        381.
        2013.04 서비스 종료(열람 제한)
        In order to evaluate earthquake response of structures affected by shallow soft soil deposits, centrifuge tests were performed. The test specimen was composed of a single-degree-of-freedom structure model, a shallow foundation and sub-soil deposits in a centrifuge container. The structure response directly measured from the test showed that a large rocking rotation occurred due to the soil-foundation interaction. Thus, the acceleration of the structure was significantly smaller than the fixed base structure response.
        382.
        2013.04 서비스 종료(열람 제한)
        This study presents the application of seismic performance evaluation methods specialized in dam and reservoir structures in Korea. Related criteria and evaluation methods are reviewed, and then, the indicators needed to perform the seismic performance evaluation and how to take advantage of these are suggested in this study.
        383.
        2013.04 서비스 종료(열람 제한)
        In this study, the optimal performance based seismic retrofit method for fiber-reinforced polymer (FRP) jackets in existing reinforced concrete (RC) frames is presented. This optimal method minimizes the amount of FRP material while satisfying the constraints on the maximum inter-story drift, maximum strain of concrete, and shear failure prevention of columns. Both of shear reinforcement for preventing shear failure of columns and flexural reinforcement for improving the flexural capacity of columns are simultaneously considered. This method is applied to 3-story RC frame and the reinforced locations and the numbers of FRP reinforcement plies are obtained.
        384.
        2013.04 서비스 종료(열람 제한)
        This study is to evaluate structural strengthening performance of lightly reinforced concrete frame retrofitted with infill wall experimentally. In order to evaluate the performance concrete and SFRC infill walls. The weariable is presence of fiber and the wall panel is 1/3 scale models. The result of this study, the SFRC wall specimen, the maximum load and displacement go increase than concrete wall.
        385.
        2013.01 KCI 등재 서비스 종료(열람 제한)
        본 연구는 우리나라에서 가장 일반적인 중소규모의 비내진 상세를 가진 건축물을 대상으로, 노후도를 고려하여 내진성능을 평가하였다. 평가결과, 준공 후 24년이 경과되었으나 노후도는 대체로 양호한 것으로 평가되었고, 1차, 2차 내진성능평가는 기준지표를 만족하지 못하는 것으로 나타났다. 3차 내진성능평가에서는 층간변위비를 기준으로 목표성능은 만족하지만 보강이 필요한 것으로 판단되었다. 대상 건축물에 벽체보강, 가새보강, 댐퍼보강을 한 후 내진성능평가를 실시한 결과, 보강방법에 상관없이 층간변위비는 현저히 감소하여 즉시거주수준을 만족하는 수준으로 나타났다. 그러나 벽체보강의 경우 밑면전단력이 2배 이상 증가되어 기존기초에 대한 검토가 필요하다.
        386.
        2012.11 서비스 종료(열람 제한)
        To evaluate the seismic performance of CFFT pier reinforced by FRP, quasi-static loading tests have been conducted using the real-scaled specimens in this study. The cast in placed CFFT specimen and the precast CFFT specimens were used in these tests. From the results of the tests, it is observed that the ultimate deformation and the ductility can be improved by FRP reinforcement though the hoop reinforcement is minimized.
        387.
        2012.11 서비스 종료(열람 제한)
        This study conducted seismic performance evaluation of externally reinforced water tank using shaking table test. From the shaking table test result, externally reinforced system shows sufficient stiffness for water tanks and high natural frequency over 8Hz. The test result also showed safety result of induced maximum stress of water tank shown in the allowable stress.
        388.
        2012.11 서비스 종료(열람 제한)
        The objective of this research is to investigate the seismic performance of square reinforced concrete bridge piers with solid and hollow cross section. Test specimens were nonseismically designed with the aspect ratio 4.5 Two reinforced concrete columns were tested under constant axial load while subjected to lateral load reversals with increasing drift levels.
        389.
        2012.11 서비스 종료(열람 제한)
        In this study, experimental research was carried out to improve and evaluate the seismic performance of reinforced concrete beam-column joint using carbon fiber sheets in existing reinforced concrete building. Test result shows that retrofitting specimen(LBCJ-CS1, CS2) designed by the improvement of seismic performance of reinforced concrete beam-column joints load-carrying capacities were increased 1.26~1.35 times in comparison with the standard specimen.
        390.
        2012.11 서비스 종료(열람 제한)
        Reinforced concrete coupled shear wall systems in medium and high-rise construction, where RC beams couple two or more RC walls have been frequently used. The objective of this study is to investigate seismic performance of coupling beam with headed bar.
        391.
        2012.11 서비스 종료(열람 제한)
        Coupling beams of coupled shear wall systems are often the most critical members in medium or high rise buildings subject to seismic load or wind loads. To ensure the survival of shear walls under high-intensity cyclic loading, these beams, which normally have limited dimensions, should possess high deformability and good energy absorption while being able to resist large shear force. Experimental work are conducted to illustrate the design of special RC coupling beams using the proposed procedure reinforcement details.
        392.
        2012.09 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 비내진 교각의 내진성능과 휨-전단 거동을 파악하고자 형상비 4.5인 정사각형의 중실 및 중공단면 철근콘크리트 교각실험체를 제작하여 일정한 축력하에서 변위비 등급을 증가시켜 가면서 횡하중을 가력하는 실험을 수행하였다. 본 연구는 철근콘크리트 교각의 한정연성 내진설계를 위한 실험적 기초자료의 제공과 함께 성능단계별 교각성능 및 손상평가를 위한 정량적 수치와 경향을 제공하기 위한 것이며, 파괴거동, 극한변위, 극한드리프트비율, 변위연성도, 응답수정계수, 등가점성감쇠비, 잔류변형지수, 유효강성, 철근 변형률 등의 주요 내진성능 인자들에 대한 분석결과와 비선형 해석 결과를 나타내었다.
        393.
        2012.05 서비스 종료(열람 제한)
        To evaluate seismic performance of existing school buildings, This study performed pushover analysis using Midas/Gen Ver.795. The outcome shows that building have insufficient seismic performance and seismic reinforcement is necessary to have enough seismic performance.
        394.
        2012.05 서비스 종료(열람 제한)
        This experimental study evaluates of seismic performance on strain-hardening cement-based composite (SHCC). The objective of this study is to evaluate of cross-sectional reduction (1400×800×70 and 1120×520×40㎜) and design compressive strength level (45 and 50 MPa). The experimental results as cross-sectional reduction, peak loads are not significantly different. but energy area is decrease.
        395.
        2012.05 서비스 종료(열람 제한)
        The objective of this study is to investigate the seismic performance of hybrid coupled shear wall connection with new toughness material, pseudo strain hardening cementitious composites (PSH2C). Test variable of this study is the embedment length of steel coupling in connection region. The results showed that Specimen PSH2C-ST with longer embedment length of steel coupling beam exhibits good seismic performance than Specimen PSH2C-STE.
        396.
        2012.05 서비스 종료(열람 제한)
        This paper experimentally evaluates effects of fiber ratio of the seismic performance of infill walls. Variable of study was a concrete and fiber ratio (PVA1.3+PE0.2 and PVA0.75+PE0.75). The experimental investigation consisted of cyclic loading tests on 1/3-scale models of infill walls. The experimental results show that SHCC specimens was more ductile behavior.
        397.
        2012.01 KCI 등재 서비스 종료(열람 제한)
        최근 PC 공법을 도입하려는 시도가 많이 이루어지고 있다. 그러나 PC 벽체에 대한 연구는 개발의 어려움이 있어 상대적으로 더디게 발전되어 왔다. 본 연구에서는 PC벽체의 기존의 접합부의 시공성 및 구조성능을 개선하기 위하여 수직접합부의 개선안을 개발하였고, 이에 대한 구조성능평가를 진행하였다. 제안된 PC벽체의 수직접합부 구조적인 성능을 검증하기 위하여 반복적인 횡하중 재하시험을 진행한 결과, 기존의 일체형 PC벽체와 동등이상의 내진성능을 발휘하는 것으로 나타나 향후 구조물의 주요 횡력저항요소로 충분히 적용가능할 것으로 판단된다.
        398.
        2011.07 KCI 등재 서비스 종료(열람 제한)
        일반적으로 조적조는 시공이 용이하고 경제적인 구조로서 국내뿐만 아니라 해외에서도 가장 오래되고 광범위하게 사용되는 구조이다. 조적벽을 RC 골조에 장막벽으로 사용하는 채움벽 형태의 구조는 시공이 용이하고 경제적이기 때문에 저층 주거용 건물, 학교건물 등에 많이 적용되고 있으나, 설계시에는 비구조부재로 취급되어 채움벽의 효과를 반영하지 않고 있다. 본 연구에서는 기존의 사각형 조적개체의 횡력에 대한 취약성을 개선하기 위해 개발된 육각형 블록을 RC 골조 채움벽에 적용한 채움벽 골조에 대한 구조실험을 수행하여 육각형블록 조적채움벽의 효과를 평가하고자 하였다.
        399.
        2011.05 KCI 등재 서비스 종료(열람 제한)
        철근콘크리트 보-기둥 접합부는 철근의 복합적인 배근으로 인하여 시공성이 저하되고 철근의 정착공간이 협소하여 정착파괴가 발생할 가능성이 높다. 또한 지진하중 하에서 기둥 또는 접합부의 파괴는 구조물 전체의 파괴를 야기할 수 있기 때문에 기둥 표면에서 일정한 거리이상 떨어진 보에 소성힌지를 발생시켜 보의 파괴가 선행된 후에 기둥 및 접합부가 파괴되는 강기둥-약보의 설계 개념을 적용하여 구조물의 안전성을 확보하고 있다. 본 연구에서는 이러한 접합부의 강도 증가 및 시공성 향상을 도모하고 소성힌지를 보의 내측방향으로 이동시키기 위한 방안으로 보 주인장 철근과 접합부 보강 철근으로 헤디드 바를 활용하고자 하였다. 이를 위해 헤디드 바로 보강된 철근콘크리트 보-기둥 접합부에 대해 3차원 유한요소 해석을 수행하였다. 해석결과의 정확성을 검증하기 위하여 선행연구자에 의해 실험된 부재와 동일한 변수에 대한 해석을 수행하여 그 결과를 비교하였으며, 헤디드바의 우수성을 확인하기 위한 변수를 추가하여 해석을 수행하였다. 해석결과 보 주인장 철근의 정착방법으로 헤디드 바를 사용함으로써 유사한 구조성능 하에서 시공성 향상을 도모할 수 있음을 확인하였다. 또한 헤디드 바를 접합부에 보강함으로써 설계자가 의도한 위치에 소성힌지를 발생시킬 수 있었으며, 주기하중 하에서 에너지 소산능력의 증가, 강성 감소의 최소화 및 극한응력을 향상시키는 결과를 얻었다.
        400.
        2011.05 KCI 등재 서비스 종료(열람 제한)
        지하역사의 대부분은 지진에 대비한 내진설계가 거의 수행되지 않음으로 인하여 일정규모 이상의 지진이 발생할 경우 대규모 인명 및 재산피해가 우려된다. 지중구조물인 지하역사의 신뢰도 높은 내진성능 평가를 위하여 지진하중 재하 시 지반과 구조물의 상호작용이 고려된 거동의 고찰과 검증이 요구된다. 이에 본 연구에서는 수도권 소재의 실제 지하역사에 대하여, 상사비 1/60 스케일의 축소모형 지하역사 구조물 시험체에 장주기인 Kobe지진파와 단주기인 Northridge지진파를 적용한 원심모형 진동대 시험을 수행하였다, 원심모형시험결과와 응답변위법, 동일단면에 대해 SHAKE91에 의한 지반 및 구조물의 상대변위, 구조물의 모멘트에 대하여 비교․분석함으로써 지하역사의 내진성능을 평가하고자 하였다.