Recently, high-rise residential buildings in Korea have adopted slender shear walls with irregular section shapes, such as T-shape, H-shape, and C-shape. In the seismic design of the slender shear walls, the transverse reinforcement for lateral confinement should be provided in the boundary elements to increase deformation capacity and subsequent ductility. However, in practice, the irregularity of the shear walls is not adequately considered, and the lateral confinement region is calculated for the rectangular wall segments. This study investigated the proper design method for lateral confinement regions using finite element analysis. The lateral confinement region was considered in analysis for two cases: 1) as a typical rectangular wall segment and 2) as an irregular wall. When the irregularity of the walls was considered, the compression zone depth was increased because the vertical reinforcement in the flange was addressed. The effect of lateral confinement design methods on the structural performance of the walls was directly compared under various design parameters, including the length of the flange, concrete compressive strength, vertical rebar layout, axial load ratio, and loading direction. According to the results of the parametric analysis, the peak strength and deformation capacity could be significantly increased when the lateral confinement region was calculated based on irregularly shaped walls, regardless of the design parameters. In addition, the effective compression zone was located within the lateral confinement region. Thus, it is recommended that the lateral confinement region of T-shaped walls is calculated by addressing the irregularity of the walls.
For low-rise piloti-type buildings that suffered significant damage in the Pohang earthquake, the seismic performance of those designed by codes issued before and after the earthquake has been recently revised. This study started with the expectation that many of the requirements presented in the current codes may be excessive, and among them, the spacing of column stirrup could be relaxed. In particular, the recently revised design code of concrete structures for buildings, KDS 41 20 00, suggests that the column stirrup spacing is 1/2 of the minimum cross-sectional size or 200 mm, which is strengthened compared to KBC 2016, but relaxed than the current KDS, 41 17 00, which is 1/4 of the minimum size or 150 mm. As a result of the study, it was found that the target performance level was sufficiently satisfied by following the current standards and that it could be satisfied even if the relaxed spacing was followed. Therefore, the strict column stirrup spacing of KDS 41 17 00 could be relaxed if a wall other than core walls is recommended in the current guideline for the structural design of piloti-type buildings.
In this paper, a dynamic centrifuge model test was conducted on a 24.8-meter-deep excavation consisting of a 20 m sand layer and 4.8 m bedrock, classified as S3 by Korean seismic design code KDS 17 10 00. A braced excavation wall supports the hole. From the results, the mechanism of seismically induced earth pressure was investigated, and their distribution and loading points were analyzed. During earthquake loadings, active seismic earth pressure decreases from the at-rest earth pressure since the backfill laterally expands at the movement of the wall toward the active direction. Yet, the passive seismic earth pressure increases from the at-rest earth pressure since the backfill pushes to the wall and laterally compresses at it, moving toward a passive direction and returning to the initial position. The seismic earth pressure distribution shows a half-diamond distribution in the dense sand and a uniform distribution in loose sand. The loading point of dynamic thrust corresponding with seismic earth pressure is at the center of the soil backfill. The dynamic thrust increased differently depending on the backfill's relative density and input motion type. Still, in general, the dynamic thrust increased rapidly when the maximum horizontal displacement of the wall exceeded 0.05 H%.
본 연구는 수직 벽체형 콘크리트 구조물의 정밀안전진단을 위한 외관조사시 고품질 정밀영상을 자동화된 방식으로 획득하여 균열손상을 탐지하고 시설물의 상태를 평가하기 위하여 개발된 등벽드론 탑재형 균열진단 시스템에 대한 것이다. 본 논문에서는 영상기반 균열진단 시스템을 이용한 정밀영상 획득기술, 자동화된 영상처리 알고리즘을 이용한 데이터 처리 기법을 제시하였으며, 실험적으로 도출된 지상표본거리를 기반으로 영상처리 자동화 알고리즘을 이용하여 생성된 균열모사 시험벽체의 평면전개 이미지 상 균열손상의 위치 정확도를 평가 분석하였다. 평가분석 결과, 가로축 길이 대비 최대 1.1%, 세로축 길이 대 비 최대 1.4%의 오차율을 보이는 것으로 나타났다. 제안된 영상 내 픽셀 좌표와 지상표본거리를 기반으로 균열손상의 위치를 추정하는 기법은 실측 좌표 대비 평균 1.0% 이하의 위치 오차를 가지는 것으로 평가되었다. 최종적으로 영상기반 진단과 긴급 보수와 같은 일반적인 시설물의 유지관리에 요구되는 위치 정확도를 확보하고 있는 것으로 분석되었다.
Structural vibration induced by earthquake hazards is one of the most significant concerns in structure performance-based design. Structural hazards evoked from seismic events must be properly identified to make buildings resilient enough to withstand extreme earthquake loadings. To investigate the effects of combined earthquake-resistant systems, shear walls and five types of dampers are incorporated in nineteen structural models by altering their arrangements. All the building models were developed as per ACI 318-14 and ASCE 7-16. Seismic fragility curves were developed from the incremental dynamic analyses (IDA) performed by using seven sets of ground motions, and eventually, by following FEMA P695 provisions, the collapse margin ratio (CMR) was computed from the collapse curves. It is evident from the results that the seismic performance of the proposed combined shear wall-damper system is significantly better than the models equipped with shear walls only. The scrutinized dual seismic resisting system is expected to be applied practically to ensure a multi-level shield for tall structures in high seismic risk zones.
This study investigated the rocking behavior of unreinforced masonry walls and wall piers under cyclic loading. Based on the benchmark tests, the characteristics of load-deformation relations in masonry walls with rocking failure were captured, focusing on observed deformation modes. The rocking strengths of masonry walls (i.e., peak and residual strengths) were evaluated, and the effects of opening configurations on the masonry wall strength were examined. The deformation capacity of the rocking behavior and the hysteresis shape of the load-deformation relations were also identified. Based on the results, modeling approaches for the rocking behavior of masonry walls were discussed.
The paper introduces an experimental program for the newly developed vertical joints between Precast Concrete (PC) walls to improve their in-plane shear capacity. Compared to the existing vertical joints, two types of vertical joints were developed by increasing the transverse reinforcement ratio and improving frictional force at the joint interface. A total of four specimens including the Reinforced Concrete (RC) wall and PC walls with developed vertical joints were designed and constructed. The constructed specimens were experimentally investigated through monotonic shear tests. The observed damage, load-deformation relationship, strain and strength are investigated and compared with the cases of RC wall specimen. Experimental results indicate that the maximum force and initial stiffness of the PC wall with proposed vertical joints were decreased by comparing with those of RC wall. However, the ultimate displacement increased by up to 217.30% compared to the RC wall specimen. In addition, brittle failure did not occurred and relatively few cracks and damages occurred.
본 논문에서는 전이보 시스템이 지닌 층고 및 공사물량 증가의 단점을 보완할 수 있는 경계보-벽체 시스템의 압축성능을 평가하였 다. 1/2 축소실험체에 대한 압축실험을 수행하고 그 결과를 3차원 비선형 유한요소해석 결과와 비교 및 분석하였다. 실험체 변수로 상 하부벽체의 수평길이 상대비, 하부벽체의 두께, 하부벽체 전단보강근의 상세를 고려하였다. 실험의 최대하중은 하부벽체의 공칭축강 도와 유사하게 나타났으며, 이로부터 상부벽체로부터의 수직 하중이 하부벽체로 원활하게 전달되며, 편심으로 인한 모멘트 중 상당 량을 경계보가 가져감을 알 수 있다. 상하부벽체 수평길이의 상대비가 40%일 경우 50%일 때보다 단면의 기여도가 증가하였으며, 하 부벽체에 면외방향 편심이 존재할 경우 단면의 기여도가 감소하였다. 하부벽체의 전단보강근 간격을 줄이고 크로스 타이를 배근할 경우 초기강성 및 최대하중이 증가하며 국부적인 응력집중이 감소하였다.
현 설계기준에서 제시한 단부횡보강 상세는 시공성과 생산품질이 현저히 떨어지므로 내진성능과 시공성을 확보할 수 있는 RC 구 조벽체의 단부횡보강 상세 개발이 필요하다. 최근 선재 제작기술의 발전으로 다양한 선조립철근의 제작이 가능해지고 있으며 특히 다양한 연속횡보강 철근 상세의 제작이 가능하게 되었다. 본 연구에서는 사각 연속횡보강 선조립철근 단부횡보강 상세를 적용한 RC 구조벽체의 모멘트-곡률 관계에 대한 분석을 진행하였다. 비선형 단면해석에 의하면 사각 연속횡보강의 상세를 적용한 RC 구조벽체 는 사각 연속횡보강 영역의 면적이 증가할수록 내진성능을 확보할 수 있다. 이러한 연구결과에 근거하여 사각 연속횡보강 선조립 철 근의 상세 적용시, 단부횡보강 영역의 면적만큼 사각 연속횡보강 영역의 면적을 확보해야 한다.
In this study, the types of thermal breakers applied to structures to prevent thermal bridges were identified. Condensation prevention performance was evaluated for apartment houses with standard floor structures to which a thermal breaker was applied. In addition, the effect of thermal cross-blocking was compared by calculating the total heat and equivalent U-value through the wall. (1) As a result of the evaluation of anti-condensation performance, when “가” grade insulation was applied, the surface temperature increased by about 1K due to the application of the thermal breaker. The TDR value increased by about 0.06 to 0.07. When "나" grade insulation was applied, the minimum surface temperature increased by about 1K, and the TDR value increased by about 0.05~0.06. (2) As a result of the evaluation of total heat and U-equivalent, it was possible to reduce the total heat by 38.5~44.9% and U-equivalent by 38.5~45.0% for the "가" grade insulation to which the thermal breaker was applied. In addition, the "나" grade insulation to which the thermal breaker was applied can reduce total heat by 38.9 to 43.6%, and reduce the Uequivalent by 38.9 to 43.7%.
최근 경주와 포항에서 발생한 지진피해 사례에서 보듯 조적벽체 및 필로티 구조물의 붕괴 위험이 사회적으로 큰 주목을 받고 있다. 본 연구는 명확한 내진설계지침이 없고 수평하중에 대한 내성이 구조적으로 매우 약하며 재난관리시설 중 지 진붕괴 위험이 높은 조적조 구조물에 대한 보강 설계 및 성능평가를 조사하였다. 기존 선행연구에서 발표된 FRP Plate의 외부 접착시 부착파괴의 문제점을 반영하여 부착력이 개선된 매립형 T-Joint BFRP Plate를 개발하였으며, 시공 시 에폭시 계열의 연성페인트를 활용하여 보강구조물의 연성을 개선하는 방법을 제안하였다. 최종적으로 수행된 정적 및 반복가력 실험을 통하여 보강시험체의 강성 및 에너지 소산능력이 각 1.23과 1.39배 증가함을 확인하였다.
최근 국내 원자력발전소의 격납건물 벽체와 Containment Liner Plate(CLP) 사이에서 다양한 크기의 공극이 발견됨에 따라 원전 격납건물의 보수를 위해 내부 공극의 분포와 크기를 정밀하게 평가할 수 있는 진단기법의 개발이 요구되고 있다. 이에 따라 이 연구에서 는 격납건물 벽체에서의 탄성파 전파거동을 계산하는 2차원 유한요소해석 기법을 제시한다. 격납건물 벽체를 기반으로 해석영역을 구성하고 경계면에서의 반사파를 제거하기 위해 수치적 파동흡수 경계층인 perfectly matched layer를 도입하였다. Galerkin 기반 혼합 유한요소법을 이용해 2차원 유한영역에서 탄성파 파동방정식의 해를 구하여 충격하중에 대한 격납건물 벽체의 변위와 응력을 계산하였다. 제시한 수치적 기법을 이용하여 격납건물 콘크리트 벽체의 CLP 부착 유무와 공동의 위치 및 크기 변화에 따른 탄성파 전파거 동을 살펴보았다. 이 연구의 결과는 원전 격납건물 내부의 공동을 진단하는 탄성파 전체파형 역해석 기법 개발에 활용될 수 있다.
KAERI has planned to carry out a series of dynamic tests using a shaking table and time-history analyses for a channel-type concrete shear wall to investigate its seismic performance because of the recently frequent occurrence of earthquakes in the south-eastern parts of Korea. The overall size of a test specimen is ×× 2500 mm×3500 mm×4500 mm, and it consists of three stories having slabs and walls with thicknesses of 140 mm and 150 mm, respectively. The system identification, FE model updating, and time-history analysis results for a test shear wall are presented herein. By applying the advanced system identification, so-called pLSCF, the improved modal parameters are extracted in the lower modes. Using three FE in-house packages, such as FEMtools, Ruaumoko, and VecTor4, the eigenanalyses are made for an initial FE model, resulting in consistency in eigenvalues. However, they exhibit relatively stiffer behavior, as much as 30 to 50% compared with those extracted from the test in the 1st and 2nd modes. The FE model updating is carried out to consider the 6-dofs spring stiffnesses at the wall base as major parameters by adopting a Bayesian type automatic updating algorithm to minimize the residuals in modal parameters. The updating results indicate that the highest sensitivity is apparent in the vertical translational springs at few locations ranging from 300 to 500% in variation. However, their changes seem to have no physical meaning because of the numerical values. Finally, using the updated FE model, the time-history responses are predicted by Ruaumoko at each floor where accelerometers are located. The accelerograms between test and analysis show an acceptable match in terms of maximum and minimum values. However, the magnitudes and patterns of floor response spectra seem somewhat different because of the slightly different input accelerograms and damping ratios involved.
현재 우리나라에서 설계 및 시공되는 대부분의 철근콘크리트 벽식구조 공동주택은 상부벽체-하부골조 시스템으로 구성되어 있으며 서로 다른 상하부 구조시스템의 결합을 위해 전이보를 이용한다. 상부의 하중을 하부의 기둥 부재에 효율적으로 전달하기 위해 전 이보가 큰 강성을 지녀야하고 이로 인해 부재의 춤이 커져 많은 물량의 투입되고 전반적인 경제성이 떨어지게 된다. 이러한 문제점을 해결하기 위해 기둥을 벽체요소로 대체하고 일반적인 콘크리트 전이보에 비해 규모가 작은 경계보를 수평 구조요소로 활용한 새로운 경계보-벽체 시스템을 제안한다. 제안된 시스템의 축하중에 대한 성능 평가를 위해 3차원 비선형 유한요소해석을 수행하였다. 주요 설계변수로 상하부벽체 길이비, 경계보 부재의 전단보강근 간격, 하부벽체로 연속되는 상부벽체 수직근의 꺾임 비율, 슬래브 길이를 설정하고 제안된 시스템의 성능에 얼마나 기여하는지 분석하였다.
본 논문에서는 포스트 텐션으로 보강된 아웃리거 벽체의 부등기둥축소량 저감 효과를 확인하였다. 아웃리거 벽체 시스템을 사용할 경우 콘크리트 부재를 아웃리거로 사용하기 때문에 아웃리거 벽체의 장기거동도 고려해야 한다. 아웃리거 벽체은 깊은 보의 형태로 전단 응력이 지배적이기 때문에 전단 응력을 받는 콘크리트의 장기거동에 대한 이론 연구를 수행하였고 그 결과를 유한요소해석에 적용하였다. 아웃리거의 장기거동 고려 시 부등기둥축소량과 아웃리거에 작용하는 전단력을 확인하였으며, 설계 변수인 아웃리거의 두께를 변경해가며 해석하였다. 해석 결과 부등기둥축소량은 증가하고 아웃리거에 작용하는 전단력은 감소함을 밝혔으며 아웃리거의 강성이 작을수록 그 효과가 크다는 것을 밝혔다. 이후 아웃리거의 장기거동으로 인해 증가한 부등기둥축소량을 감소시키기 위해 포스트 텐션 공법으로 보강하는 방법을 제안하고 그 효과를 확인하였다. 프리스트레스 도입 직후의 프리스트레스 손실과 장기거동에 의한 프리스트레스 손실을 모두 고려하였다. 해석 결과 포스트 텐션 공법의 뛰어난 부등기둥축소량 저감 효과를 확인하였으며, 프리스트레스의 크기가 증가할수록 그 효과가 증가함을 밝혔다.
본 논문에서는 초고층 건물의 철근콘크리트 아웃리거 벽체 개구부의 최적설계를 위한 수학적 최적화 프레임워크를 제시하였다. 전용 유한요소해석 프로그램을 이용하여 아웃리거 벽체를 해석하였으며 깊은 보의 스트럿-타이 거동을 고려하여 개구부를 배치하였다. 최적화를 위해 파이썬 SciPy 라이브러리 중 순차이차계획법(Sequential Quadratic Programming)을 이용하여 제약 경계 최적화를 수행 하였다. 최적화에 필요한 미분가능한 연속 함수를 얻어내기 위해 선형 보간법을 사용하였으며, 최적화 프로그램의 효율성을 위해 데이터베이스를 이용하였다. 2변수 최적화의 결과를 탐색 알고리즘의 이동 경로를 통해 살펴본 결과 알고리즘이 최적화된 결과를 효율적으로 찾아냄을 확인하였다. 그리고 개구부의 폭을 모두 같게 설정한 것이 아닌 각각의 개구부의 크기를 개별 변수로 설정하였을 경우 목적함수의 값이 최소화되어 더 우수한 최적화 결과를 도출함을 확인하였다. 또한, 최적화의 과정에 있어 데이터베이스를 이용할 경우 최적화 시간을 효과적으로 단축시킬 수 있음을 확인하였다.