        검색결과 8

        2.
        2023.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        ATP luminescence measurements (using Relative Light Units, RLU) has been used to assess the levels of bacterial contamination on the surfaces of various materials. However, not much is known about their suitability in assessing bacterial contamination on paper surfaces. This study was conducted to evaluate the feasibility of using ATP luminometers in measuring levels of bacteria contamination on paper surfaces. The three ATP luminometers studied were Clean-Q, smart PD-30, and 3M™ Clean-Trace™ LM1 manufactured by different companies. There were some differences in RLU results among the three ATP luminometers when they were tested with different concentrations of Micrococcus luteus cell suspension. 106 - 107 cells were required in order to effectively detect Bacillus subtilis, Escherichia coli, and Micrococcus luteus on the surfaces of A4 printing sheets (100 cm2) when using the three ATP luminometers. The sizes and physical properties of surface areas varied slightly among the swabs used for the three ATP luminometers. Concentration-specific measurements (RLU) of M. luteus taken from the surfaces of six kinds of paper (fine print paper, medium print paper, ground paper, newsprint paper, practice paper, tracing paper) were possible using the smart PD-30 and LM1 ATP luminometers. ATP detection values of M. luteus varied among the six types of paper. The highest ATP detection values were found on the surfaces of tracing paper. If the RLU value is recorded at the level of 1000, this could indicate a very high bacterial contamination level of 105 to 106 CFU/4 cm2.
        4,000원
        3.
        2023.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Some plant pathogenic bacteria species are environmentally high-risk organisms that have a negative impact on agricultural production. Experiments with these pathogens in a biosafety laboratory require safety protocols to prevent contamination from these pathogens. In this work, we investigated the efficacy of using UV-C irradiation for the purpose of sterilizing an important plant pathogenic bacterium, Erwinia pyrifoliae, in a laboratory setting. For the test, the pathogen (1.71 × 108 CFU/ml) was inoculated on the surface of Potato Dextrose Agar (PDA) and the inoculated media were placed on a work surface in a biosafety cabinet (Class 2 Type A1) as well as on three different surfaces located within the laboratory: a laboratory bench, a laboratory bench shelf, and the floor. All the surfaces where the media were placed were in range of the UV-C beam projected by the UV lamp installed in the ceiling of the BSL 2 Class biosafety laboratory. Measurements of the reduction rate of bacteria under UV-C irradiation were conducted at different time intervals: after 10 minutes, 30 minutes, 1 hour, 2 hours, and 3 hours, respectively. The reduction rate of bacteria ranged from 90% to 99% after 10min irradiation, from 97.8% to 100% after 30 minutes of irradiation, from 99.1% to 100% after 1 hour of irradiation, and from 99.99% to 100% after 2 hours of irradiation. After 3 hours of irradiation, the pathogen was completely killed in all the test conditions. In the cases of the laboratory bench and the shelf of the laboratory bench, the effectiveness of UV-C irradiation differed slightly between the site where the bacteria located vertically under the lamp and the site where the bacteria were located 1 meter away horizontally from the site under of the lamp.
        4,000원
        4.
        2023.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        High-risk microbial pathogens are handled in a biosafety laboratory. After experiments, the pathogens may remain as contaminants. To safely manage a biosafety laboratory, disinfection of microbial contaminants is necessary. This study was carried out to evaluate the effect of UV-C irradiation for the disinfection of a high-risk plant pathogenic bacterium Erwinia amylovora in a laboratory setting. For the test, the bacterium (8.7 × 106 CFU/ml) was embedded on the surface of PDA and placed on the work surface in a biosafety cabinet (Class 2 Type A1), and on the three different surfaces of the laboratory bench, laboratory bench shelf, and the floor which were positioned in a straight line from the UV lamp installed in the ceiling of the biosafety laboratory (BSL 2 class). UV-C irradiation was administered for 10min, 30min, 1 hr, 2hr, 3 hr, and 4hr, respectively. The reduction rate of bacteria ranged from 95% to 99% in regard to 10 min irradiation, from 97% to 99% in regard to 30 min irradiation, from 99.8% to 99.9% in regard to 1 hr irradiation, and higher than 99.99% in regard to 2 hr irradiation. The bacterium was completely inactivated after 3 hr irradiation. A similar UV-C irradiation effect was obtained when the bacterium was placed at a distance of 1 m from the three different surface points. Bacterial reduction by UV-C irradiation was not significantly different among the three different surface points.
        4,000원
        5.
        2022.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study was conducted to obtain basic information for the use of the ATP fluorescence detection method in consideration of the most common and frequent contamination situation that occurs in laboratories dealing with fire blight causing bacterium, Erwinia amylovora. ATP luminescence measurements (Relative Light Unit, RLU) were tested against these pathogen cells (CFU/cm2) which were artificially introduced on the disinfected surface of a bench floor of a biosafety cabinet (Class 2 Type A1), on a part of the disinfected surface of a lab experimental bench, on a part of the disinfected floor, and on a part of the disinfected floor of an acryl chamber for bioaerosol studies in a biosafety laboratory (BSL 2 class) using two different ATP bioluminometers. RLU values were not much increased with the bacterial cells from 2.15 × 102/cm2 to 2.15 × 106/cm2. RLU values varied among the four different surfaces tested. RLU values measured from the same number of bacterial cells differed little between the two different ATP bioluminometers used for this study. RLU values obtained from bacterial cells higher than 2.15 × 107/cm2 indicated the presence of bacterial contamination on the four different surfaces tested. The R2 values obtained based on the correlation data for the RLU values in response to different E. amylovora cell numbers (CFU/ cm2) on the surfaces of the four test spots ranged from 0.9827 to 0.9999.
        4,300원
        6.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Airborne bacteria are expected to float in the mushroom cultivation house, as it is a special environment with high humidity and high temperatures. Their concentration and diversity in the indoor air of the cultivation house could effect the health of farmers and the quality of mushrooms. To examine whether microbiota of airborne bacteria change from year to year, we measured the indoor temperature, humidity, and airborne bacterial concentration from mushroom cultivation houses located in six regions in Korea from 2020 to 2021, and isolated and identified airborne bacteria. The surveyed data were compared and the bacterial diversity of the 1st year and the 2nd year were determined. Based on the average temperature and humidity data surveyed, it can be seen that the temperature and humidity environment in the cultivation houses is such that bacteria can easily reproduce. It was observed that the temperature inside the cultivation houses tends to be higher or lower depending on the season and correlates with the temperature outside the cultivation houses. In the first year survey, 32 species of 20 genera were identified, and in the second year survey, bacteria belonging to 29 species of 22 genera were identified. Among them, the most detected species were all species belonging to the genus Bacillus. There were only three species (Bacillus altitudinis, Brevibacterium frigoritolerans, and Staphylococcus epidermidis) that were continuously isolated in common. Our results showed that the species of floating bacteria greatly vary from year to year even for the same cultivation houses.
        4,000원