        41.
        2018.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, TMD(Tuned Mass Damper) is installed in a retractable-roof spatial structure in order to investigate dynamic response characteristics according to mass ratio and installed position of TMD on large spatial structures. The example analytical model is generated based on the Singapore sports hub stadium. Twenty eight analytical models are used to investigate optimal installation position of TMD for the example retractable-roof spatial structure using 4 to 16 TMDs. The mass of one TMD is set up 1% of total mass at the example analytical model. Displacement response ratio of model with TMD is compared with that of base model without TMD. It has been found from numerical simulation that it is more effective to install TMD at the edge of the spatial structure rather than to concentrate the TMD at the center of the spatial structure.
        4,000원
        42.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The improvement in computing systems and sensor technologies devotes to conduct data-driven structural health monitoring algorithms for existing civil infrastructures. Despite of the development of techniques, the uncertainty oriented from the measurement results in the discrepancy to the actual structural parameters and let engineers or decision makers hesitate to adopt such techniques. Many studies have shown that the modal identification results can be affected by the uncertainties due to the applied methods and the types of loading. This paper aims to compare the performance of modal identification methods using Structural Modal Identification Toolsuite (SMIT) which has been developed to facilitate multiple identification methods with a user-friendly designed platform. The data fed into SMIT processes three stages for the comprehensive identification including preprocessing, eigenvalue estimation, and post-processing. The seismic and white noise response for shear frame model was obtained from numerical simulation. The identified modal parameters is compared to the actual modal parameters. In order to improve the quality of coherence in identified modal parameters, several hurdles including modal phase collinearity and extended modal amplitude coherence were introduced. Numerical simulation conducted on the 5 dof shear frame model were used to validate the effectiveness of using these parameters.
        4,000원
        43.
        2018.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The probabilistic seismic safety assessment is one of the methodology to evaluate the seismic safety of the nuclear power plants. The site characteristics of the nuclear power plant should be reflected when evaluating the seismic safety of the nuclear power plant. The Korea seismic characteristics are strong in high frequency region and may be different from NRC Regulatory Guide 1.60, which is the design spectrum of nuclear power plants. In this study, seismic response of a nuclear power plant structure by Pohang earthquake (2017.11.15. (KST)) is investigated. The Pohang earthquake measured at the Cheongsong seismic observation station (CHS) is scaled to the peak ground acceleration (PGA) of 0.2 g and the seismic acceleration time history curve corresponding to the design spectrum is created. A nuclear power plant of the containment building and the auxiliary buildings are modeled using OPENSEES to analyze the seismic response of the Pohang earthquake. The seismic behavior of the nuclear power plant due to the Pohang earthquake is investigated. And the seismic performances of the equipment of a nuclear power plant are evaluated by the HCLPF. As a result, the seismic safety evaluation of nuclear power plants should be evaluated based on site-specific characteristics of nuclear power plants.
        4,000원
        44.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to reduce the seismic response of the spatial structure, a seismic isolation system with sufficient flexibility is used. The natural period of structure with seismic isolation system got be long to avoid prominent period. In this study, The seismic response of the truss-arch structure, which is modeled in three types according to the rise-span ratio is analyzed on El-centro, Northridge and Artificial Earthquake and compared with the seismic response of the truss-arch structure with lead rubber bearing(LRB). When seismic load is applied to the truss arch with isolation system, the horizontal acceleration response of the truss arch is reduced and vertical seismic response is also reduced. The application of the seismic isolation system is effective in controlling the seismic response.
        4,200원
        45.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        계측응답에 대한 모드분해법은 대부분 물리공간에서 정의되고, 모드형상을 이용하여 일반화모드응답을 구하는데 적용된다. 구조물이 가지는 비고전 감쇠에 대한 기존 모드분해법의 한계를 극복하고 단조성을 가지는 모드형상의 분해가능성을 높이기 위하여 상태공간 모드분해법이 최근 시도되고 있다. 본 연구에서는 물리공간에서 정의되었던 모드분해법을 상태공간 모드분해법으로 확장하는 새로운 기법을 제시하고, 이들이 가지는 모드분해 특성과 분해성능을 고찰하였다. 또한 기존 물리공간에서 정의되었던 FDD, BSS 모드분해법을 상태공간 모드분해법으로 확장하는 기법을 제시하였다. 상태공간에서의 모드 확장성을 위하여 구조물의 계측 가속도를 상태변수로 변환하고 이들로 구성된 상태공간을 구성하는 방법도 고찰하였다. 상태공간으로의 확장성과 분해성능을 수치해석을 통하여 검증하였으며, 그 결과 상태공간 모드분해법이 물리공간 모드분해법에 비하여 분해성능이 우수하며, 이론적으로 정의된 상태공간 모드형상과 유사하게 모드형상을 제공하는 것으로 나타났다.
        4,000원
        46.
        2018.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The seismically isolated nuclear power plants shall be designed for design basis earthquake (DBE) and considered to ensure safety against beyond design basis earthquake (BDBE). In order to limit the excessive displacement of the seismic isolation system of the seismically isolated structure, the moat is installed at a certain distance from the upper mat supporting the superstructure. This certain distance is called clearance to stop (CS) and is calculated from the 90th percentile displacement of seismic isolation system subjected to BDBE. For design purposes, the CS can be obtained simply by multiplying the median displacement of the seismic isolation system against DBE by scale factor with a value of 3. The DBE and BDBE used in this study were generated by using 30 sets of artificial earthquakes corresponding to the nuclear standard design spectrum. In addition, latin hyper cube sampling was applied to generate 30 sets of artificial earthquakes corresponding to maximum - minimum spectra. For the DBE, the median displacement and the 99th percentile displacement of the seismic isolation system were calculated. For the BDBE, the suitability of the scale factor was assessed after calculating the 90th percentile displacement of the seismic isolation system.
        4,000원
        47.
        2017.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to improve the seismic performance of structures, friction pendulum system (FPS) is the most commonly used seismic isolation device in addition to lead rubber bearing (LRB) in high seismicity area. In a nuclear power plant (NPP) with a large self weight, it is necessary to install a large number of seismic isolation devices, and the position of the center of rigidity varies depending on the arrangement of the seismic isolation devices. Due to the increase in the eccentricity, which is the difference between the center of gravity of the nuclear structure and the center of stiffness of the seismic isolators, an excessive seismic response may occur which could not be considered at the design stage. Three different types of eccentricity models (CASE 1, CASE 2, and CASE 3) were used for seismic response evaluation of seismically isolated NPP due to the increase of eccentricity (0%, 5%, 10%, 15%). The analytical model of the seismic isolation system was compared using the equivalent linear model and the bilinear model. From the results of the seismic response of the seismically isolated NPP with increasing eccentricity, it can be observed that the effect of eccentricity on the seismic response for the equivalent linear model is larger than that for the bilinear model.
        4,200원
        48.
        2017.07 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Current seismic design provisions such as ASCE 7-10 provide criteria for selecting ground motions for conducting response history analysis. This study is the sequel of a companion paper (I – Ground Motion Selection) for assessment of the ASCE 7-10 criteria. To assess of the ASCE 7-10 criteria, nonlinear response history analyses of twelve single degree of freedom (SDF) systems and one multi-degree of freedom (MDF) system are conducted in this study. The results show that the target seismic demands for SDF can be predicted using the mean seismic demands over seven and ten ground motions selected according to the proposed method within an error of 30% and 20%, respectively
        4,000원
        49.
        2017.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In order to modeling seismic isolation system such as lead-rubber bearing (LRB), bilinear model is widely used by many researchers. In general, an actual force-displacement relationship for LRB has a smooth hysteretic shape. So, Bouc-Wen model with smooth hysteretic shape represents more accurately actual hysteretic shape than bilinear model. In this study, seismic responses for seismically isolated nuclear power plant (NPP) with LRB modelled by Bouc-Wen and bilinear models are compared with those of NPP without seismic isolation system. To evaluate effect of earthquake characteristics for seismic responses of NPP isolated by LRB, 5 different site class earthquakes distinguished by Geomatrix 3rd Letter Site Classification and artificially generated earthquakes corresponding to standard design spectrum by Reg. Guide 1.60 are used as input earthquakes. From the seismic response results of seismically isolated NPP, it can be observed that maximum displacements of seismic isolation modelled by Bouc-Wen model are larger than those by bilinear model. Seismic responses of NPP with LRB is significantly reduced than those without LRB. This reduction effect for seismic responses of NPP subjected to Site A (rock) earthquakes is larger than that to Site E (soft soil) earthquakes.
        4,000원
        50.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A retractable-roof spatial structure is frequently used for a stadium and sports hall. A retractable-roof spatial structure allows natural lighting, ventilation, optimal conditions for grass growth with opened roof. It can also protects users against various weather conditions and give optimal circumstances for different activities. Dynamic characteristics of a retractable-roof spatial structure is changed based on opened or closed roof condition. A tuned mass damper (TMD) is widely used to reduce seismic responses of a structure. When a TMD is properly tuned, its control performance is excellent. Opened or closed roof condition causes dynamic characteristics variation of a retractable-roof spatial structure resulting in off-tuning. This dynamic characteristics variation was investigated. Control performance of a passive TMD and a smart TMD were evaluated under off-tuning condition.
        4,000원
        51.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The seismic isolation system reduces the seismic vibration that is transmitted from foundation to upper structure. This seismic isolation system can be classified into base isolation and mid-story isolation by the installation location. In this study, the seismic behavior of dome structure with mid-story isolation is analyzed to verify the effect of seismic isolation. Mid-story isolation is more effective than base isolation to reduce the seismic responses of roof structure. Also, this isolation would be excellent in structural characteristics and construction.
        4,000원
        52.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Gyeong-Ju earthquake in the magnitude of 5.8 on the Richter scaleoccurred in September 12, 2016. Because there are many nuclear power plants (NPP) near the epicenter of the Gyeong-Ju earthquake, the seismic stability of nuclear power plants is becoming a social problem. In order to evaluate the safety of seismically isolated NPP, the seismic response of a NPP subjected to the Gyeong-Ju earthquake was compared with those of 30 sets of artificial earthquakes corresponding to the nuclear standard design spectrum (NSDS). A 2-node model and a simple beam-stick model were used for the seismic analysis of seismically isolated NPP structures. Using 2-node model, the effect of internal temperature rise, decrease of shear stiffness, increase of lateral displacement and decrease of vertical stiffness according to nonlinear behavior of lead-rubber bearing (LRB) were evaluated. The displacement response, the acceleration response, and the shear force response of the seismically isolated nuclear containment structure were evaluated using the simple beam-stick model. It can be observed that the seismic responses of the isolated nuclear structure subjected to Gyeong-Ju earthquake is significantly less than those to the artificial earthquakes corresponding to NSDS.
        4,000원
        53.
        2016.11 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study intends to evaluate the conservativeness of the fixed-base analysis as compared to the soil-structure interaction (SSI) analysis for the seismically isolated model of a nuclear power plant in Korea. To that goal, the boundary reaction method (BRM), combining frequency-domain and time-domain analyses in a twofold process, is adopted for the SSI analysis considering the nonlinearity of the seismic base isolation. The program KIESSI-3D is used for computing the reaction forces in the frequency domain and the program MIDAS/Civil is applied for the nonlinear time-domain analysis. The BRM numerical model is verified by comparing the results of the frequency-domain analysis and time-domain analysis for the soil-structure system with an equivalent linear base isolation model. Moreover, the displacement response of the base isolation and the horizontal response at the top of the structure obtained by the nonlinear SSI analysis using BRM are compared with those obtained by the fixed-base analysis. The comparison reveals that the fixed-base analysis provides conservative peak deformation for the base isolation but is not particularly conservative in term of the floor response spectrum of the superstructure.
        4,200원
        54.
        2016.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구는 기초의 묻힘이 면진 원전구조물의 응답에 미치는 효과를 지표기초와 비교하여 평가하였다. 면진장치의 비선형 성을 고려한 비선형 SSI 해석은 진동수영역해석과 시간영역해석의 복합법인 경계반력법(BRM)을 이용하여 수행하였다. BRM 해석모델은 BRM을 이용한 등가선형 SSI 해석결과를 재래의 주파수영역 SSI 해석결과와 비교함으로 검증하였다. 마 지막으로 비선형 SSI해석에 의한 묻힌기초 모델의 면진장치의 변위 및 구조물 응답을 지표기초의 해석결과와 비교하였다. 비교결과, 면진장치의 변위응답은 묻힌기초효과를 고려할 경우 감소할 수 있음을 알 수 있었다.
        4,300원
        55.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study analyze the dynamic response property of latticed domes according to natural frequency ratio of substructure. Through eigenvalue analysis, it is was confirmed that the half-open angle 30° and 45° dominate vibration mode of the vertical direction and the half-open angle 60° and 90° dominate vibration mode of the horizontal direction. Through the dynamic response analysis, it is was confirmed that the first frequency about total structure largely appears about the vertical and the horizontal direction regardless of half-open angle.
        4,000원
        56.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Eradi Quake System (EQS) is a seismic isolation bearing system designed to minimize forces and displacements experienced by structures subjected to ground motion. The EQS dissipates seismic energy through friction of Poly Tetra Fluoro Ethylene (PTFE) disk pad. In general, a force-displacement relationship of EQS has post yield stiffness hardening during large inelastic displacement. In this study, seismic responses of seismically isolated nuclear power plant (NPP) subjected to design basis earthquake (DBE) and beyond design basis earthquakes (150% DBE and 167% DBE) are compared considering the post yield stiffness hardening effect of EQS. From the results, it can be observed that if the post-yield stiffness hardening effect of EQS is increased, the displacement response of EQS is reduced, and the acceleration and shear responses of containment structures of NPP is increased.
        4,200원
        57.
        2016.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, Stockbridge damper was adopted to reduce the reponses of structures under earthquakes. A finite element analysis software, SAP2000, was used to simulate the structural response and the control device under dynamic loads. A 3 story frame model and the proposed control device, Stockbridge damper, were designed under laboratory conditions. In this research, a pendulum type tuned mass damper (PTMD) was also adopted in order to compare with the Stockbridge damper. Harmonic loads were applied to verity the control performance of both control devices in each mode. In results, it has been found that the Stockbirdge damper decreases significantly the responses of the structure more than the PTMD under the harmonic loadings. The El Centro and Northridge earthquakes were also applied in order to investigate the performance by both control devices. The responses of the building demonstrate that the Stockbridge damper reduces the response of the building structure during earthquakes more effectively than the PTMD.
        4,000원
        58.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구에서는 3축 방향 지반운동이 작용하는 지반-구조물 상호작용계의 비선형 지진응답 해석을 수행한다. 비선형 거동이 예상되는 구조물과 지반의 근역은 비선형 유한요소에 의해 모형을 구성한다. 기하학적 형상과 재료 성질이 균일하고 선형 거동을 가정하는 원역지반은 무한 영역으로의 에너지 방사를 정확히 고려할 수 있는 3차원 perfectly matched discrete layer에 의해 수치 모형을 구성한다. 이와 같은 지반-구조물 상호작용계의 수치모형을 사용하여 3축 방향 지반운동이 작용하는 비선형 지진-구조물 상호작용계의 지진응답해석을 수행한다. 3축 방향 지반운동이 작용하는 경우에는 입력 지반운동의 특성에 따라 시스템의 응답이 우세하게 발현되는 방향이 존재하고 그 수준 또한 정밀한 지진응답해석을 통해 산정하여야 한다. 이 연구의 해석기법은 구조물과 지반의 재료 비선형 거동, 기초와 지반 경계면에서의 경계 비선형 거동 등 다양한 비선형 지반-구조물 상호작용 해석에 확장 적용할 수 있을 것이다.
        4,000원
        59.
        2016.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 연구에서는 3축 방향 지반운동이 작용하는 지반-구조물 상호작용계의 비선형 지진응답 해석을 수행한다. 비선형 거동 이 예상되는 구조물과 지반의 근역은 비선형 유한요소에 의해 모형을 구성한다. 기하학적 형상과 재료 성질이 균일하고 선 형 거동을 가정하는 원역지반은 무한 영역으로의 에너지 방사를 정확히 고려할 수 있는 3차원 perfectly matched discrete layer에 의해 수치 모형을 구성한다. 이와 같은 지반-구조물 상호작용계의 수치모형을 사용하여 3축 방향 지반운동이 작용 하는 비선형 지진-구조물 상호작용계의 지진응답해석을 수행한다. 3축 방향 지반운동이 작용하는 경우에는 입력 지반운동의 특성에 따라 시스템의 응답이 우세하게 발현되는 방향이 존재하고 그 수준 또한 정밀한 지진응답해석을 통해 산정하여야 한 다. 이 연구의 해석기법은 구조물과 지반의 재료 비선형 거동, 기초와 지반 경계면에서의 경계 비선형 거동 등 다양한 비선 형 지반-구조물 상호작용 해석에 확장 적용할 수 있을 것이다.
        4,000원
        60.
        2016.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 부유구조물 모델링의 효율성 및 응답의 정확성을 분석하기 위해 유체 영역을 압력으로 정의한 유탄성 해석법에 1차원 보-2차원 유체 결합의 1차원 문제와 2차원 판-3차원 유체 결합의 2차원 문제를 적용하여 수치해석을 수행하였다. 그리고 1차원 문제와 2차원 문제의 모델링 차원에 따른 응답을 비교하기 위해 다양한 평판의 변장비와 입사파의 조건을 적용하였다. 이에 따르면 강체거동의 영향이 큰 장주기파에서는 변장비가 변하더라도 두 문제의 유탄성 응답이 거의 유사하게 나타나지만 탄성거동의 영향이 지배적인 단주기파에서는 모델링 차원에 따라 뚜렷한 차이가 발생한다. 즉, 1차원 보 모델은 비록 입사파의 각도는 고려할 수 없지만 평판의 변장비가 클 경우에 유탄성 해석에 적용이 가능하다. 또한, 2차원 평판보다 단순화된 모델링 조건으로서 부유구조물의 전반적인 응답을 분석할 수 있을 뿐만 아니라 수치해석의 효율을 높일 수 있다.
        4,000원