검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 12

        1.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study aimed to analyze adult men’s body sizes and shapes and suggest size specifications to provide preliminary data to academia and industries. A total of 814 adult men aged 30-44 were selected from the 7th Size Korea data, and 55 direct upper body measurement and calculation items were analyzed using SPSS 25.0. In individual Individual differences, thickness, circumference, and width were high, and height and length were low. Height above the waist base line and shoulder dimension decreased in early 40s age group, while height below the waist base line declined as age increased. In addition, buttocks shape changes were found in early 40s age group. According to factor analysis, ‘upper body and upper-extremity horizontal size’, ‘torso height and upper extremity length’, ‘shoulder dimension’, ‘upper body length’ and ‘shoulder angle’ were derived. Using clustering analysis, four different body types were classified: i) big abdomen with flat chest, ii) slender with big, raised shoulders, iii) dwarfish with small, droopy shoulders, and iv) obese with large shoulders. ‘Slender with big, raised shoulders’ was a typical body shape among men aged 30-44. In older participants, the ‘big abdomen with flat chest’ ratio was low, while ‘obese with large shoulders’ was more common. This study proposed size specifications by body type considering the above characteristics.
        6,000원
        3.
        2021.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        메기 (Silurus asotus)를 대상으로 210일간 기아 시 계측 형질 및 체 절단면 형질을 측정하여 그 기아 효과를 조사하였다. 실험 종료시 섭이군의 생존율은 92.2±0.47% 였으며, 기아군에서는 74.4±2.59%의 생존율을 보였다. Ls, DALPO/Ls, DADOP/Ls, ED/Ls, CH/Ls, BDAA/Ls, BDMA/Ls 및 BWAA/Ls의 8개 항목에서 유의한 차이를 보 였으며 (p<0.05), 다른 16개 항목 DALAD/Ls, DPDPL/ Ls, HPLAA/Ls, HALAV/Ls, HALOP/Ls, DAUPO/Ls, DADAV/Ls, DADAA/Ls, Max BL/Ls, Man BL/Ls, LD/Ls, HWOP/Ls, DAUF/HL, DAUS/HL, IW/HL 및 DAUE/HL 에서는 초기군, 섭이군 및 기아군의 세 그룹 간 유의한 차이가 없었다 (p>0.05). 섭이군은 각 체 절단면에서 기아군 보다 더 높은 전체 높이 (THX), 더 넓은 너비 (WX) 및 더 넓은 면적 (AX)을 보였다. 본 연구는 메기의 기아 상태에 대한 외형 및 체 절단면 형질에 대한 정보를 제공한다. 이는 메기에 대한 먹이 조절에 대한 방법을 보조하고 영양상태를 나타내는 기본 기초자료로 활용될 수 있을 것이다. 또 한, 본 연구에서 사용한 조사 분석 방법을 타 어종에서 적용 시 그 영양 상태에 대한 정보를 파악하는 데 유용하게 활용될 수 있을 것으로 사료된다.
        4,500원
        4.
        2019.12 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        이 연구는 D시에 근무하는 공무원 998명(남성:615명, 여성:383명)을 대상으로 체형분석을 통해 체형 불균형 정도를 평가하고자 하였다. 이 연구에 참여한 연구대상자의 직장근무경력은 남성 21.1±8.4년, 여성 18.5±9.6년이며, 평균연령은 남성:47.4±7세; 여성:43.8±8.4세이다. 연구 결과로 통증이 있거나 좋지 않은 부위가 있는 남성은 416명으로 전체 남성의 67.6%, 여성은 297명으로 전체 여성의 77.5%로 여성 직원이 남성 직원보다 약 10%정도 높은 비율로 근골격계 통증을 호소하고 있었다. 또한, 규칙적인 운동을 하고 있는 직원은 남성 293명(47.6%), 여성 168명(43.9%)으로 조사되었다. 정적체형 측정(관 상면, 시상면) 결과 통증이 있는 남성 416명 중 비운동자 322(52.4%)명의 목의 긴장도를 살펴본 결과 4.54±2.6kg이었고, 통증이 있는 여성 297명 중 비운동자 215명(56.1%)의 목의 긴장도는 2.47±1.5kg로 나타났다. 이러한 연구 결과를 토대로 오랫동안 앉아서 근무하는 대표적인 직업형태인 공무원은 자세 습관, 운동습관 등이 일자목과 같은 체형불균형에 상당 연관성이 있으며 이러한 체형불균형은 근골격 계 질환에도 영향을 미칠 수 있다는 것을 확인할 수 있었다.
        4,000원
        5.
        2016.05 구독 인증기관 무료, 개인회원 유료
        The measuring equipment capable of thermo measuring of wide range thermo range(0℃ ~ 160 0℃) will be developed in a high temperature and high pressure state. The developed technology is a combination of one measuring two different temperatures measured in the measuring to a high temperature as possible at a low temperature from thermocouple module(thermocouple) to develop an integrated measuring device capable of measuring the broadband. Also, to develop two or more guard module to ensure the water-tightness and durability of the device to develop in a vacuum or high pressure is applied to the one-piece measuring device.
        4,000원
        6.
        2015.06 구독 인증기관·개인회원 무료
        Measuring body size with a 3D scanner can reduce inter-measurer variability and provide better accuracy compared to using a traditional methods of measurement (Park, Nam, & Park, 2009). Many size measurement projects (or studies) that measure body size established a size measurement method prior to the development of a 3D scanner and automatic size measurement programs that produce 3D virtual body size measurements (Park, &Nam, 2012). Size data measured through an automatic size measurement program are more accurate and have a lower variability that is more appropriate for body measurements (Han, & Nam, 2004; Nam, Choi, Jung, & Yun, 2004). However, this method is limited to healthy subjects who can maintain a correct posture in a 3D scanner. It is difficult for the elderly to maintain the correct posture for body measurements in ‘Basic Human Body Measurements for Technological Design’ of ISO 7250(1997). Body measurement definitions are based on vertical and horizontal directions consequently, it is hard to measure those with a bent body type even if they stand in a correct posture. Most body measurement items are automatically measured in vertical and horizontal directions because current automatic size measurement programs utilize algorithms based on typical body measurement definitions. The size measurement method based on a vertical and horizontal directions tends to have a problem for elderly individuals with a bent body type who have difficulty maintaining a correct posture for 3D scanning as defined in ISO 7250(1997)(Ashdown, & Na, 2008).This study analyzes the problem of present auto-measurement programs that use elderly’s 3D body scan data. We conducted a comparative analysis of elderly’s body sizes using an auto-measurement program from virtual 3D body scan data and direct measurement with traditional measurement methods. We establish 34 typical body size measurements for the use of data from 464 males and 472 females (total 936) between the ages of 70 to 85. For error analysis, data separated to normal values and outliers compared with ISO 20655(2003). ISO 20685 defines the accuracy of extracted measurements by classification and measurement type (segment lengths, body height/breaths/depth, large/small circumferences, and head/hand/foot dimensions). The majority of outliers for the male and female body height type was “height”. Total number of persons with outliers for Height’s data was 603; consequently, 64.4% of subjects (elderly group of 70-85 yrs.) could not maintain a correct posture when scanning. Other data also had many errors from inaccurate measurement postures. A total of 72.3% of males and 70% of females have incorrect values in small circumferences. The segment lengths’ error data was 76.5% of males and 75% of females; in addition, the head dimension’ outliers were 87% for both male and female subjects. Especially 57.46% of males had incorrect data, while 74.67% of females had a type of large circumference. Female chest circumference had significant errors due to sagging breasts. The differences identify with a correlation between type of large circumference (chest, hip, under bust, waist, waist of omphalion) and gender. There were several correlations between the many measurement errors because values over 70% of data have outliers; however, each measurement type has properties in regards to correlation. A substantial positive correlation was found between all measurements (except hip circumference) in the type of large circumference; in addition, one-way ANOVA indicated that the measurements influenced height and were statistically significant. Outliers found in height data for the elderly’s were more likely to have errors in the type of large circumference. The type of body height indicated a strong correlation and statistical significance between the axilla height and other measurements (height, waist, crotch, lateral malleolus). Axilla height with more outliers indicated that other type of body height measurements had a higher potential for errors. The posture for body measurement was standardized as standing erect; however, this study indicated that many measurement errors were possible between using an auto-measurement program and direct measurement. The value of outlier about a particular measurement item can expect increased errors about any group (height: large circumference group/ axilla height: body height group). We have to study the relation in measurements in these types ‘large circumference’ because ‘head dimensions’ types correlate between measurements in each group. We need a more detailed analysis about outliers to find the major factors for measurement errors in regards to the elderly as well as discuss the possibility of ISO measurement-standard’s application for the elderly.
        7.
        2007.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 체성분 측정용 스마트 의류의 프로토타입을 개발하고 평가함으로써 헬스케어 의류로써의 개발 가능성을 탐색하고자 하였다. 직물 전극을 사용하여 개발된 두 가지 타입의 실험의복을 피험자에게 착용하도록 한 후 자세의 변화 및 1차 착용, 탈의 후 2차 착용에 따른 체성분을 측정한 결과, 동일 자세 내에서와 탈의 후 재착용 시에도 비교적 일관성 있는 측정치를 얻을 수 있었으며, 동일 자세에서는 의복 유형 및 반복 착용에 관계 없이 비교적 일관된 임피던스 측정치를 얻을 수 있었다. 또한 착용자의 신체 부위별 측정도 가능한 것으로 분석되어 향후 본 연구를 바탕으로 체성분 측정용 스마트 의류 개발이 가능할 것이라 판단된다.
        4,000원
        9.
        2003.05 구독 인증기관 무료, 개인회원 유료
        인체측정 시, sheet를 이용한 계측치 기록에 의한 직접측정 방법은 계측치 입력시간이 오래 걸리고, 입력과정에서 착오가 생길 수 있다. 따라서 본 연구는 계측치 입력과정에서 발생할 수 있는 착오를 감소시키고, 계측 소요시간을 단축시키기 위해 샅높이 항목과 큰․작은․둥근 수평자 항목에서의 인체측정 실시간 입력 프로그램을 개발하였다. 본 시스템은 인체측정과 동시에 입력 화면에 계측치가 실시간으로 입력되고, 모든 항목의 측정을 마치면 자동으로 각 피험자명으로 저장된 Excel파일과 Access DB가 생성된다. 남녀피험자 50명을 대상으로 새롭게 개발한 인체측정 실시간 입력 프로그램을 사용하여 계측을 실시한 결과 sheet를 이용하는 기존 Martin식 계측법과 비교하여 샅높이 항목과 큰․작은 수평자를 사용하는 항목에서 유의한 시간 절감 효과를 확인할 수 있었다.
        3,000원