검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 147

        21.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this work, we studied the effects of electrochemical oxidation treatments of carbon fibers (CFs) on interfacial adhesion between CF and epoxy resin with various current densities. The surface morphologies and properties of the CFs before and after electrochemical-oxidation-treatment were characterized using field emission scanning electron microscopy, atomic force microscopy, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, and single-fiber contact angle. The mechanical interfacial shear strength of the CFs/epoxy matrix composites was investigated by using a micro-bond method. From the results, electrochemical oxidation treatment introduced oxygen functional groups and increased roughness on the fiber surface. The mechanical interfacial adhesion strength also showed higher values than that of an untreated CF-reinforced composite.
        4,000원
        23.
        2016.04 구독 인증기관·개인회원 무료
        The clamping of torque shear high strength bolt is induced when the pin-tail is broken. However the tension forces induced shank of the bolt do not be known by now. This study focused to develop a quantitative method to identify the induced tension by analyzing the electric energy of which electric torque wrench (rpm 20) was applied to high strength bolt at the break of pin tail. Based on this co-relation between tension and accumulated current, the regressive analysis was derived. The error rate between tension and accumulated current was 5.06%.
        24.
        2016.04 구독 인증기관·개인회원 무료
        The clamping of torque shear high strength bolt is induced when the pin-tail is broken. However the tension forces induced shank of the bolt do not be known by now. This study focused to develop a quantitative method to identify the induced tension by analyzing the electric energy of which electric torque wrench was applied to high strength bolt at the break of pin tail. Based on this co-relation between tension and accumulated current, the regressive analysis was derived. The error rate between tension and accumulated current was 2.24%.
        25.
        2016.04 구독 인증기관·개인회원 무료
        철근콘크리트 슬라브의 휨강도 보강을 위해 제안된 섬유보강폴리머(Fiber Reinforced Polymer, FRP)와 초 고거동 콘크리트(Ultra High Performance Concrete, UHPC)의 합성구조의 파괴 시 거동을 살펴 본 결과, 과다한 휨 보강으로 인한 전단파괴와 보강된 FRP의 탈착에 의한 파괴가 발생하였다. 전단강도와 휨 강도의 크기를 고려한 설계 기준을 제시하여 휨 보강 한도를 제한하고, 전단 철근을 추가하여 탈착에 의한 파괴를 보강하였다. 휨 강도의 보강을 제한 하고 부착 철근이 보강된 슬라브의 실험 결과, 휨에 의한 연성파괴가 유도되었다.
        26.
        2016.04 구독 인증기관 무료, 개인회원 유료
        Concrete has been widely used for material of bridge girder. However, Concrete is considered as inefficient material for long-span girder. Because it has low material strength compared with those of steel girder, huge cross sectional area are required to have same strength of steel girder bridges. UHPC(Ultra High Performance Concrete) as new material is developed to supplement this weakness of concrete. UHPC has high compressive strength and show softness behavior due to it is reinforced by fiber. If UHPC has no any reinforcement for shear, diagonal tension crack failure is dominant like normal concrete. So, reinforcement for shear is essential and prestress is efficient method of reinforcement for UHPC due to high compressive strength. However, design equation for shear strength suggested by K-UHPC Certification(2012) do not consider prestress effect. Therefore, this study investigate effect of prestress for shear strength of ultra high performance concrete I-girder by using finite element analysis program
        3,000원
        27.
        2016.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In the present study, exfoliated graphite nanoplatelets (xGnP) with different particle sizes were coated onto polyacrylonitrile-based carbon fibers by a direct coating method. The flexural properties, interlaminar shear strength, and the morphology of the xGnP-coated carbon fiber/phenolic matrix composites were investigated in terms of their longitudinal flexural strength and modulus, interlaminar shear strength, and by optical and scanning electron microscopic observations. The results were compared with a phenolic matrix composite counterpart prepared without xGnP. The flexural properties and interlaminar shear strength of the xGnP-coated carbon fiber/phenolic matrix composites were found to be higher than those of the uncoated composite. The flexural and interlaminar shear strengths were affected by the particle size of the xGnP, while the particle size had no significant effect on the flexural modulus. It seems that the interfacial contacts between the xGnP-coated carbon fibers and the phenolic matrix play a role in enhancing the flexural strength as well as the interlaminar shear strength of the composites.
        4,000원
        28.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문은 넓은 보의 전단강도를 대상으로 한 실험적 평가에 대해 기술하였다. 본 논문의 실험을 통해 넓은 보에 횡방향 단면에서 GFRP 판의 보강개수와 종방향 전단보강 간격, 그리고 유효깊이가 전단강도에 끼치는 영향에 관하여 연구하였다. 총 7개의 시험체에 유공형 GFRP 판 형태로 전단보강재를 보강하여 전단성능 실험을 실시하였다. 본 논문에 기재된 전단보강재는 유공형 판 형태로 제작되어 타설 시 콘크리트의 유동성을 증가시켜 보강재와 콘크리트의 부착력을 향상시켰다. 7개 시험체의 주 변수로는 전단보강재의 횡방향 단면에 대한 판의 보강개수와 종방향 전단보강 간격, 그리고 유효깊이로 정하였다. 시험체의 균열 및 파괴 양상, 변형률과 전단강도비를 분석하였다. GFRP판으로 전단보강된 넓은 보의 전단강도는 ACI 318-11 기준으로 산정되었다. 실험의 결과를 통해 유공형 GFRP 판이 전단보강재로서 넓은 보에 효과적으로 적용됨을 확인하였다.
        4,000원
        29.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, material tests were performed on the masonry specimens constructed with bricks and mortar used in Korea. The specimens included two types of thickness(0.5B and 1.0B) and physical conditions (good and poor). It was shown that 1.0B specimens have 3.2~1.8 times larger shear strength than 0.5B specimens and shear strength of specimens in poor condition was 66%~38% of those in good condition. Average shear stress of masonry-infills was calculated from previous experimental studies, and relationships with failure mode, material strength of masonry, aspect ratio, and frame-to-infill strength ratio were investigated. In addition, the effects of masonry strength on the seismic performance of a masonry-infilled frame was studied using a simple example building. It can be seen that the obtained average shear stress were considerably higher than the default masonry shear strength recommended by the ASCE 41, and low values the strength of masonry does not guarantee conservative evaluation results due to the early shear failure of frame members.
        4,000원
        30.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        UHPC(Ultra High Performance Concrete) is used widely with its remarkable performance, such as strength, ductility and durability. Since the fibers in the UHPC can control the tensile crack, the punching shear capacity of UHPC is higher than that of the conventional concrete. In this paper, seven slabs with different thickness and fiber volume ratio were tested. The ultimate punching shear strength was increased with the fiber volume ratio up to 1%. The shear capacity of specimens with the fiber content 1% and 1.5% do not have big differences. The thicker slab has higher punching shear strength and lower deformation capacity. The critical sections of punching shear failure were similar regardless of the fiber volume ratio, but it were larger in thicker slab.
        4,000원
        31.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Ultra High Performance Fiber Reinforced Concrete (UHPFRC) has a outstanding tensile hardening behaviour after a crack develops, which gives ductility to structures. Existing shear strength model for fiber reinforced concrete is entirely based on crack opening behavior(mode I) which comes from flexural-shear failure, not considering shear-slip behavior(mode II). To find out the mode I and mode II behavior on a crack in UHPFRC simultaneously, maximum shear strength of cracked UHPFRC is investigated from twenty-four push-off test results. The shear stress on a crack is derived as variable of initial crack width and fiber volume ratio. Test results show that shear slippage is proportional to crack opening, which leads to relationship between shear transfer strength and crack width. Based on the test results a hypothesis is proposed for the physical mechanics of shear transfer in UHPFRC by tensile hardening behavior in stead of aggregate interlocking in reinforced concrete. Shear transfer strength based on tensile hardening behavior in UHPFRC is suggested and this suggestion was verified by comparing direct tensile test results and push-off test results.
        4,000원
        32.
        2015.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This paper shows the test results of continuous reinforced concrete beams with external post-tensioning rods. Six three-span beams were prepared and tested to fail. Three beams were designed to have flexure-dominating behavior and the others to have shear-critical behavior. In each group, one beam without external post-tensioning rods was designated as a control beam and two beams had the external post-tensioning rods of 18 mm or 22 mm diameter. External post-tensioning rods were installed within an interior span of 6000 mm. They show V-shaped configuration because two anchorages were located at the top of interior supports and a saddle pin at mid-span was installed at the bottom of the beam. Test results show that the load and shear capacities of strengthened beams were increased when compared with the control beam. Additionally, the measured shear strength was compared with the strength predicted by ACI 318-11 code equations. The detailed ACI 318-11 equation predicted the measured shear strength and failure location of the continuous beam reasonably well.
        4,000원
        33.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Torque control method and turn of nut method are specified as clamping method of high strength bolts in the steel construction specifications. Quality control of torque coefficient is essential activity because torque control method, which is presently adopted as clamping method in domestic construction sites, is affected by variation of torque coefficient. The clamping of torque shear bolt is based on KS B 2819. It was misunderstood that the tension force of the TS bolt was induced generally at the break of pin-tail specified. However, the clamping forces on slip critical connections do not often meet the intended tension, as it considerably varies due to torque coefficient dependent on the environmental factors and temperature variables despite the break of the pin tail.This study was focused to evaluate the effect of environmental factors and errors of installing bolts during tightening high strength bolts. The environmental parameters were composed of 'wet' condition, 'rust' condition, 'only exposure to air' condition. And the manufacture of trial product was planned to identify the induced force into the bolts. The algorithm for a trial product was composed of the relation between electricity energy taken from torque shear wrench and tension force from hydraulic tension meter.
        4,000원
        34.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 유공형 형상의 GFRP 판으로 전단 보강된 플랫 플레이트의 전단거동을 실험을 통해 평가하였다. GFRP 판은 개구부가 있는 판의 형태로서 콘크리트와의 일체화 거동을 위하여 콘크리트에 매립하여 시공하였다. 실험 변수로는 기둥면과 첫 번째 GFRP 판의 세로 스트립 사이의 간격, GFRP 판의 세로 스트립의 개수를 선정하였다. GFRP 판의 세로 스트립의 개수가 증가할수록 전단강도도 증가하는 결과를 보여주었다. 실험결과를 바탕으로 GFRP 판으로 보강된 플랫 플레이트의 전단강도가 ACI 318, BS 8110, EUROCODE 2, KCI에서 제시하고 있는 전단강도와 비교하여 가장 합리적인 규준을 평가하였다.
        4,000원
        35.
        2014.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 논문에서는 새로운 형상의 GFRP 판으로 전단보강된 플랫 플레이트의 전단거동에 관하여 실험적으로 연구하였다. GFRP 판은 개구부가 있는 판의 형태로서 콘크리트와의 일체화 거동을 위하여 콘크리트에 매립하여 사용한다. 총 7개의 시험체에 대한 뚫림 전단실험을 수행하였고, 실험 변수로는 전단보강재의 종류와 전단보강량을 선택하였다. 실험결과를 시험체의 균열 및 파괴양상, 변형률, 하중변위곡선으로 분석하였다. 또한 GFRP 판으로 전단 보강된 플랫 플레이트의 ACI 318-11 기준식에 의한 계산값과 실험에 의한 결과값을 비교하였다. 실험 결과 GFRP 판이 플랫 플레이트의 전단보강재로써 뚫림 전단에 효과적으로 적용함을 확인하였다.
        4,000원
        36.
        2014.04 구독 인증기관·개인회원 무료
        Torque control method and turn of nut method are specified as clamping method of high strength bolts in the steel construction specifications. Quality control of torque coefficient is essential activity because torque control method, which is presently adopted as clamping method in domestic construction sites, is affected by variation of torque coefficient. This study was focused to evaluate the effect of environmental factors and errors of installing bolts during tightening high strength bolts. The environmental parameters were composed of 'wet' condition, 'rust' condition, 'only exposure to air' condition.
        37.
        2014.03 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The effects of printed circuit board electroless nickel immersion gold (ENIG) and organic solderability preservative (OSP) surface finishes on the electromigration reliability and shear strength of Sn-3.5Ag Pb-free solder bump were systematically investigated. In-situ annealing tests were performed in a scanning electron microscope chamber at 130, 150, and 170˚C in order to investigate the growth kinetics of intermetallic compound (IMC). Electromigration lifetime and failure modes were investigated at 150˚C and 1.5×105A/cm2, while ball shear tests and failure mode analysis were conducted under the high-speed conditions from 10 mm/s to 3000 mm/s. The activation energy of ENIG and OSP surface finishes during annealing were evaluated as 0.84 eV and 0.94 eV, respectively. The solder bumps with ENIG surface finish showed longer electromigration lifetime than OSP surface finish. Shear strengths between ENIG and OSP were similar, and the shear energies decreased with increasing shear speed. Failure analysis showed that electrical and mechanical reliabilities were very closely related to the interfacial IMC stabilities.
        4,000원
        38.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, flexural strength properties of SC shear walls were investigated through static pushover test. Failure modes and stiffness characteristics of SC shear walls under lateral loads were inspected by analyzing the experimental results. Main failures of unstiffened SC shear walls were found to be the type of bending shear failure due to the unbonding of the steel plate at the concrete interface. The ductility capacity of SC structures was also confirmed to be improved, which is considered to be a confining effect on steel plates in the longitudinal behavior of SC shear walls.
        4,000원
        39.
        2013.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        It is same such as the provision of shear buckling strength of steel composite box girder web panel and plate girder web panel in Korea Highway Bridge Design Standards(2012). But the web panel of steel composite box girder is different from the web of plate girder in that the upper slab and lower flange are connected to the web. So a different shear behavior of the girders is expected. In this study, To calculate a reasonable elastic shear buckling strength of steel composite box girder web panel, ABAQUS program was used. The results from F.E.A and previous studies are compared. It is shown that the web shear buckling strength of steel composite box girder of Korea Highway Bridge Design Standards(2012) is the most conservative.
        4,000원
        40.
        2013.08 구독 인증기관·개인회원 무료
        알루미늄 폼을 볼트나 너트를 이용하여 체결한다면 경량성이 감소되므로 접착제로 접합하는 것이 가 장 효율적이다. 이런 알루미늄 폼 접착 구조물에 대한 충격 피로 특성과 접착 합면에 대한 파괴인성 연 구는 매우 부족하며 또한 중요하다. 이에 따라 본 연구에서는 알루미늄 폼으로 만들어진 DCB모델을 접 착제로 접합한 후 두께를 변수로 하여 25mm 부터 45mm까지 10mm차이를 두어 실험과 컴퓨터 시뮬레 이션을 통하여 수행하였다. 실험은 MTS사의 인장 시험기를 사용하여 강제 변위 100mm를 주어 변위에 따른 전단력을 알아보았고, 실험과 똑같은 조건하에 ANSYS를 이용하여 유한요소해석을 수행하였다. 실험과 유한요소해석 값을 비교하여 접착제로 접합된 알루미늄 폼 구조물의 접착 합면에 대한 파괴인성을 고찰하였다.
        1 2 3 4 5