        3.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, according to the staking method of the fire hose in the indoor hydrant system, the number of kinks when the fire hose is deployed was measured and analyzed to examine how the staking method of the fire hose affects the kink when the hose is deployed. The fire hose staking method was classified into three types: donut-type, accordion-type, and hose hanger-type, and the walking speed and number of kinks were measured by repeating the experiment 5 times for male and female students. The results of the study are as follows. (1) Among the three types of fire hose staking methods, the donut-type staking method had an average of 92 times for male students and 86 times for female students on average. (2) The accordion-type and hose hanger-type staking methods showed similar results with an average of one or two kinks for both male and female students. (3) Regardless of the staking method, it was found that in general, male students with high walking speed had more kinking than female students with slow walking speed.
        4,000원
        4.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study is to check waterproof by number of twists of fire hose and measure the first waterproof time to analyze the relationship between twists of fire hose and first waterproof time and waterproof by position of twists so as to suggest the efficient plan to prevent twists of fire hose. Ordinary fire hose did not make waterproof in case that position of twists was near the nozzle with twists 5 times or more, while anti-twist fire hose had no problem for waterproof only with delayed time. Like ordinary fire hose, anti-twist fire hose also showed the tendency to increase the waterproof time in proportion to the number of twists. In case that the position of twists was near waterproof port even with 10 times of twists in anti-twist fire hose, the first waterproof time was increase by 0.63 seconds on average without any problem for waterproof, which was somewhat faster than that in ordinary fire hose. With respect to the position of twists, waterproof of anti-twist fire hose was affected more as the number of twists was increased more near the nozzle rather than near the waterproof port, like ordinary fire hose. In summary, anti-twist fire hose equipped with anti-twist tool at the middle connection port and the nozzle showed a good waterproof performance with delayed waterproof time regardless of number of twists, as a solution for the twist problem of ordinary fire hose.
        4,000원
        5.
        2021.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        The objective of this study was to understand which type of fire hose should be placed in indoor fireplug box upon analyzing the preparation time between rack-type fire hose and reel-type one. With respect to the type of hose, rack-type stacking method was used and hose preparation time was measured with 5 times of repeat test, separating men and women. Study results reveal that preparation time of reel-type fire hose took longer than that of rack-type one in both men and women. For both rack-type hose and reel-type hose, preparation time by two persons took shorter than that by one man. Also, preparation time by three persons took shorted than that by two women. Preparation time for both rack-type hose and reel-type one by men took shorter than that by women. In summary, it was confirmed that rack-type hose could be prepared within shorter time than reel-type one. Since the size of drum set in the reel-type fire hose is relatively small, it had some difficulty in preparation of fire hose timely.
        4,000원
        6.
        2021.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        In this study, the purpose of this study was to examine the effect of twisting in the preparation of waterproofing in the process of unfolded donut-type staking method fire hoses in indoor hydrant system. The central pull-out method caused more twisting than the rolling method, and there was no significant difference in the number of twists according to the pull-out method in the case of male and female students. It was found that the time it took to untwist and prepare waterproofing was much shorter for male students. The angle valve and hose are connected, and the time to untwist and prepare for waterproofing after withdrawing the fire hose with the hose and nozzle connected was shorter than the unconnected state. In the rolling method, when a hose connected with two 15 m fire hoses was used and the angle valve-hose was connected, but the hose-nozzle was not connected, the least kinking occurred. The time to untwist and prepare for waterproofing was also the shortest. As a result, in the withdrawal method of the donut-type loaded fire hose in the indoor hydrant system, it is a rolling method rather than a central withdrawal method. With the angle valve and hose connected, unfold the fire hose with the hose and nozzle connected, if a large number of people unwind the twisted hose, the time to prepare for waterproofing can be shortened.
        4,000원
        8.
        2016.02 구독 인증기관 무료, 개인회원 유료
        This study was carried out to improve the performance of sewer trenchless entire repair method by using the multifunctional safety high-pressure hose. Because the flexural strength and flexing modulus of elasticity increased in the range from 60℃ to 80℃ of the setting temperature, the unform quality was secured to satisfy the standard quality and consolidate the strength, by supplying steam to the entire sewer through the safety high-pressure hose simultaneously. After the steam was supplied, the temperature of the condensate water with a large amount occurred , compared with a small amount, was very low. So, the setting time was shorter over than one hour by reducing the unsatisfied cure state and excluding the condensate water. The standard quality increased by approximately 15% at upper, central, and lower points of the same sewer was gained from the test result of CIPP(cured in place pipes) constructed at the optimum setting temperature. The steam and air were supplied evenly to the sewer by controlling the safety high-pressure hose in the tense and relaxed state and by using the exclusive function of condensate water. The availability and safety for the constructed process were achieved.
        4,000원
        9.
        2015.09 KCI 등재 구독 인증기관 무료, 개인회원 유료
        This study investigates the application of a synthetic resine based net-hose system to sustain vegetated embankment slope reinforcement. The net-hose system is designated to improve water supply to the vegetation that can suffer the lack of water in case of extreme drying condition or rock slope where water supply is relatively insufficient to ensure the growth of vegetation. A series of laboratory tests were conducted to check the structural adequacy and effectiveness of net-hose system. The results indicated that the model slope equipped with net-hose system seemed to provide better water supply resulting in more vegetated areas and higher matric suction due to active water uptake capacity, which might be contributed to greater shear strength of slope surface. A limited numerical analysis was conducted to verify the effect of water uptake on vegetated root system that generally yields better slope stability.
        4,000원
        10.
        2015.04 구독 인증기관 무료, 개인회원 유료
        This study investigates the application of net-hose system to sustain a vegetated slope reinforcement. The net-hose system is designated to improve water supply to the vegetation that can suffer the lack of water in case of extreme drying condition or rock slope where the water supply is relatively insufficient to ensure the growth of vegetation. A series of laboratoy tests were conducted to check the structural adequacy and effectiveness of net-hose net hose system. The results indicated that the model slope equipped with net-hose system seemed to provide better water supply leading to more vegetated areas and higher matric suction due to active water uptake capacity, which might be contributed to greater shear strength of slope surface. A limited numerical analysis was conducted to verify the effect of water uptake of vegetated root system that generally yields better slope stability.
        3,000원
        12.
        2011.06 KCI 등재 구독 인증기관 무료, 개인회원 유료
        본 연구는 여름철에 신선한 곤달비를 생산하기 위하여, 몇 가지 냉각방법에 따른 재배효과를 검토하고 베드의 구조물 및 냉각수단으로서 호스를 이용한 경제적인 팽연화왕겨 간이수경재배베드를 개발하기 위하여 수행하였다. 냉각방법별 곤달비의 생육은 냉수호스, 미스트, 무비가림 순으로 좋았으며, 13℃의 지히수를 약 240/hr의 유속으로 흘려 냉각시켰을 때 지온이 약 2~3℃ 낮아졌다. 여름재배 시 군락부위 부분냉방을 위해 개발된 호스베드시스템은 Φ15cm의 벽과, 유기배지로 팽연화왕겨가 이용된다. 냉수호스베드에서 냉수의 온도가 14~22℃ 범위에서 공급되었을 때 배지의 온도는 18~23℃로 유지되어 냉각효과가 양호하였으며, 스티로폼베드에 비하여 호스베드의 곤달비 군락부위의 온도는 약 0.5℃, 근권부의 온도는 약 3℃ 낮은 등 냉각효과가 있었다. 국부냉방을 위한 호스베드시스템은 곤달비와 같은 키가 작은 엽채류의 여름철 재배에 활용할 뿐 아니라 저온기에는 난방수를 순환하여 별도의 방열배관없이 국부난방에도 활용할 수 있어 경제적인 간이양액재배베드로서 활용될 것으로 기대된다.
        4,000원
        13.
        2007.12 KCI 등재 구독 인증기관 무료, 개인회원 유료
        점적관수 자재 및 분수호스의 관수균일도 실험결과 사용압력과 배관길이에 따라 유출량의 차이가 큰 것으로 나타났다. 점적관수 중에서는 점적단추의 관수 균일도가 가장 높았고, 점적테잎, 점적호스의 순으로 나타났다. 관의 직경과 길이 및 유량에 따라 다르지만 마찰에 의한 압력손실이 상당히 크므로 점적관수의 사용압력과 배관길이 선택에 주의할 필요가 있다. 제품에 따라 약간의 차이는 있었지만 대체로 점적호스는 50m, 점적테잎은 70m 정도를 최대 배관길이로 제한하는 것이 바람직할 것으로 판단되었다. 점적단추는 실험에서 설정한 최대길이인 100m까지도 사용이 가능한 것으로 사료된다. 그러나 관수시스템의 압력을 체크하여 충분한 압력을 확보하고 있는지 검토할 필요가 있고, 부족시 별도의 가압펌프를 설치하여 적정압력 범위를 만족할 수 있도록 하며 물구멍이 막히지 않도록 필터를 설치하고 수질을 관리하는 등의 유지관리가 필요한 것으로 판단되었다. 분수호스의 경우에는 균등계수가 매우 낮아 균일한 관수를 기대할 수 없는 것으로 나타났다. 따라서 균일한 관수 제어를 필요로 하는 높은 수준의 시설재배에서는 가능한 한 점적관수를 사용하고, 비교적 낮은 수준의 배지수분 관리가 이루어지는 시설재배에서도 분수호스를 이용할 경우 배관길이를 30~35m이내로 제한하는 것이 바람직할 것으로 판단된다.
        4,000원