This study aims to propose a simplified equation for estimating the bond strength of corroded reinforcing bars. To this end, extensive parametric analyses were performed using the detailed analysis method presented in the authors’ previous study, where a wide range of critical variables were considered, such as compressive strength of concrete, net cover thickness, and reinforcing bar diameter. The sensitivity in bond strength of the corroded reinforcing bar according to each variable was evaluated. On this basis, a simplified formula for the bond strength of the corroded reinforcing bar was derived through regression analysis. The proposed equation was rigorously tested and verified using the bond test results of corroded reinforcing bars collected from the literature. The results confirmed that the proposed equation could estimate the bond strengths of specimens with better accuracy than the existing models, providing a reliable tool for engineers and researchers. In addition, the proposed equation was used to analyze the development length required for corroded tensile reinforcement to exert its yield strength, and it showed that the cover thickness of concrete must be at least four times the diameter of the reinforcing bar to achieve the yielding strength of reinforcing bar even at a corrosion degree of more than 5.0%.
철근은 콘크리트와 결합하여 인장 능력을 보완하고 표면 피막으로 부식을 방지하지만, 탄산화 및 염화물 침투로 인해 부식이 발생하면 내력이 저하된다. 이를 해결하기 위해 내부식성이 뛰어난 GFRP(Glass Fiber Reinforced Polymer) 보강근이 철근 대채제로 주 목받고 있다. 본 연구는 직경에 따른 GFRP 보강근의 부착특성을 철근과 실험적으로 비교 분석하였다. 콘크리트는 약 39MPa의 고강도 에 가까운 콘크리트를 사용하였으며, 보강근의 직경은 D10과 D13을 사용하였다. 실험 결과, GFRP 보강근의 평균 부착 응력은 17.21MPa로 철근의 18.14MPa와 유사하게 나타났다. GFRP 보강근의 슬립 양은 3.05mm로 철근의 1.53mm 보다 크게 나타났다. 또한 GFRP의 경우 인발 과정에서 표면에 국부손상이 발생하는 것을 확인하였다.
RC구조물에서 대부분의 인장력을 받는 철근은 다양한 환경에 노출되었을 때 부식이 발생하며, 이러한 철근의 부식은 인장력 감소와 더불어 철근의 주변에 존재하는 콘크리트 균열 크기를 확장시켜 RC 구조물의 수명을 단축시키는 주요한 원인으로 작용하고 있 다. 이로인해 건축물의 유지 관리에 많은 비용이 필요하게 되며, 과도한 구조물의 유지, 관리 비용은 건설 분야의 문제점으로 남아있 다. 탄소섬유 강화 폴리머(CFRP)는 내화학성(비부식) 특성과 중량 대비 높은 강도로 인해 철근을 대체할 수 있는 보강제로 주목받고 있으며, CFRP보강재의 높은 항상성은 위에 대두된 구조물의 유지 관리 비용을 크게 절감할 수 있을 것이라 판단되어 연구되어지고 있다. 본 논문에서는 다양한 건설 분야에서 CFRP 보강재를 사용하기 위한 과정 중 CFRP 그리드를 내부 보강제로 사용하기 위한 연구로써 CFRP 그리드와 콘크리트의 부착 특성을 실험을 통해 연구하였다. 이를 위해 다양한 정착 길이를 가진 30개의 콘크리트 부착 시편에 대해 인발 시험을 수행하였으며, 실험 결과를 바탕으로 콘크리트에서 CFRP 그리드의 부착 특성을 분석하고 콘크리트 구조물의 보강재 로 CFRP 그리드를 적용하기 위한 분석 공식을 제안하였다.
The paper presents the experimental investigation of RC beams retrofitted with Textile Reinforced Mortar (TRM), featuring enhanced bond capacity. Anchoring systems, including an extension of retrofitting length and the use of chemical anchors, are newly employed to improve the structural performance of the RC beam retrofitted with TRM. For the experimental investigation, a total of seven shear-critical RC beams, with and without stirrups, were designed and constructed. The structural behaviors of specimens retrofitted with the proposed TRM methods were compared to those of non-retrofitted specimens or specimens strengthened with conventional TRM methods. Crack pattern, force-displacement relationship, and absorbed energy were evaluated for each specimen. The experimental results indicate a significant improvement in the shear capacity of the RC beam with the proposed retrofitting method. Therefore, it is concluded that the application of an extended retrofitting length and chemical anchors to the TRM retrofitting method can effectively enhance the bond capacity of TRM, thereby improving the shear performance of RC beams.
택코트란 아스팔트 포장 공사 시 기존 아스팔트층과 신설 아스팔트 층 사이에 부착성을 증가시키기 위하여 사용되는 재료이다. 교통 하중으로 인해 포장 경계면에서 수평전단응력 및 수직인장응력이 발생하게 되는데 택코트의 유실, 양생 부족 등의 문제로 접착 성능 이 부족하면 포장층의 분리, 밀림과 같은 도로 파괴가 형상이 나타날 수 있다. 현재 국내에서는 국토교통부 아스팔트 콘크리트 포장 시공 지침에 택코트 살포량에 대한 기준은 존재하지만 기존 및 신설 아스팔트 포장층 사이에 택코트의 접착강도에 대한 기준은 존재 하지 않는 실정이다, 이는 접착강도 특성이 분석되지 않은 택코트를 사용함에 따라 아스팔트 포장의 공용성 측면에서 문제를 초래할 수 있다. 따라서 본 연구에서는 PG등급이 다른 택코트 4종류에 대한 인장 및 전단접착강도를 확인하기 위하여 인장접착강도 시험, 전 단접착강도 시험을 진행하였다. 택코트의 양생정도에 따른 접착강도 특성을 확인해보기 위하여 택코트의 수분이 증발됨에 따라 중량 변화가 없는 상태를 양생 100%로 하여 양생 0%, 50%, 100%로 진행하였으며, 살포량은 국토교통부 아스팔트 콘크리트 시공 지침에 따 라 0.5ℓ/m2로 진행하였다. 사용된 택코트 종류에 관계 없이 양생 정도가 증가함에 따라 접착강도는 증가하는 추세를 보였으며, 인장 및 전단접착강도 시험에 관계없이 초기 양생(양생 0%~50%)보다 양생 50% 이후에서의 더 높게 강도가 발현된 것을 확인하였다. 또한 PG등급이 높은 택코트가 인장 및 전단접착강도에 관계없이 접착강도 성능이 우수한 것을 확인할 수 있었다. 추후 택코트의 종류를 추 가하여 PG등급이 분류가 이루어진 후에 접착강도 시험을 진행하여 결과를 확인할 예정이다.
본 연구에서는 글로벌 회사채 포트폴리오의 신용위험(부도확률지표)에 대한 신용스프레드(OAS: 시장지표)의 선행성 여부 및 선행성 정도를 분석하였다. 두 지표를 회귀변수로 하는 시차상관성 분석 및 패널 회귀분석 결과 회사채 신용위험에 대해 시장지표가 유의한 선행성을 갖는 것으로 나타났다. 이는 시장을 통해 신용위험 변화를 실시간 반영하는 시장지표가 해당 회사채의 신용위험 변화를 빠르게 포착하기 때문으로 풀이된다. 일일 데이터로 측정한 시장지표의 신용위험 시그널링 효과는 신용스프레드가 대체로 0.5개월 이후의 부도확률 악화를 가장 잘 설명하는 것으로 나타났다. 시장상황에 따라서도 선행성의 크기가 달리 나타났는데, 시장스트레스 시기일수록 높 은 변동성으로 인해 신용위험 변화에 시장지표가 더 민감하게 반응함으로써 동 시그널링 효과가 더 큰 것으로 분 석되었다. 금융복합성 증가 등으로 시장위험과 신용위험간 경계가 모호해지는 최근 흐름을 감안할 때 시장지표의 활용을 통해 신용리스크관리의 선제적 대응력을 높일 필요성이 더욱 커졌으며, 특히 시그널링 효과가 큰 시장스 트레스기 일수록 시장지표의 활용에 무게를 둘 필요가 있다.
본 연구는 실내실험 및 수치해석을 적용하여 GFRP 보강근의 콘크리트 휨 및 인발 부착성능을 분석하였다. 부착길이 변화에 대하여 철근 또는 GFRP로 보강된 콘크리트 보의 하중-변위 곡선을 도출하였다. 또한, 두 타입의 근에 대하여 인발 실험 을 수행하였다. 다음으로 3차원 유한요소 해석을 통하여 실험 결과를 검증하였다. 본 연구로부터 도출은 결과는 GFRP 보강근이 철근을 대체하는 휨 및 인발 부착 성능을 보유하고 있음을 보여 준다.
Existing reinforced concrete building structures constructed before 1988 have seismically-deficient reinforcing details, which can lead to the premature failure of the columns and beam-column joints. The premature failure was resulted from the inadequate bonding performance between the reinforcing bars and surrounding concrete on the main structural elements. This paper aims to quantify the bond-slip effect on the dynamic responses of reinforced concrete frame models using finite element analyses. The bond-slip behavior was modeled using an one-dimensional slide line model in LS-DYNA. The bond-slip models were varied with the bonding conditions and failure modes, and implemented to the well-validated finite element models. The dynamic responses of the frame models with the several bonding conditions were compared to the validated models reproducing the actual behavior. It verifies that the bond-slip effects significantly affected the dynamic responses of the reinforced concrete building structures.
This study examined the previous studies and reviews on the impact of human animal bond (HAB), a coevolutionary relationship between human and animal, in trauma recovery. The most important factor in recovering from trauma is making a good relationship; human animal bond can act as a positive aspect in making such relationship. Animals give a sense of support and safety which leads to making a trustful relationship. It has also been proven HAB can lessen one's loneliness and anxiety. For these reasons, Animal Assisted Therapy (AAT) is widely used in trauma recoveries.
PURPOSES : On a thin epoxy overlay pavement, epoxy is placed on the existing bridge deck pavement, followed by the spraying of aggregates on it. The bond strength between the existing pavement and overlay pavement is an important factor representing the performance of the thin epoxy overlay pavement, in addition to the skid resistance and roughness. Therefore, the bond strength, skid resistance, and roughness of a thin epoxy overlay pavement constructed for field tests under various field conditions are examined in this study.
METHODS : The usability of epoxy and aggregates on a thin epoxy overlay pavement is identified by testing their material properties in a laboratory. A construction test is performed using the pretreatment conditions of the existing pavement surface and the number of layers of overlay pavement as variables. The bond strength, skid resistance, and roughness are analyzed 3 d after constructing the test pavement, and immediately before and after applying repetitive traffic loadings at 6 months.
RESULTS : When the existing pavement is in good condition, as in this study, the bond strength of the thin epoxy overlay pavement is affected more significantly by the existing pavement condition than the material properties of epoxy, in which destruction is indicated in the existing pavement. The skid resistance is affected primarily by the condition of the aggregates sprayed on the epoxy. The pavement on which the aggregates are well sprayed indicate a high skid resistance. The roughness is not affected by any variables, such as the pretreatment conditions, number of thin pavement layers, and repetitive traffic loadings.
CONCLUSIONS : A long-term evaluation of the bond strength, skid resistance, and roughness will be conducted on a test pavement. In addition, another construction test will be performed to investigate the performance of a thin epoxy pavement overlaid on a bridge deck pavement under inferior conditions.
The oxidation resistance of the diffusion aluminide bond coat (BC) is compromised largely by interdiffusion (ID) effects on coated turbine blades of aeroengines. The present study is designed to understand the influence of ID on βNiAl coatings or BC. In this regard, nickel substrate and CMSX-4 superalloy are deposited. In total, four sets of BCs are developed, i.e. pure βNiAl (on Ni substrate), simple βNiAl (on CMSX-4 substrate), Zr-βNiAl (on CMSX-4 substrate) and Pt-βNiAl (on CMSX-4 substrate). The main aim of this study is to understand the interdiffusion of Al, Zr and Pt during preparation and oxidation. In addition, the beneficial effects of both Zr and platinum are assessed. Pure βNiAl and simple βNiAl show Ni-outdiffusion, whereas for platinum inward diffusion to the substrate is noticed under vacuum treatment. Interestingly, Zr-βNiAl shows the least ID in all BCs and exhibit stability under both vacuum and oxidation treatments. However, its spallation resistance is slightly lower than that of Pt-βNiAl BC. All BCs show similar oxide growth trends, except for Zr-βNiAl, which exhibits two-stage oxidations, i.e. transient and steady-state. Moreover, it is suggested that the localized spallation in all BCs is caused by βNiAl - γ’-Ni3Al transformation.
철근의 부식 문제를 해결하기 위해 최근 복합재료 기반의 철근이 개발되어 사용되고 있으며 CFRP 그리드도 개발되어 구조부재로 사용되기 시작하고 있다. 그러나 CFRP 그리드의 부착 특성과 응력을 연구한 경우는 매우 드물다. 이에 본 실험은 CFRP 그리드의 부착거동, 부착응력을 평가하고 정착길이를 산정하기 위해 다양한 길이의 정착길이를 가진 인발실험체를 제작한 후 인발하였으며 실험 결과 부착력의 경우 정착길이가 길어질수록 커지며 반대로 부착응력은 정착길이가 길어질수록 작아지는 결과를 얻을 수 있었다. 이는 FRP 보강근도 같은 경향을 보이지만 CFRP 그리드와 FRP 보강근의 차이점은 부착응력의 추세선의 경향에서 두드러지며 또한, 최대 부착력 이후 거동에서 차이를 나타냈다. 위 실험 결과를 토대로 CFRP 그리드의 정착길 이를 산정한 결과 본 연구에서 사용된 CFRP 그리드의 보수적인 정착길이는 250mm로 나타났다.
최근 정부에서는 전자적 대금지급시스템을 고도화하여 건설 현장에서 체불을 해결하고 양질의 일자리를 창출하고자 방안을 모색하고 있다. 그러나 아직까지 논의 되고 있는 방안은 다단계 하도급을 구성하는 발주자-수급인-하수급인-노무자, 자재·장비업자 사이의 직접 지급 합의를 통한 대금지급시스템의 적용 수준에 머물러 있다. 이렇게 직접 지급 합의를 통한 대금지급시스템의 고도화는 신속한 공사대금 지급을 할 수 없을 뿐만 아니라 체불 및 하도급대금의 미지급 위반 등의 하도급법 위반 문제까지 해결하기 어려울 것으로 본다. 이에 대금지급시스템에 민간 건설 현장에 시범적으로 적용되고 있는 공사대금 채권신탁 방안을 보완 적용 함으로써 공사대금 채권 가압류 및 정산분쟁 등으로 인해 발생되는 다수의 대금 지급시스템의 문제점을 해결함으로써 건설 현장 관련 이해관계인 모두가 동반성장 상생 협력하는 공정한 문화를 정착해 나가야 한다.
PURPOSES : Given that large-scale repair works of expressway bridge pavements have high maintenance cost and long traffic blocking time, the thin overlay method that maintains the existing pavement is attracting attention. In this study, because the bridge thin overlay has not been introduced in Korea yet, the basic physical properties of the epoxy thin overlay, which is mainly used for the bridge thin overlay, were investigated, and the skid resistance and bond performance were analyzed.
METHODS : Basic physical property tests were performed on each of the epoxy binders, aggregates, and mixtures used in epoxy thin overlay. They were also compared and reviewed against foreign standards. The epoxy binders were tested for viscosity, gel time, and thermal compatibility. The aggregates were tested in terms of water absorption, specific gravity, and gradation. The compressive and flexural strengths of the mixtures were investigated. The epoxy thin overlay has the possibility of detachment of aggregates, so the skid resistance was tested according to the paving phase. In addition, to investigate the bond performance, which is the most important performance of the epoxy thin overlay, the bond strength test was performed by varying the moisture condition and treatment condition of the existing layer surface.
RESULTS : The basic physical properties of the materials used in the epoxy thin overlays satisfied foreign standards except for the gradation of aggregates. The skid resistance did not satisfy the standard when the epoxy was exposed, whereas the skid resistance did satisfy the standard when the aggregates were exposed, even after the abrasion test. The bond strength of the epoxy thin overlay satisfied the standard in all cases. The bond strength was the highest when the relative humidity of the existing layer surface was 60%.
CONCLUSIONS : The materials of epoxy thin overlay that could be obtained in Korea satisfied the basic physical property standards except for aggregate gradation. Given that the aggregate gradation could be adjusted, it can be concluded that the epoxy thin overlay could be introduced in Korea. In addition, it was confirmed that the skid resistance and bond strength of the epoxy thin overlay were high enough to be used in general road conditions. It was determined that the existing layer surface should maintain an optimal relative humidity of approximately 60% because the moisture condition affects the bond strength.
철근콘크리트 기둥에서 후프철근의 내진갈고리 시공성을 개선하기 위하여 기존 연구에서 “띠철근 갈고리 뽑힘 방지 장치”인 RCC장치(Rebar Confinement Clip)를 제안하여 인발실험을 통한 부착 및 정착성능 실험을 실시하였다. 그러나, 기존 연구의 실험에서는 콘크리트 구조기준에서 제시하는 피복두께를 준수하지 않았다. 그러므로, 보다 신뢰성 있는 실험 결과를 도출하 기 위하여 기준에서 제시하는 피복두께를 준수한 실험체로 실험을 실시할 필요가 있다. 이를 위하여 총 6개 실험체를 제작하여 실험을 실시하였으며 실험결과, 부착 및 정착의 합성강도는 RCC장치로 체결된 띠철근의 갈고리가 내진갈고리가 발휘하는 강도 보다 높게 나타났다. 또한, 내진갈고리의 실험체 균열 진전 및 파괴 양상과 RCC장치로 체결된 띠철근의 실험체는 유사하게 나타났다. 그러므로, 콘크리트 피복두께를 준수한 실험체에서 RCC장치로 띠철근에 체결할 경우 내진갈고리가 발휘하는 동등한 성능을 보유하고 있는 것으로 평가된다.