        141.
        2016.04 서비스 종료(열람 제한)
        The four buckling resistance steel dampers were tested under cyclic lateral load to investigate the relationship of lateral load and displacement. The main variables are the existence of cover plate for preventing from buckling of out-of-plane and thickness of sim plate with 3.2 mm, 4.5 mm and 7.0 mm. The test showed that steel damper with cover plate had the wider area of its hysteresis loop than that of without.
        142.
        2016.04 서비스 종료(열람 제한)
        The goal of this study is to investigate the effectiveness of the use of multi constructional material in unit module plate of steel grid structure and provide engineers and designers an appropriate view point of multi-material topology optimization when making decision and information in design. The material distribution is implemented with the use of 3 materials in a given plate under prescribed loading and boundary conditions. Topology changes through automatic distribution of multi materials are presented during optimization procedures showing that there could be selective structural design possibility when using multi materials. The cross sections, stiffness and cost of material combination are useful information for engineers and designers in making design decision.
        143.
        2016.01 KCI 등재 서비스 종료(열람 제한)
        본 논문에서는 UHPC 바닥판과 강재 거더를 이용하여 합성보를 구성할 때, UHPC 바닥판의 높은 강도와 강성으로 인하여 합성보 구성 시에 강재 거더의 상부 플랜지를 없앤 역T형 거더를 적용하고자 하였다. 그러나 현재까지 강재 복부에 설치되는 전단연결재에 대한 거동, 역T형 강거더 합성보의 휨거동 특성 등은 실험 및 이론적으로 평가된 적이 거의 없는 실정이다. 이를 위하여 UHPC 압축강도, 전단연결재 간격 및 바닥판 두께 등을 변수로 하는 역T형 거더와 UHPC바닥판 합성보 16개의 휨거동 실험결과를 근간으로 하여 실험결과와 UHPC의 인장연화 거동을 고려한 재료모델 해석결과를 비교하였다. 역해석에 의한 인장연화곡선에서 UHPC의 인장강도는 6.57 MPa(120MPa의 경우) 및 9.57 MPa(150MPa의 경우)를 나타내고 있으며, 전단연결재 간격이 좁을수록 실험결과와 해석결과가 명확하게 근접하는 겻으로 나타났으며, 바닥 판 두께가 두꺼우며 UHPC 압축강도가 작을수록 동일한 경향이나, 이 영향은 다소 작은 것으로 나타났다. 따라서 실험결과와 해석결과를 종합 적으로 비교하면, UHPC 합성보의 실험결과와 해석결과는 비교적 잘 일치하고 있으므로 재료 실험으로부터 산정된 인장연화곡선은 UHPC의 실제 거동을 합리적으로 반영한다고 판단된다.
        144.
        2015.10 서비스 종료(열람 제한)
        For a efficient maintenance it is necessary to inspect SOC infrastructure using the performance-based evaluation method throughout quantitative measurement. In this study durability evaluation factors of steel structural member are proposed in order to develop performance-based evaluation method of SOC infrastructure.
        145.
        2015.04 서비스 종료(열람 제한)
        Steel structure such as steel bridges are severely affected by the corrosion, and thus has to be maintained by periodic inspection and repetitive painting. In this study, existing empirical models for the degradation of coating are reviewed which is used for evaluation of corrosion, and in addition applied to definition of the state inspection criteria and condition rating by further research.
        146.
        2015.04 서비스 종료(열람 제한)
        Many industries put emphasis on Environment-Friendliness as environmental problems are on the rise all over the world. Among themselves the Modular Bridge research is going on. Also performing cross-section optimization and duration reducing, this research aims at developing the modular bridge with Environment-Friendliness and economic feasibility. However, The difficulty lies in verifying environmental effectiveness because there is no field applications of the modular bridge until now. Therefore, this thesis is 40m bending steel girder modular bridge CO2 emission quantification per work type and materials according to each form to verify environmental effectiveness of the modular bridge.
        147.
        2015.03 KCI 등재 서비스 종료(열람 제한)
        For the safe design of steel-concrete composite structure, usable yield strength of steels are limited in most of design standard. However, this limitation sometimes cause the uneconomical design for some kind of members such as slender columns which was affected by elastic buckling load. For the economical design for slender columns, parametric study of RCFT (Rectangular CFT) with high-strength steel is conducted, especially investigating the limitation of yield strength of high-strength steels. Using ABAQUS, finite element analysis program, the finite element model was constructed and calibrated with experimental study for RCFT with high strength steel which have yield strength up to 680MPa. Investigated design parameters are yield strength of steel, compressive strength of concrete, steel thickness and slenderness ratio. The effect of desgn parameters were compared with design standard, KBC-09. From the parametric study with 54 models and previous test specimens, RCFT can be safely design with higher yield strength of steels than currently limited by KBC for large range of slenderness ratio.
        148.
        2015.02 서비스 종료(열람 제한)
        모듈러 주택은 공장에서 생산되어 현장에서 조립하는 형태로서, 공기 단축, 품질 향상, 비용 절감의 다양한 이점이 있으나, 내화기술 미비 등의 원인으로 국내에서는 아직까지 활성화되지 못하고 있는 상황이다. 내화기술의 경우 국내에서는 모듈러 주택에 적합하도록 개발된 내화구조 기술은 현재까지 부족한 실정이다. 본 연구는 모듈러 주택용 강재의 내화성능 향상을 위한 건식 내화피복 기술 개발을 위한 초기 단계 연구로서 제한된 시험체로 성능평가 및 기술 개발 가능성을 타진하였다. 현재 국내에서 모듈러 주택용 내화기술이 미비하고 내화도료 이외에 별도의 대안이 없는 상황에서, 모듈러 주택 특성을 저해하지 않는 범위에서 경제적이고 제작이 용이한 건식 내화피복 기술은 향후 지속적인 연구를 통하여 최적의 성능조합과 공법 개발이 필요할 것으로 사료된다. 본 연구에서는 성능 향상 인자 중 최소한의 변수를 고려하여 내화성능을 검토하였다. 건식 내화피복 기술은 구성재료의 다양한 조합에 따라 여러 가지 구조가 제시 가능하며, 본 연구에서 제시한 단열재와 방화석고보드 조합으로 그라스울을 사용한 구조의 경우 53분의 내화성능을 확인하였으며, 미네랄울을 사용한 시험체에서 최대 71분의 내화성능을 확보하였으며, 모듈러 주택용 강재의 내화피복기술로 제시한 대안중 미네랄울과 방화석고보드 구조에서 미네랄울의 경우 단열재의 밀도 보다는 최소 75mm이상의 충전 두께를 확보하는 것이 유리할 것으로 사료되며, 건식 내화피복기술 중 방화석고보드의 성능에 따른 초기 30분까지의 초기 온도 상승 억제 구간의 범위를 확대하기 위해서는 최소한 15mm 이상의 방화석고보들 사용하는 것이 유리한 것으로 고찰되었다.
        149.
        2014.10 서비스 종료(열람 제한)
        To develop the external strengthening method which are considered metallic damper in rocking wall system, basic behavior test is conducted on straight strut type metallic damper. Based on test results, it was found that the motion of developed rocking wall system can change properly from rotate behavior to shear behavior.
        150.
        2014.10 서비스 종료(열람 제한)
        The high-strength concrete slab confined by steel members, the possibility of thermal crack due to heat of hydration is high. These thermal cracks, it reduces the serviceability, safety and service life valuation of the structure, it is necessary to review.
        151.
        2014.10 서비스 종료(열람 제한)
        This paper deals with the recent development of GFRP bars by material hybridization (i.e., “hybrid GFRP bars”). This development attempts to improve the low elastic modulus of GFRP bars to be used for reinforced concrete (RC) structures, especially they were built in a corrosive environment (e.g., waterfront structures). The purpose of material hybridization in this study is to increase the elastic modulus of GFRP bar. Steel wires were inserted to GFRP and dispersed over the cross-section. E-glass fibers and unsaturated polyester resins were pultruded. Several types of the hybrid GFRP bars were tested to evaluate the tensile strength. Mechanical behaviour of hybrid GFRP bars was examined as a function two factors: 1) a ratio of steel to GFRP; 2) a diameter of steel wire. The experimental results showed that the elastic modulus of the hybrid GFRP bar was improved by up to 171% by material hybridization. To ensure the long-term durability of the hybrid GFRP bars in waterfront structure applications, the individual and combined effects of environmental conditions on the hybrid GFRP bar itself as well as on the interface between bar and concrete should be also accessed.
        153.
        2014.07 KCI 등재 서비스 종료(열람 제한)
        합리적인 온도 설계하중을 연구하기 위하여, 실제 크기의 콘크리트 슬래브가 없는 강상형 거더 교량 시험체를 제작하였다. 높이에 따라 부착된 18개의 온도 게이지에서 5개월 동안 온도 데이터를 측정하였다. 강상형 거더 교량 시험체의 상단과 하단 사이의 온도 차가 계산되고, 온도 구배 모형이 확률 방법으로 제안되었다. 본 연구에서 제시된 모형은 유로 코드에 의해 제안 된 모델과 비교했을 때 약 97%의 상관관계를 보인다. 따라서, 본 연구의 결과로 제안 된 온도 구배 모델은 온도 설계 하중 계산시 기초 자료로 활용 될 수 있다.
        154.
        2014.04 서비스 종료(열람 제한)
        Fatigue crack can be a controlling factor in the life of some welding components, such as vertical and horizontal stiffener. In this study, FE analysis was carried out to examine the three-dimensional fatigue crack penetration of gusset welded joint using the finite element analysis program FEMAP and FRANC3D. Three-dimensional fatigue crack penetration analysis result was compared with two dimensional fatigue crack penetration analysis result. From the FE analysis results, stress intensity factor(SIF) and crack propagation cycles were evaluated.
        155.
        2014.04 서비스 종료(열람 제한)
        In this paper, the dry solution for restraining the buckling failure of steel brace with the semicircle springs is presented. Finite element analysis shows that the effects of restraining the bucking of brace can be achieved if the structure of semicircle springs is designed appropriately.
        156.
        2014.01 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 불특정 분포하중에 대한 다경간 연속 보 구조물의 변형률 분포를 추정하는 기법을 제시하였다. 본 추정 기법은 해석적 방법이 아닌 계측한 변형률 데이터로부터 최소제곱법을 이용한 커브 피팅을 통해 변형률 분포를 추정하였다. 제시한 다경간 보 연속 구조물의 변형률 추정 기법은 멀티플렉싱이 가능한 FBG센서를 이용하여 다경간 연속 강재 보 정적 가력 실험을 통해 검증하였다. 실험을 통해서 분포 하중과 집중하중에 의한 변형률 분포의 추정 정확성 및 변형률 추정에 사용되는 계측점 수에 따른 추정 오차에 대한 검토를 수행하였다. 5.89 (하중 step1), 6.26% (하중 step2) 오차로 최대 변형률 지점에서의 변형률을 추정할 수 있었다. 추정을 위한 변형률 계측 센서 수를 감소시킨 경우 오차가 증가 (0.26~0.37%)하는 것 또한, 확인할 수 있었다. 회귀분석적 기법을 통해 다경간 보의 변형률 분포를추정함으로써 특정 형상의 분포 하중에 대해서만 적용이 가능한 해석적 변형률 추정 기법의 한계를 넘어 불특정 분포 하중에 대한 변형률분포 추정이 가능해졌고 추정 변형률 분포를 통해 최대변형률 발생 위치까지 확인할 수 있게 되었다.
        157.
        2014.01 KCI 등재 서비스 종료(열람 제한)
        본 연구에서는 강주탑 기부와 기초콘크리트 연결 구조에 대해서 국내에서 특수교량의 강주탑 기부 설계에 보편적으로 적용하고 있는 明石海峽大橋 시방기준과 비선형 FEM 해석결과를 비교하였다. 明石海峽大橋 시방기준은 1970년도에 만들어진 일본 기준으로 주탑 기부와PS 강봉 및 기초콘크리트를 스프링으로 선형 모델링하여 설계하는 방법으로서 43년이 지난 지금까지도 간편성을 이유로 이 기준을 적용하고 있다. 그러나 비선형 FEM 해석결과의 비교를 통해 특수 장대교의 강주탑 기부의 해석 및 설계에 이 기준을 적용하는 것은 여러 가지 문제점이 있음을 알 수 있었으며, 풍하중, 지진하중에 주요하게 저항하면서도 다양한 부재들로 복잡하게 연결된 강주탑 기부에 대해서는한계상태설계법으로 발전하려는 현 시대에 맞추어 실제 거동을 반영하는 비선형 FEM해석을 적용해야 할 것이다.
        158.
        2013.10 서비스 종료(열람 제한)
        To evaluate the displacement dependency of metallic damper which has straight type steel strut, cyclic tests are conducted with the target displacement variables on constant velocity. Form this, width to height ratio of strut is 0.079. From the strength and energy dissipation capacity comparison, cyclic test results are short of the static test results. Therefore more detailed design which are considering target structure period and dynamic characteristics is needed.
        159.
        2013.10 서비스 종료(열람 제한)
        In this study, an experimental study to investigate the load transfer behavior of the CFT column to steel beam connection was carried out. The load transfer mechanism and the effect of the load transfer length were examined, and the results were also compared with finite element analysis results. Finally, the results are to be used for the basic reference of the design guideline for the CFT column connection.
        160.
        2013.10 서비스 종료(열람 제한)
        The purpose of this study is to evaluate the corrosion protection properties of Zn/Sn metal spray method according to the contents ratio of Zn and Sn by CASS test. Also, the corrosion protection life of Zn/Sn metal spray method is evaluated by the comparing between the corrosion properties of Zn metalizing method and Zn/Sn metal spray method using CASS test. As a result, it was confirmed that the optimum content ratio of Zn/Sn in metal spray method is 60:40(65:35) (Zn : Sn volume ratio) in aspect of corrosion protection properties and construction properties. Also, it was confirmed that the Zn/Sn metal spray method had more than 3 times of corrosion protection properties cmparing the Zn matalizing method.
        6 7 8 9 10