검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 15

        1.
        2024.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study improved the work efficiency by supplementing the shortcomings of the manual process by developing a double tube feeding device, and the following results were obtained by conducting the production capacity, production length, and defect rate tests. Developed a double tube production system to enable the simultaneous production of two tubes, increasing the production volume by about 1.5 times. The product length has been improved from semi-automatic to automated, and the production capacity has been improved from 16 to 25 pieces per hour (based on 15m). Developed a double-tube input straight line automatic adjustment feeder, which resulted in reducing the defect rate to less than 1%.
        4,000원
        2.
        2023.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Recently a biosafety level-3(BL-3) mobile laboratory has been set up for the virus scanning and vaccine development because of the COVID-19 pandemic. The study on air flow inlet and outlet location and its flow direction with ventilation in the mobile laboratory needs to prevent spread of COVID-19 virus because the COVID-19 virus is primarily transmitted to people through respiratory droplets and aerosol coming out as their coughing. This study is conducted on the air flow pattern optimization in BL-3 mobile laboratory with various design specifications of position of air supply & exhaust port and particle source. Air flow patterns of ceiling supply-exhaust and ceiling supply-bottom side exhaust with particle source were determined to compare the impact of the infection prevention. CFD simulation was used to analyze for two air flow patterns and particle source position. Numerical results showed that air flow pattern of air conditioning system with ceiling supply-exhaust in a row is more effective than that of ceiling supply-bottom side exhaust air flow pattern in terms of infection prevention in biosafety mobile laboratory.
        4,000원
        3.
        2020.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The cooking-generated particles are major indoor sources of air pollution. Recently, the performance of the range hood is focused on particle removal performance. Range hood with an auxiliary air supply system can improve the fine and ultrafine particles removal efficiency by making a supply air during cooking activities. The particles were measured in the experimental building by varying ventilation types. Only operating range hood during the cooking activities was not enough to reduce the cooking-generated particles. Despite operating range hood systems, fine and ultrafine particle concentrations were maintained when cooking was finished. The range hood with a make-up air supply system can reduce the indoor particle concentration below background conditions when those systems were operated after cooking. In this study, the assessment of cooking-generated particle removal efficiency of the range hood with an auxiliary air supply system was conducted. The removal efficiency of ultrafine particles showed trends similar to the removal efficiency of fine particles.
        4,000원
        5.
        2019.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the characteristics of the heat flow on SA(supply air) side of the white smoke reducing heat exchange system according to the change of SA velocity were analyzed in the winter condition (outside temperature 0℃). Also, the mixing process of SA and the EA(exhaust air) is presented in the psychrometric chart to confirm the possibility of reducing white smoke. Solidworks flow simulation was used to analyze the heat flow on the heat exchange system under uniform conditions. As the inflow velocity of SA increased, the temperature of SA decreased due to the convective heat transfer improvement due to the active flow in SA system. And the outlet temperature and absolute humidity of the mixing zone decreased significantly. At SA velocity 7 m/s, the outlet temperature and absolute humidity decreased to about 58% and 82%, respectively.
        4,000원
        6.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The drinking water supply system applicable to the laying hen consists of air-water heat pumps, drinking water tanks, heat stroage tank, circulation pumps, PE pipes, nipples, and control panels. When the heat pump system has power of 7.7 to 8.7 kW per hour, the performance coefficient is between 3.1 and 3.5. The supply temperature from the heat pump to the heat stroage tank was stabilized at about 12±1°C, but the return temperature showed a variation of from 8 to 14°C. Stratified temperature in the storage tank appeared at 12.°C, 13.5°C and 14.4°C, respectively. The drinking water supply temperature remained set at 15°C and 25°C, and the conventional tap water showed a variation for 23°C to 30°C. As chickens grow older, the amount of food intake and drinking water increased. y = -0.0563x2 + 4.7383x + 8.743, R2 = 0.98 and the feed intake showed y = -0.1013x2 + 8.5611x. In the future, further studies will need to figure out the cooling effect on heat stress of livestock.
        4,000원
        10.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        선박의 기계식 환기시스템은 화재발생 시 연기의 생성과 확산 특성에 영향을 미치고, 이는 피난자의 피난경로 상의 가시도를 방해함으로써 피난자의 연기로 인한 피해를 증가시킬 위험성이 크다. 이에 이 연구에서는 선박 거주구역에서 화재발생 시 기계식 급·배기시스템이 연기확산에 미치는 영향과 위험성에 대하여 FDS를 활용하여 평가하고 화재 시 급·배기시스템을 효율적으로 사용할 수 있는 방안을 제안하였다. 연구결과 화재가 발생한 장소에 급·배기시스템이 함께 작동되고 있는 경우에는 현재 권장되고 있는 급·배기시스템을 멈추는 방법보다 작동을 유지하는 것이 효과적이고, 배기시스템만 작동되는 곳에서 화재가 발생한 경우에는 화재가 발생한 구역 이외의 구역에서 급기시스템을 함께 작동시키는 것이 피난시간을 확보하는데 효과적인 것으로 예측되었다. 그러나 화재가 발생한 곳에 급기시스템만 있는 경우에는 급기시스템이 연기확산을 가속시키기 때문에 급기방식을 중단시켜 연기의 확산을 최대한 억제할 필요가 있음을 확인하였다.
        4,000원
        12.
        2016.05 구독 인증기관·개인회원 무료
        가스생산기지의 탱크보수와 가스배관 기밀시험 및 가스치완에 사용되는 질소 는 액화질소를 기화시켜 공급하고 있으며, 불활성 가스인 질소의 용도는 천연가스 설비에서 선박용까지 그 사용처가 다양하다. 질소발생기술은 극저온증류식, 흡착식, 분리막식이 있으며 극저온증류식은 장치비가 높아 대형플랜트에 적합하고 흡착식 및 분리막식은 중소규모에 적합하다. 특히, 분리막식은 기체의 투과 속도 차이를 이용한 분리공정으로 상변화가 수반되지 않아 에너지 절약형이고, 운전 및 제어가 용이하며, 시스템 설치에 필요한 공간이 간소하여 산간지역 및 도서지역 등 장소가 협소한 경우에 적용이 가능한 특성을 가진다. 본 연구는 이러한 분리막식의 특성을 활용하여 도서지역 내 LNG공급설비에 사용되는 질소 및 IA 공급시스템의 적용여부를 확인하였다.
        13.
        2014.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        For more efficient air-conditioning in large scaled vessels, structure of air inlet room and location of supply fan are very important. In this study, we have modeled an air intake room of large scaled vessels and tried to examine surrounding flow characteristics around supply fan by a numerical simulation using computational fluid dynamics based on three dimensional steady-state Navier-Stokes equation and standard k-ε model. A commercial CFD program, FLUENT, is used on the analysis. Finally, the analysis showed that the supply fan should be located at the inner side rather than outer side of air intake room, which was original design
        4,000원
        14.
        2014.02 구독 인증기관·개인회원 무료
        In this study, numerical simulation has been conducted to investigate flow characteristics in air supply room for container vessels by a 3-dimension numerical simulation. A commercial CFD program, FLUENT, is used on the analysis. It is shown that the air supply efficiency in this room can be improved by changing position of axial fan, even though other conditions still remain unchanged.
        15.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper dealt with FMEA, which is a method of the analysis to secure safety and confidence coming up to customers' expectation in consideration of the environment of the corporation, the industrial environment, and the functional improvement. And by using FMEA, We showed the example analyzed the confidence of the Air Supply System. It was proved by the result of the analysis that the rate of the breakdown which is usually regarded as the first important point to reform can't satisfy the selecting basis to improve. Also the result said that it is not right to depend on only the rate of the failure in making the list of the reform. Through the analysis of the breakdown, FMEA can present the important factors of the reform to improve the confidence of the system. In this study would show the important factors of the improvement in order to product the goods guaranteed confidence through the method of FMEA.
        4,000원