검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 331

        42.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Single-layered grid space steel roof structure is an architectural system in which the structural ability of the nodal connection system greatly influences the stability of the entire structure. Many bolt connection systems have been suggested to enhance for better construct ability, but the structural behavior and maximum resistance of the connection system according to the size of bolt clearance play were difficult to identify. In particular, the identification of bending stiffness of the connection system is very important due to the characteristics of shell structures in which membrane stresses based on bending force effect significantly. To identify effective structural behavior and maximum bearing force, four representative nodal connection systems were selected and nonlinear numerical analysis were performed. The numerical analysis considering the size of the bolt clearance were performed to investigate structural behavior and maximum values of the bending force. In addition, the type of effective nodal connection system were evaluated. As a result, the connection system, which has two shear plane, represented high bending stiffness.
        4,000원
        43.
        2020.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 시스템 다이내믹스를 기반으로 해양구조물 분리시스템(Separation system)의 설계검증 방법을 제안하였다. 해양구조물 분리시스템은 부가가치 측면에서 EPC 프로젝트의 성공 여부를 결정할 수 있는 상부구조(Topsides)의 가장 중요한 시스템 중 하나이다. 그럼에도 불구하고, 설계검증에 대한 지금까지의 실태는 설계 작업의 프로세스 진행이나 도면작성 및 제공에 국한되어 있어 기본설계 단계에서 설계검증의 미흡으로 인하여 계약 후 잦은 설계변경에 의한 기업손실이 발생되어 왔다. 이러한 맥락에서 본 연구의 목적은 해양구조물의 전체 프로젝트 수행 기간에 성공적인 사업수행을 도모하고자 설계검증 모델을 구축하여 적용하도록 하였다. 제안된 설계검증 방법은 상세 설계의 효과적인 실행뿐만 아니라 초기설계 단계에서 기술적 오류나 불일치 사항을 미리 찾아냄으로써 해양구조물의 엔지니어링, 조달 및 건조에 대한 경쟁력을 향상시키는데 기여 할 것으로 예상한다. 본 연구에서는 먼저 건조한 실적선 자료를 바탕으로 설계검증을 수행하여 FPSO 분리시스템에 적용하고 ISO 15288 국제 표준을 준수하였다. 결과적으로, 제안된 설계검증 방법이 해양구조물의 FEED 검증 프로세스에 적용될 수 있으며, 향후 해양 프로젝트의 성공적인 수행에 의한 이익창출을 도모할 수 있을 것이다. 또한, 해양구조물 건조 시 설계변경 에 의한 막대한 손실을 최소화 할 수 있을 것으로 기대한다.
        4,000원
        44.
        2020.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Seismic qualification of equipment including piping is performed by using floor response spectra (FRS) or in-structure response spectra (ISRS) as the earthquake input at the base of the equipment. The amplitude of the FRS may be noticeably reduced when obtained from coupling analysis because of interaction between the primary structure and the equipment. This paper introduces a method using a modal synthesis approach to generate the FRS in a coupled primary-secondary system that can avoid numerical instabilities or inaccuracies. The FRS were generated by considering the dynamic interaction that can occur at the interface between the supporting structure and the equipment. This study performed a numerical example analysis using a typical nuclear structure to investigate the coupling effect when generating the FRS. The study results show that the coupling analysis dominantly reduces the FRS and yields rational results. The modal synthesis approach is very practical to implement because it requires information on only a small number of dynamic characteristics of the primary and the secondary systems such as frequencies, modal participation factors, and mode shape ordinates at the locations where the FRS needs to be generated.
        4,000원
        45.
        2020.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we propose a new truss deckplate system, which does not require temporary floor supports during construction, with ultra-high-performance concrete (UHPC) infilled top bars. The increased stiffness and strength of the proposed system were well retained as compared to those of the existing truss deckplate systems, thereby resulting in the reduction of maximum deflection at the span center. Four-point bending tests were performed on five specimens with a net span of 4.6 m to evaluate the structural performance of proposed system in the construction stage. In addition, the load-deflection curve was plotted for each specimen, and the effects of test parameters were analyzed. Further, a rigorous nonlinear three-dimensional finite element analysis was performed, and its results were compared with the test results. From the results, it was observed that the test specimens of the proposed system exhibited superior performance as compared to those of the existing one and also satisfied the serviceability requirement during construction provided by the Korea Building Code 2016.
        4,000원
        46.
        2020.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to propose future-oriented high-rise buildings where the vehicle is parked at the top of the building. At the same time, the vehicle is used as a part of the building along with the advent of the era of autonomous driving. The suspended structure is proposed as a suitable structural system for architectural planning. This system is free to design because there are no limitations on column planning compared to conventional designs. In particular, the low-floor plan can be used as an open space because colums are not arranged in the lower-floors. Thereby opened low-floor plan has advantages that visual perception of the space is improved, noise problems along the side of the street is solved and planning underground parking spaces are easier. These advantages can solve the problem of overlapping columns with vehicle traffic in the building. However, there are some problems that the suspension structure is mainly a formal form and the usable area is small compared to the core area because it is a core-oriented structural system. In this regard, a new structural system was proposed by combining the concept of suspended structure and cable stayed column. Therefore, this paper analyzes the existing style of high-rise housing suspended Structure and proposes a new structural system and the concept of design for autonomous vehicles.
        4,000원
        47.
        2020.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Numerical analysis has been carried out to analyze seawater flow field and power generation characteristics of the tidal current power generation system for various multi channel shroud systems. Geometrical multi channel arrangement largely affects the flow field characteristics in the shroud system which power generation performance through turbine blade depends on. Sectional averaged velocity in front of the turbine blade which increases more than 2 times compared with channel inlet is much influenced as well as the flow from the rear with curl. And flow variation results in high inlet velocity in horizontal arrangements of multi channels with mechanical output of the turbine. These results are expected to be used as applicable data for the development of the tidal power generation system with shrouds.
        4,000원
        48.
        2019.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        구조물의 상태를 조기에 파악하기 위한 구조물 건전도 모니터링 연구와 건물의 정보를 수집하여 에너지를 효율적으로 관리해 주는 건물에너지관리시스템에 관한 연구가 활발히 진행 중이다. 본 연구에서는 기존 모니터링 시스템 연구가 건설, 센싱, ICT 기술이 융합된 첨단 기술임에도 불구하고 고가의 센서와 전문적인 기술력이 요구되어 적용 범위가 제한된다는 한계를 극복하기 위하여 싱글보드컴퓨터 중 가장 널리 쓰이는 라즈베리파이와 저전력으로 장거리의 통신이 가능한 로라 모듈, 고성능의 보급형 가속도계를 활용하여 장기간으로 건물의 모니터링이 가능한 무선 엣지 컴퓨팅 시스템을 구축하였다. 또한 라즈베리파이에 분산처리 알고리즘을 탑재함으로써 실시간으로 취득되는 방대한 양의 가속도 데이터 중 의미있는 데이터만을 취득하였으며 와이파이 통신으로 취득한 전체의 로우데이터와 비교함으로써 본 시스템으로부터 취득된 데이터의 정밀성을 검증하였다.
        4,000원
        49.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A hybrid mid-story seismic isolation system with a smart damper has been proposed to mitigate seismic responses of tall buildings. Based on previous research, a hybrid mid-story seismic isolation system can provide effective control performance for reduction of seismic responses of tall buildings. Structural design of the hybrid mid-story seismic isolation system is generally performed after completion of structural design of a building structure. This design concept is called as an iterative design which is a general design process for structures and control devices. In the iterative design process, optimal design solution for the structure and control system is changed at each design stage. To solve this problem, the integrated optimal design method for the hybrid mid-story seismic isolation system and building structure was proposed in this study. An existing building with mid-story isolation system, i.e. Shiodome Sumitomo Building, was selected as an example structure for more realistic study. The hybrid mid-story isolation system in this study was composed of MR (magnetorheological) dampers. The stiffnessess and damping coefficients of the example building, maximum capacity of MR damper, and stiffness of isolation bearing were simultaneously optimized. Multi-objective genetic optimization method was employed for the simultaneous optimization of the example structure and the mid-story seismic isolation system. The optimization results show that the simultaneous optimization method can provide better control performance than the passive mid-story isolation system with reduction of structural materials.
        4,000원
        50.
        2019.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A seismic isolation system is one of the most effective control devices used for mitigating the structural responses due to earthquake loads. This system is generally used as a type of base isolation system for low- and mid-rise building structures. If the base isolation technique is applied to high-rise buildings, a lot of problems may be induced such as the movement of isolation bearings during severe wind loads, the stability problem of bearings under large compression forces. Therefore, a mid-story isolation system was proposed for seismic protection of high-rise buildings. Residence-commerce complex buildings in Korea have vertical irregularity because shear wall type and frame type structures are vertically connected. This problem can be also solved by the mid-story isolation system. An effective analytical method using super elements and substructures was proposed in this study. This method was used to investigate control performance of mid-story isolation system for residence-commerce complex buildings subjected to seismic loads. Based on numerical analyses, it was shown that the mid-story isolation system can effectively reduce seismic responses of residence-commerce complex tall buildings.
        4,000원
        52.
        2019.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        2017년 발생한 포항 지진으로 인하여 천장재, 외장재, 커튼월 등 비구조재의 파괴에 의한 피해가 다수 보고되었으며 비구조재의 내진설계가 중요해지고 있다. 본 연구에서는 임팩트해머 테스트를 통해 행어볼트 길이에 따른 천장재의 고유진동수와 감쇠비를 식별하였다. 또한 천장재가 벽 또는 다른 구조체에 충돌하는 경우 발생하는 충격효과를 정확히 고려하기 위해 충돌실험을 수행하였다. 식별된 천장재의 동특성과 충격지속시간을 바탕으로 실제로 천장재가 지진하중으로 인하여 주변 구조물과 충돌이 발생하는 경우에 대한 천장재 응답특성을 수치해석을 통하여 분석하였다. 수치해석 시뮬레이션 결과, 충격하중은 이격거리에 따라 선형적으로 증가하는 경향을 보였으며, 달대길이와는 무관한 것으로 나타났다.
        4,000원
        53.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        국내 고층 아파트의 구조시스템은 크게 다수의 벽체가 분산적으로 배치되어 있는 내력벽 시스템과 중앙 코어벽 시스템으 로 구분할 수 있다. 각각 시스템에 따른 횡방향 거동을 분석하기 위해 본 연구는 국내 고층 아파트 중 대표적인 평면을 갖는 대상 건물을 선정하고, 비선형 정적해석을 수행하여 붕괴메커니즘을 살펴보았다. 비선형 정적해석을 통해 도출된 힘-변위 관계로부터 지진응답에 있어서 중요한 요소인 초과강도계수 및 연성도계수를 산정하여 반응수정계수를 평가하였다. 중앙 코어벽 시스템은 연성도는 작지만, 풍하중에 의해 지배되어 초과강도가 크게 산정돼 초과강도계수에 의해 반응수정계수가 산정되었고, 내력벽 시스템은 벽량이 많아 연성도가 크기 때문에 상당힌 큰 반응수정계수가 산정된다.
        4,000원
        54.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the seismic response is investigated by using a relatively low-rise building under torsion-prone conditions and three seismic loads with change of the location of the seismic isolation system. LRB (Lead Rubber Bearing) was used for the seismic isolator applied to the analytical model. Fixed model without seismic isolation system was set as a basic model and LB models using seismic isolation system were compared. The maximum story drift ratio and the maximum torsional angle were evaluated by using the position of the seismic layer as a variable. It was confirmed that the isolation device is effective for torsional control of planar irregular structures. Also, it was shown that the applicability of the midstory seismic isolation system. Numerical analyses results presented that an isolator installed in the lower layer provided good control performance for the maximum story drift ratio and the maximum torsional angle simultaneously.
        4,000원
        55.
        2019.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A smart connective control system was invented recently for coupling control of adjacent buildings. Previous studies on this topic focused on development of control algorithm for the smart connective control system and design method of control device. Usually, a smart control devices are applied to building structures after structural design. However, because structural characteristics of building structure with control devices changes, a iterative design is required for optimal design. To defeat this problem, an integrated optimal design method for a smart connective control system and connected buildings was proposed. For this purpose, an artificial seismic load was generated for control performance evaluation of the smart coupling control system. 20-story and 12-story adjacent buildings were used as example structures and an MR (magnetorheological) damper was used as a smart control device to connect adjacent two buildings. NSGA-II was used for multi-objective integrated optimization of structure-smart control device. Numerical simulation results show the integrated optimal design method proposed in this study can provide various optimal designs for smart connective control system and connected buildings presenting good control performance.
        4,000원
        57.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to remove rust and impurities from surface of raw SUS circular bar, peeling machine is used to make lustrous and clean surface of SUS circular bar. Drawing process system is used to manufacture SUS hexagonal bar. SUS hexagonal bar have been widely used to make hexagonal bolt/nut, adapter and fittings and so on. The purpose of this study is to investigate the stabilities for guide bar of clamp in drawing process system. As the results, the guide bar showed structural stability in cases of below load of 50 Ton and over hook radius of 3.0mm. Further as the thickness of guide bar hooking with jaw was increased, minimum safety factor was decreased.
        4,000원
        58.
        2018.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문에서는 다중 재난을 고려한 복합 구조제어 시스템의 최적 설계방법을 제시한다. 한 가지 유형의 위험에 대해 하나의 시스템이 설계되는 전형적인 구조제어 시스템과는 달리, 구조물의 지진 및 바람에 의한 진동응답을 저감하기 위해 능동 및 수동제어 시스템에 대한 동시 최적 설계방법을 제안하였다. 수치 예로서, 30층 빌딩 구조물에 설치된 30개의 점성 댐퍼와 복합형 질량 감쇠기에 대한 최적 설계문제를 보였다. 최적화 문제를 풀기 위해 자체적응 화음탐색(harmony search, HS)알 고리즘을 채택하였다. 화음탐색 알고리즘은 사람이 연주하는 악기의 튜닝 과정을 모방한 전역 최적화를 위한 메타 휴리스틱 진화 연산방법의 하나이다. 또한 전역 탐색 및 빠른 수렴을 위해 자가적응적이고 동적인 매개변수 조정 알고리즘을 도입하였다. 최적화 설계 결과, 능동 및 수동 시스템이 독립적으로 최적화된 표준적인 복합제어 시스템에 비해 제안한 동시 최적제어 시스템의 성능과 효율성이 우수함을 보였다.
        4,000원
        60.
        2018.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study showed that experimental study of inelastic nonlinear behavior of two-way beam string structures. General large span structures consisting of beam members have large moment and long cross section of area. In order to decrease these excessive moment and deflection, the two-way beam string structures composed of H-Beam, strut, and cable elements were proposed. In the two-way string beam, the cable with the prestress improves force distribution of some weight reduction. Two systems made of structural steel and cables were tested. The nonlinear behaviour of the two-way beam string structures studied by using finite element model and compared to experimental results. The displacement of the LVDT in the center of the beam correspond with the ABAQUS results. 2,200MPa cable can afford to bear breaking load than 1,860MPa cable. The two-way beam string structures is correlated to the finite element model and the experimental results. In consequence, It showed that the system with two-way cables exhibits much better structural performances than H-Beam structures and beam with cable.
        4,200원
        1 2 3 4 5