        42.
        2017.10 구독 인증기관·개인회원 무료
        We investigated pollination properties of bumblebees in a high temperature condition i. e. a greenhouse where onions(Aliumcepa) were cultivated. Foraging activity of bumblebee workers decreased at temperature over 33 ℃ and was negativelycorrelated with colony temperature. Fanning behavior was observed at temperature over 30 ℃ and was positively correlatedwith colony temperature. There was negative correlation between the number of bees fanning and bees foraging. We expectedthat foraging activity would be affected by colony temperature and fanning behavior. The temperature of the coloniesthat were ventilated using the cooler fan was 3 ℃ lower than the control colonies, and the rate of fanning behaviorwere 9 times lower in ventilated colonies than in the control colonies. Foraging activity and survival rates of workerbees in ventilated colonies doubled compared to the control colonies
        43.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        While the air quality of public facilities such as daycare centers is managed by law, the management of air quality in residential buildings is not mandatory. For this reason, air quality in an apartments has not been well surveyed. In this study, we investigated the influence of cooking and ventilation on the indoor air quality in an apartment. Continuous measurements were performed using real-time monitoring instruments from June 9 to 17, 2014 in Seoul, Korea. A CO2 meter was used to measure CO2 concentration and temperature. A portable aerosol spectrometer (0.25-32 μm), a nanoparticle aerosol monitor (10-1,000 nm), and an aethalometer (total suspended particulate, black carbon) were also used. During the measurement period, ventilation and cooking activities were observed 8 and 10 times, respectively. In 5 of the observed cases, both activities were done simultaneously. During the ventilation, CO2 concentration and temperature were decreased; however, particle concentrations were increased. When cooking was done, particle concentration was increased in some cases; however, CO2 concentration and temperature were unchanged. Combined cased CO2 concentration and temperature were decreased and particle concentrations were increased.
        4,300원
        44.
        2017.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        간척지 온실의 환경설계 기술 개발을 위한 기초자료 제공을 목적으로, 첨단 시설원예단지 설치 계획이 있는 국내 7개 대규모 간척지 주변의 기후조건을 분석하였으며, 새만금 간척지 내에 설치된 3연동 플라스틱 온실을 대상으로 하절기에 시설 내외의 열적 환경계측 실험을 통하여 자연환기 및 온도 상승 특성을 분석하고, 간척지 온실의 환경 설계에 적용해야 할 부분을 검토하였다. 작물의 유무에 따른 온실의 환기율을 비교한 결과, 작물이 있으면 온실의 환기율은 낮아지지만 작물의 증발산에 의해 실내기온 상승은 감소하는 것으로 나타났다. 작물이 있는 경우 온실의 환기회수는 대체로 0.3~0.9회/min의 범위에 있었고, 평균 0.7 회/min으로 나타났다. 실외기온 대비 실내기온 상승은 1~5oC정도의 범위에 있었고, 평균 2.5oC로 나타났다. 간척지에 설치된 실험온실의 자연환기 성능은 여름철 권장 환기율을 거의 만족시키고, 실외기온 대비 실내기온 상승도 작물재배 환경을 크게 벗어나지 않으므로 새만금 간척지에서는 냉방설비 없이 자연환기 만으로 온실의 작물 재배가 가능할 것으로 판단된다. 간척지는 해안에 위치하고 있어 내륙지역에 비하여 바람이 강하고, 안개가 자주 끼는 특성을 보이는 것으로 나타났다. 이와 같이 강한 풍속은 온실의 환기율을 증가시키므로 냉방부하의 감소요인으로 작용하게 될 것으로 판단된다. 또한 안개지속시간이 내륙지역에 비하여 현저하게 길기 때문에 기간냉방부하는 감소할 것으로 예상되며 이는 냉방 설비의 운전경비 측면에서 유리할 것으로 판단된다. 또한 간척지 온실의 환기 및 냉방시스템 설계 시에는 주변의 기상관측소 자료를 그대로 이용하지 말고, 온실 설치 지역에서 실측한 기상자료 또는 현장 여건을 반영하여 보정된 기상자료를 사용하여 설계하도록 할 필요가 있다.
        4,000원
        45.
        2017.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Suncheon Songgwangsa has unique ventilation roofs. In the meantime, these roofs have been known as a characteristic element of Songgwangsa architecture and a unique element of Korean traditional architecture. I would like to review the installation time of the ventilation roof and check the installation time through Songgwangsa’s records and photographs. According to the results of this study, it was confirmed that the ventilation roofs installed in various buildings including the temple of Songgwangsa were installed between the 1920s and 1930s. This can be summarized by comparing the history of Songgwangsa and the history of each building of Songgwangsa by comparing the paintings of Songgwangsa in 1886 and 1915 with the photographs of 1920s and Songgwangsa in the 1930s. It is a matter of further study whether the installation of the ventilation roof of Songgwangsa Temple is influenced by the Japanese occupation period.
        4,200원
        47.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigated the odor-associated bacterial community in automobile HVAC systems. Through a metagenome analysis, it was found that; Massilia (42.426%), Sphingomonas (28.200%), (10.780%), and Methylobacterium (5.756%) were abundant in the HVAC systems. Massilia can cause the biodegradation of polycyclic aromatic hydrocarbons (PAHs) producing odor in automobiles. Sphingomonas produces volatile halogenated compounds or degrades organic pollutants. Rhodococcus is reported to produce sulfur compounds which give off an odor similar to rotting eggs and cabbages. Methylobacterium is one of the most representative bacteria that causes odor in automobile HVAC systems. The evaporator is considered as the appropriate habitat for microorganisms in automobiles because of its high humidity and organic adsorption. Massilia, Sphingomonas, Rhodococcus, Methylobacterium, Bacillus, Staphylococcus, Arthrobacter, Micrococcus, and Pseudomonas, listed in order from most to least present, were isolated as abundant bacteria in the evaporator of the HVAC systems.
        4,000원
        48.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        지붕 환기장치 설치방법의 개선에 의한 작물 재배효과를 검증하고자 농가현장에서 개선 지붕 환기방식과 관행 환기방식을 비교, 분석하였다. 개선 지붕 환기방식은 참외재배 단동 플라스틱 온실(폭 5.6m, 길이 108m, 측고 1.1m, 동고 2.2m)에 지붕 환기팬(용량 38m3/min)과 환기 통(지름 60cm)을 각각 15m와 6m 간격으로 설치하였고, 대조구로서 관행 지붕 환기방식은 각각 20m와 8m 간격으로 설치하였다. 관행 및 개선 지붕 환기 방식에 따른 생육을 조사한 결과, 관행 환기통과 환기팬 처리에 비해 개선 환기통과 개선 환기팬 처리에서 경경, 엽장, 엽병장, 및 엽폭의 값이 낮게 나타나는 경향을 보였다. 생육기 전반부에 관행 환기통 처리는 환기팬 처리에 비해 절간장이 다소 길게 발달하였는데 이는 착과수가 환기팬 처리에 비해 적었고, 착과수 감소로 인해 동화산물이 잎과 줄기의 신장부로 좀 더 이동된 영향으로 판단되었다. 참외재배 단동 비닐하우스에서 과실 수량을 조사한 결과, 개선 환기팬과 개선 환기통 처리는 관행처리에 비해 과중은 약간 작았지만, 착과수 증가로 인해 전체 수량은 높게 나타났다. 개선 환기팬과 개선 환기통 설치 하우스에서는 관행 지붕 환기 하우스에 비해 상품과율이 높았 으며, 10a당 상품수량도 각각 8,391kg, 7,283kg 으로 나타나 관행 지붕 환기에 비해 개선 환기팬 처리는 661kg, 개선 환기통 처리는 487kg 더 증가하였다. 개선 환기팬 처리는 고온기에 암꽃수와 착과수가 가장 많았고, 낙과수는 가장 낮게 나타났으며, 관행의 환기통 처리에 비해 과실의 크기는 작았다. 시기별 환기방식에 따른 참외 과실의 품질을 조사한 결과, 관행 환기통 환기에서 과중, 과경, 과폭, 및 과육두께가 가장 높게 나타났으나, 과폭, 과육두께에 있어서 통계적인 유의차는 나타나지 않았다.
        4,000원
        50.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, We evaluated the efficiency of the smart ventilation system being developed at the test-bed(KCL). Smart ventilation system improve the indoor air quality by absorbing carbon dioxide. It is reducing the infusion of outside air can be reduced to minimum energy consumption. To evaluate the energy savings and carbon dioxide removal efficiency. It was more effective when working with air conditioning and ventilation system at the same time.
        4,000원
        51.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Air-shiter is a new products possible ventilation at the same time cooling or heating with integrated refrigeration and ventilation units. and is a key component of the air shifter devices and bypass damper. The air shifter devices are to convert the outdoor air, room air, supply air and exhaust air flow. And the bypass damper is device to determine a ventilation. After research and development of these systems were as follows. It is confirmed that the Air-shiter is possible ventilation at the same time cooling or heating, and outdoor air cooling in the spring or fall.
        4,000원
        52.
        2015.03 구독 인증기관 무료, 개인회원 유료
        In this study, a scaled model chamber was built to investigate ventilation characteristics of the pump room in tanker and to look into stationary areas of flow field. Experimental study was performed for three kinds of Reynolds number based on the inward velocity and height of inlet port in model by visualization equipment with laser apparatus. The flow pattern reveals the large scale counterclockwise forced-vortex rotation from upside louver to lower scupper toward diagonal corner and also found small eddies at bottom layer.
        3,000원
        53.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the ventilation of duct is simulated by CFD and thermal changes on the seat surface are measured experimentally. These models are the improved duct and the existing one installed at the real seat in order to test the thermal change 1 minute later. The seat with the existing duct has the temperatures of 26℃ and 25℃ on lumber and femoral parts respectively. However, the seat with the improved duct has the temperature of 1℃ lower than the seat with the existing duct. This result contributes to develop the improved duct. Hereafter, the methods used in this study are expected to be useful at checking the flow resistance loss of the ventilation seat duct and assessing the flow channel design
        4,000원
        54.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        We have performed CFD simulation and analyzed flow and concentration fields for the basic data of the ventilation system for removing pollutants which were produced in a lecture room. The flow patterns indicated differently according to the arrangement of openings and the concentration distribution of pollutants were showed higher and lower because of the effect of that flow patterns. In the case of arranging the openings to the upper and lower side, the stagnation appearance of flow formed in the interested space. In the case of arranging the openings to the right and left side, the stagnation of high concentration pollutants appeared in the middle area of the interested space. On the increasing exhaust velocity, the distribution of pollutants appeared similar to the normal case, but the concentration of pollutants were lower.
        4,000원
        55.
        2014.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to investigate information on performance of ventilation in high-tech microelectronicscleanrooms using computational fluid dynamics (CFD). One liquid crystal display (LCD) company was examinedfor evaluating the relationship between workplace concentration and ventilation rate efficiency by using CFDsoftware, Airpak 3.0v. Acetone concentration in cleanroom for final packing process, which is inspected LCD was40.1ppm (GSD 1.91) (n=55) as geometric mean, ranged 7.8~128.7ppm and weakly correlated with ventilationrate efficiency (R²=0.37, p<0.01). Resulting from computational fluid dynamics (CFD), acetone concentrationcan be reduced 62% when install booth type local exhaust system, the most efficient way among 10 other differentventilation methods like increasing volume of general ventilation, changing the location of workers, supply orexhaust diffusers and install downstream type local exhaust system, etc. We found that volitile organic compoundsin cleanroom can be a matter of adverse health effects and the concentration was correlated with ventilation rateefficiency. The most optimized plan to control the contaminants in solvent cleaning work in cleanroom was boothtype local exhaust system.
        4,000원
        56.
        2013.10 구독 인증기관 무료, 개인회원 유료
        In the design of urban rail traffic entrances and ventilation pavilion in the city of Zhengzhou, Henan province, this study tries to explore a kind of regional appearance about the subway entrances and ventilation pavilion design in the new period through the combination of sustainable building ideology [ 1] and local culture. The creation inspiration of the design is from the aspects of humanism, and the design tries to make the building have distinct regional characteristic in the premise of the contemporary feeling with the rational method. The building is located in the central plains , where the cultural resources are very rich. The design tries to choose clements that are from the famous cultural heritage and appeared appropriately in the plan, which to read and promote culture with the perspective of modem style architecture, and also make the subway entrance building have local differences and the identify ability. In the deepening of the design, the green and sustainable thought is the main exploration direction. The design tries to use High-tech building materials, and shows the building texture with the Combination of ETFE (ethylene-tetra-fluoric-ethylene) and steel skeleton, which appear the structure and the form of the building in the new period with the eco-friendly style. At the same time, the design discusses the way of Subway Entrances and the ventilation pavilion in central plains under the constraints of geography, climate and function.
        4,000원
        57.
        2013.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        측고, 연동수, 측창의 유무 및 천창의 위치에 따른 다연동 온실의 환기성능을 평가하기 위하여 다양한 유형의 연동 플라스틱 온실을 대상으로 실제 농가의 재배현장에서 환경계측 실험을 수행하였다. 실험 대상 온실은 모두 토마토를 수경재배하고 있는 농가였으며, 열수지 방법으로 환기율을 비교 분석하였다. 측고가 4m인 온실은 측고가 2m인 온실에 비하여 22% 정도의 환기율이 증가하는 것으로 나타났다. 9연동 온실은 5연동 온실에 비하여 17% 정도의 환기율이 감소하는 것으로 나타났다. 9연동 온실에서 측창이 없는 경우에는 측창을 설치한 경우 보다 환기율이 1/3 정도로 낮게 나타났다. 전체적으로 다연동 온실의 환기성능은 측고가 높을수록 좋고, 연동수가 많을수록 떨어지며, 측창이 없으면 현저하게 저하하는 것으로 나타났다. 또한, 측고가 높고 천창을 용마루에 설치한 경우의 환기성능이 가장 우수한 것으로 나타났다. 따라서 다연동 온실의 자연환기 성능을 극대화하기 위해서는 온실의 측고는 높이고, 지붕 환기창의 위치는 곡부가 아니라 용마루에 설치하며, 측창을 반드시 설치하고, 연동수는 10연동 내외로 제한하는 등의 구조개선이 필요하다.
        4,000원
        58.
        2012.08 구독 인증기관 무료, 개인회원 유료
        In the design of urban rail traffic entrances and ventilation pavilion in the city of Zhengzhou, Henan province, this study tries to explore a kind of regional appearance about the subway entrances and ventilation pavilion design in the new period through the combination of sustainable building ideology 【1】and local culture. The creation inspiration of the design is from the aspects of humanism, and the design tries to make the building have distinct regional characteristic in the premise of the contemporary feeling with the rational method. The building is located in the central plains,where the cultural resources are very rich. The design tries to choose elements that are from the famous cultural heritage and appeared appropriately in the plan, which to read and promote culture with the perspective of modern style architecture, and also make the subway entrance building have local differences and the identify ability. In the deepening of the design, the green and sustainable thought is the main exploration direction. The design tries to use High-tech building materials, and shows the building texture with the Combination of ETFE (ethylene-tetra-fluoric-ethylene) and steel skeleton, which appear the structure and the form of the building in the new period with the eco-friendly style. At the same time, the design discusses the way of Subway Entrances and the ventilation pavilion in central plains under the constraints of geography, climate and function.
        4,000원
        59.
        2011.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 표준 개방한우사 설계도에서 제시된 처마의 길이보다 짧게 개방한우사의 처마가 시설되었을 때 지붕의 기울기와 동일하게 처마를 연장하는 것과 기둥 위치에서 수직으로 비가림시설을 하는 경우, 어느 우사가 우의 더위 스트레스 경감, 우방 바닥 건조, 비 들이침 및 환기효율에 더 유리한지를 규명하기 위하여 표준길이의 처마와 3종의 비가림 시설을 대상으로 computational fluid dynamics (CFD) 시뮬레이션기법을 이용하여 수행하였다. 여름철의 평균 풍속인 1.2 m/s에 근거하여 시뮬레이션을 한 결과, 여러 형태로 수직 비가림시설을 설치하는 것보다 표준 처마길이로 시공하는 것이 환기 및 풍속분포가 양호하였다. 따라서 수직으로 비가림시설을 하는 것보다는 축사 표준설계도에 제시된 처마 길이 정도까지 지붕의 기울기와 같게 처마를 연장하는 것이 유리하다.
        4,000원
        60.
        2011.06 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        Recently, the air pollution have bad effects on the indoor environment. Many buildings around the world use natural ventilation. to remove the air pallutant. But, nowadays, ventilation requirements can be demanding, as modern systems require greatly improved reliability and control. The fan and the duct are used to remove air mechanically from the space. Until now, apartment houses have been relying on the duct supply system ventilation rather than other system ventilations. Therefore, the establishment of a prediction method based on optimal ventilation energy consumption using duct supply system and ductless is the ultimate goal of this study. As a result, this study found that the characteristics of duct and ductless supply system ventilation are dependent to each exhaust system. Consequently, the local supply indices of the duct supply system is definitely superior about 24.6% ~ 26.4 % than those of ductless supply system. However, the duct supply system has greater pressure drop in ventilation area than ductless, and duct system needs a lot of ventilation energy. In this study, The ductless supply system has advantage over the duct system about 14.8 % as duct exhaust system and 20.0% as ductless exhaust system in terms of modified local supply indices.
        4,300원