검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 13,928

        4181.
        2011.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the effect of attentional focus and distance of external focus on the performance of balance task of upper extremity. Subjects (N=30) held a stick (2 m) and maintained it horizontally. All of the subjects performed balance task of upper extremity under four different attentional focus conditions: focus on hand (internal focus), marker at 10 cm inside of hand (external focus 1), marker at 10 cm outside of hand (external focus 2), marker at 20 cm outside of hand (external focus 3). The mean velocity of the bar (mm/s) and the muscle activity of biceps brachii (%RVC) were measured. They were decreased when the subjects focused on external focuses compared to internal focus and decreased as distance of attentional focus from body increased (p<.05). There were significant differences between groups (p<.05); internal focus-external focus 1, internal focus-external focus 2, internal focus-external focus 3, external focus 2-external focus 3. These results showed that external focus is more effective than internal focus in enhancing motor performance and focusing on more distant attentional focus results in enhanced motor performance promoting the utilization of more automatic control mechanisms.
        4,000원
        4182.
        2011.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study was to investigate the changes in the flexicurve kyphosis index (KI), the flexicurve lordosis index (LI) and the distance from the inferior angle of the scapula to the nearest vertebral spinous process (DS), as a dependent variable of scapular protraction, after applying of adolescents with thoracic hyperkyphosis using three different garments. A repeated measures design was used. Ten adolescents ( years) with thoracic hyperkyphosis ( Cobb angle) were recruited from a university hospital. A flexicurve ruler was used to measure KI and LI and a scoliometer was used to measure DS under three different conditions: wearing-a hospital garment (HG), wearing-a sham garment (SG), and wearing-an experimental garment (EG). KI under EG condition was significantly decreased compared with that wearing the HG. However, there was no significant difference between wearing the SG and HG. LI when wearing the EG was significantly increased compared with that when wearing HG. However, there was no significant difference under SG and HG conditions. DS when wearing the EG was significantly decreased compared with wearing HG. However, there was no significant difference between the SG and HG. The results of this study show that the EG was effective in decreasing KI, but not effective in decreasing LI. Hence, the effect of the EG for correcting sagittal spine angle in adolescents with thoracic hyperkyphosis is still debatable. However, since we showed that DS decreases in the EG, this method could be applied in correcting the scapular protraction.
        4,000원
        4183.
        2011.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The lumbrical muscles contribute to the intrinsic plus position, that is simultaneous metacarpophalangeal (MCP) flexion and interphalangeal (IP) extension. The strength of the lumbrical muscles is necessary for normal hand function. However, there is no objective and efficient method of strength measurement for the lumbrical muscles. In addition, previous studies have not investigated the measurement of the cross-sectional area (CSA) of the lumbrical muscles using ultrasonography (US) and the relationship between lumbrical muscle strength in the intrinsic plus position and the CSA. Therefore, the purpose of this study was to identify the measurement method of the CSA of the lumbrical muscles using US and to examine the relationship between maximal isometric strength and the CSA of lumbrical muscles. Nine healthy males participated in this study. Maximal isometric strength of the second, third, and fourth lumbrical muscles was assessed using a tensiometer in the intrinsic plus position which isolated MCP flexion and IP extension. The CSA of the lumbrical muscles was measured with an US. The US probe was applied on the palmar aspect of the metacarpal head with a transverse view of the hand in resting position. There was no significant difference between maximal isometric strength of the lumbrical muscles, but the fourth lumbrical muscle was stronger than the others. The CSA of the lumbrical muscles was significantly different and the fourth lumbrical muscle was significantly larger than the second lumbrical muscle. There was moderate to good correlation between maximal isometric strength and the CSA of the lumbrical muscles. Therefore, we conclude that maximal isometric strength of the lumbrical muscles was positively correlated to the CSA of the lumbrical muscle in each finger, while the measurement of the CSA of the lumbrical muscles, using US protocol in this study, was useful for measuring the CSA of the lumbrical muscles.
        4,000원
        4184.
        2011.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of this study was to investigate the effects of respiratory muscle training (RMT) with abdominal drawing-in maneuver (ADIM) on pulmonary function. Twenty-two subjects with restrictive breathing participated in this study. All the subjects were randomly assigned to three groups (7 subjects in RMT group, 7 subjects in RMT with ADIM group, 8 subjects in control group). The first group performed the RMT by using incentive respiratory spirometer (IRS). The second group performed the RMT by using IRS and the ADIM by using a Stabilizer. The exercises were conducted over four days. The pulmonary function was evaluated using the spirometer to measure the force exploratory volume in 1 second () and forced vital capacity (FVC). Measurements were conducted on the first day and the last day. A paired-t test was used for pre-post changes and the change rates in FVC and among each group were investigated by a one-way ANOVA. The findings of the the study were as follows: 1) There were significant differences of FVC and between pre and post in the two training groups (p<.05) 2) There was no significant difference of the change ratio the FVC and between the RMT group and RMT with ADIM group. Therefore, it is concluded that respiratory muscle and ADIM training, combined with two methods of treatment would suggest positive evidence for improving pulmonary function.
        4,000원
        4185.
        2011.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aims of this study were to investigate the correlation between the electromyographic (EMG) activity of the abductor hallucis (AbdH) and the amount of pressure measured by a pinch gauge (PG), and to compare the EMG activity of AbdH and the pressure measured by the PG during short foot (SF) exercise in subjects with pes planus and in subjects with a neutral foot alignment. Fourteen subjects were recruited for this study (pes planus group=7; neutral foot alignment group=7). A surface EMG was used to collect AbdH activity, and a PG was positioned under the first metatarsophalangeal joint to measure the pressure produced by the first metatarsal head during the SF exercise. The AbdH activity and the pressure measured by the PG showed a positive good correlation (r=.80, p<.05). The EMG activity of the AbdH and the pressure measured by the PG were significantly lower for subjects with pes planus than for subjects with a neutral foot alignment (p<.05). Based on these findings, the PG can be recommended as an effective instrument for evaluating the performance of the AbdH. It may also be beneficial for monitoring how well the SF exercise is performed, and for providing visual feedback to patients with pes planus during SF exercise in a clinical setting.
        4,000원
        4186.
        2011.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of this study was to analyze the relationship between physical impairments and daily activities on the basis of the outcome measurements in stroke patients. Seventy-six stroke patients participated in this study. Two physical therapists evaluated 3 clinical common measurements, i.e., the Fugl-Meyer Assessment (FMA), the Berg Balance Scale (BBS), and the Functional Independence Measure (FIM). Multiple regression analysis was used, as the dependent variables were the BBS and FIM; the independent variables were post-stroke duration, FMA of Upper Extremity (FMU), and FMA of Lower Extremity (FML). In the regression equation of the BBS, the coefficient of determination () was .383, and the FML was found to be the most important variable for determining the BBS score. In the regression equation of the FIM, was .531, and the FML was found to be the most important variable for determining the FIM. These results suggest that there is a need to determine the function of activities on the basis of the physical impairments of stroke patients. More variable measurement tools on the levels of body function and structure, as well as activity limitations are required.
        4,000원
        4187.
        2011.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study compared the stability of the cervical spine according to the presence of neck pain and deep neck flexor performance. Thirty subjects with neck pain, and thirty subjects without neck pain were recruited for this study. The Cranio-cervical flexion (CCF) test was applied using a pressure biofeedback unit to classify the subjects into four subgroups; no cervical pain and good deep neck flexor performance (NG group), no cervical pain and poor deep neck flexor performance (NP group), cervical pain and good deep neck flexor performance (PG group), and cervical pain and poor deep neck flexor performance (PP group). The head sway angle was measured using a three-dimensional motion analysis system. A 3-kg weight was used for external perturbation with the subject sitting in a chair in the resting and erect head positions with voluntary contraction of the deep neck flexors. A one-way analysis of variance (ANOVA) was performed with a Bonferroni post hoc test. The deep neck flexor performance differed significantly among the four groups (p<.05). The NG group had significantly greater deep neck flexor performance than NP and PP groups. The stability of the cervical spine also differed significantly among the four groups in the resting head position (p<.05). The head sway angle was significantly smaller in NG group as compared with the other groups. The PP group had the greatest head sway angle in the resting head position. However, there was no significant difference in the stability of the cervical spine among the groups in the erect head position with voluntary contraction of deep neck flexors (p=.57). The results of this study suggest that the deep neck flexor performance is important for maintaining the stability of cervical spine from external perturbation.
        4,000원
        4188.
        2011.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Highly textured Ag, Al and Al:Si back reflectors for flexible n-i-p silicon thin-film solar cells were prepared on 100-μm-thick stainless steel substrates by DC magnetron sputtering and the influence of their surface textures on the light-scattering properties were investigated. The surface texture of the metal back reflectors was influenced by the increased grain size and by the bimodal distribution that arose due to the abnormal grain growth at elevated deposition temperatures. This can be explained by the structure zone model (SZM). With an increase in the deposition temperatures from room temperature to 500˚C, the surface roughness of the Al:Si films increased from 11 nm to 95 nm, whereas that of the pure Ag films increased from 6 nm to 47 nm at the same deposition temperature. Although Al:Si back reflectors with larger surface feature dimensions than pure Ag can be fabricated at lower deposition temperatures due to the lower melting point and the Si impurity drag effect, they show poor total and diffuse reflectance, resulting from the low reflectivity and reflection loss on the textured surface. For a further improvement of the light-trapping efficiency in solar cells, a new type of back reflector consisting of Ag/Al:Si bilayer is suggested. The surface morphology and reflectance of this reflector are closely dependent on the Al:Si bottom layer and the Ag top layer. The relationship between the surface topography and the light-scattering properties of the bilayer back reflectors is also reported in this paper.
        4,000원
        4189.
        2011.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The preparation of Y2O3-doped ZrO2 nanoparticles in Igepal CO-520/cyclohexane reverse micelle solutions is studied here. In this work, we synthesized nanosized Y2O3-doped ZrO2 powders in a reverse micelle process using aqueous ammonia as the precipitant. In this way, a hydroxide precursor was obtained from nitrate solutions dispersed in the nanosized aqueous domains of a microemulsion consisting of cyclohexane as the oil phase, with poly (oxyethylene) nonylphenylether (Igepal CO-520) as the non-ionic surfactant. The synthesized and calcined powders were characterized by thermogravimetrydifferential thermal analysis (TGA-DTA), X-ray diffraction analysis (XRD) and transmission electron microscopy (TEM). The crystallite size was found to nearly identical with an increase in the water-to-surfactant (R) molar ratio. A FTIR analysis was carried to monitor the elimination of residual oil and surfactant phases from the microemulsion-derived precursor and the calcined powder. The average particle size and distribution of the synthesized Y2O3-doped ZrO2 were below 5 nm and narrow, respectively. The TG-DTA analysis showed that the phase of the Y2O3-doped ZrO2 nanoparticles changes from the monoclinic phase to the tetragonal phase at temperatures close to 530˚C. The phase of the synthesized Y2O3-doped ZrO2 when heated to 600˚C was tetragonal ZrO2.
        4,000원
        4190.
        2011.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        We report the structural characterization of BixZn1-xO thin films grown on c-plane sapphire substrates by plasma-assisted molecular beam epitaxy. By increasing the Bi flux during the growth process, BixZn1-xO thin films with various Bi contents (x = 0~13.17 atomic %) were prepared. X-ray diffraction (XRD) measurements revealed the formation of Bi-oxide phase in (Bi)ZnO after increasing the Bi content. However, it was impossible to determine whether the formed Bi-oxide phase was the monoclinic structure α-Bi2O3 or the tetragonal structure β-Bi2O3 by means of XRD θ-2θ measurements, as the observed diffraction peaks of the 2θ value at ~28 were very close to reflection of the (012) plane for the monoclinic structure α-Bi2O3 at 28.064 and the reflection of the (201) plane for the tetragonal structure β-Bi2O3 at 27.946. By means of transmission electron microscopy (TEM) using a diffraction pattern analysis and a high-resolution lattice image, it was finally determined as the monoclinic structure α-Bi2O3 phase. To investigate the distribution of the Bi and Bi-oxide phases in BiZnO films, elemental mapping using energy dispersive spectroscopy equipped with TEM was performed. Considering both the XRD and the elemental mapping results, it was concluded that hexagonal-structure wurtzite BixZn1-xO thin films were grown at a low Bi content (x = ~2.37 atomic %) without the formation of α-Bi2O3. However, the increased Bi content (x = 4.63~13.17 atomic %) resulted in the formation of the α-Bi2O3 phase in the wurtzite (Bi)ZnO matrix.
        4,000원
        4191.
        2011.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        We carried out this study to evaluate the grain refining in and the mechanical properties of alloys that undergo severe plastic deformation (SPD). Conventional rolling (CR) and cross-roll rolling (CRR) as SPD methods were used with Ni-20Cr alloy as the experimental material. The materials were cold rolled to a thickness reduction of 90% and subsequently annealed at 700˚C for 30 min to obtain a fully recrystallized microstructure. For the annealed materials after the cold rolling, electron back-scattered diffraction (EBSD) analysis was carried out to investigate the grain boundary characteristic distributions (GBCDs). The CRR process was more effective when used to develop the grain refinement relative to the CR process; as a result, the grain size was refined from 70μm in the initial material to 4.2μm (CR) and 2.4μm (CRR). These grain refinements have a direct effect on improving the mechanical properties; in this case, the microhardness, yield and tensile strength showed significant increases compared to the initial material. In particular, the CRR-processed material showed more effective values relative to the CR-processed materials. The different texture distributions in the CR (001//ND) and CRR (111//ND) were likely the cause of the increase in the mechanical properties. These findings suggest that CRR can result in materials with a smaller grain size, improved texture development and improved mechanical properties after recrystallization by a subsequent annealing process.
        4,000원
        4192.
        2011.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        A high-quality CIGS film with a selenization process needs to be developed for low-cost and large-scale production. In this study, we used Cu2In3, CuGa and Cu2Se sputter targets for the deposition of a precursor. The precursor deposited by sputtering was selenized in Se vapor. The precursor layer deposited by the co-sputtering of Cu2In3, CuGa and Cu2Se showed a uniform distribution of Cu, In, Ga, and Se throughout the layer with Cu, In, CuIn, CuGa and Cu2Se phases. After selenization at 550˚C for 30 min, the CIGS film showed a double-layer microstructure with a large-grained top layer and a small-grained bottom layer. In the AES depth profile, In was found to have accumulated near the surface while Cu had accumulated in the middle of the CIGS film. By adding a Cu-In-Ga interlayer between the co-sputtered precursor layer and the Mo film and adding a thin Cu2Se layer onto the co-sputtered precursor layer, large CIGS grains throughout the film were produced. However, the Cu accumulated in the middle of CIGS film in this case as well. By supplying In, Ga and Se to the CIGS film, a uniform distribution of Cu, In, Ga and Se was achieved in the middle of the CIGS film.
        4,000원
        4193.
        2011.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Nano-sized SnO2 thick films were prepared by a screen-printing method onto Al2O3 substrates. The sensing characteristics were investigated by measuring the electrical resistance of each sensor in a test box as a function of the detection gas. The nano-sized SnO2 thick film sensors were treated in a N2 atmosphere. The structural properties of the nano SnO2with a rutile structure according to XRD showed a (110) dominant SnO2 peak. The particle size of SnO2:Ni nano powders at Ni 8 wt% was about 45 nm, and the SnO2 particles were found to contain many pores according to the SEM analysis. The sensitivity of the nano SnO2-based sensors was measured for 5 ppm CH4 gas and CH3CH2CH3 gas at room temperature by comparing the resistance in air with that in the target gases. The results showed that the best sensitivity of SnO2:Ni and SnO2:Co sensors for CH4 gas and CH3CH2CH3 gas at room temperature was observed in SnO2:Ni sensors doped with 8 wt% Ni. The response time of the SnO2:Ni gas sensors was 10 seconds and recovery time was 15 seconds for the CH4 and CH3CH2CH3 gases.
        3,000원
        4194.
        2011.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Half-Heusler alloys are a potential thermoelectric material for use in high-temperature applications. In an attempt to produce half-Heusler thermoelectric materials with fine microstructures, TiCoSb was synthesized by the mechanical alloying of stoichiometric elemental powder compositions and then consolidated by vacuum hot pressing. The phase transformations during the mechanical alloying and hot consolidation process were investigated using XRD and SEM. A single-phase, half- Heusler allow was successfully produced by the mechanical alloying process, but a minor portion of the second phase of the CoSb formation was observed after the vacuum hot pressing. The thermoelectric properties as a function of the temperature were evaluated for the hot-pressed specimens. The Seebeck coefficients in the test range showed negative values, representing n-type conductivity, and the absolute value was found to be relatively low due to the existence of the second phase. It is shown that the electrical conductivity is relatively high and that the thermal conductivities are compatibly low in MA TiCoSb. The maximum ZT value was found to be relatively low in the test temperature range, possibly due to the lower Seebeck coefficient. The Hall mobility value appeared to be quite low, leading to the lower value of Seebeck coefficient. Thus, it is likely that the single phase produced by mechanical alloying process will show much higher ZT values after an excess Ti addition. It is also believed that further property enhancement can be obtained if appropriate dopants are selectively introduced into this MA TiCoSb System.
        3,000원
        4195.
        2011.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        The Xe plasma flat lamp, considered to be a new eco-friendly LCD backlight, requires a further improvement of its luminance and luminous efficiency. To improve the performance of this type of lamp, it is necessary to understand the effects of the discharge variables on the luminous characteristics of the lamp. In this study, the luminous characteristics of a coplanartype Xe plasma flat lamp with a teeth-type electrode pattern were analyzed while varying the gas composition, gas pressure and input voltage. The effects of the phosphor layer on the discharge and the luminous characteristics of the lamp were also studied. The luminous efficiency of the coplanar-type Xe plasma flat lamp improved as the Xe input ratio and gas pressure increased. Higher luminous efficiency was also obtained when helium (He) was used as a buffer gas and when a phosphor layer was fabricated on the electrode region. In contrast, the luminous efficiency was reduced with increasing the input voltage. It was found that the infrared emissions from the lamp were affected by the Xe excitation rate in the plasma, the Xe gas density, the collisional quenching of excited Xe species by gas molecules, and the recombination rate between the Xe ions and electrons.
        4,000원
        4196.
        2011.10 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        Two dimensional (2D) arrays of noble metal nanoparticles are widely used in the sensing of nanoscale biological and chemical events. Research in this area has sparked considerable interest in many fields owing to the novel optical properties, e.g., the localized surface plasmon resonance, of these metallic nanoarrays. In this paper, we report successes in fabricating 2D arrays of gold nano-islands using nanosphere lithography. The reproducibility and the effectiveness of the nano-patterning method are tested by means of spin coating and capillary force deposition. We found that the capillary force deposition method was more effective for nanospheres with diameters greater than 600 nm, whereas the spin coating method works better for nanospheres with diameters less than 600 nm. The optimal deposition parameters for both methods were reported, showing about 80% reproducibility. In addition, we characterize gold nano-island arrays both geometrically with AFM as well as optically with UV-VIS spectrometry. The AFM images revealed that the obtained nano-arrays formed a hexagonal pattern of truncated tetrahedron nano-islands. The experimental and theoretical values of the geometric parameters were compared. The 2D gold nano-arrays showed strong LSPR in the absorption spectra. As the nano-islands increased in size, the LSPR absorption bands became red-shifted. Linear dependence of the plasmon absorption maximum on the size of the gold nano-islands was identified through the increment in the plasmon absorption maximum rate for a one nanometer increase in the characteristic length of the nano-islands. We found that the 2D gold nano-arrays showed nearly seven-fold higher sensitivity of the absorption spectrum to the size of the nano-islands as compared to colloidal gold nano-particles.
        4,000원
        4197.
        2011.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to see the effect of functional electrical stimulation on forced vital capacity and alternating motion rate in children with spastic cerebral palsy. This study divided 20 children with spastic cerebral palsy into two groups; functional electrical stimulation treatment group and control group. Functional electrical stimulation treatment group had 20min per day treatment three times a week for four weeks and the control group did not have any treatment. Before and after intervention, this study measured forced vital capacity and alternate motion rate(/peo/,/teo/) for all children. Forced vital capacity showed statistically significant increase for the group with functional electrical stimulation(p<.05) while the control group did not show any significant increase(p>.05). Alternate motion rate showed statistically significant increase for the group with functional electrical stimulation(p<.05) while the control group did not show any significant increase(p>.05). This result shows that functional electrical stimulation affected the ability of the children with spastic cerebral palsy who have decreased breathing and phonation capability.
        4,000원
        4198.
        2011.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to examine the effect of stabilization, resistance exercise, and combined exercise for lumbar on balance and walking ability of elderly. This study selected 22 subjects of over 65 years old elderly women who satisfy the study condition from A, B and C Senior Citizen's Center, in Daegu. The subjects were divided into groups; 7 for resistance exercise group, 8 for stabilization exercise group, and 7 for combined exercise group(resistance and stabilization exercise). The exercises were conducted for 60min a day, three times a week for 12 weeks. Balance and walking ability were checked before the exercise, 6 weeks later, and 12 weeks later. First, all lumbar muscle strengthening exercises were effective for static balance which changed according to exercising period. In dynamic balance, the resistance exercise group showed significant improvement in sit to stand. Stabilization exercise group showed significant improvement in all factors. The combined exercise group showed significant improvement in sit to stand and timed up and go. There was no difference between the exercise types. Second, the resistance exercise group showed significant change in Cadence which changed according to exercising period. The combined exercise group showed significant improvement in all factors. Between the exercise types, combined exercise was a bit more effective than resistance exercise. According to the result of 12 weeks of lumbar muscle exercise, combined exercise is considered to be the most effective exercise to prevent fall as it helps balance and walking ability slightly more than other exercises. Therefore, this study can understand the risk factors for fall accidents that frequently occur among elderly and adopt the combined exercise to prevent fall which in turn will prevent secondary problems occur from fall accidents and improve quality of life of elderly.
        4,000원
        4199.
        2011.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to measure the effect of change in heel height on lower extremities activity of young women on high-heeled shoes that young women prefer from more kinetic and realistic perspective as this study changes the degree of slope on a treadmill. The study subjects are 15 young and healthy women who do not have any external injuries or problem with walking and understand the purpose of this study clearly. They wore three different height of heels(1cm, 7cm, 12cm) and walked on a treadmill at a constant speed of 3km/h. EMG value of four muscles (anterior tibial muscle, gastrocnemius muscle, straight muscle of thigh, and biceps muscle of thigh) were collected when walking and the change according to the height of heels were analyzed using one-way ANOVA. Multiple comparison analysis on anterior tibial muscle and heel height showed that the group with 12cm heel showed significantly high muscle activation compared to the groups with 1cm and 7cm heels. The result of this study can be used for various perspectives from inferring and mediating problems caused by wearing high heels on different ground slopes for a long time
        4,000원
        4200.
        2011.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study identify that spinal decompression therapy effect on and pain, length Of leg distance(LLD), and muscle power and flexibility in patient with low back pain. The participants is 20 female and male with low back pain, and participant assign to decompression therapy group and control group at random. The decompression therapy apply to 20 minute 3 time for a week during 4 weeks. The Measurement items is pain, LLD, and muscle power, flexibility. The comparison between the before and after was Wilcoxon's U test, and 2 group after spinal decompression therapy application compared Mann-Whithney U test. Spinal decompression therapy reduced statistically significance the pain, LLD, and increased statistically significance the muscle power and flexibility increased the muscle power(p<.05). This study showed that spinal decompression therapy does affect pain, LLD, and muscle power and flexibility in patient with low back pain.
        4,000원