        101.
        2018.04 서비스 종료(열람 제한)
        The target in the design of base isolated structures is the selection of isolation system properties so that optimal performance is achieved among seismic levels and performance metrics. To withstand very rare ground motions, isolation system are frequently designed with significant strength or damping, and as a result such devices provide reduced isolation effect for more frequent seismic events. To investigate improvements to the design of isolated structures, a lot of research program is performed. Experimental investigations are presented to characterize smart base isolation capable of progressively exhibiting different hysteretic properties at different stages of response. Shear tests are conducted along the ISO standard, including harmonic characterizations tests. These tests included various input intensities, multi-component excitation. Behavior of the new smart base isolation system is compared with that of linear isolation systems with both nonlinear viscous and bilinear hysteretic energy dissipation mechanisms.
        102.
        2018.02 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 세장체의 연속적인 거동을 전체 길이에 대하여 측정할 수 있는 계측시스템을 선정하며, 선정된 수중카메라 시스템의 성능평가를 수행한다. 수중카메라의 기초성능평가를 위하여 강체파이프의 강제가진 실험을 수행한다. 파이프의 상단을 강제가진장치에 고정시킨 후, 일정주기와 진폭으로 가진시켜 수중카메라를 이용하여 변위를 측정한다. 강제가진장치에 입력된 신호와 수중카메라에 계측된 신 호를 비교하여 측정 정밀도를 평가한다. 연속체인 세장체 파이프의 강제가진 실험을 수행하여, 수중카메라 시스템의 실시간 3차원적인 측정 가능성을 정성적으로 평가한다. 본 수중카메라 시스템은 향후 국내 심해공학수조에 적용되어, 세장체구조물 및 계류선 등의 거동 측정에 활용 될 것이다.
        103.
        2017.04 서비스 종료(열람 제한)
        Due to limited human resources, budget and difficulties in accessibility, inspections are not available at proper time. Advanced Technology such as ICT, Sensing, and AI can innovate the management of structure. So, we introduce our developed equipment and future management plan.
        104.
        2017.04 서비스 종료(열람 제한)
        This study is a part of the research on the development of safety monitoring system and monitoring program of 3MW offshore wind support structure using fiber optic sensor. In this paper, we propose a maintenance system for offshore wind support structure using fiber optic sensor based on the analysis of current monitoring status and related standards of domestic and overseas offshore wind support jacket structures.
        106.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        Due to limited human resources, budget and difficulties in accessibility, inspections are not available at proper time. Advanced Technology such as ICT, Sensing, and AI can innovate the management of structure. So, we introduce our developed equipment and future management plan.
        107.
        2017.01 KCI 등재 서비스 종료(열람 제한)
        This study is a part of the research on the development of safety monitoring system and monitoring program of 3MW offshore wind support structure using fiber optic sensor. In this paper, we propose a maintenance system for offshore wind support structure using fiber optic sensor based on the analysis of current monitoring status and related standards of domestic and overseas offshore wind support jacket structures.
        108.
        2016.04 서비스 종료(열람 제한)
        In this study, wind fragility for anchor systems installed at sign structures was developed through Monte Carlo simulation method. The fragility is a conditional limit state probability, presented as a function of the 3-second gust wind speed, based on a relation between statistics of wind loads and anchor system resistances. Advertisement sign attached to concrete wall structure was investigated using probabilistic approach with consideration of anchor type, exposure category, and wind directionality. The results showed that the failure due to tension on anchor bolt was dominant and occurred at a very high wind speed. The fragility methodology described in this paper can be used to develop performance-based design guidelines for advertisement structure in high wind regions as well as to provide information on which to base structural safety or expected loss assessments.
        109.
        2016.04 서비스 종료(열람 제한)
        To minimize damage from disasters, various aspects of prevention, preparation, and response, etc. are being managed. A system that can share the identical disaster information based on prompt disaster management and prediction must be developed and constructed for integrated disaster management.
        110.
        2015.12 KCI 등재 서비스 종료(열람 제한)
        This study investigated structure and function of the reproductive system in Aplysia kurodai by means of anatomical, histological, and histochemical observation. Reproductive system of this species is consisted of ovotestis, small hermaphroditic duct, ampulla, accessory genital mass and large hermaphroditic duct. The ovotestis is composed of a large number of follicles, and both oocytes and spermatocytes matured in the same follicle. The small hermaphroditic duct is a single tube and contains a swelling, the ampulla, which functions as a storage organ for endogenous sperm and an oviduct. The accessory genital mass is connected to both the small and large hermaphroditic duct, and consisted of three glands: albumen, membrane (winding) and mucus gland. The albumen gland is consisted of granular cells producing basophilic and neutral mucopolysaccharides. The membrane and mucus gland are consisted of granular cells producing acidophilc and sulfated mucopolysaccharides. The large hermaphroditic duct is a single tubular gonoduct linking the accessory genital mass to the common genital aperture but is consisted of two parallel compartments. Internally, these two compartments are incompletely divided by internal septum or fold, which are called as the red hemiduct and white hemiduct, respectively. The red hemiduct functions as an oviduct and the white hemiduct functions as a copulatory duct. The reproductive system of A. kurodai is externally comprised a single tube, i.e., monaulic type. However, internal structure of duct is incompletely divided into oviduct and copulatory duct, i.e., the oodiaulic type.
        111.
        2015.04 서비스 종료(열람 제한)
        The purpose of this study is able to prevent accidents as users will tell you in real time the long distance is to the safety inspection of various structures using a 3D scanner therefore, it is possible to use civil engineering structures, such as building structures
        112.
        2015.04 서비스 종료(열람 제한)
        Unconditional usage of multi-layered waterproofing membrane system is common in large scale spatial structures in the contemporary setting. This study aims to evaluate the limitation of multi-layered waterproofing membrane system applied to the roofing system of large scale spatial structure and examine thoroughly whether such systems are suitable for steel plate concrete or not.
        113.
        2015.03 KCI 등재 서비스 종료(열람 제한)
        This study intended to analyze an influence of the structure elements on the optimal location for one-outrigger system in tall building by using MIDAS-Gen. In this investigation, the analysis parameters were the outrigger position and the stiffness of main structure elements such as shear walls, outrigger systems, exterior columns connected in outrigger system and frames not to be connected in outrigger system. For the objective of finding out the optimal location for one-outrigger system in high-rise building, we studied the lateral displacement in top level of 80 stories building. The results of this study indicated that the outrigger location and the stiffness of main structure elements such as shear walls, outrigger systems, exterior columns connected in outrigger system and frames not to be connected in outrigger system had an influence on the optimal location of one-outrigger system. In addition, it is showed that the research results can be very useful in obtaining the structure design data for looking for the optimal location of one-outrigger system in high-rise building.
        114.
        2014.10 서비스 종료(열람 제한)
        This paper introduce a calculation method for the length of steel and rebar due to load onto the member in large scale structure using precast composite structure system. As result, cost effectiveness of members in large scale structure is procurable by utilizing steel and rebar economically.
        115.
        2014.10 서비스 종료(열람 제한)
        In this study, subject to the new shape vibration damping system that can be reused, it performed response analysis. It have developed the analysis model which can be effectively reflect the structural properties of the damping system is verified through the analysis and experimental results of existing. And it analyzed the response characteristics of the developed damping system through the analysis result.
        116.
        2014.10 서비스 종료(열람 제한)
        Through Estimation of stress distribution, both value and location of the maximum stress can be found. and the maximum stress is very important indicator for structural safety evaluation. In this connection, a lot of studies to estimate stress distributions are conducted. But studies on the optimal number and location of measurement points are few. So, In this study, the effects of the number and location of measurement points on the estimation stress distribution for the steel beam structure using motion capture system and cubic smoothing spline interpolation are researched.
        117.
        2014.10 서비스 종료(열람 제한)
        In this paper, it proceed the fascinating experimental study to use the system identification(SI) for a long time measurement. The aim of the study is to identify the dynamic characteristics using the SI based on ambient vibration(AV) tests for monitoring systems at building structures. White noise, which is naturally occurring for harmonic components, and free vibration tests are employed in obtaining output data. A definite answer of the dynamic characteristics manages to extract from the frequency domain decomposition(FDD) method under the condition of the white noise. The singular value of the following test is used by FDD. These results show the validity of AV test and the usability of FDD in comparison with two tests. The result of the study is to design practical criteria for SI for building structures based on AV tests.
        118.
        2014.04 서비스 종료(열람 제한)
        The floating PV generation system is consisted of unit structures linked by the hinge type connection because the effect of bending moment in the structural system loaded due to the unstable movement of water surface can be minimized. In this paper, the investigation and development process of floating PV generation unit structure is presented.
        119.
        2014.04 서비스 종료(열람 제한)
        Recently, the rotational solar tracker system is presented for the high electric efficiency. The horizontal rotation tracker is the structure for rotationg horizontally the most important part. However, it is difficult to secure the safety and maintenance in solar tracker systems. Therefore, this study suggests the reasonable structure type for horizontal rotational solar tracker through the strength reinforcement of the structure to ensure stability.
        120.
        2014.04 서비스 종료(열람 제한)
        In this paper, decentralized data process based system identification(SI) method for building structure is proposed. For verification of the method, an experimental study was performed and the validity of the method was confirmed using unused displacement response in SI.