하천시설물은 정보의 관리주체가 국가하천과 지방하천 등에 따라 달라서 통합되어 관리되지 못하고 있는 점, 설계 및 시공 단계의 정보화 축적이 미흡하여 시설물 정보의 망실이 우려되는 점 등 하천분야로 BIM 도입을 하기 위해서는 해결해야 할 과제들이 산재해 있다. 또한, 이로 인해 유지운영단계에서의 시설물 정보 활용 수준 역시 상당히 미흡한 편이다. 따라서, 하천시설물의 효과적인 유지 운영을 위해서는 표준분류체계에 따라 시설물 정보를 정리함으로 데이터의 일관성을 확보하고 효율성을 증대시킬 필요가 있다. 본 연구에서는 이러한 하천분야의 시설물 특성을 고려하여 하천분야의 BIM 정보모델 도입과 3차원 기반의 하천시설의 효율적인 유지 운영 전환을 위한 BIM 표준분류체계를 적용하는 방안을 제시한다.
This study sought to conduct a fundamental investigation in order to test and evaluate the thermal performance of an aluminum stick curtain wall system. In terms of the thermal performance index, the infiltration rate of air tightness, thermal transmittance of the heat insulation property and temperature difference ratio of condensation resistance were experimentally measured. The research process can be divided into three parts. First of all, a database for the test report of the curtain wall was compiled and existing design criteria with respect to the evaluation method and standard of transparent building components such as curtain wall, window and door were analyzed to produce the specimens. Secondly, four different types of curtain wall specimens were created through investigating the curtain wall database. Thirdly, standard tests of thermal performance were carried out for airtightness, thermal performance and condensation resistance. As a result, the curtain wall specimens with low-e triple glazing covered by an aluminum capture system showed high thermal performance compared to other curtain wall specimens including low-e triple glazing with a 4-sided structural sealant glazing system. Air tightness of all types of curtain wall specimens satisfied level 1 standard for air tightness. It was found that a curtain wall which consists of a one track frame has difficulties meeting the residential standard of thermal performance with regard to thermal transmittance and condensation resistance.
This study aims to design a new sizing system for hygienic masks to protect against COVID-19-related respiratory disorders. The product sizes were collected from 70 commercially available hygienic masks, and 18 head measurements were obtained from the three-dimensional (3D) scan data of 2,048 men and women aged 20 to 69 years from the 6th Size Korea Survey. The statistical analysis was performed using the IBM Statistical Package for the Social Sciences (SPSS) 28.0 program. The “bitragion-subnasale arc” and “menton-sellion length” were chosen as the key body dimensions for the hygienic mask sizing system. The linear regressions with 18 3D head measurements were analyzed, and it was determined that the key body dimensions were useful for statistically predicting other 3D head measurements related to hygienic masks. A new sizing system was proposed for two types of masks, “masks with a tight fit” and “masks with a loose fit,” taking into account the existing Korean Industrial Standards (KS) and the shortcomings of the sizes of hygienic masks on the market. The sizing system for tight-fitting masks consisted of the key body dimensions, with their sizes indicated by a pair of numbers. The sizing system for loose-fitting masks consisted solely of the bitragion-subnasale arc, with their sizes denoted by letters such as S, M, and L (denoting small, medium, and large, respectively). Future studies should consider this mask sizing system for different age groups, such as children and adolescents.
대한민국 기상청에서 사용하고 있는 UM (Unified Model, UM) 모델의 국지예측시스템(Local Data Assimilation and Prediction System, LDAPS)은 수치모델 모의 시 대기경계층 유형에 따라 물리과정을 다르게 계산하기 때문에 이 과정을 검증하는 것은 모델의 정확도 향상에 중요하다. 따라서, 본 연구에서는 수치모델의 대기경계층 유형을 관측자료 를 기반으로 검증하였다. 관측자료를 기반으로 대기경계층 유형을 분류하기 위해서 보성 표준기상관측소에서 수행한 여름철 집중관측자료(라디오존데, 플럭스관측장비, 도플러 라이다, 운고계)를 활용하였으며, 2019년 6월 18일 부터 8월 17일 까지 61일 동안에 총 201회의 관측자료를 분석하였다. 또한 관측자료와 수치모델 결과가 다른 경우를 보면, 관측자료를 기반으로 한 대기경계층 유형 분류 결과에서 2유형으로 분류되는 사례가 수치모델에서는 1유형으로 분류된 사례가 53회로 가장 많이 나타났다. 그 다음으로는 관측자료를 기반으로 한 대기경계층 유형 분류 결과에서 5유형과 6유형 으로 분류되는 사례가 수치모델에서는 3유형으로 분류된 사례가 많이 나타났다(각각 24회, 15회). 관측결과와 수치모델 모의 결과가 일치하지 않은 사례는 모두 층적운 접합 여부 및 적운 모의 등 수치모델의 구름물리 부분의 모의 성능에 기인하여 발생한 것이라고 분석된다. 따라서, 대기경계층 유형 분류의 구름물리과정의 모의 정확도를 개선하면 수치모델 성능이 향상 될 것으로 판단된다.
A finite element impact simulation study was performed to assess structural performances of a guard-rail system for roadside using new steel materials (SS275) in the KS standard. The type SS275 shows an enhanced tensile strength in comparison with the former type SS400. Subsequent simulation results present that the improved model performs much better in containing and redirecting the impacting vehicle in a stable manner. The numerical results for various parameters are verified by comparing different models with dynamic responses determined in the barrier from the crash simulation.
Aquatic ecosystems are receiving various harmful effects due to anthropogenic chemical pollutions. To protect wildlife, risk assessments of the chemicals are conducted using reference indexes of toxicity estimated by species-level laboratory tests and/or micro-/mesocosm community-level studies. However, the existing micro-/mesocosm communities are structurally too complicated, and it is also difficult to compare the experimental results directly with those from species-level tests. Here, we developed a procedure of a simple bi-trophic microcosm experiment which contains the common species (a green algae, Pseudokirchneriella subcapitata and a cladoceran, Daphnia magna) for testing chemical toxicities. For the proper operation of bitrophic microcosm experiment, the minimum required concentration of primary producer (P. subcapitata) is 5×105 cells mL-1. The microcosm system showed higher stability when the initially introduced D. magna population was composed of neonates (<24-h old) than adults and those mixture. This simple microcosm system would be an applicable tool to estimate the disturbing impacts of pollutants on plant-herbivore interactions, and linking the species- and population-/community level risk assessments in the future studies.
공연장의 무대기계설비 시스템 및 조명장비 시스템 설치 완료 후 각 시스템의 최종 검사에 적용되는 검사 기준과 검사 방법을 명시함으로써 효율적으로 최종 설비 상태 를 점검하고, 발주처의 최종 검사에 효과적으로 대비할 수 있게 하고 안전사고를 미리 예방할 수 있게 하기 위하여 연구하였다.
It is not easy to establish the correct standard time and standard manhour in a process of small quantity batch production system, especially in a case of irregular quantity of production. Therefore, how to establish rational standard time about manufactu
In medium and small firm, the management system which is simple and where there is a practicality is required Ill)re than the management system which is complicated and minute of the centered around large company so that the introduction of the standard costs can be activated and it can be usefully used as a tool of management decisions. A difference between the standard costs introduction plan proposed in this paper and the preexistance study literature are as follows. In this paper, by breaking from the whole cost accounting aiming at all item, that is the traditional introduction method, and presenting the product cost accounting method by group the standards setting object was minimized and simplified. In this way, if the standards setting object is simplified, it is quick at the perimeter environment change as the little man power and flexibly it corresponds to and the cost information calculation which is exact with the setting up and maintenance of the efficient cost standard becomes available. As a result of applying for real through S corp., the usability of the method that the standard costs introduction method proposed in this paper produced the standard costs relatively short within period, it manages was verified. And the standard costs introduction method proposed in this paper went by the various cost information for each products, the management class did the management will decision which was objective and reasonable in the putting first.
융설액 분사 시스템은 강설이 예상되거나 진행 중인 상황에서 즉시 대응이 가능하며, 강설 초기에 효율적인 처리로 강설로 인해 발생 가능한 교통사고와 교통 지정체를 감소시킬 수 있는 장점을 가지고 있다. 그러나 시스템의 설치비용이 고가이고, 설치되는 장비의 종류에 따라 운영 및 유지관리 비용이 지속적으로 소요되기 때문에 모든 도로 구간에 설치하는 것은 현실적으로 불가능하다. 최근 국내에서는 결빙 위험 구간을 파악할 수 있는 프로그램들이 개발되어 턴키 및 대안 설계에 활용되고 있다. 그러나 프로그램 개발 업체들마다 분석 방식이 상이하고 객관적인 기준이 없는 실정이다. 이에 따라 융설시스템 적용구간에 대한 기준 마련도 시급하다고 볼 수 있다. 본 연구에서는 선형, 기상조건, 일조조건 등을 다양한 도로 조건을 정량화하여 어떤 구간에 우선적으로 융설시스템을 적용하여야 하는지 판단할 수 있는 기준을 제시한다. 이를 위해 국내 지역별 기상 조사, 지형지물에 의해 음지 발생 여부 분석, 선형과 미끄럼 저항성을 고려한 차량 시뮬레이션 등을 수행하고 이론적 검토를 통해 설치 기준 방법론을 정립하는데 중점을 둔다.
To help the corporations ensure more efficient production management, the Enterprise Resource Planning (ERP) system has been introduced in operation, together with a variety of approaches to make improvements in terms of quality and productivity issues. Yet, with the different types of ERP systems in operation, many companies are going through many difficulties not only in having greatly reduced work efficiency but also in making prompt decisions from the entire group-based integrated information. In this study, the analysis was made on their own ERP systems and working processes operated by a company running the multiple number of productions from the domestic and the overseas suppliers, in order to support their interacted work flow regarding their products and help improve the work efficiency by establishing standardized ERP system. Through this, it is expected to ensure more competitive system in operation by securing the flexibility in the production as well as efficient resource distribution under the corporate context of cost reduction and quality improvement.
Recently, the various information according to the company management is originated in the change of the rapid company environment. And the necessity of the administration,that is systematic and efficient toward the various document of a form, is gradually increased. At the same time, the efficient management ability of the various standard document obtained the specialized quality authentication system including the ISO/TS16949, ISO14001, quality 5 star, and etc., it maintains occupies the very important part as to the company management. This research suggests the standard business process of the auto part supplier for the efficient management of the standard document. In addition, by building and managing the standard management system will be able to expect the more efficient document management and the product reliability insurance.
The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.
The present management of the domestic and international advanced enterprises is transferring the systems and the regulations to the prevention system management. Expecially, KOSHA (Korea Occupational Safety & Health Agency) in Korea has supported to set up the OSHMS (Occupational Safety & Health Management System) by KOSHA 18001 since 1997. But small & medium enterprises (SMS) have many difficulties to set up the OSHMS because of limited natural and human resources. Therefore, this study is developed and proposed the certification standard of an OSHMS for SMS based on the case study on advanced countries, actual conditions of SMS in Korea, and opinion of specialists.
초 록
현재 우리나라는 1997년 7월부터 KOSHA18001 인증제도를 운영하여 사업장의 안전보건경영시스템 구축을 지원하고 있다. 그러나 사업장 규모에 따라 그 수준이 현저하게 차이가 있을 뿐만 아니라 안전보건경영시스템의 평가기준이 복잡하고, 어렵기 때문에 담당자들이 시스템 인식에 어려움을 겪고 있다. 특히, 중소규모 사업장은 한정된 자원과 인력으로 자율안전보건경영체제를 구축하기에는 더욱 어려움이 크다. 따라서 본 연구에서는 국내 중소규모 사업장의 자율안전보건경영체제 구축을 지원하기 위해 선진국의 안전보건경영 관련 사례와 국내 사업장의 의견을 바탕으로, 중소규모 사업장용 안전보건경영시스템 인증기준(안)을 개발하였다.
In this paper, we propose a systematic procedure to determine standard time and cycle time in a TFT-LCD factory. The proposed procedure mainly consists of data preprocessing, hypothesis testing and Group technology. Data preprocessing extracts relevant da