검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 28,363

        1.
        2024.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Piloti-type structures with vertical irregularity are vulnerable to earthquakes due to the soft structure of the first story. Structural characteristics of buildings can significantly affect the seismic loss function, calculated based on seismic fragility, and therefore need to be considered. This study investigated the effects of the number of stories and core locations on the seismic loss function of piloti-type buildings in Korea. Twelve analytical models were developed considering two variations: three stories (4-story, 5-story, and 6-story) and four core locations (center core, x-eccentric core, y-eccentric core, and xy-eccentric core). The interstory drift ratio and peak floor acceleration were assessed through incremental dynamic analysis using 44 earthquake records, and seismic fragility was derived. Seismic loss functions were calculated and compared using the derived seismic fragility and repair cost ratio of each component. The results indicate that the seismic loss function increases with more stories and when the core is eccentrically located in the piloti-type structure model. Therefore, the uncertainty due to the number of stories and core location should be considered when deriving the seismic loss function of piloti-type structures.
        4,000원
        2.
        2024.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Earthquakes of magnitude 3.0 or greater occur in Korea about 10 times on average yearly, and the number of earthquakes occurring in Korea is increasing. As many earthquakes have recently occurred, interest in the safety of nuclear power plants has increased. Nuclear power plants are equipped with many cabinet-type control facilities to regulate safety facilities, and function maintenance is required during an earthquake. The seismic performance of the cabinet is divided into structural and functional performances. Structural performance can be secured during the design procedure. Functional performance depends on the vibration performance of the component. Therefore, it is necessary to confirm the seismic performance of the components. Generally, seismic performance is confirmed through seismic simulation tests. When checking seismic performance through seismic simulation tests, it is difficult to determine the effect of frequency and maximum acceleration on an element. In this paper, shaking table tests were performed using various frequencies and various maximum accelerations. The seismic performance characteristics of the functions of electrical equipment components were confirmed through tests.
        4,000원
        3.
        2024.05 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the SBC system, a new mechanical joint method, was developed to improve the constructability of precast concrete (PC) beam-column connections. The reliability of the finite element analysis model was verified through the comparison of experimental results and FEM analysis results. Recently, the intermediate moment frame, a seismic force resistance system, has served as a ramen structure that resists seismic force through beams and columns and has few load-bearing walls, so it is increasingly being applied to PC warehouses and PC factories with high loads and long spans. However, looking at the existing PC beam-column anchorage details, the wire, strand, and lower main bar are overlapped with the anchorage rebar at the end, so they do not satisfy the joint and anchorage requirements for reinforcing bars (KDS 41 17 00 9.3). Therefore, a mechanical joint method (SBC) was developed to meet the relevant standards and improve constructability. Tensile and bending experiments were conducted to examine structural performance, and a finite element analysis model was created. The load-displacement curve and failure pattern confirmed that both the experimental and analysis results were similar, and it was verified that a reliable finite element analysis model was built. In addition, bending tests showed that the larger the thickness of the bolt joint surface of the SBC, the better its structural performance. It was also determined that the system could improve energy dissipation ability and ductility through buckling and yielding occurring in the SBC.
        4,200원
        4.
        2024.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : This study defines private and public service providers connected to a public data hub in a smart city and examines the information that should be exchanged between them. The information exchange scheme covers data exchange at a minimum level. METHODS : First, we reviewed the entities participating in the emergency charging service and designed the scope of information linkages between the entities. Second, we diagnosed the main information linkages according to a service flowchart. Third, we reviewed the basic information requirements linked to actors participating in the service. Finally, we derived and presented information linked to the subjects. RESULTS : In addition to the basic requirements, the number of data-exchange information sets specified was four, which was the scope of the aforementioned study. We defined and analyzed an efficient information exchange system between various actors involved in emergency charging services. Data were defined based on interactions between service users, operators, providers, and data hubs. Each set had a different scope and purpose. CONCLUSIONS : Information collected and provided by emergency charging service providers in connection with a data hub that manages urban energy was proposed.
        4,000원
        5.
        2024.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : This study sought ways to connect urban above ground roads and underground roads to utilize urban space more efficiently in the development of underground roads, which are currently under development in order to alleviate problems caused by oversaturated above-ground roads. A simulation analysis was performed to develop an operation strategy that connects above-ground and underground roads to prevent congestion in above-ground areas such as entrances and exits from transferring to underground roads as well as to present its effectiveness. METHODS : Traffic efficiency analysis according to the operation strategy of above ground and underground roads was conducted using VISSIM, a microscopic traffic simulation software. The functions implemented in VISSIM were collected to set effectiveness analysis indicators for each underground road operation strategy. The Shinwol-Yeoui Underground Road was selected as the spatial scope of this study, and a surrounding road network was constructed. In addition, full-scale simulation analysis preparations were completed by performing network calibration based on the actual traffic attribute data of underground and surrounding surface roads within the construction scope. Accordingly, a traffic efficiency evaluation analysis was conducted based on the underground road operation strategy. CONCLUSIONS : Information on the increase in traffic volume within the Shinwol-Yeoui underpass was collected every 15 min. The analysis was divided into an analysis of the traffic situation within the underpass through demand control when the service level reached level D and an analysis of when demand control was not performed. It was found that demand control was necessary for the Shinwol-Yeoui Underpass when the internal traffic volume reached 2,500 vehicles/h. In addition, to analyze the spread of traffic and congestion owing to the weaving phenomenon caused by lane changes in the underpass, an analysis was conducted to observe the traffic improvement effect when full lane changes are possible for the Shinwol-Yeoui Underground Road, which currently has some lane-change-permitted sections. The analysis showed that both the maximum traffic volume and average travel speed showed better results when lane changes were allowed, and the communication situation at Yeoui JCT was found optimal.
        5,100원
        6.
        2024.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : The effect of yellow carpet visibility enhancement was verified and its impact on traffic safety for effective introduction of traffic safety facilities was studied. METHODS : There is currently no scientific evidence demonstrating that yellow carpets improve pedestrian awareness. In this study, the effect of increasing visibility caused by the installation of yellow carpet was verified, and the effect of improving the level of traffic safety was examined through an objective analysis. A drone was used to collect and analyze video data to compare the driving speeds of vehicles passing near yellow carpets at six different sites and diagnose the effects of speed reduction. RESULTS : The results showed that the visibility improvement values before and after the installation of the yellow carpet differed from place to place, but a visibility improvement effect existed in certain cases. In terms of the adequacy of the installation site, the yellow carpet had no deceleration effect on vehicles driving on signalized local streets and collector highways. It was found that there was a speed reduction effect on unsignalized local streets. CONCLUSIONS : To enhance traffic safety promotion, yellow carpets should be placed on unsignalized local streets. It is important to place the yellow carpet in the right place in a proper manner.
        4,000원
        7.
        2024.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        인공지능으로 대표되는 급격한 사회 변화는 학교 교육의 개선을 요구하고 있고, 일부 지역에서는 국제 교육과정인 IB를 공교육에 도입하여 운영하고 있다. 본 연구는 미래형 교육을 준비하기 위하여 IB PYP에 서 시사점을 얻고자 하였으며, 이를 위하여 IB PYP에 관한 문헌 연구와 관계자 심층 면담을 실시하였다. 문헌 연구를 통해 총론적, 각론적 수준에서 2022 개정 교육과정과의 비교·분석하였고, 심층 면담을 통해 개념기반 탐구학습, 공유와 협력의 문화 등의 특징을 추출하였다. 연구를 통해 학교 교육 개선 방안으로 교사 수준 교육과정, 개념기반 탐구학습의 확산, 학년별 특성에 맞는 중점 교수·학습 방법을 적용할 것을 제안하였다.
        6,600원
        8.
        2024.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : We propose a framework to evaluate the reliability of integrating homogeneous or heterogeneous mobility data to produce the various data required for greenhouse gas emission estimation. METHODS : The mobility data used in the framework were collected at a fixed time from a specific point and were based on raster data. In general, the traffic volume for all traffic measurement points over 24 h can be considered raster data. In the future, the proposed framework can be applied to specific road points or road sections, depending on the presence or absence of raster data. RESULTS : The activity data required to calculate greenhouse gas emissions were derived from the mobility data analysis. With recent developments in information, communication, and artificial intelligence technologies, mobility data collected from different sources with the same collection purpose can be integrated to increase the reliability and accuracy of previously unknown or inaccurate information. CONCLUSIONS : This study will help assess the reliability of mobility data fusion as it is collected on the road, and will ultimately lead to more accurate estimates of greenhouse gas emissions.
        4,000원
        9.
        2024.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        PURPOSES : Snow-removal performance is performed in this study to assess the feasibility of replacing calcium-chloride solution with sodium chloride solution at the minimum temperature of -5 ℃ during snowfall. METHODS : The atmospheric temperature distribution in Seoul was analyzed. The manufacturing, storage, and indoor melting performance of calcium-chloride and sodium-chloride solutions were evaluated, and on-site snow-removal performance was evaluated based on the solution type. RESULTS : According to the results of the melting performance test at -5°C, the melting capacity of the sodium chloride solution was expressed at a level exceeding 90% of that of the calcium chloride solution, indicating a similar melting performance between the two solutions. Additionally, based on the snow removal performance test using aqueous solutions, the snow removal performance of the sodium chloride solution was found to be approximately 96% compared to that of the calcium chloride solution, indicating minimal differences in snow removal performance due to changes in the type of solution. CONCLUSIONS : Similar snow-removal performance was achieved when the sodium chloride solution was used instead of calciumchloride aqueous solution at temperatures exceeding -5 ℃.
        4,000원
        14.
        2024.04 구독 인증기관·개인회원 무료
        기존 교량을 일체식 교대 교량과 같이 거동할 수 있도록 교대 흉벽과 상부슬래브를 일체화하는 흉 벽 일체식 교대 교량 공법에 관한 것으로, 교대 흉벽은 뒤채움 토사의 토압을 주요 하중으로 설계되기 때문에 배면부에는 휨보강 철근이 배치되지만 흉벽 일체화에 따른 흉벽 전면부에 온도팽창에 저항하 기에 부족한 철근량을 가지게 된다. 본 실험 연구는 일체화된 흉벽 구조체의 단차부 전면에 부착-정 착방식으로 제작된 FRP 보강체를 사용하여 휨 실험을 수행하고 이를 비교 분석하였다.
        15.
        2024.04 구독 인증기관·개인회원 무료
        최근 프리팹 부재간 비간섭 계면이음 설계기술이 도입되고 기계주입식 충진 기술의 실용화 성공으 로, 교량 프리캐스트 바닥판 시공의 저해요인이 상당히 해결될 수 있다. 이 때 프리팹 부재에 GFRP 보강근을 적용한다면 가공조립비 절감 효과가 있고, 프리팹 부재의 경량화로 경제성이 제고될 뿐 만 아니라, 현장 안전성과 작업편의성이 향상될 것으로 보인다. 기존 철근 연신율은 20% 내외 수준인데 반해 GFRP 보강근의 파괴변형율은 3% 내외이며 탄성계수는 50GPa (강재 대비 25%수준)이므로, 이 러한 재료특성 차이로 인한 휨성능에 대한 영향 평가가 필요하다. 특히 GFRP 보강근을 프리캐스트 바닥판과 거더 간 계면이음 적용에 따른 영향을 평가하기 위한 프로토타입 거더를 설계하고, 재료간 계면의 부착 특성을 고려한 유한요소해석 모델을 수립하고 극한 휨성능과 소요 계면 전단성능과의 상 관관계를 검토하였다. 추후 본 변수해석 연구에 대해 실험적 검증이 완수된다면, GFRP 보강근 설계기 술을 정립하는 데 기여할 것으로 기대된다.
        16.
        2024.04 구독 인증기관·개인회원 무료
        콘크리트는 우수하고 뛰어난 내구성에 의해 구조물 건설에 가장 많이 사용되는 재료 중 하나이다. 오늘날 급격한 경제의 발전 및 도시화 등에 의해 오늘날 구조물은 대형화 및 고층화되고 있다. 이에 따라 고강도, 고경량, 고내구 콘크리트 개발에 대한 다양한 연구가 진행되고 있다. 특히 나노소재가 첨 가된 콘크리트는 나노소재에 의해 미세공극이 충진되어 강도 및 내구성이 우수한 것으로 알려져있다. 그러나 기존 나노소재가 적용된 콘크리트는 단위중량이 높아 이를 구조물에 적용시 자중을 증가시키 는 단점이 있다. 이에 본 연구에서는 입자 직경이 10-100 μm이지만 입자 내부의 공극이 있어 단위 중량이 0.6t/m3인 Micro hollow sphere가 잔골재로 사용된 고경량, 고강도 콘크리트의 염화물 침투 특성을 평가하였다. 본 연구에서 사용된 실험변수로써 Micro hollow sphere의 잔골재 치환량(0%, 42%, 100%)가 고려되었으며, 이 시편의 단위중량은 각각 2.37 t/m3, 1.89 t/m3, 1.62 t/m3이다. Micro hollow sphere가 사용된 콘크리트의 염화물 침투 특성은 NT-Build 492 시험을 통해 평가되었다. 실 험결과 Micro hollow sphere 치환율이 0%, 42%, 100%인 실험체의 단위중량은 염화이온 확산계수는 각각 4.45 x10-13 m2/s, 2.57 x10-13 m2/s, 1.4x10-13 m2/s로 Micro hollow sphere 치환량이 증 가함에 따라 염화이온 침투 저항성이 증가하는 것으로 확인되었다. 따라서, Micro hollow sphere를 이용한다면 단위중량이 작으며 내구성이 큰 고경량, 고내구 콘크리트 배합이 가능할 것으로 판단된다.
        17.
        2024.04 구독 인증기관·개인회원 무료
        산업혁명 이후 화석연료 사용의 급격한 증가와 온실가스 배출이 심해져 온난화 경향이 심각해 탄소 배출을 절감하는 상황이 요구되고 있다. 본 연구는 탄소 격리 효과를 가지고 있는 바이오차와 콘크리 트의 취성을 극복하고 연성을 증가시켜 균열의 발생을 최소화하여 내구성을 향상 시킬 수 있는 PVA (Polyvinyl Acohol)섬유를 활용하여 기존의 콘크리트의 단점을 보완하고, 시멘트 저감 효과와 친환경 성을 갖춘 고연성 섬유보강 시멘트 복합체(ECC)를 제작하여 바이오차 시멘트 대체 비율에 따른 ECC 의 역학적 특성을 분석하고 비교하였다. 바이오차 시멘트 대체 비율 5%를 최대치로 설정하여 시멘트 대체 비율을 1%씩 올려 0%, 1%, 2%, 3%, 4%, 5%까지 설정하여 플로우 시험, 압축강도 실험, 쪼갬 인장 강도 실험, 휨 강도 실험을 진행하였다. 모르타르의 유동성을 평가하기 위해 플로우 시험을 실시 했으나, 바이오차 시멘트 대체 비율에 관계없이 플로우는 큰 차이를 보이지 않았다. 바이오차 시멘트 대체 비율에 따른 강도 비교를 위한 압축강도 실험, 쪼갬 인장 실험에서는 바이오차 시멘트 대체 비율 2%가 가장 높은 값을 보였다. 휨 강도 실험에서는 바이오차 시멘트 대체 비율 3%가 가장 큰 값을 보 였다. 휨 강도 실험에서는 바이오차를 혼입하지 않은 노말 ECC와 비교했을 때 바이오차의 시멘트 대 체율이 높아질수록 강도가 감소하였지만, 압축강도와 쪼갬 인장강도 실험에서는 대체율이 높아지면 강 도가 증가하는 경향이 나타났다.
        18.
        2024.04 구독 인증기관·개인회원 무료
        본 연구에서는 바이오차 콘크리트의 개발과 역학적 특성에 대한 연구를 통해, 환경친화적이고 지속 가능한 건설 자재로의 활용 가능성을 탐구하였다. 바이오차는 바이오매스와 숯의 합성어로, 탄소격리 효과가 있어 시멘트 대체재로 사용할 수 있는지 실험을 통해 분석하였다. 바이오차를 시멘트 질량비 5%를 치환 최대치로 설정하였다. 실험 변수로 바이오차의 시멘트 대체율을 0%에서 5%까지 1%씩 올 려 대체하여 방식으로 설정하였다. KS F 2403에 따라 시편을 제작하였고, 슬럼프, 압축강도, 쪼갬인장 강도, 휨강도를 실험을 통해 바이오차 콘크리트의 역학적 특성을 분석·비교하였다. 실험 결과, 바이오 차의 대체율이 증가할수록 슬럼프가 감소하는 경향이 나타났다. 압축강도는 바이오차가 시멘트를 대체 함으로써 강도가 감소하였지만, 대체율 1%(23.37MPa)를 제외한 실험체에서 설계기준 압축강도 24MPa 이상을 만족하였다. 휨강도는 대체율 5%가 가장 높았으며 0% 대비 약 12% 증가하였다.
        19.
        2024.04 구독 인증기관·개인회원 무료
        본 논문은 초탄성 형상기억합금의 복원성능에 의해 지속적으로 사용이 가능하고 마찰볼트 적용으로 에너지 소산 능력이 우수한 에너지 소산형 댐퍼를 제안하고 성능의 우수성을 입증하기 위해 구조용 탄소강이 적용된 댐퍼와 함께 해석을 통한 결과 비교 분석을 진행하였다. 해석결과에 대해 최대하중, 잔류변위, 에너지 소산등의 분석을 진행하여 초탄성 형상기억합금이 적용된 댐퍼의 우수성을 입증하였 으며, 해석 결과로 초탄성 형상기억합금이 적용됨에 따라 하중 성능과 잔류변위의 회복성능이 상당히 개선됨을 확인하였다. 최대하중의 경우 SSF댐퍼가 382.60kN으로 가장 우수하였으며 잔류변위의 경우 마찰볼트가 적용되지 않은 SS10, SS15가 0mm로 가장 우수한 회복거동을 보였다. 에너지소산의 경우 마찰볼트와 재료의 항복에 의한 연성효과가 우수한 CSF15가 가장 우수한 성능에 대한 거동 특성을 파악한다.
        20.
        2024.04 구독 인증기관·개인회원 무료
        Regulatory Guide (RG) 1.60 presents the response spectra for the seismic design, especially for the safe shutdown earthquake (SSE), of nuclear power plants. This guide is applicable to a two-step process involving the issuance of construction permits and operating licenses (10 CFR Part 50) as well as the issuance of combined construction and operating licenses (COLs), early site permits (ESPs), and standard plant design certifications (10 CFR Part 52) [1]. New reactor designs, however, require modified design response spectra (MDRS) by broadening the high-frequency range from design response spectra (DRS) in RG 1.60. In order to generate artificial time histories to meet the acceptable criteria described in NUREG-0800 [2], it9s necessary to develop the power spectral density of the MDRS. In this paper, we generate the artificial earthquake time histories of the MDRS for further research.
        1 2 3 4 5