검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 305

        121.
        2015.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Cooling towers have been widely applied to control the indoor temperature in the residential area and the living space. At operating the cooling towers, motor, fan and dropping water produce noise and vibration, which diffuse through the air or the solid object, polluting the environment. The standards can be used at estimating noise and vibration emission by showing remarkable economic or social benefits. The purpose of this study is to show the characteristics, measurement methods for the evaluation of noise and vibration in cooling tower.
        4,000원
        122.
        2015.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        GRP pipe (Glass-fiber Reinforced Plastic Pipe) lines making use of FRP (Fiber Reinforced Plastic) are generally thinner, lighter, and stronger than the existing concrete or steel pipe lines, and it is excellent in stiffness/strength per unit weight. In this study, we present the result of field test for buried GRP pipes with large diameter(2,400mm). The vertical and horizontal ring deflections are measured for 387 days. The short-term deflection measured by the field test is compared with the result predicted by the Iowa formula. In addition, the long-term ring deflection is predicted by using the procedure suggested in ASTM D 5365(ANNEX) in the range of 40 to 60 years of service life of the pipe based on the experimental results. From the study, it was found that the long-term vertical and horizontal ring deflection up to 60 years is less than the 5% ring deflection limitation.
        4,000원
        123.
        2015.02 KCI 등재 구독 인증기관 무료, 개인회원 유료
        이 논문은 화재에 노출된 철근콘크리트 구조에 대한 수치해석 모델을 제시하고, 기존의 자료 및 설계 규준과의 비교를 통해 구조물의 설계 시 고려 사항에 대해 제안하고 있다. 수치해석은 비정상 열전달 해석과 비선형 구조해석의 두 단계로 수행되며, 비정상 열전달 해석을 통해서 얻어진 화재시간에 따른 단면 온도분포를 바탕으로 비선형 구조해석하여 부재의 상태에 대한 정보를 얻게 된다. 이때, 철근콘크리트의 재료모델을 화재진행상태(Under-Fire)와 화재종료 후 냉각상태(After-Cooling)로 나뉘어 해석수행하여 각각의 재료상태에 따른 거동의 변화를 살펴본다. 해석된 결과는 여러 구조물에 대해 기존의 실험결과와 비교하여 검증하고, 설계 규준과의 비교를 통해 화재 시 구조물의 안전성에 대해 고찰하였다.
        4,500원
        124.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 냉각코일과 리튬브로마이드 수용액을 활용 하여 유리 chamber 내 냉각 및 제습 실험을 수행하였다. 냉각수 온도별 냉각 효과와 리튬브로마이드 수용액의 제습량을 확인하였으며, 이를 동시에 적용하여 실험을 수행하였다. 냉각수 온도별 냉각 실험은 279K, 286K, 293K에서 각각 19K, 13K, 10K 가량 감소되는 경향을 보였다. 냉각수 온도가 낮을수록 높은 냉각 성능을 보였으며, 여름철 상하수도 온도인 293K의 물로도 충분히 작물이 생육하기 좋은 온실 내부온도를 유지할 수 있다고 판단되었다. 또한 리튬브로마이드 수용액을 활용한 제습 실험에서는 약 80%의 외부 습도가 리튬브로마이드 수용액과 결합하여 약 50%로 감소되어 약 30%의 제습량을 보였으며, 이는 시설 내 제습 시스템의 적용에 적합한 물질로 판단된다. 냉각코일과 리튬브로마이드 수용액을 동시에 적용한 실험에서 약 9K의 온도 강하, 15%의 제습량을 나타냈으며, 리튬브로마이드 수용액이 수증기를 흡수하는 과정에서 반응열이 발생하는 것을 확인하였다. 또한, 시뮬레이션을 통해 냉각 실험 결과와 대비 비교 한 결과 약 299.7K의 내부 온도를 보여 일치하는 것을 확인하였다. 수분의 제습과정을 거치면서 농도가 낮아진 리튬브로 마이드 수용액(희용액)은 수집탱크로 모아 재생부로 이송되어 가열, 수분을 증발시켜 농용액으로 전환된 후 열 교환을 거쳐 냉각되어 다시 제습시스템으로 공급되는 시스템을 적용하면 일정량의 리튬브로마이드 수용액만으로 온실 제습을 할 수 있을 것으로 판단된다. 본 실험을 통해 냉각 및 제습이 동시에 가능하다는 것을 확인하였으며, 리튬브로마이드 수용액을 활용하여 실제 온실에 적용된다면 기존 온실에서 사용하고 있는 냉방 및 제습 방법에 비해 에너지 절감을 통한 경제적 효과를 얻을 수 있을 것으로 판단된다. 향후, 제습 부분은 시뮬레이션을 통한 분석 및 실험결과와 대비 검증이 요구되고, Lab scale의 제습 시스템에 서 Farm scale의 온실 규모로 확장하여, 추가 변수에 대한 제습 및 냉각 연구가 수행되어야 할 것이다.
        4,000원
        125.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This research is to investigate the cooling performance analysis of the heat sinks for LED light with four different fin types and two different fin numbers (16EA and 64EA) of heat sinks. Temperature distributions of fins over the flow domain are numerically calculated for the optimum design of heat sink fin types with uniform initial temperature of the bottom of the fins. According to the calculations of convective heat transfer coefficient between fin and atmosphere in the flow domain, S-curve fin type of heat sinks with 64EA of fins reveals the highest cooling performance of the heat sink fin types in the present cooling heat sink model.
        4,000원
        126.
        2014.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This research is to investigate the performance analysis of cooling fan of the IT and electronic device with two different blade types and three different blade numbers of the cooling fan. Velocity, and temperature distributions of fluid over the flow domain of the flow channel are numerically calculated for the optimum design of flow channel with uniform inlet velocity. According to the calculations of convective heat transfer coefficient between blade and atmosphere in the flow domain, case 2 with 6 blases type shows highest performance of the cooling fan shapes in the present cooling fan model considering manufacturing process and cost
        4,000원
        127.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        Herein, we describe the effect of the cooling-off condition of a solution-processed 6,13-bis(triisopropylsilylethynyl)-pentacene (TIPS-pentacene) film on its molecular distribution and the resultant electrical properties. Since the solvent in a TIPS-pentacene droplet gradually evaporates from the rim to the center exhibiting a radial form of solute, for a quenched case, domains of the TIPS-pentacene film are aboriginally spread showing original features of radial shape due to suppressed molecular rearrangement during the momentary cooling period. For the slowly cooled case, however, TIPS-pentacene molecules are randomly rearranged during the long cooling period. As a result, in the lopsided electrodes structure proposed in this work, the charge transport generates more effectively under the case for radial distribution induced by the quenching technique. It was found that the molecular redistribution during the cooling-period plays an important role on the magnitude of the mobility in a solution-processed organic transistor. This work provides at least a scientific basis between the molecular distribution and electrical properties in solution-processed organic devices.
        4,000원
        128.
        2014.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        기상청에서 제공하는 전체 기상자료와 평년값 자료 및 태양에너지학회에서 제공하는 표준기상데이터를 이용하여 위험률별 난방설계용 외기온과 상대습도, 냉방설계용 건구온도, 습구온도 및 일사량 자료를 분석하였다. 표준 기상데이터는 평균에 가장 가까운 대표성을 갖는 1개년의 데이터로 가공 처리한 매시간별 기상자료이고, 평년 값 자료는 30년(1981~2010년) 평균 일별 기상자료이며, 전체 기상자료는 평년값과 동일기간의 매시간별 기상자료이다. 일부 분석방법은 평년값 자료를 이용하는 경우도 있지만 대부분 매시간별 기상자료가 필요하고 대표성을 갖기 위해서는 표준기상데이터를 이용하는 것이 가장 적합하다. 그러나 현재 표준기상데이터는 서울과 6대 광역시 등 7개 지역만 제공되고 있기 때문에 전국을 커버 할 수 있는 지역별 온실 환경설계용 기상자료의 구축에는 전체 기상자료를 이용할 수밖에 없다. 따라서 본 연구에서는 표준기상데이터가 제공되고 있는 7개 지역을 대상으로 전체 기상자료 및 평년값 자료를 이용한 방법으로 분석하여 표준기상데이터로 구한 값과 비교 검토하였다. 위험률별 설계 기상자료는 전체 기상자료를 이용하여 구한 평균값이 표준기상데이터로 구한 결과와 잘 일치하였다. 따라서 표준기상데이터가 없는 지역의 위험률별 설계용 기상자료는 전체 기상자료를 이용하여 구하고, 전체자료 기간의 평균값을 온실의 환경설계 기준으로 사용하며, 최대값과 최소값을 제공함으로써 참고자료로 활용할 수 있도록 하는 것이 합리적인 방법으로 판단된다. 최근의 기후변화 문제로 냉난방 설계기온의 지 속적인 변화가 예상되므로 이에 대응하기 위해서는 전문 가들로 구성된 온실설계위원회와 같은 기구의 설치가 절실히 요청된다. 위원회에서는 자료기간 및 분석방법에 대한 기준을 설정하고, 최소한 10년 간격의 정기적인 검토를 통하여 기상자료를 분석하고 온실설계기준 및 가이드라인을 제공할 필요가 있다.
        4,000원
        129.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The Laplace Transform solution is used as a mathematical model to analyse the thermal performance of the building constructed using different wall materials. The solution obtained from Laplace Transform is an analytical solution of an one dimensional, linear, partial differential equation for wall temperature profiles and room air temperatures. The main purpose of the study is showing the detail of obtaining solution process of the Laplace Transform. This study is conducted using weather data from two different locations in Korea: Seoul, Busan for both winter and summer conditions. A comparison is made for the cases of an onoff controller and a proportional controller. The weather data are processed to yield hourly average monthly values. Energy consumption load is well calculated from the solution. The result shows that there is an effect of mass on the thermal performance of heavily constructed house in mild weather conditions such as Busan. Building using proportional control experience a higher comfort level in a comparison of building using on-off control.
        4,000원
        132.
        2014.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This experiment evaluated the interaction effect of extreme heat diet(EHD), inverse lighting, and cool water on the growth performance of broiler chickens under extreme heat stress. There were 4 experimental groups (T1: EHD 1, 10:00-19:00 dark, 19:00-10:00 light, cold water 9℃; T2: EHD 2, 10:00-19:00 dark, 19:00-10:00 light, cold water 9℃; T3: EHD 1, 09:00-18:00 dark, 18:00-09:00 light, cold water 14℃; T4: EHD 2, 09:00-18:00 dark, 18:00-09:00 light, cold water 14℃), each group composed of 25 broilers and the experiment was repeated 3 times. EHD 1 contained soybean oil, molasses, methionine and lysine. EHD 2 contained all nutrients of EHD 1 and vitamin C additionally. As a result, T1 and T2 displayed higher body weight increase and diet intake compared to T3 and T4 (p<0.05). The weights of their liver and gizzard were similar but the weights of the thymus and bursa F were higher for T1 and T2 compared to that of T3 and T4 (p<0.05). It was observed that T1 and T2 displayed higher concentrations of blood triglyceride, total cholesterol, HDL-C and blood sugar compared to that of T3 and T4 but LDL-C level was higher for T3 and T4 compared to that of T1 and T2 (p<0.05). T1 and T2 displayed higher levels of immunity substances such as IgG, IgA and IgM compared to T3 and T4 but the blood level of corticosterone displayed to be lower for T1 and T2 compared to T3 and T4 (p<0.05). The T1 and T2 contained a higher amount of fecal lactobacillus compared to that of T3 and T4 but the T3 and T4 contained a higher amount of fecal E. coli, total aerobic bacteria, coliform bacteria compared o that of T1 and T2 (p<0.05). T1 and T2 displayed higher concentrations of cecal acetic acid, ropionic acid and total short chain fatty acids compared to T3 and T4 but T3 and T4 displayed igher concentrations of butyric acid, isobutyric acid, valeric acid and isovaleric acid compared to T1 and T2 (p<0.05). These results have been observed that broiler chickens exposed to extreme eat stress with feeding EHD, inverse lighting and cold water would improve blood lipid, and elevate the production of immunity substance, beneficial microorganisms, and short chain fatty acids. This provision would also reduce the blood sugar consumption rate as energy sources and these effects will improve the growth performance of the broilers exposed to extreme heat.
        4,500원
        133.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 실험은 고온기 근권냉방이 파프리카의 배지온도 하강과 파프리카의 생리적 반응에 미치는 영향을 알아보고자 7월 16일부터 10월 15일까지 코이어 배지에서 재배 하였다. 냉방방식은 공기순환 덕트(지름 12cm, 미세구멍 (0.1mm)으로 찬 공기(7월~8월; 20 ± 2oC, 9월; 23 ± 2oC) 를 야간시간(오후 5시~오전 3시) 공급하였다. 고온기(7월 23일부터 8월 31일) 중 파프리카 배지의 일평균 온도가 냉방처리구는 24.7oC, 대조구는 28.2oC로, 냉방처리구에서 대조구보다 3.0~5.6oC 배지온도가 낮아 졌다. 하루 중 맑은 날(650~700W · m−2) 주간(오전 5시~ 오후 8시)/야간(오후8시~오전5시) 냉방처리구 배지 온도는 대조구보다 1.7oC/3.3oC 낮아졌다. 오후 6시에서 8시까지 초저녁 배지온도 하강속도가 냉방처리구에서는 평균 0.5oC/h, 대조구는 0oC/h였다. 배지 상부와 하부 간의 대조구 대비 냉방처리구의 온도차도 각각 1.3oC, 0.6oC 였다. 냉방처리는 고온(28~32oC) 배지 온도 노출율을 대조구 대비 32.5% 감소시켰다. 냉방처리구의 파프리카 광합성, 증산율 및 수분포텐셜은 대조구보다 높았다. 첫 개화시기도 대조구보다 4일 앞당겨지고, 착과수도 증가하였다. 냉방처리구의 엽장은 짧아졌으나, 초장, 경경, 분지수, 엽폭 등은 차이가 없었다. 야간 근권냉방으로 배지 온도가 3.0~5.6oC를 낮추었으나, 고온기 온실 온도가 고온에서는 파프리카 착과가 지연되므로, 지상부 온도 하강 방법을 병행하면 파프리카 생육과 착과에 효과적이라 판단된다.
        4,000원
        134.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The purpose of this study is to present a case study of six sigma quality improvement practice in cooling fan motor(CFM) manufacturing processes. In this study, the CFM manufacturing process of automobile parts not relevant to the target process rate of the process point of view, in order to reduce the system to solve the problem of localized resolution procedures of six sigma DMAIC methodology was applied to study. In conclusion , this study 's field D in order to improve the initial rate of inadequate quality management best practices by applying the method of Six Sigma quality CFM failure through stabilization schemes were proposed cost reduction .To be CFM product to satisfy customers based on continuous monitoring of the effective field of claims quality management system is required.
        4,000원
        135.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 대학서비스에 대한 외식․조리전공 학습자인식 요인이 만족도에 미치는 영향에 관한 연구로 선행연구에서 주로 연구한 서비스품질의 성과와 결과의 질에 초점 두고 있 고, 실질적인 대학서비스의 수준을 향상시키고, 학생의 학습 만족을 이끌어 내기 위한 대학서비스 속성에 대한 연구는 미흡한 수준이다. 이에 본 연구는 대학서비스 중요도와 만족도 를 측정하기 위해 각각의 속성을 비교 분석하는 중요도-만족 도 분석(IPA: Importance-Performance Analysis) 기법을 활용하 여 중요도와 만족도 수준 사이에 존재하는 차이를 파악하고, 대학서비스 속성의 우선순위 항목 등을 측정하고, 향후 학생 들에게 질 높은 서비스를 제공할 수 있고, 경쟁력 있는 외 식․조리전공 대학을 만드는데 전략적 근거를 수립하기 위한 방안을 제시하고자 실증분석을 하였다. 연구결과, 요인분석을 통해 5개의 요인이 추출되었다. 대 학서비스 속성에서 교수의 전공 지식 정도(3.95), 교수의 강 의에 대한 열정(3.91), 실습실의 최신 시설(3.81), 교수님들의 질 높은 교육을 위한 노력(3.80) 순으로 28개 문항에서 3.8점 이상의 높은 점수를 보였다. 그러나 중요도-만족도 평균의 차 이를 살펴본 결과, 28개 항목 모두가 (+)의 값을 보임으로써 대학서비스 속성별 중요도가 만족도보다 높은 것으로 나타 났다. 즉, 대학서비스 속성에 대한 중요도와 만족도의 불일치 가 크게 존재하고 있음을 나타내고 있다. 그 차이 값을 분석 한 결과, 대학서비스 중요속성에 대한 총 평균값은 3.50이었 고, 실행 후 만족도에 대한 평균값은 2.91로 유의한 차이를 나타났다(p<0.001). 본 연구 결과에 따른 시사점은 첫째, 대학 서비스 중요속성에 비해 만족도속성이 미치지 못하여 통계 적으로 유의하게 불일치됨이 나타나, 대학서비스 속성에 대 한 중요성 제고와 체계적인 관리가 필요하다. 둘째, 중요도가 낮은 서비스에 대해서는 과감하게 투자의 방향을 전환시켜 중요도에 비해 만족도가 낮은 속성을 집중관리가 필요하다. 동시에 현재 지속적인 유지를 필요로 하는 서비스라도 지속 적인 피드백 과정을 통해 학생의 욕구를 파악하고, 적절한 서 비스를 제공하여야 한다. 셋째, 대학서비스 중요도 수준만큼 만족도 수준 역시 높아야 학생만족에 긍정적인 영향을 미친 다고 할 수 있으며, 만족도가 중요도에 미치지 못할 때는 학 생 불만족에 영향을 미칠 수 있다는 점을 본 결과는 시사해 준다. 따라서 대학서비스 관계자들은 IPA 분석을 통해 도출된 결과를 바탕으로 대학서비스 속성 인식을 통한 효율적인 학 생 관리와 체계적인 시스템 개발을 통한 수준 높은 서비스를 제공하여야 한다. 본 연구의 한계점과 이를 극복하기 위한 향후 연구의 방향 은 첫째, 심층 분석을 위한 체계적인 조사도구 개발, 설문지 의견조사와 병행하여 FGI(Focus group interview)를 통해 보다 신뢰할 수 있는 결과를 도출할 필요가 있다. 둘째, 대학서비 스 관계자를 대상으로 한 조사 및 계량적 분석으로 다루기 어려운 부분을 심층적으로 다루기 위한 질적 분석의 보완 등 이 적용되어야 할 것으로 본다. 셋째, 대학 재학생들에 대한 만족도를 증진시키기 위한 서비스 속성, 가치, 행동, 특성을 고려한 지속적인 연구가 요구된다.
        4,000원
        136.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        A three dimensional numerical analysis was performed to study the cooling performance of xEV battery module depending on cooling fluid inlet position. Depending on the inlet position from the top, case 1 (top inlet), case 2 (middle inlet), and case 3 (bottom inlet) are selected. For the case 1, the temperature of the battery near inlet was higher than that of the battery near outlet. For the case 2 and 3 the temperature of the battery near inlet was lower than that of the battery near outlet. From the analysis result, the cooling performance is higher in the order of case 2, case 3, and case 1.
        4,000원
        137.
        2013.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        외부공기 유입방식에 따른 느타리버섯의 생육특성을 조사하기 위하여 3가지 처리구를 두어 실험한 결과 모든 처리구에서 재배기간 중 온도편차가 발생하였고, 처리구 모두 1, 2, 8월에 가장 높았으며, T2(열교환기)와 T3(기밀실)에서 T1(외부공기 직접유입) 보다 온도편차가 작은 경향이었다. 재배기간 중 냉방시간은 T1(외부공기 직접유입)은 1,090.3시간, T2(열교환기)는 661.1시간, T3(기밀실)은 865.0시간이었고,평균 냉방절감율은 T1(외부공기 직접유입) 대비 T2(열교환기)는 21%, T3(기밀실)은 11%이었다. 재배기간 동안 난방기의 년중 가동시간은 T1(외부공기 직접유입)은 1,506.9시간, T2(열교환기)는 875.6시간,T3(기밀실)은 1,054.2시간으로 T2의 가동시간이 가장 작았고, 년중 평균 난방절감율은 T1(외부공기 직접유입) 대비 T2(열교환기)는 22%, T3(기밀실)은16%이었다. 외부공기 유입방식에 따른 냉방정도(CD-H)는 T1(외부공기 직접유입)>T3(기밀실)>T2(열교환기)의 순이었고, 난방정도(HD-H)도 냉방정도(CD-H)의 경우와 동일하였다. 수량은 T2(열교환기)와 T3(기밀실)에서 T1(외부공기 직접유입) 보다 4,9, 10월을 제외한 전 기간에서 높았다.이와 같은 결과로 시설재배사에서 느타리버섯 병재배시 열교환기 또는 기밀실을 설치하여 재배할 경우에너지를 절감할 수 있고, 수량 및 고품질의 느타리버섯을 수확할 수 있어 농가소득증대에 기여할 것으로 판단되었다.
        4,000원
        138.
        2013.10 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This analytical work was performed to reveal the effect of inlet geometry of battery pack on the temperature distributions and flow stream line for a electric vehicle. To achieve this, standard k-ε model with wall function was applied and the working conditions of battery pack under different air flow rate and inlet area according to the geometry were estimated. It was revealed that as inlet area was smaller, the flow velocity was faster, and it can't cover the whole area of battery module. In case of two inlet case, the cooling efficiency of air flow is less than that of one inlet case because of low flow rate.
        4,000원
        139.
        2013.09 KCI 등재 SCOPUS 구독 인증기관 무료, 개인회원 유료
        This study investigated the continuous cooling transformation, microstructure, and mechanical properties of highstrength low-alloy steels containing B and Cu. Continuous cooling transformation diagrams under non-deformed and deformed conditions were constructed by means of dilatometry, metallographic methods, and hardness data. Based on the continuous cooling transformation behaviors, six kinds of steel specimens with different B and Cu contents were fabricated by a thermomechanical control process comprising controlled rolling and accelerated cooling. Then, tensile and Charpy impact tests were conducted to examine the correlation of the microstructure with mechanical properties. Deformation in the austenite region promoted the formation of quasi-polygonal ferrite and granular bainite with a significant increase in transformation start temperatures. The mechanical test results indicate that the B-added steel specimens had higher strength and lower upper-shelf energy than the B-free steel specimens without deterioration in low-temperature toughness because their microstructures were mostly composed of lower bainite and lath martensite with a small amount of degenerate upper bainite. On the other hand, the increase of Cu content from 0.5 wt.% to 1.5 wt.% noticeably increased yield and tensile strengths by 100 MPa without loss of ductility, which may be attributed to the enhanced solid solution hardening and precipitation hardening resulting from veryfine Cu precipitates formed during accelerated cooling.
        4,000원
        140.
        2013.09 구독 인증기관 무료, 개인회원 유료
        As the balcony expansion of residential building was legalized, the expansion generation is tend to increased continuously of existing residential building or condominium complex. But balcony is the service area. So, it is worried about defect occurrence of extension construction because thermal insulation effect is insufficient to balcony installed an aluminum sash. Therefore, it is desired the method to minimize the damage of performance improvement of the windows which has an influence directly on the performance defect. See-through a-si is effective to reduce the cooling loads and sunlight, to produce the electricity by installing a-si at the wall and windows of residential building. This paper has predicted producing electricity and have analyzed heating/cooling load based on balcony expansion and building-integrated PV installation in residential building.
        4,000원