이 연구는 신경독성을 나타내는 cyclic imine (CI) 독소 의 한국 내 수입되는 패류 내의 오염 수준을 분석한 것으 로, LC/MS/MS를 통해서 spirolide, pinnatoxin, gymnodimine 유도체 7종을 대상으로 분석하였다. 총 21개의 수입산 패 류를 수집하여 분석한 결과, 뉴질랜드산 홍합에서 SPX C 가 227.84 ppt, 칠레산 홍합에서 PnTX G가 80.42 ppt, 뉴 질랜드산 홍합에서 Gym A가 118.79 ppt로 검출되었다. 이 러한 결과는 수입산 패류에서 CI 독소가 초래할 잠재적인 위협의 가능성을 나타내며, 소비자 건강 보호를 위하여 지 속적인 모니터링의 필요성을 시사한다. 또한 이러한 독소 가 포함된 패류 제품에 대한 규제 조치의 시행이 필요함 을 시사하며, 이를 보다 잘 이해하고 관리하기 위한 지속 적인 연구가 필요하다.
The reversible metal electrodeposition (RME) process is used to prepare electrochromic mirrors with reflectivetransparent optical states, by depositing metal particles on transparent conductive substrates. These RME based devices can be used in smart windows to regulate indoor temperatures and light levels, serving dual purposes as lighting elements. Commercialization efforts are focused on achieving large-scale production, long-term durability, and a memory effect that maintains coloration without applied voltage. Enhancing durability has received particular attention, leading to the development of electrochromic mirrors that employ gel electrolytes, which are expected to reduce electrolyte leakage and improve mechanical stability compared to traditional liquid electrolyte devices. The gel electrolytes offer the additional advantage of various colors, by controlling the metal particle size and enabling smoother, denser formations. In this study, we investigated improving the durability of RME devices by adding polyvinyl butyral (PVB) to the liquid electrolyte and optimizing the concentration of PVB. Incorporating 10 % PVB resulted in excellent interfacial properties and superior electrochromic stability, with 92.6 % retention after 1,000 cycles.
벨로우즈 신축이음관은 구조적 특성으로 인해 큰 변위 용량을 갖으며 과도한 상대변위에 의한 매립 배관 시스템의 손상을 저감시키기 위해 연결부로써 사용된다. 벨로우즈 신축이음관의 내진성능 평가를 위한 연구에서 한계상태는 변형률을 적용하였지만 변형률 기반 한계상태는 벨로우즈 신축이음관의 큰 변위용량을 고려할 수 없다. 또한 벨로우즈 신축이음관의 성능평가와 한계상태 분석을 위한 해석적 및 실험적 연구는 수행된 사례가 극히 적다. 따라서 본 연구는 단조 및 반복하중을 받는 벨로우즈 신축이 음관의 해석적 연구를 통해 벨로우즈 신축이음관의 한계상태를 분석하였다. 결과적으로 단조하중 보다 반복하중을 받는 벨로우즈 신축이음관은 더 낮은 변위에서 누출이 발생하였다. 반복하중으로 인한 피 로 및 라체팅 현상으로 인해 단조하중 보다 낮은 변위의 성능을 갖는 것으로 보여진다. 따라서 반복하 중에서 관측된 변위응답을 기반으로 벨로우즈 신축이음관의 내진성능 평가를 수행하는 것이 보수적일 것으로 판단된다.
최근, 큰 처짐과 다수의 균열을 동반하는 유사연성 거동과 부식에 대한 높은 내구성의 특징을 가진 FRCM(Fabric-Reinforced Cemenetitious Matrix) 복합체에 대한 관심이 증가하고 있다. 철근콘크리트 부재에 대해 다양한 장점을 지닌 FRMC 복합체를 적용할 경우 전단내력의 증대를 예상할 수 있으며, 이를 통해 내진성능이 요 구되는 철근콘크리트 구조물에 효과를 기대할 수 있다. 본 연구에서는 FRCM 복합체가 보강된 철근콘크리트 기둥에 대해 정적 반복가력 실험을 수행하고, 그 거동을 평가 하였다. 철근콘크리트 기둥은 직사각형 형상으로 단면의 크기가 300 × 300 mm이고, 순 높이는 800 mm로 제작되었다. 정적 반복가력 실험은 설정한 가력패턴에 따라 변위제어를 통해 횡 하중을 가력하 였고, 초기 축력은 기둥 용량의 10 %로 적용하였다. 정적 반복가력 실험 결과, 무보강 실험체 대비 약 27.33 %의 증진된 강도를 나타내었으며, 최대 강도 발현 시 층간변위비가 무보강 실험체 대비 약 187.6% 높게 나타냄에 따라 FRCM 복합체가 적용된 철근콘크리트 기둥의 높은 연성 거동을 확인 할 수 있다. 다만, FRCM 복합체를 실제 구조물에 적용하기 위해서는 추가적인 설계인자 개발을 통해 안 정성 및 신뢰성을 확보하는 것이 필수적이라고 판단된다.
원자력 발전소에서 배관 시스템은 냉각수 및 오염수를 운반하고 생성된 증기를 터빈으로 이동시켜 에너지를 생산하는 중요한 설비이다. 국내에 건설된 원자력 발전소의 가동연수가 증가함에 따라 배관 시스템의 물리적, 기계적 성질의 열화현상은 발생할 수 있으며 이를 경년열화로 정의한다. 배관 시스 템의 경년열화는 재료의 피로, 부식(국부감육), 마모 등과 같은 메커니즘을 통해 발생할 수 있으며 재 료의 강도 및 시스템의 성능 저하와 균열을 야기할 수 있다. 지속적이고 안정적인 에너지 생산을 위해 경제성과 정확도를 고려한 원전 배관 시스템의 손상 감시 기술은 필요하다. 따라서 본 연구는 원전 배 관 시스템의 손상 감시 기술을 개발하기 위한 기초적인 연구로써 배관 시스템의 취약요소로 판단되는 elbow의 국부적인 감육에 따른 거동의 변화를 분석하고자 한다.
In the case of the Pohang earthquake, which had a magnitude of 5.4 in 2017, geotechnical damages such as liquefaction and ground settlement occurred. The need for countermeasures has emerged, and experimental research in the Pohang area has continued. This study collected undisturbed samples from damaged fine-grained soil areas where ground settlement occurred in Pohang. Cyclic tri-axial tests for identifying the dynamic characteristics of soils were performed on the undisturbed samples, and the results were analyzed to determine the cause of ground settlement. As a result of the study, it was determined that in the case of fine-grained soils, ground settlement occurred because the seismic load as an external force was relatively more significant than the shear resistance of the very soft fine-grained soils, rather than due to an increase in excess pore water pressure.
Damage to gas and fire protection piping systems can lead to secondary disasters after an earthquake, so their seismic design is crucial. Accordingly, various types of seismic restraint installations are being devised, and a new suspended piping trapeze restraint installation has also recently been developed in Korea. In this study, a cyclic loading test was performed on the developed trapeze support system, and its performance was evaluated according to ASHRAE 171, the standard for seismic and wind restraint design established by the American Society of Refrigeration and Air Conditioning Engineers (ASHRAE). The three support system specimens did not break or fracture, causing only insignificant deformations until the end of the experiment. Based on the experimentally rated strength and displacement performance, this trapeze support system is expected to control the seismic movement of piping during an earthquake.
횡하중에 작용하는 철근 콘크리트 기둥은 연성능력 확보를 위해 띠철근의 양 단부를 135° 구부려 시공하는 상세가 요구된다. 그러 나 이러한 띠철근 상세는 시공이 매우 까다로와 실제 현장에서는 제대로 시공이 되지 않기도 한다. 이를 대체하기 위해 본 논문에서는 강재 클립형 연결장치가 적용된 철근 콘크리트 기둥에 대해 횡방향 반복가력 실험을 수행하고 그 구조적 성능을 평가하였다. 총 4개 의 실험체가 제작되었으며 주요 실험변수는 강재 클립형 연결장치 및 고강도 콘크리트 사용 여부이다. 또한 대상 구조물에 대해 3차 원 유한요소해석 모델을 개발하고 이에 대한 비선형 해석을 수행하였으며, 해석 및 실험결과를 비교하고 분석하였다. 그 결과 강재 클 립형 연결장치가 설치된 콘크리트 기둥이 반복 횡하중에 대해 기존의 표준갈고리 상세를 지닌 콘크리트 기둥과 동등한 혹은 그 이상 의 성능을 지니고 있으며, 개발된 유한요소해석 모델이 실험결과를 정확히 잘 예측하는 것으로 나타났다.
이 논문에서는 내구성이 우수한 것으로 알려져 있는 펄트루젼 FRP의 습도 노출 및 동결 융해 영향을 검토하고, 이에 따른 국부좌굴강도 영향을 검토하기 위한 해석적 연구를 수행하였다. FRP는 일반적으로 내구성이 우수하다고 알려져 있기 때문 에, 해양 구조물 등 습윤환경에서 적용하기 위한 다양한 연구가 진행되고 있으며, 특히 구조용 부재로 제작되는 펄트루젼 FRP 부재는 하절기와 동절기의 온도변화에 노출되기 때문에 이에 대한 검토가 필요하다. 펄트루젼 FRP의 습도 노출 및 동결 융해 영향은 기존 연구의 실험 결과를 참고하였으며, 국부좌굴강도는 정밀해법을 통해 영향을 검토하였다. 검토 결과 펄트루젼 FRP 는 습도노출 및 동결융해의 영향으로 인해 최대 약 20%의 인장강도 및 탄성계수 변화를 나타내었으나, 국부좌굴강도는 약 3% 로 그 영향이 상대적으로 작은 것으로 나타났다. 따라서, 온도이력 및 습윤환경에서도 펄트루젼 FRP는 국부좌굴강도의 큰 변화 를 나타내지 않고 높은 내구성을 나타낼 수 있을 것으로 판단된다.
Recently, a novel cast-in specialty insert was developed in Korea as an anchor for lightweight pipe supports, including fire-protection pipes. As these pipe supports and anchors play a critical role in transferring loads of fire-protection pipes to structural members, it is crucial to evaluate their seismic performance before applying the newly developed insert. In this study, the seismic shear performance of the insert anchors was evaluated through cyclic loading tests based on the loading protocols of ACI 355.2 and FEMA 461. Initially, five monotonic loading tests were conducted on the insert anchors in cracked concrete, followed by cyclic loading tests based on the monotonic test results. The findings revealed that the insert anchors exhibited negligible decrease in shear strength even after cyclic loading. Furthermore, a comparison of the maximum load and displacement of the insert anchors obtained under the loading protocols of ACI 355.2 and FEMA 461 was performed to investigate the applicability of the FEMA 461 loading protocol for anchor performance evaluation.
This study investigated the rocking behavior of unreinforced masonry walls and wall piers under cyclic loading. Based on the benchmark tests, the characteristics of load-deformation relations in masonry walls with rocking failure were captured, focusing on observed deformation modes. The rocking strengths of masonry walls (i.e., peak and residual strengths) were evaluated, and the effects of opening configurations on the masonry wall strength were examined. The deformation capacity of the rocking behavior and the hysteresis shape of the load-deformation relations were also identified. Based on the results, modeling approaches for the rocking behavior of masonry walls were discussed.
The columns of older reinforced concrete (RC) buildings generally have limited reinforcement details. Thus, they could be vulnerable to earthquake ground motions, leading to partial or complete building collapse. In this study, high-performance fiber-reinforced cementitious composite (HPFRCC) was applied to RC columns to improve their seismic behavior. Experimental tests were conducted with two full-sized specimens with limited reinforcement details, including short lap splices, while unidirectional loadings were applied to the specimens. The seismic behavior of RC columns was substantially improved by using HPFRCC.
The central theme of this work is the synthesis of single-walled carbon nanotubes (SWCNTs) through the chemical vapor deposition method (CVD). Single-walled carbon nanotubes are synthesized using catalyst-chemical vapor deposition of acetylene at 750 °C temperature. X-ray diffraction study gives a characteristic peak (002) at 26.55° corresponding to the existence of carbon nanotube confirms that the particles are crystalline in nature and hexagonal phase. An SEM and HRTEM outcome gives surface morphology of SWCNTs. The elemental composition was confirmed by EDAX. The ideal concentration of single-walled carbon nanotubes was used to design a novel electrochemical sensor for determining paracetamol (PA) using cyclic voltammetry. Electrochemical determination of paracetamol is described using a single-walled carbon nanotube modified carbon paste electrode (SWCNT/MCPE). The SWCNT/MCPE was used in this study to detect paracetamol electrochemically at pH 7.2 in a 0.2 M PBS with a scan rate of 50 mV s− 1. A single-walled nanotube modified carbon paste electrode was used to develop a sensitive and selective electrochemical technique for the detection of PA. The SWCNT/MCPE showed excellent electrocatalytic activity towards the oxidation of paracetamol in phosphate buffer solution. Therefore, with increased oxidation currents, the voltammetric responses of paracetamol at the bare carbon paste electrode are organized within cyclic voltammetric peaks.
Activated corrosion products deposited on the reactor coolant system in a nuclear power plant should be removed to reduce the radiation exposure to workers. Chemical decontamination processes using organic acids have been widely applied to remove the activated corrosion products. However, they are highly corrosive to the base metal and generate a considerable amount of ion exchange resin waste, which is hard to be treated. In order to resolve this problem, KAERI has been developed a chemical decontamination process using chelate-free inorganic acid, HyBRID (Hydrazine Based Reductive metal Ion Decontamination) process. Especially, the Cyclic SP (Sulfuric acid/Permanganate)- HyBRID process was suggested as the decontamination process for applying to the remove the double oxide layer generated on the reactor coolant system in the pressurized water reactor (PWR). During the Cyclic SP-HyBRID process, the process is continuously applied without discharging or recharging of the decontamination process solution from the primary circuit. Thus, it is necessary to include the removal processes of the decontamination reagents middle of the Cyclic SP-HyBRID process, e.g., ‘Mn removal step’ for removing the permanganate ions and ‘hydrazine decomposition step’ for decomposition of the remaining hydrazine. During these removal processes, the metal ions can also be removed from the process solution. In this study, the behaviors of metals were investigated during the Cyclic SP-HyBRID process. The concentration changes of metal ions in the process solution were analyzed using atomic absorption (AA) spectroscopy. The metal precipitates generated during the process were characterized using X-ray diffraction (XRD) and Fourier Transform Infrared (FT-IR) spectroscopy. From the results of the analysis, it was observed that the metal ions dissolved in the process solution were converted into metal hydroxides and precipitated at the Mn removal process. It was confirmed by equilibrium calculation result that the OH− ions generated at the Mn removal can react with the metal ions and form the metal hydroxides. It is considered that this removal behaviors of the metals can contribute the decontamination performance.
배관 시스템은 다양한 산업영역에서 액체 및 기체로 이루어진 에너지를 수송을 담당하는 중요한 비구조요소로 지진과 같은 외부하중에 의해 손상될 경우 누수로 인한 홍수 및 가연성 가스 누출로 인한 화재 등의 2차피해가 발생할 수 있다. 배관 시스템은 구조물 내부에 설치되는 경우도 있으며 지반에 매립되어 설치되는 경우도 있다. 지반에 매립될 경우 지진으로 인한 과도한 상대변위에 의해 연결부의 손상을 초래할 수 있어 종종 벨로우즈 신축이음관을 적용하여 이러한 피해를 저감시킬 수 있다. 따라서 본 연구에서는 벨로우즈 신축이음관의 반복가력 실험을 기반으로 유한요소 모델을 구축 하여 내진성능을 검토하였다. 반복가력실험은 ±28mm 변위에서 최대 ±123.4mm까지 증가시켜 변위제어를 통해 수행되었으며 추가적으로 유한요소 모델의 신뢰성을 높이기 위해 벨로우즈 배관에 사용된 재료인 STS304의 재료 인장실험을 수행하여 탄성계수 및 항복응력을 결정하였다. 에너지 소산량과 등가 점성 감쇠를 비교하여 개발된 모델의 타당성을 검토하였으며 적용되는 변위가 커짐에 따라 최대 10% 미만의 오차가 발생하여 실험 및 해석결과가 잘 일치하는 것으로 나타났다.
As the damage caused by earthquakes gradually increases, seismic retrofitting for existing public facilities has been implemented in Korea. Several types of structural analysis methods can be used to evaluate the seismic performance of structures. Among them, for nonlinear dynamic analysis, the hysteresis model must be carefully applied because it can significantly affect the behavior. In order to find a hysteresis model that predicts rational behavior, this study compared the experimental results and analysis results of the existing non-seismic reinforced concrete frames. For energy dissipation, the results were close to the experimental values in the order of Pivot, Concrete, Degrading, and Takeda models. The Concrete model underestimated the energy dissipation due to excessive pinching. In contrast, the other ones except the Pivot model showed the opposite results with relatively little pinching. In the load-displacement curves, the experimental and analysis results tended to be more similar when the column axial force was applied to columns.
최근 우리나라는 대규모 지진이 빈번히 발생하고 있으며, 유감지진의 발생 규모 및 빈도가 급격히 증가하고 있어 지 진피해 저감 기술에 대한 관심이 증대되고 있다. 기존 지진피해 저감 기술은 구조물의 단면적을 크게하여 강성을 증가시키는 방법으로 과도한 설계 및 시공이 발생하여 상당한 비용이 소요되고 경제적인 측면에서 비효율적이다. 구조물에 대해 지진하중 으로부터 효율적으로 대응하기 위한 내진설계 방법에는 제진기술이 있다. 제진기술에 활용되는 제진장치는 지진 발생 후 재료의 항복으로 인해 장치의 손상 및 파괴가 발생하여 교체가 불가피하고 시간 및 비용이 소요된다. 따라서 이 연구에서는 기존 제진기술의 단점을 보완하기 위하여 에너지 소산 능력 및 복원력이 우수한 초탄성 형상기억합금 및 폴리우레탄 적용 자동복원 감쇠장치의 구조실험을 수행 및 분석하여 지진 발생 후 지속적으로 활용 가능한 댐퍼 장치에 대한 연구를 수행하였다.
The objective of this research work was to know ovarian dynamics and pregnancy rate of cyclic Murrah buffalo cows with induced estrus by administration of prostaglandin F2α (PGF2α) and timed artificial insemination (TAI) with frozen thawed semen. A total of 31 female buffaloes were selected for the study. The buffalos having matured CL observed by ultrasonography were given one intra muscular injection of cloprostenol 500 μg and TAI was performed using frozen thawed semen of Indian Murrah buffalo bull. Results showed that 90.32% (significantly, at p < 0.05) cows explore the sign of heat after injection of PG and 67.85% (significantly, at p < 0.05) cows were become pregnant out of 28 inseminated (TAI) cows. In the 28 inseminated (TAI) cows, average number of smaller and larger size of follicles were non-significantly (p > 0.05) higher at day 3 post PG injection, but the medium size of follicles was non-significantly (p > 0.05) higher at PG injection. At day 3 post PG injection the diameter of follicles was significantly (p < 0.05) higher, but the diameter of CL was significantly (p < 0.01) lower compared at PG injection. At PG injection the diameter of largest follicle was non-significantly differences (p > 0.05) in between pregnant and non-pregnant cows. But at day 3 post PG injection it was significantly (p < 0.01) higher in pregnant cows compared to non-pregnant cows. The number of small, medium, and large follicles at PG injection and at day 3 post PG injection were non-significantly (p > 0.05) difference in between pregnant and non-pregnant buffalo cows. Finally, it is concluded that the CL was effectively regresses and induced the sign of heat in buffalo cows and after AI the cows were become pregnant with significant rate. The study will help to the veterinarian and researcher to know the efficacy of PG injection and AI for reproductive efficiency in buffalo cows.
Molten salt solutions consisting of eutectic LiCl-KCl and concentrations of samarium chloride (0.5 to 3.0 wt%) at 500℃ were analyzed using both cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The CV technique gave the average diffusion coefficient for Sm3+ over the concentration range. Equipped with Sm3+ diffusion coefficient, the Randles-Sevcik equation predicted Sm3+ concentration values that agree with the given experimental values. From CV measurements; the anodic, cathodic, and half-peak potentials were identified and subsequently used as a parameter to acquire EIS spectra. A six-element Voigt model was used to model the EIS data in terms of resistance-time constant pairs. The lowest resistances were observed at the half-peak potential with the associated resistance-time constant pairs characterizing the reversible reaction between Sm3+ and Sm2+. By extrapolation, the Voigt model estimated the polarization resistance and established a polarization resistance-concentration relationship.