철근은 콘크리트와 결합하여 인장 능력을 보완하고 표면 피막으로 부식을 방지하지만, 탄산화 및 염화물 침투로 인해 부식이 발생하면 내력이 저하된다. 이를 해결하기 위해 내부식성이 뛰어난 GFRP(Glass Fiber Reinforced Polymer) 보강근이 철근 대채제로 주 목받고 있다. 본 연구는 직경에 따른 GFRP 보강근의 부착특성을 철근과 실험적으로 비교 분석하였다. 콘크리트는 약 39MPa의 고강도 에 가까운 콘크리트를 사용하였으며, 보강근의 직경은 D10과 D13을 사용하였다. 실험 결과, GFRP 보강근의 평균 부착 응력은 17.21MPa로 철근의 18.14MPa와 유사하게 나타났다. GFRP 보강근의 슬립 양은 3.05mm로 철근의 1.53mm 보다 크게 나타났다. 또한 GFRP의 경우 인발 과정에서 표면에 국부손상이 발생하는 것을 확인하였다.
The paper presents the experimental investigation of RC beams retrofitted with Textile Reinforced Mortar (TRM), featuring enhanced bond capacity. Anchoring systems, including an extension of retrofitting length and the use of chemical anchors, are newly employed to improve the structural performance of the RC beam retrofitted with TRM. For the experimental investigation, a total of seven shear-critical RC beams, with and without stirrups, were designed and constructed. The structural behaviors of specimens retrofitted with the proposed TRM methods were compared to those of non-retrofitted specimens or specimens strengthened with conventional TRM methods. Crack pattern, force-displacement relationship, and absorbed energy were evaluated for each specimen. The experimental results indicate a significant improvement in the shear capacity of the RC beam with the proposed retrofitting method. Therefore, it is concluded that the application of an extended retrofitting length and chemical anchors to the TRM retrofitting method can effectively enhance the bond capacity of TRM, thereby improving the shear performance of RC beams.
본 연구에서는 GFRP(Glass Fiber Reinforced Polymer)를 주 보강근으로 사용하였으며, 정착길이가 없는 시험체를 제작 하여 4점 재하 휨시험을 수행하였다. 각 변수는 공칭지름이며 공칭지름 D13, D16, D19, 총 3가지의 변수로 이루어져있다. 휨 모 멘트는 공칭지름이 커질수록 약24.17%, 45.92% 강도가 증가하였으나 공칭 휨 강도를 고려하였을 때, 인장 강도와는 달리 공칭 지름에 비례하여 유사한 성능을 나타냄을 알 수 있었다. LVDT로 보강근과 콘크리트와의 부착성능을 확인하였고, 그 값은 매우 미미하며 거의 발생 되지 않은 것으로 판단된다. 또한 DIC로 시험체의 처짐을 확인하였으며, 실세 처짐 값과 유사함을 알 수 있었다.
선박에 부착된 수중생물은 선체에서 성장하면서 선박의 저항을 크게 증가시킬 뿐만 아니라 부착생물이 배와 함께 이동하면서 지역의 해양 생태계 교란을 야기시키기도 한다. 이에 따라 국제해사기구에서는 선체부착생물의 이동을 막기 위해 선체부착생물 제거 및 청소성능 평가 논의를 시작해 오고 있다. 본 연구에서는 소형선박에 사용되는 FRP(Fiber Reinforced Plastic), HDPE((High Density Polyethylene), CFRP(Carbon Fiber Reinforced Plastic) 재료의 시편을 격포항(전락북도)에 약 80일간 양생시킨 후 물 제트 노즐을 이용하여 부착생물 제거실 험을 수행하였다. 그 결과 김과 같은 해조류는 노즐과 시편과의 거리가 1.8cm, 100bar 일 때 제거되었지만, 따개비의 경우 200 bar 이상은 되어야 청소가 되는 것을 확인하였다.
국내 철근콘크리트 구조물은 겨울철 영하의 날씨로 매년 동결융해가 반복된다. 동결융해의 영향으로 철근콘크리트 구조물에 여러 가지 문제가 발생한다. 동결융해에 의해 손상이 된 철근콘크리트 구조물을 보강하기 위하여 다양한 보강공법 중 CFRRP(탄소섬유강화플라스틱)보강공법을 사용하였다. CFRP는 고강도, 고탄성 경량 소재로 시공성이 우수하며 인장강도, 탄성계 수가 뛰어나다. 본 연구에서는 동결융해 환경에 노출된 철근콘크리트 보(FTB), CFRP 플레이트로 보강한 철근콘크리트 보(FPB), CFRP 플레이트로 보강한 후 동결융해 환경에 노출된 철근콘크리트 보(FFP)의 휨 성능 실험을 하였다. 실험결과 FTB는 최대강 도 도달 이후 강도가 급격하게 감소하였다. FPB는 최대강도 도달하기 전에 강도와 강성이 증가하지만 CFRP 플레이트의 조기 파괴 후에는 효과가 없음을 보여준다. 또한 FFP는 FPB보다 최대강도가 낮았다. 이는 동결융해에 의한 콘크리트 표면과 CFRP 플레이트 사이의 계면전단응력의 감소로 판단된다.
최근 건축물의 보수보강 및 리모델링시 구조부재를 부착시키거나 고정하는데 있어서 시공의 유연성 및 용이성으로 후설치 부착식 케미컬앵커의 사용이 증가하고 있는 실정이다. 그동안 후설치 익스팬션앵커에 대한 내력평가는 지난 10년간 실 험을 통한 연구가 지속되어 설계기준식 제정등 어느정도 정립단계에 있으나, 부착식 케미컬앵커에 대한 해석 및 실험적 연구는 아직 미비한 실정으로, 현재 설계자와 시공자가 신뢰할 수 있는 명확한 설계기준이 없는 상태로서 외국의 설계기준에 의존하고 있는 실정이다. 따라서 본 연구에서는 부착식 캡슐형 및 주입형 케미컬앵커의 볼트직경, 매입깊이, 연단거리 그리고 앵커간격를 변수로 한 인발시험을 통하여 비균열 무근 콘크리트에 매입된 케미컬앵커의 인발내력에 미치는 제요소를 분석하고, 구조적 안 정성을 고려한 합리적인 부착식 케미컬앵커 설계를 위한 기초자료를 제공하는 것을 그 목적으로 한다.
철근의 부식 문제를 해결하기 위해 최근 복합재료 기반의 철근이 개발되어 사용되고 있으며 CFRP 그리드도 개발되어 구조부재로 사용되기 시작하고 있다. 그러나 CFRP 그리드의 부착 특성과 응력을 연구한 경우는 매우 드물다. 이에 본 실험은 CFRP 그리드의 부착거동, 부착응력을 평가하고 정착길이를 산정하기 위해 다양한 길이의 정착길이를 가진 인발실험체를 제작한 후 인발하였으며 실험 결과 부착력의 경우 정착길이가 길어질수록 커지며 반대로 부착응력은 정착길이가 길어질수록 작아지는 결과를 얻을 수 있었다. 이는 FRP 보강근도 같은 경향을 보이지만 CFRP 그리드와 FRP 보강근의 차이점은 부착응력의 추세선의 경향에서 두드러지며 또한, 최대 부착력 이후 거동에서 차이를 나타냈다. 위 실험 결과를 토대로 CFRP 그리드의 정착길 이를 산정한 결과 본 연구에서 사용된 CFRP 그리드의 보수적인 정착길이는 250mm로 나타났다.
철근콘크리트 기둥에서 후프철근의 내진갈고리 시공성을 개선하기 위하여 기존 연구에서 “띠철근 갈고리 뽑힘 방지 장치”인 RCC장치(Rebar Confinement Clip)를 제안하여 인발실험을 통한 부착 및 정착성능 실험을 실시하였다. 그러나, 기존 연구의 실험에서는 콘크리트 구조기준에서 제시하는 피복두께를 준수하지 않았다. 그러므로, 보다 신뢰성 있는 실험 결과를 도출하 기 위하여 기준에서 제시하는 피복두께를 준수한 실험체로 실험을 실시할 필요가 있다. 이를 위하여 총 6개 실험체를 제작하여 실험을 실시하였으며 실험결과, 부착 및 정착의 합성강도는 RCC장치로 체결된 띠철근의 갈고리가 내진갈고리가 발휘하는 강도 보다 높게 나타났다. 또한, 내진갈고리의 실험체 균열 진전 및 파괴 양상과 RCC장치로 체결된 띠철근의 실험체는 유사하게 나타났다. 그러므로, 콘크리트 피복두께를 준수한 실험체에서 RCC장치로 띠철근에 체결할 경우 내진갈고리가 발휘하는 동등한 성능을 보유하고 있는 것으로 평가된다.
FRP 시트(Sheet)를 활용한 보강 공법은 제작 과정에서의 간편함과 시공의 용이성으로 현장에서 다수 적용되고 있으며, 기존 연구자들은 FRP 시트로 보강한 철근콘크리트의 휨강도를 예측하기 위한 연구를 진행하였다. 그러나 이는 주로 탄소 섬유와 유리 섬유에 한정되어 있었다. 이 연구에서는 바잘트 섬유시트의 역학적 성질을 파악하기 위하여 물성 시험을 수행하였으며, 바잘트 섬유시트로 보강한 철근콘크리트 보의 휨실험을 수행하였다. 휨실험 결과 보강량이 증가할수록 실험체의 내력이 증가하였다. 또한 휨파괴 및 시트 파단, 시트 부착 탈락, 시트 박리가 발생하였다.
In this study, an experimental study was carried out to evaluate the bond shear performance according to the shear connector between the glue-laminated timber and steel interface. Ten block shear specimens were fabricated according to the configuration of the adhesive surface of wood and steel. In addition, four test specimens were produced according to the main variable shape of the wood-concrete shear connector. As a result of the block shear test, the shear strength of the steel-wood adhesive is shown to have a shear performance greater than the wood-wood shear strength. As a result of the push-out test according to the shape of the shear connector, the shear strength increased linearly with the attachment area. The complete composite behavior between the glued-laminated timber and the steel can be secured.
In this study, the static load test and the load transfer test were carried out to evaluate the structural performance of the circular anchorage proposed by the previous study. Specimens were fabricated according to KCI-PS101 and ETAG 013. As a result of the static load test, it was verified that the displacement of the wedge and the strand was kept constant when the tensile force of 80% of the nominal strength of the strand was applied. In the load transfer test, it was confirmed that all the specimens satisfied the stabilization formula of KCI-PS101 and ETAG 013. Post-tensioned one-way slab with circular anchorage were fabricated to evaluate the flexural behavior. All specimens exhibited the same flexural behavior and maximum load. However, the specimen with circular anchorage were advantageous than the rectangular anchorage one in terms of crack control of the anchorage zone.
In this study, we conducted a shake table test to verify the seismic performance of the paneling system with steel truss composed of bolt connections. The control group was set to the traditional paneling system with steel truss connected by spot welding method. Test results showed that the bolted connection type paneling system has excellent deformation capacity without cracking or brittle fracture of the steel truss connection parts compared to the welding type paneling system. Furthermore, in the bolted connection type, slight damage occurred at the time of occurrence of the same story drift angle as compared with the existing method, it is considered that it has excellent seismic performance. In compliance with the performance-based design recommended for the current code (ASCE 41-13) on non-structural components, it is judged that in the case of the bolted connection type paneling system, it can be applied to all risk category structures without restriction. However, in the case of traditional paneling system with spot welding method, it is considered that it can be applied limitedly.
GFRP(Glass Fiber Reinforced Polymer Plastic) has a superior corrosion resistance, high specific strength/stiffness, etc. Therefore, such properties can be used to mitigate the problems associated with the use of conventional construction materials. In this study, the various rib and pitch distance of hybrid fiber GFRP bars were evaluated by experimental method. From the test result, thirty two types of FRP hybrid bars such as spiral type with the dimension of rib geometry were fabricated. To evaluate the bond properties of them, direct pull-out test was performed. All testing procedures including specimen preparation, set-up of test equipment and measuring devices were made in accordance with the recommendations of ASTM D 7913. From the test results, it was found that cross type hybrid GFRP reinforcing bars showed the highest bond strength than that of the others due to the higher relative rib area.
최근 신설도로의 증가로 도로의 총 연장이 급증하여 현재 국내도로연장은 10567km에 이르며 아스팔트 포장의 비율은 87.3%로 콘크리트 포장에 비해 월등히 긴 연장을 보인다(국토교통부, 2015). 또한 공용년 수가 증가하고 교통 및 환경의 복합적인 요인들로 인해 도로포장의 파손이 광범위하게 발생되고 있는 실정 이다. 포장체의 구조, 포장을 구성하는 재료와 더불어 환경 및 교통하중에 영향을 받아 도로 포장에서는 러팅(rutting), 피로균열(fatigue cracking), 반사균열(reflection cracking), 온도균열(temperature cracking)등의 파손이 발생하여 설계수명에 도달하기 이전에 유지보수가 실시해야 한다(한국도로공사, 1999). 섬유그리드 보강 아스팔트 포장은 무근 콘크리트 포장에 Wire Mash를 설치하는 개념과 같이 아스 팔트 표층을 포설하기 전 표층과 중간층 사이에 섬유보강재를 설치하는 포장이다. 섬유그리드 보강 포장기 법은 하부에서 발생되는 균열에너지를 보강재가 분산시켜 균열 상승을 차단함으로서 반사균열을 지연시키 거나 정지시키고 표층에서 인장력에 의해 발생되는 골재의 횡 방향 이동에너지는 하부기층까지 확장하려 는 응력을 섬유보강재로 억제시킴으로서 소성변형을 저감할 수 있다. 본 연구에서는 섬유 그리드로 보강된 콘크리트 및 아스팔트포장 덧씌우기가 적용된 구간에서의 시공현황분석 및 유관조사를 실시하였다. 고속 도로의 경우 섬유그리드포장 덧씌우기와 일반아스팔트 포장 덧씌우기 시공구간의 PMS 데이터를 이용하여 노면결함 추적조사를 실시하였다. 일반 국도의 경우 섬유그리드 적용구간과 일반 아스팔트포장을 비교구 간으로 선정하여 PMS 데이터를 통한 노면 결함 추적조사를 실시하였으며, 각 구간에서의 코어링 실시 후 부착전단강도실험을 통해 기존에 시공되었던 일반 아스팔트포장과의 비교 ․ 분석을 실시하였다.
The present experimental study investigates single-phase heat transfer coefficients downstream of support grid in 6×6 rod bundles. Support grid with Split mixing vanes enhance heat transfer in rod bundles by generating turbulence but this turbulence is confined to a short distance. Support grid with large scale vortex flow(LSVF) mixing vanes enhanced heat transfer to a longer distance. In this study, the experiments were performed at reynolds numbers of 50,000. The characteristics of the heat transfer enhancement of the Split mixing vane and those of the LSVF mixing vane were compared. The results showed that the characteristics of the heat transfer enhancement of rods by the Split mixing vane were limited to 10 Dh after the spacer grid, but those by the LSVF mixing vane were maintained until 15 Dh after the spacer grid. For the reynolds number of 50,000, the heat transfer enhancement effect was 3.0% greater when using the LSVF mixing vane than when using the Split mixing vane between the 1 ∼ 15 Dh interval after the spacer grid.
본 연구에서는 내력벽 시스템에 대하여 연결보의 단부에 적용이 가능한 박판형 금속감쇠기의 성능을 실험을 통하여 규명하고자 하였다. 박판형 금속감쇠기의 박판 두께와 길이를 변수로 하여 5개 시험체를 제작하였으며, 층간변위비 5%까지 반복하여 횡력을가력하였다. 실험결과, 금속 박판에 좌굴발생 후 소성변형이 발생하면서 에너지 발산이 이루어졌으며, 기존의 일반 콘크리트 시험체보다에너지 발산량이 크게 나타났다. 박판의 길이가 짧을수록 전단내력의 값은 증가하였으나 발산에너지의 양의 증가는 크게 나타나지 않았다. 실험 내력을 탄성좌굴해석과 비교한 결과, 해석에 의한 내력은 내력곡선 선형영역의 최대값을 적절히 예측함을 알 수 있었다.