, and the difference in surface height increases according to the amount of graphene oxide. Adhesion increases with an increase in graphene oxide up to 0.375 mg, but decreases at 0.75 mg. In multi-layer graphene oxide, particles of 5 μm are observed, as well as a 2D peak. According to the amount of graphene oxide, the height difference of the surface increases and the adhesive strength decreases. Both materials are hydrophilic, but single-layer graphene oxide has a hydrophilicity higher than that of multi-layer graphene oxide. We believe that multi-layer graphene oxide and single-layer graphene oxide can be implemented based on the characteristics that make them suitable for application.
        4,000원
        4.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대공간 단층래티스 돔의 골조프레임 재질로는 알루미늄, 목재, 그리고 강재 등이 사용된다. 소규모 돔에서는 알루미 늄, 목재 등이 사용되는 사례도 많이 있지만, 300m 이상의 대공간 돔에서는 강재를 주로 사용하며, 강재의 단면 형상은 강관 또는 H형강 등이 유리하다. H형강은 기성재가 시중에 판매되고 있어 다양한 종류를 선택할 수 있으며, 지붕 마감 공사 시 시공 성이 우수하다. 본 연구의 목적은 H형강 단면을 사용한 스팬 300m 단층래티스 돔의 좌굴특성을 연구하는 것이다.
        4,000원
        5.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study is to investigate the response reducing effect of a seismic isolation system installed between 300m dome and supports under both horizontal and vertical seismic ground motion. The time history analysis is performed to investigate the dynamic behavior of single layer lattice domes with and without a lead rubber bearing seismic isolation system. In order to ensure the seismic performance of lattice domes against strong earthquakes, it is important to investigate the mechanical characteristics of dynamic response. Horizontal and vertical seismic ground motions cause a large asymmetric vertical response of large span domes. One of the most effective methods to reduce the dynamic response is to install a seismic isolation system for observing seismic ground motion at the base of the dome. This paper discusses the dynamic response characteristics of 300m single layer lattice domes supported on a lead rubber seismic isolation device under horizontal and vertical seismic ground motions.
        4,300원
        6.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        세계적으로 대공간 건축물의 수요가 점점 증가하고 있는 추세에 따라 단층 래티스 돔 구조 시스템은 단순한 외관과 간단한 그리드 패턴으로 인해 300m 공간 구조로 널리 채택 될 것입니다. 선행 연구에서 300m 길이의 단층 래티스 돔에 자중 및 적설 하중을 가했을 때 강재를 이용한 골조 시스템을 이용하여 단층 래티스 돔의 구조 안정성을 대략적으로 파악 하였다. 강성 연결로 되어있는 300m 단층 래티스 스팬의 스팬에 대한 안정성 연구는 이미 많이 수행되었지만 연결부의 강성에 따른 좌굴특성에 대한 연구는 많지 않습니다. 따라서 연구자들이 실제 설계에 적용 할 연구 데이터가 많지 않기 때문에이 구조의 다양한 연결 조건을 연구 할 필요가 있다. 본 연구의 목적은 연결 조건에 따라 300M 단층 래티스 스팬의 좌굴 특성을 분석하여 대공간 단층 래티스 돔의 설계자들에게 도움을 주고자 한다.
        4,000원
        7.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        As the national income grows, there is a growing demand for buildings that require long span structures such as exhibition facilities, sports facilities, special industrial facilities, and aerospace facilities. Single-layer latticed dome is one of representative llong span structures. But single layer latticed domes are apt to occur the unstable phenomena that are called “buckling” because of the lack of strength of members and instability of structures, etc. In the previous study, the structural stability of a single-layer lattice dome was roughly grasped by a frame structural system using a ready-made steel when a self-weight and a snow load were applied to a single-layer latticed dome having a span of 300 m and a height of 75 m. However, a systematic study of a 300m single layer lattice dome with various rise-span ratios was not performed. Therefore, it is necessary to study various conditions of this structure because the researchers do not have much research data to apply to actual design. Therefore, the purpose of this study is to verify the buckling characteristics of span 300M single-layer latticed dome with rise-span ratio
        4,000원
        8.
        2017.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In recent years, single layer latticed domes have attracted many designers and researchers’s attention all over the world, because single layer latticed domes as space structure are of great advantage in not only mechanical rationality but also function, fabrication, construction and economic aspect. Yamada developed the shape factor S which represents the shape of spherical latticed dome from a structural perspective as well as a geometric perspective. According to a prior study, the structural behavior and the buckling characteristics of the latticed dome were mostly noticeable when the shape factor of latticed dome was in the range of 1.5 to 5. That is, S, in the range of 1.5 to 5, are able to estimate not only overall buckling, but also member buckling and nodal buckling. In this study, we developed shape models using various size of members with the fixed rise-span ratio. One particular characteristic of the latticed dome is that it is not only light in weight but also high in strength. But the aiming at the use of light-weight materials and at the minimized section of members may result in buckling to cause an unstable state of the overall structure when the external force reaches a limitation. Especially, the structural strength is disadvantageous to the snow loads than the earthquake loads because of light-weight, and is greatly affected by the conditions of loading. This paper is to develop the structural stability according to the shapes and load conditions for single-layer latticed spherical dome with 300m span.
        4,000원
        9.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In recent years, single layer latticed domes have attracted many designers and researchers's attention all over the world, because single layer latticed domes as space structure are of great advantage in not only mechanical rationality but also function, fabrication, construction and economic aspect. One of the most important factor, in building of single-layer single-layer lattice spherical dome with 300m span, is to ensure the structural safety. Network pattern of single layer latticed domes can be infinitely taken into account. The typical network patterns are triangle, square, hexagon etc. Especially triangular network pattern has mechanically more advantage than the other network patterns because of having not only a large equivalent shearing rigidity but also a large equivalent bending rigidity and axial rigidity. Among the triangular network pattern, that is, 3 way grid pattern, there are many mechanical differences according to the arranging methods of members. In order to ensure the structural stability of single-layer latticed dome with 3 way grid, designers are required to maintain a constant member length and the member angle. In order to achieve this, it is important to search the member array that the standard deviation of the member lengths and angles is the smallest. This paper is to develop the arrangement of member and to verify its validity for single-layer latticed spherical dome with 300m span.
        4,000원
        10.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The single layer latticed domes have attracted many designers and researchers's attention all of the world, because these structures as spatial structure are of great advantage in not only mechanical rationality but also function, fabrication, construction and economic aspect. But single layer latticed domes are apt to occur the unstable phenomena that are called "buckling" because of the lack of strength of members, instability of structural shape, etc. In the case of latticed dome, there are several types of buckling mode such as overall buckling, local buckling, and member buckling according to the shape of dome, section type of member, the size of member, junction's condition of member and so on. There are many methods to increase the buckling strength of the single layer latticed dome, that is, with the change of geometrical shape of dome, the reinforcement of buckled member, etc. Therefore, the purpose of this study is to verify the reinforcement effect of buckled member when designers reinforce the buckled member to increase the buckling strength of single layer latticed dome with 3-way grid.
        4,000원
        11.
        2015.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The roof grid of single-layer space frame structure, for Energy Core of Incheon Airport Second Terminal, is very simple and aesthetic, but it is apt to buckle under external force because of mild curvature and complex shape. The object of this study is to estimate the stability of single-layer space frame structures for Energy Core of Incheon Airport Second Terminal with the analytical conditions of structural design. The results show that the buckling load of model(pin-pin, uniform load, rigid joint), that is, the most similar model to the analytical conditions of structural design. was 10.7kN/㎡.
        4,000원
        12.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Single layer free-form structures are being highlighted in the field of architecture due to its attractive shape. In these structures, node connecting system is very important because the node must resist bending and axial stress simultaneously. So the local and global stabilities of entire structure can be determined by the stiffness of node system. In this study, therefore, various types of bending test with axial force were performed. As a result, bending capacity with axial force of a new spherical node for free-form structure could be performed and structural capacities were checked to use in real structure.
        4,000원
        13.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The circular hollow section is usually used for member of main frame to carry the external load in single layer lattice dome. But, the H-shaped section may be used for member of main frame since it is convenient for attaching roof panels. Single layer lattice domes have various buckling characteristics, such as the overall buckling, the member buckling, and nodal buckling. The purpose of this study is to compare buckling characteristics of single-layer lattice domes in which the H-shaped steel section as the existing domestically-produced structural steel is used as main frames to those of domes in which a circular hollow section is used as main frames.
        4,000원
        14.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : This study is to compare sound transmission loss(STL) value depending on the four kinds of materials, PC(Polycarbonate), PMMA(Polymethyl mathacrylate), PE(Polyethlyene), PP(Polypropylene), and two types of structure, single layer and double with vacuum layer, of soundproof panel. METHODS : With four sorts of polymer material, the specimens were made as various structures, 4 mm and 8 mm of single soundpoof panel and vacuum layered 4 mm of one. The experimental condition and procedures were complied with authorized process test, KS F 2808. RESULTS: STL of single panel made of PC were the greatest followed by PMMA, PE, PP regardless of the thickness of panel, However, STL of PMMA panel began to decrease around 2500 Hz and reached the lowest value among others in 5000 Hz. Vacuum layer soundproof panel showed good performance in more than 2000 Hz. Only vacuum layer panel made of PC presented resonance frequency at 800 Hz while that of other vacuum ones at 1000 Hz. CONCLUSIONS: According to results of single layer, it was found that single panel functioned as the theorical way we expected in terms of surface density. That trends were blurred as the panel got thicker. And it was suggested also that vacuum layer panel performed well at high frequency, more than 2000 Hz.
        4,000원
        15.
        2013.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 일중피복온실의 피복재에 대하여 우리나라 환경에 적합한 관류열전달계수를 산정하는 방법을 찾아내고 검증하여 다양한 온실조건 및 환경조건에서 관류열전달계수를 산정할 수 있는 모델을 제시하는 것이다. 온실내부 및 외부온도와 피복재 표면온도와의 상관관계를 분석한 결과 주간 및 야간 온도를 모두 고려하였을 때보다 야간온도만을 고려하였을 경우가 상관성이 훨씬 더 높은 것으로 나타났다. 피복재의 표면온도가 온실의 외부온도보다는 내부온도와 상관성이 더 높은 것으로 나타났다. 관류열전달계수를 산정하는데 사용된 5가지 종류의 대류 및 복사열전달계수 산정식을 비교한 결과 Kittas가 제안한 대류 및 복사열전달계수 산정식이 가장 적합한 것으로 나타났다. 피복재 표면온도의 측정값과 계산 값의 상관성을 분석한 결과 직선의 기울기는 1.009이고 절편은 0.001이며 결정계수가 0.98로 나타나 본 연구에서 제시된 관류열전달계수 산정모델이 신뢰성이 있음을 확인할 수 있었다. 온실내부로부터 피복재 내부표면으로 전달되는 열흐름량의 경우 모든 풍속구간에 대해 대류열전달량이 복사열전달량보다 더 컸으며 풍속이 증가할수록 그 차이가 증가하였다. 외부표면에서 손실되는 열흐름량의 경우 풍속이 낮을 때에는 대류열전달량에 비해 복사열전달량이 더 컸으나 풍속이 증가함에 따라 그 차이는 점점 줄어들어 풍속이 높을 때에는 대류열전달량이 더 커지는 것으로 나타났다. 피복재 외부 표면의 대류열전달량은 내부표면의 대류열전달량에 직선적으로 비례하여 증가하는 것으로 나타났다. 풍속이 증가함에 따라 관류열전달계수는 증가하고 피복재의 표면 온도는 감소하는 것을 확인할 수 있었고, 변화추세를 보면 관류열전달계수는 거듭제곱함수와 그리고 표면온도는 로그함수와 잘 일치하였다.
        4,000원
        16.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The large-space single-layer lattice dome is relatively simpler in terms of the arrangement of the various framework members and of the design of the junction than the multi-layered lattice dome, can reduce the numbers and quantity of the framework members, and has the merit of exposing the beauty of the framework as it stands. The single-layer lattice dome, however, requires a stability investigation of the whole structure itself, along with an analysis of the stress of the framework members, because an unstable phenomenon called "buckling" occurs when its weight reaches critical levels. Many researchers have systematically conducted researches on the stability evaluation of the single-layer lattice dome. No construction case of a single-layer lattice dome with a 300-m-long span, however, has yet been reported anywhere in the world. The large-space dome structure is difficult to erect due to the gigantic span and higher ceiling compared with other common buildings, and its construction cost is generally huge. The method of erecting a structure causes major differences in the construction cost and period. Therefore, many researchers have been conducting various researches on the method of erecting such structure. The step-up method developed by these authors can reduce the construction cost and period to a great extent compared with the other general methods, but the application of this method inevitably requires the development of system supports in the center section as well as pre-existing supports in the boundary sections. In this research, the safety during the construction of a single-layer lattice dome with 300-m-long span using pre-existing materials was examined in the aspect of structural strength, and the basic data required for manufacturing the supports in the application of the step-up method developed by these authors during the erection of the roof structure were obtained.
        4,000원
        17.
        2012.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Successful application of graphene requires development of various tools for its chemical modification. In this paper, we present a Raman spectroscopic investigation of the effects of UV light on single layer graphene with and without the presence of O2 molecules. The UV emission from a low pressure Hg lamp photolyzes O2 molecules into O atoms, which are known to form epoxy on the basal plane of graphene. The resulting surface epoxy groups were identified by the disorder-related Raman D band. It was also found that adhesive residues present in the graphene samples prepared by micro-mechanical exfoliation using adhesive tape severely interfere with the O atom reaction with graphene. The UV-induced reaction was also successfully applied to chemical vapor deposition-grown graphene. Since the current method can be readily carried out in ambient air only with UV light, it will be useful in modifying the surfaces of graphene and related materials.
        4,000원
        18.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        단층 래티스 돔과 같은 스페이스 프레임 구조물은 대공간을 확보하기 위하여 강접합으로 설계함으로써 경제성과 심미성 등의 장점을 확보할 수 있다. 그러나 실제 구조물의 접합상태는 완전한 강접합도, 완전한 핀접합도 아닌 접합부 상세에 따라 중간적인 특성을 나타내는 반강접합이 일반적이다. 본 연구에서는 저자 등에 의해 제안된 Step-Up Erection 공법을 적용하여 단층 라멜라 돔의 접합부 강성에 따른 시공 중의 좌굴 특성을 해석적으로 규명하였다. 얻어진 결과는 시공 Step이 증가할수록 그리고 접합부 휨강성이 핀접합에 가까울수록 좌굴내력은 감소하였으며, 좌굴모드는 시공 Step이 증가할수록, 접합부 휨강성이 강접합에 가까울수록 돔의 정점 부근에서 뜀좌굴 현상에 의한 절점좌굴이 발생하였다. 또한, 시공 Step이 낮을 경우 저면 경계부의 원주방향 부재에서 큰 인장응력 분포를 나타내었으며, 시공 Step이 증가할수록 정점 중앙부에서 큰 압축응력 분포를 보였다. 완성돔을 제외한 시공 중 Step에서는 Step이 증가할수록, 접합부 휨강성이 핀접합에 가까울수록 저면부 경선방향 부재에서 큰 인장응력 분포를 나타내었다.
        4,000원
        19.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        대공간 구조형식을 갖는 단층 래티스 돔은 역학성, 가능성, 심미성 등을 갖는 구조물로서 그 용도가 점점 확대되고 있다. 단층 래티스 돔의 골조 격자 패턴은 무수히 존재하며, 그 대표적인 패턴에는 삼각형, 사각형, 육각형, 라멜라형, 리브형 등이 있다. 대공간 구조물의 경우, 일반구조물과 달리 재래적인 공법으로 지붕 골조를 시공할 경우 많은 가설재가 소요됨으로 시공비 증가가 예상된다. 따라서 대공간 구조물의 지붕 골조 설치는 특수 Erection 공법에 의하는 것이 일반적이며, 그 중 지상에서 지붕골조를 설치 후 jack-up 서포트에 의해 골조를 인양하는 Step-Up 공법을 적용할 경우 공기와 공비의 대폭적인 절감이 예상된다. 따라서 본 논문의 목적은 Step-Up 공법에 의해 단층라멜라 돔의 지붕골조를 시공할 경우, 인양 중 가설 서포트 개수와 위치에 따른 좌굴특성을 검토하는 것이다. 연구 결과 서포트 개수 및 위치에 따른 단층라멜라 돔의 다양한 좌굴 특성에 관한 실무자를 위한 기초적인 자료를 얻을 수 있었다.
        4,000원
        20.
        2008.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        단층 래티스 돔은 경량이면서도 높은 강성을 가지므로 대공간 구조물로서 유리하며, 이 구조물은 기둥 없이 널은 공간을 확보해야하는 구조적 특성으로 인하여 시공시 불안정 현상이 발생할 수 있다. 현재 국내에서 대공간 지붕구조물의 설치 방법으로 가장 많이 도입되고 있는 Erection공법은 Block공법이며, 이 공법은 지상에서 조립한 대공간 지붕 골조를 크레인 등으로 소정의 위치까지 들어 올려 지붕구조를 완성해 가는 설치 공법이다. Block 공법에 있어서 인양할 포인트를 선정하는 작업은 대단히 중요하다. 즉, 인양 시 골조의 변형과 좌굴 등에 대해서 가장 안전하고 경제적인 절점을 인양 포인트로 선정할 필요가 있다. 따라서 본 연구에서는 가장 안전하고 경제적인 Erection을 위한 기초자료를 얻기 위하여 삼각형 네트워크를 갖는 단층 래티스 돔의 Erection 시 인양 포인트에 따른 구조물의 거동 및 좌굴 특성을 연구하는데 그 목적이 있다. 얻어진 결론은 1) 돔의 높이 H가 작을수록 인양위치에 따른 좌굴내력의 영향이 큰 것을 알 수 있었으며, 반대로 돔의 높이 H가 클수록 인양위치에 따른 좌굴내력의 영향은 미미한 것을 알 수 있었다. 2) 인양 위치에 관계없이 인양로프 길이에 따른 좌굴내력의 영향은 크지 않은 것을 알 수 있었다.
        4,000원
        1 2