Many school buildings are vulnerable to earthquakes because they were built before mandatory seismic design was applied. This study uses machine learning to develop an algorithm that rapidly constructs an optimal reinforcement scheme with simple information for non-ductile reinforced concrete school buildings built according to standard design drawings in the 1980s. We utilize a decision tree (DT) model that can conservatively predict the failure type of reinforced concrete columns through machine learning that rapidly determines the failure type of reinforced concrete columns with simple information, and through this, a methodology is developed to construct an optimal reinforcement scheme for the confinement ratio (CR) for ductility enhancement and the stiffness ratio (SR) for stiffness enhancement. By examining the failure types of columns according to changes in confinement ratio and stiffness ratio, we propose a retrofit scheme for school buildings with masonry walls and present the maximum applicable stiffness ratio and the allowable range of stiffness ratio increase for the minimum and maximum values of confinement ratio. This retrofit scheme construction methodology allows for faster construction than existing analysis methods.
최근, 큰 처짐과 다수의 균열을 동반하는 유사연성 거동과 부식에 대한 높은 내구성의 특징을 가진 FRCM(Fabric-Reinforced Cemenetitious Matrix) 복합체에 대한 관심이 증가하고 있다. 철근콘크리트 부재에 대해 다양한 장점을 지닌 FRMC 복합체를 적용할 경우 전단내력의 증대를 예상할 수 있으며, 이를 통해 내진성능이 요 구되는 철근콘크리트 구조물에 효과를 기대할 수 있다. 본 연구에서는 FRCM 복합체가 보강된 철근콘크리트 기둥에 대해 정적 반복가력 실험을 수행하고, 그 거동을 평가 하였다. 철근콘크리트 기둥은 직사각형 형상으로 단면의 크기가 300 × 300 mm이고, 순 높이는 800 mm로 제작되었다. 정적 반복가력 실험은 설정한 가력패턴에 따라 변위제어를 통해 횡 하중을 가력하 였고, 초기 축력은 기둥 용량의 10 %로 적용하였다. 정적 반복가력 실험 결과, 무보강 실험체 대비 약 27.33 %의 증진된 강도를 나타내었으며, 최대 강도 발현 시 층간변위비가 무보강 실험체 대비 약 187.6% 높게 나타냄에 따라 FRCM 복합체가 적용된 철근콘크리트 기둥의 높은 연성 거동을 확인 할 수 있다. 다만, FRCM 복합체를 실제 구조물에 적용하기 위해서는 추가적인 설계인자 개발을 통해 안 정성 및 신뢰성을 확보하는 것이 필수적이라고 판단된다.
본 연구에서는 콘크리트 구조물의 내구성 고도화를 위하여 고속도로용 교각 기둥부에 대하여 내부 식성이 우수한 GFRP 보강근 적용하였으며, 설계적 분석, 축소모형 시험체 제작 및 성능 시험을 통하 여 실용화의 타당성를 검증하였다. 설계적으로 교각의 기둥부는 축방향 주철근을 GFRP 보강근으로 대체하였다. 일반적으로 GFRP는 압축부에 취약한 것으로 알려져 있으며, 국외 기준의 경우는 압축부 에 대하여 GFRP 보강근은 저항력이 없는 것으로 가정하고 있다. 본 연구에서는 탄성 교각에 대하여 기존 철근을 대체할 수 있는 GFRP 보강근의 설계적 방안 제시 및 실물 시험을 통한 성능 검증을 수 행하여 결과를 제시하였다. 본 연구 결과는 고속도로용 탄성 교각 기둥의 내구성 증진을 위한 설계 및 실용화에 있어 가능한 가이드라인을 제시할 것으로 기대된다. 다만, 본 연구에서 다룬 기둥부는 주철 근만을 GFRP 보강근으로 대체한 것으로, 향후 GFRP 나선형 보강근 등의 적용, GFRP의 축하중 분담 률 및 건조수축 크리프 특성, 기둥부의 최소 보강근비 산정 그리고 GFRP 보강근의 압축강도 측정법 등 상세 사항에 대한 추가적인 연구가 필요할 것이다.
The purpose of this study is to experimentally analyze the seismic performance of beam-column specimens with vertical irregular, which were reinforced with RHS (Replaceable steel haunch system). a steel haunch system. To evaluate the seismic performance of the RHS, three specimens were manufactured and subjected to cycle loading tests. Retrofitted specimens have different beam-upper column stiffness ratio as a variable. The stiffness ratio of beam-upper column were considered to be 1.2 and 0.84. As a result of the test, the specimen reinforced with RHS showed improved maximum load and effective stiffness, and energy dissipation capacity compared to the non-retrofitted specimen with same beam-upper column stiffness ratio. The specimen with 0.84 beam-upper column stiffness ratio showed improved performance than the specimen with 12.
The current study investigates the seismic performance of shear-dominant RC columns retrofitted with iron-based shape memory alloy (Fe SMA). Three RC columns with insufficient transverse reinforcement were designed and fabricated for lateral cyclic loading tests. Before testing, two specimens were externally confined with carbon fiber-reinforced polymer (CFRP) sheets and self-prestressed Fe SMA strips. The test results showed that both CFRP and Fe SMA performed well in preventing severe shear failure exhibited by the unretrofitted control specimen. Furthermore, the two retrofitted specimens showed ductile flexural responses up to the drift ratios of ±8%. In terms of damage control, however, the Fe SMA confinement was superior to CFRP confinement in that the spalling of concrete was much less and that the rupture of confinement did not occur.
최근 국내에서 연간 지진 발생 횟수가 꾸준히 증가함에 따라 공공시설물에 대한 내진 보강의 필요성이 더욱 대두되고 있다. 이 연구 에서는 사각 단면을 가진 철근콘크리트 기둥에서 강봉보강의 유무에 따른 내진 성능 개선 효과를 분석하기 위해 비선형 유한요소해 석을 수행하였으며, 검증을 위해 구조실험결과와 비교하였다. 분석 결과, 이 연구에서 수행한 유한요소해석이 실제 강봉보강공법을 적용한 철근콘크리트 기둥의 구조 거동을 합리적으로 잘 묘사하는 것으로 나타났다. 또한, 해석 및 실험 모두 강봉보강공법 적용으로 인해 파괴모드가 취성파괴에서 연성파괴로 전환되었으며, 강도와 연성도 모두 증가하는 것으로 나타났다. 따라서, 강봉보강공법 적 용을 통해 기존 철근콘크리트 기둥의 내진 성능을 효과적으로 증진시킬 수 있는 것으로 판단된다. 이 연구의 주요 결과는 향후 설계 방 안 마련 등 관련 연구에 유용할 것으로 기대된다.
현장에 적용하는 콘크리트 강도가 증가함에 따라 초고성능 콘크리트의 적용 분야가 넓어지고 있다. 초고성능 콘크리 트에는 강섬유를 일반적으로 사용하고 있지만, 이를 대체하기 위해 다양한 섬유를 연구에 적용하고 있다. 대표적으로 슈퍼섬유 라고 알려진 아라미드 섬유가 있다. 본 연구에서는 초고성능 콘크리트의 특성이 구조물 보수보강 및 내진보강에 적용하기에 적 합하다고 판단하여, 슈퍼섬유 중 하나인 파라아리미드 섬유와 조합한 복합섬유를 혼입한 초고성능 콘크리트를 보-기둥 접합부에 내진보강재로 활용하여 특성을 분석하였다. 초고성능 콘크리트의 내진보강 효과를 확인하였으며 내진상세를 적용한 실험체와 유사한 거동을 확인하였다. 초고성능 콘크리트의 높은 강도로 인해 기존 콘크리트가 파괴되는 양상이 나타나 초고성능 콘크리 트의 보수보강 효과를 모두 발휘하지 못하고 있어 추가 연구를 통해 최적의 보강단면을 설정한다면 내진보강재료로 활용할 수 있을 것으로 판단된다.
This study proposed a seismic reinforcement of RC columns with non-seismic details, a fiber reinforcement method of aramid sheets and MLCP (high elasticity aromatic polyester fiber material) with different characteristics, and 4 full-size column specimens and conducted experiments. The results show that a non-seismic specimen (RC-Orig) rapidly lost its load-bearing capacity after reaching the maximum load, and shear failure occurred. The RC column reinforced with three types of aramid did not show an apparent increase in strength compared to the unreinforced specimen but showed a ductile behavior supporting the load while receiving a lateral displacement at least 1.57 to 1.95 times higher than the unreinforced specimen. The fracture mode of the specimen, according to the application of lateral load, also changed from shear to ductile fracture through aramid-based reinforcement. In addition, when examining the energy dissipation ability of the reinforced specimens, a ductile behavior dissipating seismic energy performed 4 times greater and more stably than the existing specimens.
본 논문은 FRP로 보강된 콘크리트 기둥의 압축성능에 관한 연구를 수행하였다. 압축성능을 분석하기 위해서 P-M 상 관도를 다양한 파라미터 연구를 통해서 비교, 분석하였다. FRP로 보강된 콘크리트 기둥의 P-M 상관도를 AASHTO LRFD(2018) 설계 기준과 Zadeh and Nanni(2013) 연구의 두 가지 모델로 비교, 분석하여 압축성능을 분석하였다. 균형 파괴점(Balance Point)의 위치는 철근으로 보강된 경우는 압축측에 위치하는 반면에 FRP로 보강된 기둥의 경우는 보통 인장측(아래쪽)에 위치하지만 압 축측(위쪽)에도 위치할 수도 있다. FRP로 보강된 콘크리트의 경우의 파괴형태는 콘크리트의 압축파괴로 유도하는 것이 강도 측 면이나 급작스러운 파괴 등의 측면에서 유리하기 때문에 균형 파괴점의 위치가 중요하다. 분석 결과 FRP의 보강비가 커질수록, FRP의 파괴 변형률이 일정하면 파괴 응력과 탄성계수가 커질수록, 파괴 변형률이 커질수록, 콘크리트의 강도가 작을수록 균형 파괴점은 아래쪽으로 내려간다.
Steel brace strengthening is the most popular seismic rehabilitation method for school buildings. This is because the design can be conducted by using relatively easy nonlinear pushover analysis and standard modeling in codes. An issue with steel brace strengthening is that the reinforced building should behave elastically to satisfy performance objectives. For this, the size of steel braces should be highly increased, which results in excessive strengthening cost by force concentration on existing members and foundations due to the considerable stiffness and strength of the steel braces. The main reason may be the brittle failure mode of columns, so this study investigated the relationship between the efficiency of steel brace strengthening and column failure modes. The result showed that the efficiency is highly dependent on the shear capacity ratio of columns and structural analysis methods. School buildings reinforced by steel braces do not need to behave elastically when the shear capacity ratio is low, and pushover analysis is used, which means reducing steel material is possible.
In SRC column, the closed hoops are applied with the same detail of both 135° standard hooks to expect the same performance as hoops of RC columns. This standard detail is actually complicated to construct, thus, two separating rebars are connected in the form of a square shape and welded over the overlapping section. But this is also complicated in construction practice. Therefore, this study describes experimental results regarding cyclic behaviors shown with alternative hoops cramped by the steel clip type-binding device instead of welding and standard specimen. As a result of the experiment, the specimens with alternative hoops of the SRC column showed comparable performance to the specimens with closed hoops. Therefore, it can be evaluated that the alternative hoops applied with the rebar confinement clips in the SRC column can replace the closed hoop.
본 논문에서는 철계형상기억합금(Fe SMA) 스트립으로 능동구속된 콘크리트 기둥의 실험적, 해석적 연구결과를 제시한다. Fe SMA과 탄소섬유보강시트(CFRP)로 각각 구속된 콘크리트 공시체의 압축실험을 통해 형상기억합금 기반 능동구속기법의 효과성을 평가하였다. 실험결과, Fe SMA 스트립으로 구속된 콘크리트 공시체가 낮은 구속력에도 불구하고 CFRP 시트로 구속된 공시체에 비 해 더 우수한 변형능력을 가지는 것으로 밝혀졌다. 실험을 통해 얻은 구속된 콘크리트의 압축거동 결과를 이용해 소성힌지 영역이 각 각 Fe SMA 스트립과 CFRP 시트로 보강된 콘크리트 기둥의 유한요소모델을 구축하였다. 기존 수행된 콘크리트 기둥의 수평반복가력 실험결과를 바탕으로 구축된 기둥 모델을 검증하였고, 각각의 기둥 모델에 대한 수평반복가력 해석을 수행하였다. 해석결과, Fe SMA 스트립으로 보강된 콘크리트 기둥이 CFRP 시트로 보강된 기둥모델에 비해 변형, 에너지 소산능력 향상에 효과적임을 확인하였다.
Unlike the CFT retrofit method, The EPFT retrofit method, which fills the steel tube with engineering plastic, does not require a separate concrete forming work and is a lightweight seismic Retrofit Method. In this study, an prototype model of the EPFT was proposed, and to analyze the seismic performance, an independent specimens and a reinforced concrete column were fabricated to conduct a seismic performance test. As a result of loading test of the independent specimens, the strength was increased compared to the steel tube column without internal filling, and the ductility ratio did not significantly increase due to the falling off of the weld. As a result of loading test of the concrete reinforcement specimen, the strength, ductility ratio, and energy dissipation were increased, and the number of cracks by loading step decreased compared to the non-reinforced specimen.
최근 경주, 포항에 연이은 지진 발생으로 인하여 내진설계에 관심이 높아지고 있다. 다가구주택 필로티기둥은 수직 비정형 시스템으로 상,하부층의 강성 차이로 인하여 지진 발생 시 막대한 피해가 예상되기 때문에 다가구주택 필로티기둥의 내 진보강이 필요하다. 그러나 민간 소유인 다가구주택의 경우 막대한 비용과 시간으로 인하여 보강이 어려운 실정이다. 이에 따 라, 복합섬유패널로 에폭시 접착제 미사용으로 건식시공이 가능한 전단보강공법을 제안하고자 한다. 본 연구에서는 복합섬유패 널 보강 유무에 따른 내진보강공법의 전단내력을 실험을 통하여 검증하였고, 에폭시를 사용하지 않아 일체화 거동을 하지는 않 지만 복합섬유패널의 영향으로 전단내력은 1.46∼1.49배 증가하는 것으로 평가되었다. 따라서 다가구주택 필로티기둥의 내진보 강효과가 있을 것으로 판단된다.
The collapse of reinforced concrete (RC) frame buildings is mainly caused by the failure of columns. To prevent brittle failure of RC column, numerous studies have been conducted on the seismic performance of strengthened RC columns. Concrete jacketing method, which is one of the retrofitting method of RC members, can enhance strength and stiffness of original RC column with enlarged section and provide uniformly distributed lateral load capacity throughout the structure. The experimental studies have been conducted by many researchers to analyze seismic performance of seismic strengthened RC column. However, structures which have plan and vertical irregularities shows torsional behavior, and therefore it causes large deformation on RC column when subjected to seismic load. Thus, test results from concentric cyclic loading can be overestimated comparing to eccentric cyclic test results, In this paper, two kinds of eccentric loading pattern was suggested to analyze structural performance of RC columns, which are strengthened by concrete jacketing method with new details in jacketed section. Based on the results, it is concluded that specimens strengthened with new concrete jacketing method increased 830% of maximum load, 150% of maximum displacement and changed the failure modes of non-strengthened RC columns.
본 연구에서는 기존 비내진설계 콘크리트 기둥의 내진성능 개선을 위해 기둥 면적의 80% 영역을 12K 능직 카본 섬 유(CFRP sheet)와 카본용 에폭시 수지를 사용하여 보강한 후 보강량에 따른 내진성능을 실험적으로 평가하였다. 실험을 위해 실 험실 단위에서의 준실대형 기둥을 제작하였으며, 유압 풀링잭을 이용하여 약 10%만큼의 일정한 축력을 가력한 다음 변위제어를 통해 최대 10%의 변위비만큼 각 변위 사이클당 2회씩 반복 재하하여 가력을 수행하였다. 실험 결과 2겹의 12K CFRP sheet 보 강의 경우 누적에너지소산이 6.6배 증가하였으며, 4겹의 경우 9.6배 증가하였다.
다가구주택 필로티기둥은 전이구조 형식으로 되어 있어 지진하중에 대하여 전단파괴가 발생하기 쉽다. 이에 따라 내 진설계기준은 강화되고 있지만 이전에 지어진 건축물의 경우 내진보강이 필요한 실정이다. 하지만 기존 습식 공법의 경우 시간 적, 경제적 부담이 크기 때문에 내진보강이 잘 이루어지지 않는다. 따라서 모서리앵글과 CN복합섬유패널을 활용하여 DIY 시공 이 가능한 전단보강공법을 제안하고자 하며 본 실험에서 CN복합섬유패널의 전단성능을 평가하고자 한다. 볼트 연단거리 및 앵 글의 재질을 변수로 설정하여 실험한 결과, 볼트 연단거리가 가까울수록 각형띠판 래티스기둥의 전단내력이 증진되는 것을 확 인하였으며 슬리브 볼트는 고장력 볼트에 비하여 현저히 내력이 저하되어 CN복합섬유패널을 평가하기가 어려웠다. 또한, 알루 미늄앵글은 강재앵글에 비하여 내력은 낮지만 연성능력이 좋은 것으로 평가되었고, 강재앵글은 상대적으로 강성이 크기 때문에 CN복합섬유패널에 주는 영향이 미미한 것을 확인하였다. 이를 실용화하기 위해서 구체적으로 앵글의 크기와 볼트 연단거리를 변수로 설정하여 실험을 수행해야 할 것으로 판단된다.