검색결과

검색조건
좁혀보기
검색필터
결과 내 재검색

간행물

    분야

      발행연도

      -

        검색결과 30

        1.
        2024.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The aim of this study is to evaluate the possibility of damage to cultural assets resulting from vibrations generated by construction vehicle traffic. The cultural heritage's natural vibration frequency was determined to be 150Hz by measurement. The damping ratios were calculated as 4.7% using the logarithmic decrement approach and 4.3% using the half-power method. The vibration measurements obtained during vehicle operation indicated that, despite an increase in vehicle velocity of up to 15 km/h, the vibrations remained below the detectable level of 0.13 mm/sec. When the road is curved and the terrain is sloped, a suitable speed for vehicle operation was found to be around 17 km/h, at which point vibrations were seen. The highest recorded vibration amplitude at this velocity was 0.217 mm/sec, which remains below the stringent regulation limit of 2 mm/sec. Thus, it can be concluded that there is no actual harm caused by vibrations.
        4,000원
        2.
        2023.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, we performed thermal safety design of the electric module of a heat-loaded equipment with consideration of its heat dissipation performance. Initially, we calculated the heat dissipation of natural convection to choose a cooling method. Based on this, we found that some modules required forced convection and selected an air-cooling method with an outdoor temperature of 43 degrees Celsius, which is the maximum temperature in Korea. Prior to module production, we performed thermal analysis of each module and proceeded with a design to increase the thermal conductivity of the module as a primary step, and subsequently proceeded with Heat Sink design to maximize the heat dissipation performance. After considering various constraints according to the system requirements and designing the cooling path, we experimentally and analytically secured thermal safety at the operating temperature of the equipment.
        4,000원
        3.
        2022.04 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This research studied faults that may occur during slow charging using the J1772 adapter of Tesla Model-3 electric vehicles. When the AC terminal was instantaneously disconnected, charging was performed normally when an AC circuit with disconnection up to three disconnection times was connected. Charging control was suspended when the number of disconnection reached four times. However, if the AC disconnection time exceeded 22 seconds, the charging control was stopped regardless of the number of disconnection. When a contact failure occurred at the AC terminal, high surge current and noise occurred. However, when the contact improved, the charging control continued. In terms of safety, it seems necessary to take measures such as stopping charging control when detecting noise.
        4,000원
        4.
        2020.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        연소실 내 공조현상으로 인해 발생되는 열음향 불안정성은 안정적인 연소시스템을 구현하기 위해 해결해야 하는 고질적인 문제로 제기되어 왔다. 열음향 불안정성은 크게 1차 2차 열음향 불안정성으로 나뉘며, 본 연구에서는 열음향 불안정성 중 2차 열음향 불안 정성의 천이에 관해 열손실이 미치는 영향에 대한 실험적 연구를 진행하였다. 2차 열음향 불안정성을 발생시키기 위해 한쪽 끝이 열린 1/4 파장 공명기를 채택하여 수직으로 설치하였고, 공명기 내부에는 예혼합 가스를 주입하였다. 또한 공명기 상단으로 발생하는 열손실 효과를 비교하기 위해 추가적으로 외부 동축류 관을 설치하였다. 연료 농후조건의 예혼합 가스만을 채택하여 주입하였기 때문에 동축관 에 주입되는 기체에 따라 공명기 상부에 추가적인 확산화염이 형성될 수 있다. 그 결과 확산화염이 발생되었을 경우 공명기 상단으로의 열손실이 감소하며 2차 열음향 불안정성이 발현되었으며, 확산화염이 억제되어 공명기 상단으로의 열손실이 증가하였을 경우 2차 열음향 불안정성의 발현이 억제되는 결과를 도출하였다.
        4,000원
        5.
        2019.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The diesel engine generate many pollutants such as PM(Particulate matter) and NOx(Nitrogen oxide). So the SCR(Selective catalytic reduction) must be required to meet the emission standard. The SCR catalyst market is growing rapidly, and the automobile markets using alternative energy sources are growing rapidly. This study deals with optimization of the calcination process the manufacturing process of SCR catalyst to be competitive. The calcination process is a bottleneck and it is required to optimize productivity and accept to be safety, But we cannot trade off anything in terms of safety. We applied DOE(Design of experiments) among many research methods performed in various fields. In order to achieve quality and productivity optimization. The dependent variables in the DOE were selected as NO Conversion(%). The independent variables were selected as the calcination temperature, soaking time and fan speed RPM. the CCD(Central composite designs) constructs response surface using the data onto experience and finds optimum levels within the fitted response surfaces. Our tests are our stability guarantee and efficient together with operation.
        4,000원
        6.
        2016.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        예부선이 항행할 경우 부선의 회두운동으로 인하여 예선은 조종성능에 제한을 받기 때문에 부선의 회두운동을 감소시켜야 안전한 예항업무를 이행할 수 있다. 본 연구에서는 부선의 침로안정성을 향상시키기 위한 방안으로 부선의 회두운동에 영향을 미치는 항목들을 조사하기 위하여 수조실험을 실행하였다. 선수 형상에 따라 회두운동 특성이 다르게 나타나기 때문에 서로 다른 선수 형상을 지닌 부선 모델을 대상으로 스케그의 영향, 예인선속의 영향, 예인삭 길이의 영향, 브라이들의 영향에 대하여 종합적으로 분석하였다. 실험결과 스케그의 설치 위치에 의한 효과는 선수형상에 따라서 다르게 나타나고 있는 모습을 보여주고 있다. 부선의 회두운동은 부선에 연결된 예인삭의 길이가 길수록 부선의 회두가 작아짐을 알 수 있었다. 또한 예인삭만 연결한 상태보다 예인삭에 브라이들을 연결하는 것이 부선의 회두가 작아지며, 브라이들의 길이가 길어질수록 부선의 회두운동이 크게 작아짐을 알 수 있었다.
        4,000원
        7.
        2014.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 갯벌토 및 준설토를 기질로 이용한 Mesocosm 실험을 통하여 염생식물의 서식안정성을 평가하였다. Mesocosm 실험구는 기질 및 식생의 식재 여부에 따라 Mesocosm A(갯벌토+퉁퉁마디 식재), Mesocosm B(준설토), Mesocosm C(준설토+퉁퉁마디 식재)로 조성하였다. 그리고 Mesocosm 실험구 내 염생식물의 서식안정성을 평가하기 위해 수질(COD, T-N, T-P, 수온, 염분), 저질(COD, T-N, T-P), 식생성장률의 서식환경 인자에 대한 모니터링을 실시하여 서식안정성지수(HSI)를 산정하였다. Mesocosm C에서의 HSI는 0.87~0.95로서 Mesocosm A에 비하여 상대적으로 HSI가 높게 산정되어, 준설토를 이용한 해안염습지의 복원/조성에 이용될 수 있을 것으로 평가되었다.
        4,000원
        8.
        2014.08 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 수중익 배치와 종모멘트 특성이 전몰형 수중익선의 종방향 운동 안정성에 미치는 영향에 대하여 Tandem 수중익 모형의 시험을 통하여 고찰한다. 먼저, Canard 날개배치를 가지는 Tandem 수중익 모형을 제작하고 수중익의 양력 및 항력 계측 실험을 수행하여 양력 및 항력 특성을 평가하였다. 또한 종방향 운동의 초기 안정성과 자기 안정성을 가지는 Tandem 수중익 모형의 날개 배치를 결정하였다. Tandem 수중익 모형의 종안정성 시험에서는 선수 및 선미 수중익의 종방향 간격 변화와 종모멘트의 자기안정성 변화에 따른 Pitch 및 Heave 운동 특성, 익주 상태의 종안정성을 평가하였다. 먼저, Canard 날개배치를 가지는 Tandem 수중익 모형을 제작하고 수중익의 양력 및 항력 계측실험을 수행하여 양력 및 항력 특성을 평가하였다. 또한 종방향 운동의 초기 안정성과 자기 안정성을 가지는 Tandem 수중익 모형의 날개 배치를 결정하였다. Tandem 수중익 모형의 종안정성 시험에서는 선수 및 선미 수중익의 종방향 간격 변화와 종모멘트의 자기안정성 변화에 따른 Pitch 및 Heave 운동 특성, 익주 상태의 종안정성을 평가하였다. 실험 수행 결과 본 연구의 주요 결론의 다음과 같다. 종 모멘트 자기 안정성이 클수록 주어진 고정 pitch 각에서 pitch운동에 대한 자기안정성이 높다. 다음 종모멘트 자기 안정성이 클수록, pitch각도 변화에 따른 pitch운동 및 heave운동의 변동 폭이 상대적으로 작으며 종방향 안정성이 우수하다. 마지막으로 종모멘트 자기안정성이 클수록, 수중익 양력이 동일한 경우, Tandem 수중익의 안정적인 익주를 위해서는 충분한 종모멘트의 자기안정성을 확보하는 것이 필수적인 것을 시험을 통하여 확인하였다.
        4,000원
        10.
        2014.06 구독 인증기관 무료, 개인회원 유료
        여객과 화물의 고속 해상수송을 위하여 다양한 형태의 고속선이 개발되고 있으며 특히 40노트 이상의 고속 운항에 적합한 전몰형 수중익선에 대한 연구가 요구되고 있다. 전몰형 수중익선은 익주 상태의 안정적인 운항을 위해서는 종방향 운동의 안정성 확보가 필수적이다. 본 연구에서는 수중익 배치와 종모멘트 특성이 전몰형 수중익선의 종방향 운동 안정성에 미치는 영향에 대하여 Tandem 수중익 모형의 시험을 통하여 고찰한다.
        3,000원
        11.
        2011.11 구독 인증기관 무료, 개인회원 유료
        In this paper Using a TTP to the experimental study on the stability of the Submerged breakwaters would like to perform. Experiment conditions consisted of structure conditions and incident wave conditions. Submerged breakwater which consisted of two layer installed in wave flume. height and crest width of submerged breakwaters are 8.6cm and 80cm, respectively. The three types of TTP were used: normal type, safety type, safety type(connect). In this study, rocking rate of submerged breakwater applied the general definition in Shore Protection Manual. Damage in terms of displaced blocks is generally given as the relative displacement, D, defined as the proportion of displaced blocks relative to the total number of blocks. Rocking rate was plotted in Figure 5 as function of Lb/L0. h=2.0hs, T=2sec case rocking rate of normal tetrapod are 57.1 %, safety tetrapod are nonrocking. Experimental result shown that stability of safety tetrapod higher than normal tetrapod.
        3,000원
        12.
        2010.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구에서는 강풍시 차량의 주행안정성을 확보하기 위하여 분출형 방풍벽을 고안하였으며 풍동실험을 통하여 그 유효성을 검증하였다. 풍동실험에서는 4종류의 분출형 방풍벽과 기존의 다공형 수직방풍벽 2종류에 대해서 간이차량모형의 표면압을 측정하였으며 방풍벽으로부터 차량의 이격거리 및 성토부의 유무에 따라 방풍벽의 성능을 고찰하였다. 실험결과, 본 연구에서 고안된 분출형 방풍벽은 충실율 25%~50% 사이의 수직방풍벽과 동등한 방풍효과를 가지는 것을 확인하였으며 운전자의 시야확보에 유리하며 교량구조물에 적용시에는 기존의 방풍벽에 비하여 수풍면적이 감소하여 공기력을 저감시킬 수 있는 신개념의 방풍시설이 될 수 있을 것으로 기대된다.
        4,000원
        13.
        2010.03 KCI 등재 구독 인증기관 무료, 개인회원 유료
        On cold start operation of an SI engine, a catalyst shows poor performance before it reaches activation temperature. Therefore, fast warmup of the catalyst is very crucial to reduce harmful emissions. In this study, an appropriate control strategy is investigated to increase exhaust gas temperature through changes of spark timing and exhaust valve timing. Combustion stability is also considered at the same time. Experiments showed that retarded spark timing promotes the combustion at the end of expansion stroke and increases exhaust gas temperature during cold start.An advance of exhaust valve timing decreases residual gas in cylinders due to decrease of valve overlap period. It helps improvement combustion stability by virtue of reduced residual gas. A control strategy of proper valve timing and spark timing is suggested in order to achieve fast light-off of the catalyst and stable operation of the engine in a cold start and idle operation
        4,000원
        14.
        2006.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        π형 단면은 장대교량에서 경제적인 대안으로서 보강거더의 단면형상으로 채택되고 있지만, 동적 내풍안정성에는 취약한 면을 보이고 있다. 본 연구에서는 π형 단면의 동적 내풍안정성을 향상시킬 방안으로 공기역학적 제진장치중 extensioner를 사용하여 비틀림 플러터 풍속의 향상을 도모하고, 가장 효과적인 extensioner의 단면비를 제안하고자 한다. 따라서 플러터를 발생시키기 위해서 등류조건에서만 실험을 실시하였으며, 변장비 B/D=7.7~12.5를 가지는 총 6가지 기본단면에 9가지의 형상비를 갖는 extensioner를 모형으로 제작하여 실험을 실시하였다. 실험결과 변장비 B/D=7.7에서 가장 낮은 플러터 발생풍속을 보였으며, extensioner최적의 단면비는 α=30o~40o, a/b=0.59~0.84일때 β=12.8o~25o, b/ B=0.08~0.12일 때 효과가 우수하였다.
        4,200원
        17.
        1999.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        지진의 연직성분에 의해 유발된 해진시 단일개단말뚝의 거동에 관한 이전의 연구들에서 단일개단말뚝의 지지력은 완전히 감소되었으며 관내토의 폐색도 완전히 파괴된 것으로 밝혀졌다 그러나 개단말뚝이더라도 말뚝의 관입길이가 길 경우 해진에 대하여 말뚝이 안정성을 유지할수 있고 개단강관말뚝일 경우에는 비교적 관입깊이가 짧을 경우에도 해진에 대하여 안정성을 유지할 수있을 것으로 예상된었다 본 연구에서는 초세립질 포화모래지반을 담고 잇는 소형압력토조에 단일개단말뚝 2개 또는 4개의 개단무리말뚝을 관입길이 7-40m로 모델링하여 관입시켰으며 각각의 말뚝에 대하여 압축정재하시험을 실시한후 극한지지력의 약 95%의 압축하중을 재하시킨 상태에서 해진의 진동을 작용시키면서 지지력의 감소를 확인하였고 해진 작용후의 각각의 말뚝에 대하여 압축정재하시험을 실시하였다. 해진시 천해에 설치된 단일개단말뚝과 군말뚝의 지지력은 감소되지 않았다 그러나 심해에 설치된 말뚝의 안정성은 말뚝의 지중관입 깊이에 좌우되었다 즉 27m이상 관입된 단일개단말뚝의 지지력은 안정하였으며 13m이상 관입된 2개 및 4개 군말뚝은 안정하였다 그런 7m 관입된 2개 군말뚝은 파괴되었으며 7m 관입된 4개 군말뚝의 지지력은 15%만큰 저감되었다.
        4,000원
        18.
        2017.03 KCI 등재 서비스 종료(열람 제한)
        As the amount of slag generated annually increases, attempts to recycle slag as high value products are underway in order to develop an efficient resource recycling industry based on slag and derive economic benefits as well. However, the application of electric arc furnace (EOS) slag as construction material is practically limited because of the unstable substances included in it, such as free CaO.(EOS contains a small amount of free CaO, but several limitations still exist. Slag is stored for more than 3 months depending on the quantity of slag, which leads to additional economic loss. In this study, the amount of free CaO present in EOS is quantitatively evaluated to examine its qualities as a potential construction material and verify its application as concrete material. The quantitative analysis of free CaO present in EOS is performed using ethylene glycol. The free CaO contents of EOS samples were found to be below 0.5%. This satisfies the criteria specified in KS F 4571, which states that the CaO content should be below 40% and CaO/SiO2 ratio should be below 2.0. In addition, it was confirmed that free CaO content difference appears to be dependent on the aging period and storage position.
        19.
        2016.03 KCI 등재 서비스 종료(열람 제한)
        최근 수십년간의 산업화로 인해 인간중심의 하천 개발이 이루어진 결과, 하천의 직강화 및 복개화 등 오수 및 하수의 배출구로만 활 용되어 집중호우 등의 수해가 반복되어 발생하고 있어 이에 대해 하천 및 제방의 사면을 각종 공법을 통하여 손상을 방지하고 있으나, 관련 기 준에서는 비탈높이, 최소비탈경사 등 최소한의 기준만 제시하고 있는 실정이다. 또한 홍수해 방지를 위한 가장 중요한 특성인 소류력에 대한 검토는 전무한 실정이다. 따라서 본 연구에서는 실규모의 인공실험하천에서 다공성콘크리트 호안블록을 설치하고, 유입유량을 조절하여 각 실험조건에 따른 유속 및 수심을 측정하여 소류력을 평가하였다. 다공성콘크리트블록의 압축강도 및 공극률 시험결과 압축강도는 16.6~23.2 MPa의 범위로 측정되었고, 실측공극률은 10.1%로 나타나 국내 기준을 만족하는 것으로 판단되며, 소류력 시험결과 한계소류력은 47.202 N/m2으로, 하천설계실무요령에서 제시된 급류부의 소류력 범위인 67 N/m2은 만족하지 못하는 것으로 나타났다. 하지만 블록 및 기반층의 유 실이나 손상이 전혀 관찰되지 않았고, 기존 선행연구를 참고하여 볼때 그 이상의 소류력에도 저항력을 가질 수 있을 것을 추정하여 볼 수 있다. 따라서 추후 실험조건 등을 조정하여 실질적인 한계소류력 측정을 위한 실험을 다시 수행할 필요가 있다고 판단된다.
        20.
        2015.02 서비스 종료(열람 제한)
        수중구조물은 구조물 마루가 수면 위로 드러나지 않아 자연경관을 해치지 않으며 해수소통이 원활하게 이루어지는 장점을 가지고 있어 1990년대부터 유럽과 일본을 중심으로 다양한 연구가 이루어졌고, 현장에 적용되고 있다. 현재 우리나라에서도 연안침식 저감 등을 목적으로 수중구조물의 설치사례가 증가하고 있는 실정이다. 그러나 우리나라는 수중구조물에 대한 연구가 상대적으로 미흡하여 해외자료를 이용하여 설계를 수행하고 있는 실정이다. 이에 본 연구에서는 수중구조물의 기하학적 제원 및 제체 구성재료 등에 따른 해안수리특성에 대한 검토를 수행함과 동시에 수중구조물 피복재의 안정성을 실험적으로 검토하였다. 수중구조물 설계시, 피복재의 안정중량 산정에는 방파제에 적용되는 피복재 안정중량 산정식을 황요하고 있는 실정으로 수중구조물의 안정중량 산정식은 부재한 실정이다. 따라서 본연구에서는 콘크리트블록과 Tetrapod를 적용한 피복재의 안정성을 실험적으로 검토하였다. 또한 콘크리트블록의 거치방법에 따른 안정성도 비교 평가하였다. 수리실험은 2차원 수로에서 진행되었으며, 불규칙파를 적용하였다. 향후 입사각에 따른 피복재 안정성 및 제두부구간의 안정성 검토를 위한 3차원 실험과 해안수리특성 실험도 진행예정이다.
        1 2