검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 308

        141.
        2013.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The objective of this study is to support an environmental policy related to the improved control of indoor airborne fungi in Korea. We reviewed 15 articles published in Korea to analyse the trend of airborne fungi level in indoor environment of various public facilities. The maximum mean concentrations of total airborne fungi in hospital and kindergarten were 1447 CFU/m3 and 1259 CFU/m3, respectively. We concluded that policy determination are urgently required to guide a proper management on airborne fungi in Korea.
        4,800원
        142.
        2013.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        This study investigated viability variation of airborne bacteria in indoor environments. The survival in air as a temporal function of bioaerosol viability was reported for Escherichia coli (KCCM 12119, ATCC 11775). Bacteria suspended in distilled water were aerosolized and entered the vertical duct oriented downward. After measurement of number concentration and colony forming unit (CFU) of the bacteria at different locations of the duct, the viability function was calculated. It was found that the bacteria viability(%) decreased with time after aerosolization, 28.454e-0.132x (x:time, min). This study demonstrated the potential application of viability function of airborne bacteria to studies of exposure assessment and infection risk analysis.
        4,000원
        143.
        2012.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        부유구조물은 해양에서 다양한 외력을 경험하게 되며 특히, 파랑하중은 구조물의 설계에 결정적인 지배인자로 간주되고 있다. 이런 구조물은 파장과 크기의 상대적 관계로 소형구조물, 대형구조물 등으로 구분될 수 있으며 전통적으로 소형구조물은 회절발생이 없는 것으로 가정하며 대형구조물은 회절 작용에 따른 관성력만을 고려하여 파랑하중을 산출한다. 따라서 이 연구에서는 해양과 강, 호수 등에서 주로 사용되고 있는 정사각형 부유구조물을 이용하여 동유체력과 구조응답의 상관관계를 파악하여 장방형 부유구조물의 안전성에 대한 영향을 검토하였다.
        4,000원
        145.
        2012.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 부유식 해상 풍력 발전기의 로터 축과 타워 상단에 작용하는 동적 하중을 계산하였다. 부유식 해상 풍력 발전기는 부유식 플랫폼, 타워, 낫셀, 허브, 그리고 3개의 블레이드로 구성되어 있는 다물체계 시스템이다. 본 연구에서는 이들 모두를 각각 6 자유도를 갖는 강체로 가정하였다. 부유식 해상 풍력 발전기의 타워는 플랫폼에 고정되어 있고, 3개의 블레이드는 허브에 고정되어 있다. 낫셀은 타워의 상부에 회전 관절로 연결되어 있으며, 블레이드와 허브로 구성된 로터는 낫셀과 회전 관절로 연결되어 있다. 본 연구에서 부유식 풍력 발전기의 운동 방정식은 다물체계 동역학을 기반으로 한 운 동방정식 구성 방법 중 하나인 recursive formulation을 이용하여 구성하였다. 외력으로는 부유식 플랫폼에 작용하는 비선 형 유체 정역학 힘과 선형 유체 동역학적 힘 그리고 계류력을 고려하였고, 블레이드에 작용하는 풍력을 고려하였다. 이와 같이 구성한 운동 방정식을 해를 구하여 풍력 발전기를 구성하고 있는 각 요소들의 각 연결 부위에 작용하고 있는 구속력 을 계산하였다. 그 결과, 동적 상태에서 풍력 발전기에 작용하는 하중은 정적 상태에서 풍력 발전기에 작용하는 하중보다 큰 것을 알 수 있으며, 따라서 부유식 풍력 발전기의 구조해석의 입력 값으로서 정적 하중보다 동적 하중을 고려하는 것이 더 엄격한 해석 기준이라고 할 수 있다.
        4,000원
        146.
        2012.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The transmission of the world Installed in an Office occurs through the air. Preventing that transmission, especially in indoor environments like those in airplanes, schools and offices, is a major public health concern. in this study the real situation of lab which is consist of dilution, Ultraviolet-C based air sterilization system. This model include indoor microbe transport which is generated human source. a computer simulation was performed to determine if such simulation can be used effectively to predict the more accurate, but difficult to perform, actual physical experiment. Result show that CFD can be modeled microbe transport effectively and it can be visualized microbe transport separation from flow streamline. also it make a good prediction of microbe transport.
        4,000원
        147.
        2012.04 구독 인증기관·개인회원 무료
        Recently, environmental problems associated with the excessive use of fossil fuel are hot issue throughout the world. As an alternative energy resource, the importance of renewable energy is continuously rising. Especially, growth rate of photovoltaic energy generation is the best. In this paper, we present the result of investigations pertaining to the development of photovoltaic energy generation system installed on the sea. The system is consisted of photovoltaic energy generation panel, panel supporting structure, and floating structure. In the panel supporting structure, fiber reinforced polymer plastic (FRP) member manufactured by the pultrusion process is used. A floating type PV power generation structures shall be fabricated and this unit structure (I.e., module) is connected to extend to the appropriate size considering safety, workability, and economic efficiency. Developed floating type photovoltaic energy generation system is installed at fish farm in the south coast of Korea.
        148.
        2012.04 구독 인증기관 무료, 개인회원 유료
        통항선박의 횟수가 잣은 연안의 항로주변은 선박에 의해 발생하는 항주파로 정온화가 필요한 항만시설이나 마리나에 많은 외력을 주게 된다. 이는 이동 및 정박 중인 선박이나 항만시설의 안정성을 저해시키는 요인으로 작용한다. 본 연구에서는 항만시설 및 마리나가 설치된 해역의 정온해역을 확보하고자 수치해석 및 수조시험을 통하여 고정형 부유식 구조물 설치에 따른 구조물로 인한 파고변화 및 주위의 유체역학적 특성을 파악하고자 하였다. 해상환경에 따른 소파효
        3,000원
        149.
        2012.04 구독 인증기관 무료, 개인회원 유료
        최근 해양레저에 대한 관심이 높아지면서 요트의 이용과 구매에 대한 관심이 증가됨에 따라 수상 또는 해상의 부유식 구조물이 필요하게 되었으며, 이에 따라 부유식 구조물을 계류하는 방식으로 수중 지반에 커다란 중량 콘크리트 블록을 설치하고 계류삭을 어느 정도 느슨하게 연결하여 계류하는 방식을 사용하고 있다. 하지만 수위차가 나거나 흐름이 있는 곳에서는 부유식구조물 자체가 위치제어가 안되므로, 한곳에 일정하게 머물게 하기 위해서 긴장계류장치(tens
        3,000원
        150.
        2012.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The objective of this study is to quantify the levels of airborne bacteria in pig building according to pig housing type. Mean concentration of airborne bacteria in the housing room of gestation/farrowing pigs were 3,690(±1,528)cfu m-3 in spring, 10,145(±4,266)cfu m-3 in summer, 1,546(±835)cfu m-3 in autumn, and 2,582(±916)cfu m-3 in winter, respectively. Mean concentrations of airborne bacteria in the housing room of nursery pigs were 11,628(±5,624)cfu m-3 in spring, 36,054(±13,260)cfu m-3 in summer, 2,743(±1,688)cfu m-3 in autumn, and 4,075(±2,300)cfu m-3 in winter, respectively. Mean concentrations of airborne bacteria in the housing room of growing/fattening pigs were 34,025(±8,652)cfu m-3 in spring, 36,619(±10,234)cfu m-3 in summer, 10,230(±3,521)cfu m-3 in autumn, and 26,208(±5,248)cfu m-3 in winter, respectively. As a result, mean concentrations of airborne bacteria in terms of pig housing type were highest in growing/fattening housing room followed by nursery housing room and gestation/farrowing housing room (p<0.05). The pig building showed the highest levels of airborne bacteria in summer followed by spring, winter and autumn (p>0.05). Overall airborne bacteria which have particle size over 2.1㎛ (stage 1~stage 4) accounted for approximately 80% compared to total airborne bacteria regardless of pig housing type. The predominant airborne bacteria in pig building were Micrococcus spp., Brevibacillus spp. and G(+) Bacillus.
        4,000원
        151.
        2011.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        To evaluate the indoor air quality of food manufacturing plants, the presence of viable bacteria and fungi was assessed in the indoor air of the facilities at which 9 food items were manufactured. Air samples were collected from the general zone, low clean zone and clean zone of each factory with an air sampler, in combination with plate counts agar using for bacteria, and dichloran-glycerol agar for fungi. The samples were incubated at 25℃for 4 to 7 days. After culture, the colony forming units (CFU) on each plate were counted and corrected with a positive hole conversion table. The average concentration of bacteria was 2.2 × 10³ CFU/㎥ in the general zone, 1.2 ×10³ CFU/㎥ in the low clean zone and 7.3 × 10² CFU/㎥ in the clean zone. The average concentration of fungal microbes was 2.5 × 10³ CFU/㎥ in the general zone, 2.6 × 10³ CFU/㎥ in the low clean zone, and 2.0 × 10² CFU/㎥in the clean zone. No meaningful differences were detected between the general zone and the low clean zone, but the clean zone had significantly lower concentrations than the other zones. Additionally, the identification of the fungi was performed according to morphological method using a giant culture and slide culture. The fungi were identified as belonging to 18 genera, and the genera Cladosporium(33%), Penicillium(29%) and Aspergillus(26%), predominated. Aspergillus isolates were identified to species level, and A. ochraceus, a mycotoxigenic species, was identified. As part of the effort to control the quality of the indoor air of food manufacturing plants, our results show that continued studies are clearly warranted.
        4,000원
        152.
        2011.11 구독 인증기관·개인회원 무료
        태풍 등 자연환경적인 요인과 통항선박 등에 의해 발생하는 항만에서의 파도는 정온화가 필요한 항만시설이나 마리나는 많은 외력에 노출되어 있다. 이는 이동 및 정박 중인 선박이나 항만시설의 안정성을 저해시키는 요인으로 작용한다. 본 연구에서는 수치해석을 통하여 항만 시설 및 마리나가 설치된 정온해역이 필요한 해역에 최적의 부유식 소파제의 유체역학적 특성을 파악하고자 하였다. 해상환경에 따른 소파효율 산출하고 부유식 소파제의 재원 변화 등에 따른 형상비에 대한 해를 제시하고자 한다.
        153.
        2011.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 착과 정도에 따른 ‘부유’ 감나무(Diospyros kaki cv. Fuyu)의 수체 부위별 질소화합물 분배와 저장양분의 축적 정도를 밝히고, 이들이 다음해 새로운 생장에 재이용되는 관계를 구명하였다. 6월 15일에 엽과비가 10, 20, 30이 되도록 착과량을 조절하였고, 일부는 모든 과실을 완전히 제거하였다. 6월 15일부터 11월 1일까지 증가한 총 아미노산은 제과수에서 가장 많았고, 엽과비가 높을수록 증가하였다. 뿌리는 엽과비 10에서 당년 아미노산의 증가가 없었다. 증가한 총 아미노산이 뿌리로 분배된 비율은 엽과 비 20에서 64%, 엽과비 30에서 18.5%, 제과수에서 81%였다. 과실로 분배된 비율은 엽과비 10에서 81%, 엽과비 20에서 12%, 엽과비 30에서 35%였다. 당년 착과량이 많은 엽과비 10의 잎에서 아미노산이 감소 하였다. 이 기간 동안 증가한 총 단백질은 엽과비가 높을수록 증가하였다. 당년에 증가한 단백질은 과실 로 가장 많이 분배하였고, 엽과비가 낮을수록 영구기관으로 분배되는 양이 감소하였다. 엽과비 30에서는 당년에 증가한 총 단백질이 과실로 59%, 뿌리로 40% 분배하였다. 당년 엽과비 10과 20의 잎에서 단백질 이 감소하였다. 이듬해 4월 10일부터 6월 10일까지 신초생장기 동안 아미노산은 모든 처리구의 2년생 이 상의 가지와 신초에서, 단백질은 모든 처리구의 신초에서 감소하였다. 특히 제과수는 뿌리에서 아미노산 이 540 mg, 단백질이 610 mg 감소하였다. 이듬해 새로운 부위의 총 아미노산과 단백질은 전년도 제과수 에서 각각 730 mg, 1290 mg으로 높았고, 전년도 착과량이 많은 엽과비 10에서 각각 120 mg, 400 mg 으로 낮았다.
        4,000원
        155.
        2011.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 낙동강 하구역의 사주지형 변화를 예측하기 위한 기초적 연구로서 하천유량의 변화에 따른 부유사의 물질수지에 대하여 검토하였다. 낙동강 하구역의 부유사 물질수지는 갈수기시 60,708 kg/day가 유입하고, 홍수기는 306,892 kg/day가 외해를 통하여 유출하는 것으로 산정되었다. 낙동강 하구역은 전반적으로 갈수기 및 평수기에 부유사의 유입, 홍수기에 부유사의 유출이 반복 되지만, 사주지형 주변에서는 부유사의 유입과 유출 거동이 복잡하게 나타나 장기 지형변동 모니터링이 필요한 것으로 나타났다.
        4,000원
        156.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구의 목적은 공기감염성 가축질병 유발의 주요 인자인 부유 세균 및 바이러스 등의 생물학상 인자들에 대한 유형별 공기청정기의 제균 효과를 비교 평가하는 데 있다. 시료 채취 장비에 대한 포집 성능 평가에서는 MS2 바이러스와 Pseudomonas fluorescens 모두 Button sampler보다는 Biosampler에 의한 채취 효율이 유의하게 높았다 (p<0.05). 공기청정기 유형 및 시료채취 방법에 관계없이 MS2 바이러스의 경우 초기 농도 대비 가동 후 5분에 50% 이상, 15분에 70% 이상, 30분에 80% 이상, 그리고 마지막 측정 시점인 60분에는 90% 이상의 제거 효율을 보이는 것으로 나타났다. P. fluorescens 세균의 경우 초기 농도 대비 가동 후 5분에 45% 이상, 15분에 50% 이상, 30분에 70% 이상, 그리고 마지막 측정 시점인 60분에는 75% 이상의 제거 효율을 보이는 것으로 나타났다. 유형별 공기청정기의 상대적 제균 효율을 비교해 보면 MS2 바이러스의 경우 이온 발생 방식>전기 집진 방식>습식 방식>건조 방식, P. fluorescens 세균의 경우 전기 집진 방식>이온 발생 방식>건조 방식>습식 방식의 순서로 조사되었다.
        4,000원
        157.
        2011.04 구독 인증기관·개인회원 무료
        In this paper, we present the result of investigations pertaining to the development of links between unit modules of the floating type photovoltaic energy generation system made of Pultruded FRP. Since the FRP has an excellent corrosion-resistance and high specific strength and stiffness, the FRP material may be highly appreciated for the development of the floating type photovoltaic energy generation system. we discussed the development concepts of the link between unit module of floating type photovoltaic energy generation system made of PFRP, tire, and synthetic fiber, briefly. The floating type photovoltaic energy generation system linked between unit modules is installed successfully at sea site.
        158.
        2011.03 KCI 등재후보 구독 인증기관 무료, 개인회원 유료
        The objective of this study is to assess a level of microbial contamination in the KTX. Investigation sites in the KTX were cabin, gateway, toilet and passenger seat. It was found that the mean concentrations of airborne bacteria and fungi were 157 CFU/m3 and 84 CFU/m3 , respectively, in all of the investigation sites of the KTX. They did not exceed the domestic standard (800 CFU/m3 ) for airborne bacteria and the guideline (150 CFU/m3 ) for airborne fungi recommended by WHO. Mean levels of bacteria and fungi distributed in passenger seat were 2.6×105 cfu/m3 and 3.7×104 cfu/m3 , respectively. The predominant genera identified in the KTX were Bacillus, Corynebacterium, Staphylococcus and Micrococcus for bacteria and Aspergillus, Cladosporium and Penicillium for fungi, respectively. Based on identification result, the profiles of airborne bacteria and fungi in the KTX was wholly similar to those of bacteria and fungi distributed in the passenger seat.
        4,000원
        159.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문는 펄트루젼 FRP 부재를 이용하여 부유식 태양광발전 시스템을 개발하기 위한 연구의 결과이다. 이미 설치 된 부유식 태양광발전 시스템의 단위구조물에 추가적인 단위구조물의 연결을 위하여 연결부를 설계하여 유한요소 해석을 통한 검증을 실시하였으며, 실제 현장에 기존 단위구조물과 연결부를 포함한 단위구조물의 연결부를 성공적 으로 시공하였다. 또한 기존 설치 구조물의 현장계측을 통하여 변위와 변형률을 얻어 기존의 실험 결과와 비교하여 구조물이 충분히 안전함을 확인하고 이를 바탕으로의 부유식 태양광발전 시스템의 설계 변경을 실시하였다. 설계변 경된 구조물에 대한 유한요소해석을 실시하였고 이를 허용응력과 비교하여 안전성을 검증하였다. 이로써 더욱 효율 적인 구조물을 개발하였으며 구조물의 제작하였다. 설계 변경된 단위구조물의 제작을 위한 펄트루젼 FRP부재의 생 산하였으며, 부유식 태양광 에너지 발전시설 구조물을 조립하였다.
        4,000원